https://www.phoenixcontact.com/us/products/2688019 Bus coupler - AXL BK PN - 2688019 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Axioline bus coupler for PROFINET (including bus base module and connector) Product description The bus coupler links a PROFINET network with the Axioline system. Up to 63 Axioline devices can be connected at any point to an existing PROFINET system using the bus coupler. For startup tests you can put the Axioline station into operation independent of the higher-level network either using the service interface or an Ethernet port at the bus coupler. Product Features Up to 63 additional Axioline devices can be connected Firmware can be updated Minimum cycle time of PROFINET for RT is 250 s Diagnostic and status indicators Runtime in bus coupler is negligible (almost 0 s) PROFINET RT Typical cycle time of the Axioline system bus is around 10 s 2 RJ45 connections (with integrated switch) Module replacement without software Key commercial data Packing unit 1 pc Weight per Piece (excluding packing) 200.0 GRM Custom tariff number 85389091 Country of origin Germany Technical data Dimensions Width 40 mm Height 123.6 mm 09/03/2014 Page 1 / 5 https://www.phoenixcontact.com/us/products/2688019 Bus coupler - AXL BK PN - 2688019 Technical data Dimensions Depth 75 mm Note on dimensions The depth is valid when a TH 35-7.5 DIN rail is used (according to EN 60715). Ambient conditions Ambient temperature (operation) -25 C ... 60 C Ambient temperature (storage/transport) -40 C ... 85 C Permissible humidity (operation) 5 % ... 95 % (according to DIN EN 61131-2) Permissible humidity (storage/transport) 5 % ... 95 % (according to DIN EN 61131-2) Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level) Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level) Degree of protection IP20 Connection data Designation Axioline F connector Connection method Push-in technology Conductor cross section solid min. 0.2 mm Conductor cross section solid max. 1.5 mm Conductor cross section stranded min. 0.2 mm Conductor cross section stranded max. 1.5 mm Conductor cross section AWG/kcmil min. 24 Conductor cross section AWG/kcmil max 16 General Weight 173 g Note on weight specifications with connector Mounting type DIN rail Protection class III, IEC 61140, EN 61140, VDE 0140-1 Conformance with EMC directives Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 6100042/IEC 6100042 Criterion B; 6 kV contact discharge, 8 kV air discharge Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 6100043/IEC 6100043 Criterion A; Field intensity: 10 V/m Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 6100044/IEC 6100044 Criterion B, 2 kV Noise immunity test in accordance with EN 61000-6-2 Transient surge voltage (surge) EN 6100045/IEC 6100045 Criterion B; DC supply lines: 0.5 kV/0.5 kV (symmetrical/asymmetrical); fieldbus cable shield: 1 kV Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 6100046/IEC 6100046 Criterion A; Test voltage 10 V Noise emission test according to EN 61000-6-3 Radio interference properties EN 55022 Class B 09/03/2014 Page 2 / 5 https://www.phoenixcontact.com/us/products/2688019 Bus coupler - AXL BK PN - 2688019 Technical data General Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g Shock in acc. with EN 60068-2-27/IEC 60068-2-27 25g, 11 ms period, halfsine shock pulse Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g Interfaces Fieldbus system PROFINET Designation PROFINET Connection method RJ45 socket, auto negotiation and autocrossing Transmission speed 100 MBit/s (Full duplex) Transmission physics Ethernet in RJ45 twisted pair Fieldbus system Lokalbus Designation Axioline F local bus Connection method Connection for bus base module Transmission speed 100 MBit/s Designation Service Connection method IFS-USB-PROG-ADAPTER System limits of the bus coupler Amount of process data 1485 Byte (for each data direction) Number of supported devices max. 63 (per station) Number of local bus devices that can be connected max. 63 Power supply for module electronics Current consumption max. 600 mA (from UBK) Power loss typ. 2 W ((without I/Os)) Axioline potentials Supply of communications power UL 24 V DC Current consumption from UL typ. 86 mA (without I/Os and UL = 24 V) max. 600 mA (with 2 A at UBus for the I/Os and UL = 24 V) max. 750 mA (with 2 A load at UBus for the I/Os and UL = 19 V) Communications power UBus 5 V DC (via bus base module) Current supply at UBus 2A Digital inputs Connection method Push-in connection 09/03/2014 Page 3 / 5 https://www.phoenixcontact.com/us/products/2688019 Bus coupler - AXL BK PN - 2688019 Classifications eCl@ss eCl@ss 4.0 27240490 eCl@ss 4.1 27240490 eCl@ss 5.0 27242208 eCl@ss 5.1 27242608 eCl@ss 6.0 27242608 eCl@ss 7.0 27242608 eCl@ss 8.0 27242608 ETIM ETIM 3.0 EC001604 ETIM 4.0 EC001604 ETIM 5.0 EC001604 UNSPSC UNSPSC 6.01 43172015 UNSPSC 7.0901 43201404 UNSPSC 11 39121311 UNSPSC 12.01 39121311 UNSPSC 13.2 39121311 Approvals Approvals Approvals UL Listed / cUL Listed / PROFIBUS / cULus Listed Ex Approvals Approvals submitted Approval details UL Listed 09/03/2014 Page 4 / 5 https://www.phoenixcontact.com/us/products/2688019 Bus coupler - AXL BK PN - 2688019 Approvals cUL Listed PROFIBUS cULus Listed Drawings Connection diagram Dimensioned drawing 40 75 SF BF M RDY D PROFINET LNK1 ACT1 LNK2 ACT2 UL a1 b2 122,4 b1 123,6 24 V DC + (UL) a2 Phoenix Contact 2014 (c) - all rights reserved http://www.phoenixcontact.com 09/03/2014 Page 5 / 5