GE
Data Sheet
January 20, 2016 ©2016 General Electric Company. All rights reserved.
Austin MegaLynxTM: Non-Isolated DC-DC Power Modules
4.5Vdc 5.5Vdc input; 0.8Vdc to 3.63Vdc output; 30A Output Current
6Vdc 14Vdc input; 0.8Vdc to 3.63Vdc output; 20/30A Output Current
Features
Compliant to RoHS EU Directive 2011/65/EU (-Z
versions)
Compliant to RoHS EU Directive 2011/65/EU under
exemption 7b (Lead solder exemption). Exemption 7b
will expire after June 1, 2016 at which time this
product will no longer be RoHS compliant (non-Z
versions)
Delivers up to 30A of output current
High efficiency: 92% @ 3.3V full load (12Vin)
Available in two input voltage ranges
ATH: 4.5 to 5.5Vdc
ATS: 6 to 14Vdc
Output voltage programmable from
ATH: 0.8 to 3.63Vdc
ATS030: 0.8 to 2.75Vdc
ATS020: 0.8 to 3.63Vdc
Small size and low profile:
33.0 mm x 10.0 mm x 13.5 mm
(1.30 in. x 0.39 in. x 0.53 in.)
Monotonic start-up into pre-biased output
Output voltage sequencing (EZ-SEQUENCETM)
Remote On/Off
Remote Sense
Over current and Over temperature protection
-P option: Paralleling with active current share
-H option: Additional GND pins for improved thermal
derating
Wide operating temperature range (-40°C to 85°C)
UL* 60950 Recognized, CSA C22.2 No. 60950-00
Certified, and VDE 0805 (EN60950-1 3rd edition)
Licensed
ISO** 9001 and ISO 14001 certified manufacturing
facilities
Applications
Distributed power architectures
Intermediate bus voltage applications
Telecommunications equipment
Servers and storage applications
Networking equipment
Description
The Austin MegaLynx series SMT power modules are non-isolated DC-DC converters in an industry standard package that can
deliver up to 30A of output current with a full load efficiency of 92% at 2.5Vdc output voltage (VIN = 12Vdc). The ATH series of
modules operate off an input voltage from 4.5 to 5.5Vdc and provide an output voltage that is programmable from 0.8 to
3.63Vdc, while the ATS series of modules have an input voltage range from 6 to 14V and provide a programmable output voltage
ranging from 0.8 to 3.63Vdc. Both series have a sequencing feature that enables designers to implement various types of output
voltage sequencing when powering multiple modules on the board. Additional features include remote On/Off, adjustable output
voltage, remote sense, over current, over temperature protection and active current sharing between modules.
* UL is a registered trademark of Underwriters Laboratories, Inc.
CSA is a registered trademark of Canadian Standards Association.
VDE is a trademark of Verband Deutscher Elektrotechniker e.V.
** ISO is a registered trademark of the International Organization of Standards
RoHS Compliant
Preliminary Data Sheet
Austin MegaLynx
TM
: Non-Isolated DC-DC Power Modules
4.5Vdc 5.5Vdc input; 0.8Vdc to 3.63Vdc output; 30A Output Current
6Vdc 14Vdc input; 0.8Vdc to 3.63Vdc output; 20/30A Output Current
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings
only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations
sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability.
Parameter Device Symbol Min Max Unit
Input Voltage
Continuous ATH VIN -0.3 6 Vdc
ATS VIN -0.3 15 Vdc
Sequencing pin voltage ATH VsEQ -0.3 6 Vdc
ATS VsEQ -0.3 15 Vdc
Operating Ambient Temperature All TA -40 85 °C
(see Thermal Considerations section)
Storage Temperature All Tstg -55 125 °C
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.
Parameter Device Symbol Min Typ Max Unit
Operating Input Voltage ATH VIN 4.5 5.0 5.5 Vdc
ATS VIN 6.0 12 14 Vdc
Maximum Input Current ATH IIN,max 27 Adc
(VIN= VIN,min , VO= VO,set, IO=IO, max) ATS020 IIN,max 13.3 Adc
ATS030 IIN,max 15.8 Adc
Inrush Transient All I2 t 1 A2 s
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 1μH source impedance; VIN=6.0V
to 14.0V, IO= IOmax ; See Figure 1)
All 100 mAp-p
Input Ripple Rejection (120Hz) All 50 dB
Preliminary Data Sheet
Austin MegaLynx
TM
: Non-Isolated DC-DC Power Modules
4.5Vdc 5.5Vdc input; 0.8Vdc to 3.63Vdc output; 30A Output Current
6Vdc 14Vdc input; 0.8Vdc to 3.63Vdc output; 20/30A Output Current
January 20, 2016
©
2016 General Electric Company. All rights reserved. Page
3
Electrical Specifications (continued)
Parameter Device
Symbo
l
Min Typ Max Unit
Output Voltage Set-point All VO, set -1.5 +1.5 % VO, set
(VIN=VIN,nom, IO=IO, nom, Tref=25°C)
Output Voltage
(Over all operating input voltage, resistive load, and
temperature conditions until end of life) All VO, set –5.0 +3.0 % VO, set
Adjustment Range
Selected by an external resistor ATS030 0.8 2.75 Vdc
ATS020 0.8 3.63 Vdc
ATH030* 0.8 3.63 Vdc
* VO 3.3V only possible for VIN 4.75V
Output Regulation
Line (VIN=VIN, min to VIN, max) All 20 mV
Load (IO=IO, min to IO, max) All 40 mV
(-P version) 70 mV
Temperature (Tref=TA, min to TA, max) All 0.5 1 % VO, set
Output Ripple and Noise on nominal output
(VIN=VIN, nom and IO=IO, min to IO, max
COUT = 0.1μF // 10 μF ceramic capacitors)
Peak-to-Peak (5Hz to 20MHz bandwidth) Vo ≤ 2.5V 50 mVpk-pk
Peak-to-Peak (5Hz to 20MHz bandwidth) 2.5V < Vo 3.63V 75 mVpk-pk
Peak-to-Peak (5Hz to 20MHz bandwidth) Vo > 3.63V 100 mVpk-pk
External Capacitance 1
ESR 1 mΩ All CO, max 0 2,000 μF
ESR 10 mΩ All CO, max 0 10,000 μF
Output Current
(VIN = 4.5 to 5.5Vdc) ATH Series Io 0 30 Adc
(VIN = 6 to 14Vdc) ATS030 Series Io 0 30 Adc
(VIN = 6 to 14Vdc) ATS020 Series Io 0 20 Adc
Output Current Limit Inception (Hiccup Mode) All IO, lim 140 % Iomax
Output Short-Circuit Current All IO, s/c 3.5 Adc
(VO≤250mV) ( Hiccup Mode )
Efficiency VO,set = 0.8dc η
82.2
%
ATH Series: VIN=5Vdc, TA=25°C VO,set = 1.2Vdc η 85.8 %
IO=IO, max , VO= VO,set VO,set = 1.5Vdc η 89.5 %
VO,set = 1.8Vdc η
89.2
%
VO,set = 2.5Vdc η
92.0
%
VO,set = 3.3Vdc η 92.2 %
1 Note that maximum external capacitance may be lower when sequencing is employed. Please check with your GE Technical
representative.
Preliminary Data Sheet
Austin MegaLynx
TM
: Non-Isolated DC-DC Power Modules
4.5Vdc 5.5Vdc input; 0.8Vdc to 3.63Vdc output; 30A Output Current
6Vdc 14Vdc input; 0.8Vdc to 3.63Vdc output; 20/30A Output Current
January 20, 2016
©
2016 General Electric Company. All rights reserved. Page
4
Electrical Specifications (continued)
Parameter Device Symbol Min Typ Max Unit
ATS Series: VIN=12Vdc, TA=25°C VO,set = 0.8dc η 77.5 %
IO=IO, max , VO= VO,set VO,set = 1.2Vdc η 83.5 %
VO,set = 1.8Vdc η 86.5 %
VO,set = 2.5Vdc η 91.3 %
VO,set = 3.3Vdc η 92.1 %
Switching Frequency, Fixed All fsw 300 kHz
Dynamic Load Response
(dIO/dt=5A/µs; VIN=12V, Vo=3.3V ; TA=25°C)
Load Change from Io= 50% to 100% of IO,max; No
external output capacitors
Peak Deviation All Vpk 350 mV
Settling Time (VO<10% peak deviation) All ts 25 µs
(dIO/dt=5A/µs; VIN=VIN, nom; TA=25°C)
Load Change from IO= 100% to 50%of IO, max: No
external output capacitors
Peak Deviation All Vpk 350 mV
Settling Time (VO<10% peak deviation) All ts 25 µs
(dIO/dt=5A/µs; VIN=VIN, nom; TA=25°C)
Load Change from Io= 50% to 100% of Io,max; 2x150 μF
polymer capacitor
Peak Deviation All Vpk 250 mV
Settling Time (VO<10% peak deviation) All ts 40 µs
(dIO/dt=5A/µs; VIN=VIN, nom; TA=25°C)
Load Change from Io= 100% to 50%of IO,max: 2x150 μF
polymer capacitor
Peak Deviation All Vpk 250 mV
Settling Time (VO<10% peak deviation) All ts 40 µs
General Specifications
Parameter Min Typ Max Unit
Calculated MTBF (VIN=12V, VO=3.3Vdc, IO= 0.8IO, max, TA=40°C) Per
Telecordia Method 3,016,040 Hours
Weight 6.2 (0.22) g (oz.)
Preliminary Data Sheet
Austin MegaLynx
TM
: Non-Isolated DC-DC Power Modules
4.5Vdc 5.5Vdc input; 0.8Vdc to 3.63Vdc output; 30A Output Current
6Vdc 14Vdc input; 0.8Vdc to 3.63Vdc output; 20/30A Output Current
January 20, 2016
©
2016 General Electric Company. All rights reserved. Page
5
Feature Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See
Feature Descriptions for additional information.
Parameter Device Symbol Min Typ Max Unit
On/Off Signal Interface
(VIN=VIN, min to VIN, max ; open collector or equivalent,
Signal referenced to GND)
Logic High (Module OFF)
Input High Current All IIH 0.5 3.3 mA
Input High Voltage All VIH 3.0 VIN, max V
Logic Low (Module ON)
Input Low Current All IIL 200 µA
Input Low Voltage All VIL -0.3 1.2 V
Turn-On Delay and Rise Times
(VIN=VIN, nom, IO=IO, max , VO to within ±1% of steady state)
Case 1: On/Off input is enabled and then
input power is applied (delay from instant at
which VIN = VIN, min until Vo = 10% of Vo, set)
All
Tdelay
2.5
5
msec
Case 2: Input power is applied for at least one second and then the
On/Off input is enabled (delay from instant at which Von/Off is enabled
until Vo = 10% of Vo, set)
All
Tdelay
2.5
5
msec
Output voltage Rise time (time for Vo to rise from
10% of Vo, set to 90% of Vo, set)
All
Trise
2
10
msec
Output voltage overshoot 3.0 % VO, set
IO = IO, max; VIN, min – VIN, max, TA = 25 oC
Remote Sense Range All 0.5 V
Over temperature Protection All Tref 125 °C
(See Thermal Consideration section)
Sequencing Slew rate capability All dVSEQ/dt 2 V/msec
(VIN, min to VIN, max; IO, min to IO, max VSEQ < Vo)
Sequencing Delay time (Delay from VIN, min
to application of voltage on SEQ pin) All TsEQ-delay 10 msec
Tracking Accuracy Power-up (2V/ms) All VSEQ –Vo 100 200 mV
Power-down (1V/ms) VSEQ –Vo 200 400 mV
(VIN, min to VIN, max; IO, min - IO, max VSEQ < Vo)
Input Undervoltage Lockout
Turn-on Threshold ATH 4.3 Vdc
Turn-off Threshold ATH 3.9 Vdc
Turn-on Threshold ATS 5.5 Vdc
Turn-off Threshold ATS 5.0 Vdc
Forced Load Share Accuracy -P 10 % Io
Number of units in Parallel -P 5
Preliminary Data Sheet
Austin MegaLynx
TM
: Non-Isolated DC-DC Power Modules
4.5Vdc 5.5Vdc input; 0.8Vdc to 3.63Vdc output; 30A Output Current
6Vdc 14Vdc input; 0.8Vdc to 3.63Vdc output; 20/30A Output Current
January 20, 2016
©
2016 General Electric Company. All rights reserved. Page
6
Characteristic Curves
The following figures provide typical characteristics for the ATS030A0X3-SR & -SRH (0.8V, 30A) at 25oC.
EFFICIENCY, η (%)
OUTPUT CURRENT, Io (A)
OUTPUT CURRENT, I
O
(A)
AMBIENT TEMPERATURE, T
A
O
C
Figure 1. Converter Efficiency versus Output Current. Figure 4. Derating Output Current versus Ambient
Temperature and Airflow (ATS030A0X3-SRH).
OUTPUT VOLTAGE
VO (V) (20mV/div)
OUTPUT CURRENT, Io (A)
TIME, t (1µs/div) AMBIENT TEMPERATURE, TA OC
Figure 2. Typical output ripple and noise (V
IN
= V
IN,NOM
, I
o
=
Io,max).
Figure 5. Derating Output Current versus Ambient
Temperature and Airflow (ATS030A0X3-SR).
OUTPUT CURRENT, OUTPUT VOLTAGE
IO (A) (5Adiv) VO (V) (100mV/div)
INPUT VOLTAGE OUTPUT VOLTAGE
VIN (V) (5V/div) VO (V) (0.5V/div)
TIME, t (20µs /div) TIME, t (5ms/div)
Figure 3. Transient Response to Dynamic Load Change from
0% to 50% to 0% of full load with VIN =12V.
Figure 6. Typical Start-up Using Input Voltage (VIN = VIN,NOM, Io
= Io,max).
70
75
80
85
90
0 5 10 15 20 25 30
Vin = 12 V
Vin = 6 V
Vin = 14 V
0
5
10
15
20
25
30
35
35 45 55 65 75 85
0.5m/s
(100LFM)
1m/s
(200LFM)
1.5m/s
(300LFM)
2.0m/s
(400LFM)
2.5m/s
(500LFM)
0
5
10
15
20
25
30
35
35 45 55 65 75 85
NC
0.5m/s
(100LFM)
1m/s
(200LFM)
1.5m/s
(300LFM)
2m/s
(400LFM)
2.5m/s
(500LFM)
Preliminary Data Sheet
Austin MegaLynx
TM
: Non-Isolated DC-DC Power Modules
4.5Vdc 5.5Vdc input; 0.8Vdc to 3.63Vdc output; 30A Output Current
6Vdc 14Vdc input; 0.8Vdc to 3.63Vdc output; 20/30A Output Current
January 20, 2016
©
2016 General Electric Company. All rights reserved. Page
7
Characteristic Curves
The following figures provide typical characteristics for the ATS030A0X3-SR and -SRH (1.25V, 30A) at 25oC.
EFFICIENCY, η (%)
OUTPUT CURRENT, I
O
(A)
Figure 7. Converter Efficiency versus Output Current.
OUTPUT CURRENT, Io (A)
AMBIENT TEMPERATURE, TA OC
Figure 8. Derating Output Current versus Ambient
Temperature and Airflow (ATS030A0X3-SRH).
OUTPUT CURRENT, Io (A)
AMBIENT TEMPERATURE, TA OC
Figure 9. Derating Output Current versus Ambient
Temperature and Airflow (ATS030A0X3-SR).
70
75
80
85
90
95
0 5 10 15 20 25 30
Vin = 12 V
Vin = 6 V
Vin = 14 V
0
5
10
15
20
25
30
35
35 45 55 65 75 85
0.5m/s
(100LFM)
1m/s
(200LFM)
1.5m/s
(300LFM)
2.0m/s
(400LFM)
2.5m/s
(500LFM)
0
5
10
15
20
25
30
35
35 45 55 65 75 85
NC
0.5m/s
(100LFM)
1m/s
(200LFM)
1.5m/s
(300LFM)
2m/s
(400LFM)
2.5m/s
(500LFM)
Preliminary Data Sheet
Austin MegaLynx
TM
: Non-Isolated DC-DC Power Modules
4.5Vdc 5.5Vdc input; 0.8Vdc to 3.63Vdc output; 30A Output Current
6Vdc 14Vdc input; 0.8Vdc to 3.63Vdc output; 20/30A Output Current
January 20, 2016
©
2016 General Electric Company. All rights reserved. Page
8
Characteristic Curves
The following figures provide typical characteristics for the ATS030A0X3-SR and SRH (1.8V, 30A) at 25oC.
EFFICIENCY, η (%)
OUTPUT CURRENT, Io (A)
OUTPUT CURRENT, IO (A) AMBIENT TEMPERATURE, TA OC
Figure 10. Converter Efficiency versus Output Current.
Figure 13. Output Current Derating versus Ambient
Temperature and Airflow (ATS030A0X3-SRH).
OUTPUT VOLTAGE
VO (V) (20mV/div)
OUTPUT CURRENT, Io (A)
TIME, t (1µs/div) AMBIENT TEMPERATURE, TA OC
Figure 11. Typical output ripple and noise (V
IN
= V
IN,NOM
, I
o
=
Io,max).
Figure 14. Output Current Derating versus Ambient
Temperature and Airflow (ATS030A0X3-SR).
OUTPUT CURRENT, OUTPUT VOLTAGE
IO (A) (5A/div) VO (V) (100mV/div)
INPUT VOLTAGE OUTPUT VOLTAGE
VIN (V) (5V/div) VO (V) (1V/div)
TIME, t (20µs /div) TIME, t (5ms/div)
Figure 12. Transient Response to Dynamic Load Change
from 0% to 50% to 0% of full load with VIN =12V.
Figure 15. Typical Start-up Using Input Voltage (VIN = VIN,NOM,
Io = Io,max).
70
75
80
85
90
95
0 5 10 15 20 25 30
Vin = 12 V
Vin = 6 V
Vin = 14 V
0
5
10
15
20
25
30
35
35 45 55 65 75 85
0.5m/s
(100LFM)
1m/s
(200LFM)
1.5m/s
(300LFM)
2m/s
(400LFM)
2.5m/s
(500LFM)
0
5
10
15
20
25
30
35
35 45 55 65 75 85
NC
0.5m/s
(100LFM)
1m/s
(200LFM)
1.5m/s
(300LFM)
2m/s
(400LFM)
2.5m/s
(500LFM)
Preliminary Data Sheet
Austin MegaLynx
TM
: Non-Isolated DC-DC Power Modules
4.5Vdc 5.5Vdc input; 0.8Vdc to 3.63Vdc output; 30A Output Current
6Vdc 14Vdc input; 0.8Vdc to 3.63Vdc output; 20/30A Output Current
January 20, 2016
©
2016 General Electric Company. All rights reserved. Page
9
Characteristic Curves
The following figures provide typical characteristics for the ATS030A0X3-SR and -SRH (2.5V, 30A) at 25oC.
EFFICIENCY, η (%)
OUTPUT CURRENT, I
O
(A)
Figure 16. Converter Efficiency versus Output Current.
OUTPUT CURRENT, Io (A)
AMBIENT TEMPERATURE, TA OC
Figure 17. Derating Output Current versus Ambient
Temperature and Airflow (ATS030A0X3-SRH).
OUTPUT CURRENT, Io (A)
AMBIENT TEMPERATURE, TA OC
Figure 18. Derating Output Current versus Ambient
Temperature and Airflow (ATS030A0X3-SR).
70
75
80
85
90
95
100
0510 15 20 25 30
Vin = 12 V
Vin = 6 V
Vin = 14 V
0
5
10
15
20
25
30
35
35 45 55 65 75 85
NC
0.5m/s
(100LFM)
1m/s
(200LFM)
1.5m/s
(300LFM)
2m/s
(400LFM)
2.5m/s
(500LFM)
0
5
10
15
20
25
30
35 45 55 65 75 85
NC
0.5m/s
(100LFM)
1m/s
(200LFM)
1.5m/s
(300LFM)
2m/s
(400LFM)
2.5m/s
(500LFM)
Preliminary Data Sheet
Austin MegaLynx
TM
: Non-Isolated DC-DC Power Modules
4.5Vdc 5.5Vdc input; 0.8Vdc to 3.63Vdc output; 30A Output Current
6Vdc 14Vdc input; 0.8Vdc to 3.63Vdc output; 20/30A Output Current
January 20, 2016
©
2016 General Electric Company. All rights reserved. Page
10
Characteristic Curves
The following figures provide typical characteristics for the ATS020A0X3-SR and SRH (3.3V, 20A) at 25oC.
EFFICIENCY, η (%)
OUTPUT CURRENT, Io (A)
OUTPUT CURRENT, I
O
(A)
AMBIENT TEMPERATURE, T
A
O
C
Figure 19. Converter Efficiency versus Output Current.
Figure 22. Output Current Derating versus Ambient
Temperature and Airflow (ATS020A0X3-SRH).
OUTPUT VOLTAGE
VO (V) (20mV/div)
OUTPUT CURRENT, Io (A)
TIME, t (1µs/div)
AMBIENT TEMPERATURE, T
A
O
C
Figure 20. Typical output ripple and noise (VIN = VIN,NOM, Io =
Io,max).
Figure 23. Output Current Derating versus Ambient
Temperature and Airflow (ATS020A0X3-SR).
OUTPUT CURRENT, OUTPUT VOLTAGE
IO (A) (5A/div) VO (V) (100mV/div)
INPUT VOLTAGE OUTPUT VOLTAGE
VIN (V) (5V/div) VO (V) (1V/div)
TIME, t (20µs /div)
TIME, t (5ms/div)
Figure 21. Transient Response to Dynamic Load Change
from 0% to 50% of full load with VIN =12V.
Figure 24. Typical Start-up Using Input Voltage (VIN = VIN,NOM,
Io = Io,max).
70
75
80
85
90
95
100
0510 15 20
Vin = 12 V
Vin = 6 V
Vin = 14 V
0
5
10
15
20
25
30 40 50 60 70 80
NC
0.5m/s
(100LFM)
1m/s
(200LFM)
1.5m/s
(300LFM)
2m/s
(400LFM)
2.5m/s
(500LFM)
0
5
10
15
20
25
30 40 50 60 70 80
NC
0.5m/s
(100LFM)
1m/s
(200LFM)
1.5m/s
(300LFM)
2m/s
(400LFM)
2.5m/s
(500LFM)
Preliminary Data Sheet
Austin MegaLynx
TM
: Non-Isolated DC-DC Power Modules
4.5Vdc 5.5Vdc input; 0.8Vdc to 3.63Vdc output; 30A Output Current
6Vdc 14Vdc input; 0.8Vdc to 3.63Vdc output; 20/30A Output Current
January 20, 2016
©
2016 General Electric Company. All rights reserved. Page
11
Characteristic Curves
The following figures provide typical characteristics for the ATH030A0X3-SR and SRH (0.8V, 30A) at 25oC.
EFFICIENCY, η (%)
OUTPUT CURRENT, Io (A)
OUTPUT CURRENT, IO (A) AMBIENT TEMPERATURE, TA OC
Figure 25. Converter Efficiency versus Output Current.
Figure 28. Derating Output Current versus Ambient
Temperature and Airflow (ATS030A0X3-SRH).
OUTPUT VOLTAGE
VO (V) (20mV/div)
OUTPUT CURRENT, Io (A)
TIME, t (1µs/div)
AMBIENT TEMPERATURE, T
A
O
C
Figure 26. Typical output ripple and noise (V
IN
= V
IN,NOM
, I
o
=
Io,max).
Figure 29. Derating Output Current versus Ambient
Temperature and Airflow (ATH030A0X3-SR).
OUTPUT CURRENT, OUTPUT VOLTAGE
IO (A) (5A/div) VO (V) (100mV/div)
INPUT VOLTAGE OUTPUT VOLTAGE
VIN (V) (2V/div) VO (V) (1V/div)
TIME, t (10µs /div) TIME, t (2ms/div)
Figure 27. Transient Response to Dynamic Load Change
from 0% to 50% of full load with VIN =5V.
Figure 30. Typical Start-up Using Input Voltage (V
IN
= V
IN,NOM
,
Io = Io,max).
75
80
85
90
95
0510 15 20 25 30
Vin = 4. 5 V
Vin = 5. 0 V
Vin = 5. 5 V
0
5
10
15
20
25
30
35
35 45 55 65 75 85
0.5m/s
(100LFM)
1m/s
(200LFM)
1.5m/s
(300LFM)
2.0m/s
(400LFM)
2.5m/s
(500LFM)
0
5
10
15
20
25
30
35
35 45 55 65 75 85
0.5m/s
(100LFM)
1m/s
(200LFM)
1.5m/s
(300LFM)
2.0m/s
(400LFM)
2.5m/s
(500LFM)
Preliminary Data Sheet
Austin MegaLynx
TM
: Non-Isolated DC-DC Power Modules
4.5Vdc 5.5Vdc input; 0.8Vdc to 3.63Vdc output; 30A Output Current
6Vdc 14Vdc input; 0.8Vdc to 3.63Vdc output; 20/30A Output Current
January 20, 2016
©
2016 General Electric Company. All rights reserved. Page
12
Characteristic Curves
The following figures provide typical characteristics for the ATH030A0X3-SR and SRH (1.8V, 30A) at 25oC.
EFFICIENCY, η (%)
OUTPUT CURRENT, Io (A)
OUTPUT CURRENT, IO (A) AMBIENT TEMPERATURE, TA OC
Figure 31. Converter Efficiency versus Output Current.
Figure 34. Derating Output Current versus Ambient
Temperature and Airflow (ATH030A0X3-SRH).
OUTPUT VOLTAGE
VO (V) (20mV/div)
OUTPUT CURRENT, Io (A)
TIME, t (1
µ
s/div)
AMBIENT TEMPERATURE, T
A
O
C
Figure 32. Typical output ripple and noise (V
IN
= V
IN,NOM
, I
o
=
Io,max).
Figure 35. Derating Output Current versus Ambient
Temperature and Airflow (ATH030A0X3-SR).
OUTPUT CURRENT, OUTPUT VOLTAGE
IO (A) (5A/div) VO (V) (100mV/div)
INPUT VOLTAGE OUTPUT VOLTAGE
VIN (V) (2V/div) VO (V) (0.5V/div)
TIME, t (10µs /div) TIME, t (2ms/div)
Figure 33. Transient Response to Dynamic Load Change
from 0% to 50% of full load with VIN =5V.
Figure 36. Typical Start-up Using Input Voltage (V
IN
=
VIN,NOM, Io = Io,max).
75
80
85
90
95
0 5 10 15 20 25 30
Vin = 4. 5 V
Vin = 5. 0 V
Vin = 5. 5 V
0
5
10
15
20
25
30
35
35 45 55 65 75 85
0.5m/s
100LFM
1m/s
200LFM
1.5m/s
300LFM
2m/s
400LFM
2.5m/s
500LFM
0
5
10
15
20
25
30
35
35 45 55 65 75 85
0.5m/s
(100LFM)
1m/s
(200LFM)
1.5m/s
(300LFM)
2m/s
(400LFM)
2.5m/s
(500LFM)
Preliminary Data Sheet
Austin MegaLynx
TM
: Non-Isolated DC-DC Power Modules
4.5Vdc 5.5Vdc input; 0.8Vdc to 3.63Vdc output; 30A Output Current
6Vdc 14Vdc input; 0.8Vdc to 3.63Vdc output; 20/30A Output Current
January 20, 2016
©
2016 General Electric Company. All rights reserved. Page
13
Characteristic Curves
The following figures provide typical characteristics for the ATH030A0X3-SR and SRH (3.3V, 30A) at 25oC.
EFFICIENCY, η (%)
OUTPUT CURRENT, Io (A)
OUTPUT CURRENT, IO (A) AMBIENT TEMPERATURE, TA OC
Figure 37. Converter Efficiency versus Output Current.
Figure 40. Derating Output Current versus Ambient
Temperature and Airflow (ATH030A0X3-SRH).
OUTPUT VOLTAGE
VO (V) (20mV/div)
OUTPUT CURRENT, Io (A)
TIME, t (1µs/div) AMBIENT TEMPERATURE, TA OC
Figure 38. Typical output ripple and noise (V
IN
= V
IN,NOM
, I
o
=
Io,max).
Figure 41. Derating Output Current versus Ambient
Temperature and Airflow (ATH030A0X3-SR).
OUTPUT CURRENT, OUTPUT VOLTAGE
IO (A) (10A/div) VO (V) (100mV/div)
INPUT VOLTAGE OUTPUT VOLTAGE
VIN (V) (2V/div) VO (V) (1V/div)
TIME, t (10µs /div) TIME, t (2ms/div)
Figure 39. Transient Response to Dynamic Load Change
from 0% to 50% of full load with VIN =5V.
Figure 42. Typical Start-up Using Input Voltage (V
IN
=
VIN,NOM, Io = Io,max).
75
80
85
90
95
100
0510 15 20 25 30
Vin = 4. 5 V
Vin = 5. 0 V
Vin = 5. 5 V
0
5
10
15
20
25
30
35
35 45 55 65 75 85
0.5m/s
(100LFM)
1m/s
(200LFM)
1.5m/s
(300LFM)
2m/s
(400LFM)
2.5m/s
(500LFM)
0
5
10
15
20
25
30
35
35 45 55 65 75 85
0.5m/s
100LFM
1m/s
200LFM
1.5m/s
300LFM
2m/s
400LFM
2.5m/s
500LFM
Preliminary Data Sheet
Austin MegaLynx
TM
: Non-Isolated DC-DC Power Modules
4.5Vdc – 5.5Vdc input; 0.8Vdc to 3.63Vdc output; 30A Output Current
6Vdc 14Vdc input; 0.8Vdc to 3.63Vdc output; 20/30A Output Current
January 20, 2016
©
2016 General Electric Company. All rights reserved. Page
14
Test Configurations
TO OSCILLOSCOPE
CURRENT PROBE
LTEST
1μH
BATTERY
CS 220μF
E.S.R.<0.1
@ 20°C 100kHz
Min
150μF
VIN(+)
COM
NOTE: Measure input reflected ripple current with a simulated
source inductance (L
TEST
) of 1μH. Capacitor C
S
of fsets
possible battery impedance. Measure current as shown
above.
CIN
Figure 43. Input Reflected Ripple Current Test Setup.
NOTE: All voltage measurem ents to be taken at the module
terminals, as shown above. If sockets are used then
Kelvin connections are required at the module terminals
to avoid measurement errors due to socket contact
resistance.
V
O
(+)
COM
1uF
.
RESISTIVE
LOAD
SCOPE
COPPER STRIP
GROUND PLANE
10uF
Figure 44. Output Ripple and Noise Test Setup.
V
O
COM
V
IN
(+)
COM
R
LOAD
R
contact
R
distribution
R
contact
R
distribution
R
contact
R
contact
R
distribution
R
distribution
V
IN
V
O
NOTE: All voltage measurements to be taken at the module
terminals, as shown above. If sockets are used then
Kelvi n c onnec ti ons are r equ ired at the m odu l e t ermi n als
to avoi d m eas urem en t errors du e t o s oc k et c ontact
resistance.
Figure 45. Output Voltage and Efficiency Test Setup.
η
=
V
O
.
I
O
V
IN
.
I
IN
x
100
%
Efficiency
Design Considerations
The Austin MegaLynxTM module should be connected to a
low-impedance source. A highly inductive source can affect
the stability of the module. An input capacitor must be
placed directly adjacent to the input pin of the module, to
minimize input ripple voltage and ensure module stability.
To minimize input voltage ripple, low-ESR ceramic
capacitors are recommended at the input of the module.
Figure 46 shows the input ripple voltage for various output
voltages at 30A of load current with 1x22 µF or 2x22 µF
ceramic capacitors and an input of 12V. Figure 47 shows
data for the 5Vin case, with 2x22µF and 2x47µF of ceramic
capacitors at the input, and for a load current of 30A.
Input Ripple Voltage (mVp-p)
Output Voltage (Vdc)
Figure 46. Input ripple voltage for various output
voltages with 1x22 µF or 2x22 µF ceramic capacitors at
the input (30A load). Input voltage is 12V.
Input Ripple Voltage (mVp-p)
Output Voltage (Vdc)
Figure 47. Input ripple voltage in mV, p-p for various
output voltages with 2x22 µF or 2x47 µF ceramic
capacitors at the input (30A load). Input voltage is 5V.
0
50
100
150
200
250
300
350
0.5 11.5 22.5
1 x 22uF
2 x 22uF
0
20
40
60
80
100
120
0.5 11.5 22.5 33.5
2 x 22uF
2 x 47uF
Preliminary Data Sheet
Austin MegaLynx
TM
: Non-Isolated DC-DC Power Modules
4.5Vdc 5.5Vdc input; 0.8Vdc to 3.63Vdc output; 30A Output Current
6Vdc 14Vdc input; 0.8Vdc to 3.63Vdc output; 20/30A Output Current
January 20, 2016
©
2016 General Electric Company. All rights reserved. Page
15
Output Filtering
The Austin MegaLynxTM modules are designed for low output
ripple voltage and will meet the maximum output ripple
specification with 0.1 µF ceramic and 10 µF ceramic
capacitors at the output of the module. However, additional
output filtering may be required by the system designer for
a number of reasons. First, there may be a need to further
reduce the output ripple and noise of the module. Second,
the dynamic response characteristics may need to be
customized to a particular load step change.
To reduce the output ripple and improve the dynamic
response to a step load change, additional capacitance at
the output can be used. Low ESR polymer and ceramic
capacitors are recommended to improve the dynamic
response of the module. Figure 48 shows the output ripple
voltage for various output voltages at 30A of load current
with different external capacitance values and an input of
12V. Figure 49 shows data for the 5Vin case for various
output voltages at 30A of load current with different
external capacitance values. For stable operation of the
module, limit the capacitance to less than the maximum
output capacitance as specified in the electrical
specification table.
Figure 48. Output ripple voltage for various output
voltages with external 1x10 µF, 1x47 µF, 2x47 µF or 4x47
µF ceramic capacitors at the output (30A load). Input
voltage is 12V.
Figure 49. Output ripple voltage for various output
voltages with external 1x10 µF, 1x47 µF, 2x47 µF or 4x47
µF ceramic capacitors at the output (30A load). Input
voltage is 5V.
Safety Considerations
For safety agency approval the power module must be
installed in compliance with the spacing and separation
requirements of the end-use safety agency standards, i.e.,
UL 60950, CSA C22.2 No. 60950-00, EN60950 (VDE 0850)
(IEC60950, 3rd edition) Licensed.
For the converter output to be considered meeting the
requirements of safety extra-low voltage (SELV), the input
must meet SELV requirements. The power module has
extra-low voltage (ELV) outputs when all inputs are ELV.
Feature Descriptions
Remote On/Off
The Austin MegaLynxTM SMT power modules feature a
On/Off pin for remote On/Off operation. If not using the
On/Off pin, connect the pin to ground (the module will be
ON). The On/Off signal (Von/off) is referenced to ground. Circuit
configuration for remote On/Off operation of the module
using the On/Off pin is shown in Figure 50.
During a Logic High on the On/Off pin (transistor Q1 is OFF),
the module remains OFF. The external resistor R1 should be
chosen to maintain 3.0V minimum on the On/Off pin to
ensure that the module is OFF when transistor Q1 is in the
OFF state. Suitable values for R1 are 4.7K for input voltage
of 12V and 3K for 5Vin. During Logic-Low when Q1 is turned
ON, the module is turned ON. The ATS030A0X3-62SRHZ and
ATS030A0X3-62SRPHZ modules have a higher value resistor
of 100K connected internally between the gate and source
of the internal FET used to control the PWM Enable line.
The On/Off pin can also be used to synchronize the output
voltage start-up and shutdown of multiple modules in
parallel. By connecting On/Off pins of multiple modules, the
output start-up can be synchronized (please refer to
characterization curves). When On/Off pins are connected
together, all modules will shutdown if any one of the
modules gets disabled due to undervoltage lockout or over
temperature protection.
0
10
20
30
40
50
60
70
80
90
100
110
0.5 11.5 22.5
O ut put Vol tage(Vol t s )
Ripple(mVp-p)
1x10uF External Cap
1x47uF External Cap
2x47uF External Cap
4x47uF External Cap
5
15
25
0.5 11.5 22.5
O ut put Vol tage(Vol t s )
Ripple(mVp-p)
1x10uF External Cap
1x47uF External Cap
2x47uF External Cap
4x47uF External Cap
Preliminary Data Sheet
Austin MegaLynx
TM
: Non-Isolated DC-DC Power Modules
4.5Vdc – 5.5Vdc input; 0.8Vdc to 3.63Vdc output; 30A Output Current
6Vdc 14Vdc input; 0.8Vdc to 3.63Vdc output; 20/30A Output Current
January 20, 2016
©
2016 General Electric Company. All rights reserved. Page
16
Figure 50. Remote On/Off Implementation using
ON/OFF .
Remote Sense
The Austin MegaLynxTM SMT power modules have a Remote
Sense feature to minimize the effects of distribution losses
by regulating the voltage at the Remote Sense pin (See
Figure 51). The voltage between the Sense pin and Vo pin
must not exceed 0.5V.
The amount of power delivered by the module is defined as
the output voltage multiplied by the output current (Vo x Io).
When using Remote Sense, the output voltage of the
module can increase, which, if the same output is
maintained, increases the power output by the module.
Make sure that the maximum output power of the module
remains at or below the maximum rated power. When the
Remote Sense feature is not being used, connect the
Remote Sense pin to output of the module.
V
O
COM
V
IN
(+)
COM
R
LOAD
R
contact
R
distribution
R
contact
R
distribution
R
contact
R
contact
R
distribution
R
distribution
Sense
Figure 51. Effective Circuit Configuration for
Remote Sense operation.
Over Current Protection
To provide protection in a fault (output overload) condition,
the unit is equipped with internal current-limiting circuitry
and can endure current limiting continuously. At the point of
current-limit inception, the unit enters hiccup mode. The unit
operates normally once the output current is brought back
into its specified range. The average output current during
hiccup is 10% IO, max.
Over Temperature Protection
To provide protection in a fault condition, the unit is
equipped with a thermal shutdown circuit. The unit will
shutdown if the overtemperature threshold of 125oC is
exceeded at the thermal reference point Tref. The thermal
shutdown is not intended as a guarantee that the unit will
survive temperatures beyond its rating. Once the unit goes
into thermal shutdown it will then wait to cool before
attempting to restart.
Input Under Voltage Lockout
At input voltages below the input undervoltage lockout limit,
the module operation is disabled. The module will begin to
operate at an input voltage above the undervoltage lockout
turn-on threshold.
Output Voltage Programming
The output voltage of the Austin MegaLynxTM can be
programmed to any voltage from 0.8dc to 3.63Vdc by
connecting a resistor (shown as Rtrim in Figure 52) between
Trim and GND pins of the module. Without an external
resistor between Trim and GND pins, the output of the
module will be 0.8Vdc. To calculate the value of the trim
resistor, Rtrim for a desired output voltage, use the following
equation:
=100
80.0
1200
Vo
R
trim
Rtrim is the external resistor in Ω
Vo is the desired output voltage
By using a ±0.5% tolerance trim resistor with a TC of
±100ppm, a set point tolerance of ±1.5% can be achieved as
specified in the electrical specification. Table 1 provides
Rtrim values required for some common output voltages.
The POL Programming Tool, available at
www.gecriticalpower.com under the Design Tools section,
helps determine the required external trim resistor needed
for a specific output voltage.
V
O
(+)
TRIM
GND
LOAD
V
IN
(+)
ON/OFF
Rtrim
Figure 52. Circuit configuration to program output
voltage using an external resistor.
Table 1
Q1
GND
PW M Enable
ON/OFF
VIN+
ON/OFF
_
+
V
I
MODULE
R1
ON/OFF
100K
Therm al SD
1K
10K
Preliminary Data Sheet
Austin MegaLynx
TM
: Non-Isolated DC-DC Power Modules
4.5Vdc 5.5Vdc input; 0.8Vdc to 3.63Vdc output; 30A Output Current
6Vdc 14Vdc input; 0.8Vdc to 3.63Vdc output; 20/30A Output Current
January 20, 2016
©
2016 General Electric Company. All rights reserved. Page
17
VO, set (V)
Rtrim (KΩ)
0.8
Open
1.0
5.900
1.2
2.900
1.5
1.614
1.8
1.100
2.5
0.606
3.3
0.380
Voltage Margining
Output voltage margining can be implemented in the Austin
MegaLynxTM modules by connecting a resistor, Rmargin-up,
from the Trim pin to the ground pin for margining-up the
output voltage and by connecting a resistor, Rmargin-down,
from the Trim pin to output pin for margining-down. Figure
53 shows the circuit configuration for output voltage
margining. The POL Programming Tool, available at
www.gecriticalpower.com under the Design Tools section,
also calculates the values of Rmargin-up and Rmargin-down for a
specific output voltage and % margin. Please consult your
local GE technical representative for additional details.
Figure 53. Circuit Configuration for margining Output
voltage.
Voltage Sequencing
The Austin MegaLynxTM series of modules include a
sequencing feature that enables users to implement various
types of output voltage sequencing in their applications. This
is accomplished via an additional sequencing pin. When not
using the sequencing feature, either leave the SEQ pin
unconnected or tied to VIN.
For proper voltage sequencing, first, input voltage is applied
to the module. The On/Off pin of the module is or tied to
GND so that the module is ON by default. After applying
input voltage to the module, a delay of 10msec minimum is
required before applying voltage on the SEQ pin. During this
delay time, the SEQ pin should be kept at a voltage of 50mV
(± 20 mV). After the 10msec delay, the voltage applied to the
SEQ pin is allowed to vary and the output voltage of the
module will track this voltage on a one-to-one volt basis
until the output reaches the set-point voltage. To initiate
simultaneous shutdown of the modules, the SEQ pin voltage
is lowered in a controlled manner. The output voltages of
the modules track the sequence pin voltage when it falls
below their set-point voltages. A valid input voltage must be
maintained until the tracking and output voltages reach
zero to ensure a controlled shutdown of the modules. For a
more detailed description of sequencing, please refer to
Application Note AN04-008 titled “Guidelines for
Sequencing of Multiple Modules”.
When using the EZ-SEQUENCETM feature to control start-up
of the module, pre-bias immunity feature during start-up is
disabled. The pre-bias immunity feature of the module
relies on the module being in the diode-mode during start-
up. When using the EZ-SEQUENCETM feature, modules goes
through an internal set-up time of 10msec, and will be in
synchronous rectification mode when voltage at the SEQ pin
is applied. This will result in sinking current in the module if
pre-bias voltage is present at the output of the module.
When pre-bias immunity during start-up is required, the EZ-
SEQUENCETM feature must be disabled.
Active Load Sharing (-P Option)
For additional power requirements, the Austin MegaLynx
series power module is also available with a parallel option.
Up to five modules can be configured, in parallel, with active
load sharing. Good layout techniques should be observed
when using multiple units in parallel. To implement forced
load sharing, the following connections should be made:
The share pins of all units in parallel must be connected
together. The path of these connections should be as
direct as possible.
All remote-sense pins should be connected to the
power bus at the same point, i.e., connect all the
SENSE(+) pins to the (+) side of the bus. Close proximity
and directness are necessary for good noise immunity
Some special considerations apply for design of converters
in parallel operation:
When sizing the number of modules required for
parallel operation, take note of the fact that current
sharing has some tolerance. In addition, under
transient condtions such as a dynamic load change
and during startup, all converter output currents will
not be equal. To allow for such variation and avoid the
likelihood of a converter shutting off due to a current
overload, the total capacity of the paralleled system
should be no more than 75% of the sum of the
individual converters. As an example, for a system of
four ATS030A0X3-SR converters the parallel, the total
Vo
Austin Lynx or
Lynx II Series
GND
Trim
Q1
Rtrim
Rmargin-up
Q2
Rmargin-down
Preliminary Data Sheet
Austin MegaLynx
TM
: Non-Isolated DC-DC Power Modules
4.5Vdc – 5.5Vdc input; 0.8Vdc to 3.63Vdc output; 30A Output Current
6Vdc 14Vdc input; 0.8Vdc to 3.63Vdc output; 20/30A Output Current
January 20, 2016
©
2016 General Electric Company. All rights reserved. Page
18
current drawn should be less that 75% of (4 x 30A) , i.e.
less than 90A.
All modules should be turned on and off together. This
is so that all modules come up at the same time
avoiding the problem of one converter sourcing current
into the other leading to an overcurrent trip condition.
To ensure that all modules come up simultaneously, the
on/off pins of all paralleled converters should be tied
together and the converters enabled and disabled
using the on/off pin.
The share bus is not designed for redundant operation
and the system will be non-functional upon failure of
one of the unit when multiple units are in parallel. In
particular, if one of the converters shuts down during
operation, the other converters may also shut down
due to their outputs hitting current limit. In such a
situation, unless a coordinated restart is ensured, the
system may never properly restart since different
converters will try to restart at different times causing
an overload condition and subsequent shutdown. This
situation can be avoided by having an external output
voltage monitor circuit that detects a shutdown
condition and forces all converters to shut down and
restart together.
Preliminary Data Sheet
Austin MegaLynx
TM
: Non-Isolated DC-DC Power Modules
4.5Vdc 5.5Vdc input; 0.8Vdc to 3.63Vdc output; 30A Output Current
6Vdc 14Vdc input; 0.8Vdc to 3.63Vdc output; 20/30A Output Current
January 20, 2016
©
2016 General Electric Company. All rights reserved. Page
19
Thermal Considerations
Power modules operate in a variety of thermal
environments; however, sufficient cooling should always be
provided to help ensure reliable operation.
Considerations include ambient temperature, airflow,
module power dissipation, and the need for increased
reliability. A reduction in the operating temperature of the
module will result in an increase in reliability. The thermal
data presented here is based on physical measurements
taken in a wind tunnel. The test set-up is shown in Figure
54. Note that the airflow is parallel to the short axis of the
module as shown in Figure 55. The derating data applies to
airflow in either direction of the module’s long axis.
Figure 54. Thermal Test Setup.
The thermal reference points, Tref used in the specifications
are shown in Figure 56. For reliable operation the
temperatures at these points should not exceed 125oC. The
output power of the module should not exceed the rated
power of the module (Vo,set x Io,max).
Please refer to the Application NoteThermal
Characterization Process For Open-Frame Board-Mounted
Power Modules” for a detailed discussion of thermal
aspects including maximum device temperatures.
Figure 55. Airflow direction for thermal testing.
Figure 56. Tref Temperature measurement location.
Air
flow
x
Power Module
Wind Tunnel
PWBs
12.7_
(0.50)
76.2_
(3.0)
Probe Location
for measuring
airflow and
ambient
temperature
25.4_
(1.0)
Preliminary Data Sheet
Austin MegaLynx
TM
: Non-Isolated DC-DC Power Modules
4.5Vdc 5.5Vdc input; 0.8Vdc to 3.63Vdc output; 30A Output Current
6Vdc 14Vdc input; 0.8Vdc to 3.63Vdc output; 20/30A Output Current
January 20, 2016
©
2016 General Electric Company. All rights reserved. Page
20
Mechanical Outline of Module (ATH030A0X3-SRPH/ATS030/020A0X3-SRPH)
Dimensions are in millimeters and (inches).
Tolerances: x.x mm ± 0.5 mm (x.xx in. ± 0.02 in.) [unless otherwise indicated]
x.xx mm ± 0.25 mm (x.xxx in ± 0.010 in.)
COPLANARITY SHALL BE DEFINED AS WHEN THE MODULE IS PLACED ONTO A FLAT SURFACE, THE CONTACTING SURFACE
SHALL NOT BE MORE THAN 0 004"
Note: For the ATH030A0X3-SRH and ATS030/020A0X3-SRH modules, the SHARE pin is omitted since these modules are not
capable of being paralleled.
Preliminary Data Sheet
Austin MegaLynx
TM
: Non-Isolated DC-DC Power Modules
4.5Vdc 5.5Vdc input; 0.8Vdc to 3.63Vdc output; 30A Output Current
6Vdc 14Vdc input; 0.8Vdc to 3.63Vdc output; 20/30A Output Current
January 20, 2016
©
2016 General Electric Company. All rights reserved. Page
21
Recommended Pad Layout (ATH030A0X3-SRPH/ATS030/020A0X3-SRPH)
Dimensions are in millimeters and (inches).
Tolerances: x.x mm ± 0.5 mm (x.xx in. ± 0.02 in.) [unless otherwise indicated]
x.xx mm ± 0.25 mm (x.xxx in ± 0.010 in.)
Note: For the ATH030A0X3-SRH and ATS030/020A0X3-SRH modules, the SHARE pin is omitted since these modules
are not capable of being paralleled.
PIN
FUNCTION
PIN
FUNCTION
1
On/Off
6
Trim
2
V
IN
7
Sense
3
SEQ
8
GND
4
GND
9
SHARE
5
V
OUT
10
GND
Pin 8
Pin 10
Preliminary Data Sheet
Austin MegaLynx
TM
: Non-Isolated DC-DC Power Modules
4.5Vdc 5.5Vdc input; 0.8Vdc to 3.63Vdc output; 30A Output Current
6Vdc 14Vdc input; 0.8Vdc to 3.63Vdc output; 20/30A Output Current
January 20, 2016
©
2016 General Electric Company. All rights reserved. Page
22
Mechanical Outline of Module (ATH030A0X3-SRP/ATS030/020A0X3-SRP)
Dimensions are in millimeters and (inches).
Tolerances: x.x mm ± 0.5 mm (x.xx in. ± 0.02 in.) [unless otherwise indicated]
x.xx mm ± 0.25 mm (x.xxx in ± 0.010 in.)
.
COPLANARITY SHALL BE DEFINED AS WHEN THE MODULE IS PLACED ONTO A FLAT SURFACE, THE CONTACTING SURFACE
SHALL NOT BE MORE THAN 0 004"
Preliminary Data Sheet
Austin MegaLynx
TM
: Non-Isolated DC-DC Power Modules
4.5Vdc 5.5Vdc input; 0.8Vdc to 3.63Vdc output; 30A Output Current
6Vdc 14Vdc input; 0.8Vdc to 3.63Vdc output; 20/30A Output Current
January 20, 2016
©
2016 General Electric Company. All rights reserved. Page
23
Recommended Pad Layout (ATH030A0X3-SRP/ATS030/020A0X3-SRP)
Dimensions are in millimeters and (inches).
Tolerances: x.x mm ± 0.5 mm (x.xx in. ± 0.02 in.) [unless otherwise indicated]
x.xx mm ± 0.25 mm (x.xxx in ± 0.010 in.)
Note: For the ATH030A0X3-SR and ATS030/020A0X3-SR modules, the SHARE pin is omitted since these modules are
not capable of being paralleled.
PIN
FUNCTION
PIN
FUNCTION
1
On/Off
6
Trim
2
V
IN
7
Sense
3
SEQ
8
No Pin
4
GND
9
Share
5
V
OUT
10
No Pin
Preliminary Data Sheet
Austin MegaLynx
TM
: Non-Isolated DC-DC Power Modules
4.5Vdc 5.5Vdc input; 0.8Vdc to 3.63Vdc output; 30A Output Current
6Vdc 14Vdc input; 0.8Vdc to 3.63Vdc output; 20/30A Output Current
January 20, 2016
©
2016 General Electric Company. All rights reserved. Page
24
Packaging Details
The Austin MegaLynxTM SMT version is supplied in tape & reel as standard. Modules are shipped in quantities of 200 modules per
reel.
All Dimensions are in millimeters and (in inches).
Reel Dimensions
Outside diameter: 330.2 (13.0)
Inside diameter: 177.8 (7.0)
Tape Width: 44.0 (1.73)
Preliminary Data Sheet
Austin MegaLynx
TM
: Non-Isolated DC-DC Power Modules
4.5Vdc 5.5Vdc input; 0.8Vdc to 3.63Vdc output; 30A Output Current
6Vdc 14Vdc input; 0.8Vdc to 3.63Vdc output; 20/30A Output Current
January 20, 2016
©
2016 General Electric Company. All rights reserved. Page
25
Surface Mount Information
Pick and Place
The Austin MegaLynxTM SMT modules use an open frame
construction and are designed for a fully automated
assembly process. The modules are fitted with a label
designed to provide a large surface area for pick and place
operations. The label meets all the requirements for surface
mount processing, as well as safety standards, and is able
to withstand reflow temperatures of up to 300oC. The label
also carries product information such as product code,
serial number and location of manufacture.
Figure 57. Pick and Place Location.
Nozzle Recommendations
The module weight has been kept to a minimum by using
open frame construction. Even so, these modules have a
relatively large mass when compared to conventional SMT
components. Variables such as nozzle size, tip style,
vacuum pressure and pick & placement speed should be
considered to optimize this process. The minimum
recommended inside nozzle diameter for reliable operation
is 3mm. The maximum nozzle outer diameter, which will
safely fit within the allowable component spacing, is 5 mm
max.
Tin Lead Soldering
The Austin MegaLynxTM SMT power modules are lead free
modules and can be soldered either in a lead-free solder
process or in a conventional Tin/Lead (Sn/Pb) process. It is
recommended that the customer review data sheets in
order to customize the solder reflow profile for each
application board assembly. The following instructions must
be observed when soldering these units. Failure to observe
these instructions may result in the failure of or cause
damage to the modules, and can adversely affect long-term
reliability.
In a conventional Tin/Lead (Sn/Pb) solder process peak
reflow temperatures are limited to less than 235oC.
Typically, the eutectic solder melts at 183oC, wets the land,
and subsequently wicks the device connection. Sufficient
time must be allowed to fuse the plating on the connection
to ensure a reliable solder joint. There are several types of
SMT reflow technologies currently used in the industry.
These surface mount power modules can be reliably
soldered using natural forced convection, IR (radiant
infrared), or a combination of convection/IR. For reliable
soldering the solder reflow profile should be established by
accurately measuring the modules CP connector
temperatures.
REFLOW TEMP (°C)
REFLOW TIME (S)
Figure 58. Reflow Profile for Tin/Lead (Sn/Pb) process.
MAX TEMP SOLDER (°C)
Figure 59. Time Limit Curve Above 205oC Reflow for Tin
Lead (Sn/Pb) process.
Preliminary Data Sheet
Austin MegaLynx
TM
: Non-Isolated DC-DC Power Modules
4.5Vdc 5.5Vdc input; 0.8Vdc to 3.63Vdc output; 30A Output Current
6Vdc 14Vdc input; 0.8Vdc to 3.63Vdc output; 20/30A Output Current
January 20, 2016
©
2016 General Electric Company. All rights reserved. Page
26
Surface Mount Information (continued)
Lead Free Soldering
The Z version MegaLynx SMT modules are lead-free (Pb-
free) and RoHS compliant and are both forward and
backward compatible in a Pb-free and a SnPb soldering
process. Failure to observe the instructions below may result
in the failure of or cause damage to the modules and can
adversely affect long-term reliability.
Pb-free Reflow Profile
Power Systems will comply with J-STD-020 Rev. C
(Moisture/Reflow Sensitivity Classification for Nonhermetic
Solid State Surface Mount Devices) for both Pb-free solder
profiles and MSL classification procedures. This standard
provides a recommended forced-air-convection reflow
profile based on the volume and thickness of the package
(table 4-2). The suggested Pb-free solder paste is Sn/Ag/Cu
(SAC). The recommended linear reflow profile using Sn/Ag/Cu
solder is shown in Figure. 60.
MSL Rating
The Austin MegaLynxTM SMT modules have a MSL rating of
2a.
Storage and Handling
The recommended storage environment and handling
procedures for moisture-sensitive surface mount packages is
detailed in J-STD-033 Rev. A (Handling, Packing, Shipping and
Use of Moisture/Reflow Sensitive Surface Mount Devices).
Moisture barrier bags (MBB) with desiccant are required for
MSL ratings of 2 or greater. These sealed packages should
not be broken until time of use. Once the original package is
broken, the floor life of the product at conditions of <= 30°C
and 60% relative humidity varies according to the MSL rating
(see J-STD-033A). The shelf life for dry packed SMT packages
will be a minimum of 12 months from the bag seal date,
when stored at the following conditions: < 40° C, < 90%
relative humidity.
Post Solder Cleaning and Drying Considerations
Post solder cleaning is usually the final circuit-board
assembly process prior to electrical board testing. The result
of inadequate cleaning and drying can affect both the
reliability of a power module and the testability of the
finished circuit-board assembly. For guidance on appropriate
soldering, cleaning and drying procedures, refer to Board
Mounted Power Modules: Soldering and Cleaning Application
Note (AN04-001).
Figure 60. Recommended linear reflow profile using
Sn/Ag/Cu solder
Per J-STD-020 Rev. C
0
50
100
150
200
250
300
Reflow Time (Seconds)
Ref low Temp (°C )
Heating Zone
1°C/Second
Peak Temp 260°C
* Min. Time Above 235°C
15 Seconds
*Time Above 217°C
60 Seconds
Cooling
Zone
Preliminary Data Sheet
Austin MegaLynx
TM
: Non-Isolated DC-DC Power Modules
4.5Vdc 5.5Vdc input; 0.8Vdc to 3.63Vdc output; 30A Output Current
6Vdc 14Vdc input; 0.8Vdc to 3.63Vdc output; 20/30A Output Current
Contact Us
For more information, call us at
USA/Canada:
+1 877 546 3243, or +1 972 244 9288
Asia-Pacific:
+86.021.54279977*808
Europe, Middle-East and Africa:
+49.89.878067-280
www.gecriticalpower.com
GE Critical Power reserves the right to make changes to the product(s) or information contained herein without notice, and no
liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s)
or information.
January 20, 2016 ©2016 General Electric Company. All International rights reserved. Version 1.18
Ordering Information
Table 2. Device Codes
Product codes Input Voltage Output Voltage Output Current
On/Off
Logic
Connector
Type
Comcodes
ATH030A0X3-SR 4.5 5.5Vdc 0.8 3.63Vdc 30A Negative SMT 108996625
ATH030A0X3-SRZ 4.5 5.5Vdc 0.8 3.63Vdc 30A Negative SMT CC109109550
ATH030A0X3-SRH 4.5 5.5Vdc 0.8 3.63Vdc 30A Negative SMT CC109102340
ATH030A0X3-SRHZ 4.5 5.5Vdc 0.8 3.63Vdc 30A Negative SMT CC109109567
ATH030A0X3-SRPH 4.5 5.5Vdc 0.8 3.63Vdc 30A Negative SMT 108996633
ATH030A0X3-SRPHZ 4.5 5.5Vdc 0.8 3.63Vdc 30A Negative SMT CC109109583
ATS030A0X3-SR 6.0 14Vdc 0.8 2.75Vdc 30A Negative SMT 108996591
ATS030A0X3-SRZ 6.0 14Vdc 0.82.75Vdc 30A Negative SMT CC109109591
ATS030A0X3-SRH 6.0 14Vdc 0.8 2.75Vdc 30A Negative SMT 108996600
ATS030A0X3-SRHZ 6.0 14Vdc 0.8 2.75Vdc 30A Negative SMT CC109109600
ATS030A0X3-SRPH 6.0 14Vdc 0.8 2.75Vdc 30A Negative SMT 108996617
ATS030A0X3-SRPHZ 6.0 14Vdc 0.8 2.75Vdc 30A Negative SMT CC109105285
ATS020A0X3-SR 6.0 14Vdc 0.8 3.63Vdc 20A Negative SMT CC109132544
ATS020A0X3-SRH 6.0 14Vdc 0.8 3.63Vdc 20A Negative SMT CC109132552
ATS020A0X3-SRPH 6.0 14Vdc 0.8 3.63Vdc 20A Negative SMT CC109132560
ATS020A0X3-SRZ 6.0 14Vdc 0.8 3.63Vdc 20A Negative SMT CC109132577
ATS020A0X3-SRHZ 6.0 14Vdc 0.8 3.63Vdc 20A Negative SMT CC109132585
ATS020A0X3-SRPHZ 6.0 14Vdc 0.8 3.63Vdc 20A Negative SMT CC109132593
ATS030A0X3-62SRHZ* 6.0 14Vdc 0.8 2.75Vdc 30A Negative SMT CC109139457
ATS030A0X3-62SRPHZ* 6.0 14Vdc 0.8 2.75Vdc 30A Negative SMT CC109140951
ATS030A0X3-42SRPHZ* 6.0 14Vdc 0.8 2.75Vdc 30A Negative SMT CC109145471
* Special codes, consult factory before ordering
Table 3. Device Options
Option
Device Code Suffix
Current Share
-P
2 Extra ground pins
-H
RoHS Compliant
-Z