RXC101 300-1000 MHz Receiver Complies with Directive 2002/95/EC (RoHS) Product Overview RXC101 is a highly integrated single chip, zero-IF, multi-channel, low power, high data rate RF receiver designed to operate in the unlicensed 315/433/868/915 MHz frequency bands. All critical RF and baseband functions are completely integrated in the chip, thus minimizing external component count and simplifying design-ins. Its small size with low power consumption makes it ideal for various short range radio applications. 16-TSSOP package The RXC101 supports two modes - Microcontroller mode and Standalone mode. In the Micro controller mode, the use of a generic 10MHz crystal and a low-cost microcontroller is all that is needed to create a complete Receiver link. Simple short range radio applications can be supported by using the RXC101 in the Standalone mode, which allows complete receiver operation without the use of a microcontroller. Key Features * * * * * * * * * * * * * * * * * * * * * * * * Modulation: FSK (Frequency Hopping Spread Spectrum capability) Limited OOK capability Operating frequency: 315/433/868/915 MHz High Sensitivity: (-112dBm) Low current consumption (RX current ~ 8mA) Wide Operating supply voltage: 2.2 to 5.4V Low standby current (0.1uA) FSK Data rate up to 256kbps Support for Multiple Channels * [315/433 Bands]: 95 Channels (100kHz) * [868 Band]: 190 Channels (100kHz) * [915 Band]: 285 Channels (100kHz) Generic 10MHz Xtal reference Processor or Standalone Operation Mode Automatic Frequency Alignment Programmable Analog/Digital Baseband Filter Programmable Data Rate Programmable Input LNA Gain Programmable Clock Output Frequency Programmable Wake-up Timer with programmable Duty Cycle Programmable Crystal Load Capacitance Programmable, Positive/Negative FSK Deviation Programmable Push Button Control Internal Valid Data Recognition Integrated PLL, IF & Baseband Circuitry Integrated Selectable Analog/Digital RSSI Integrated, Programmable Low Battery Voltage Detector www.RFM.com Email: info@rfm.com (c)by RF Monolithics, Inc. * * * * * * * * * * * Integrated Crystal Oscillator Integrated Clock Recovery Standard SPI interface External Wake-up Events External Processor Interrupt pin Receive FIFO or External Pin TTL/CMOS Compatible I/O pins No Manual Adjustment Needed for Production Very few external components requirement Small size plastic package: 16-pin TSSOP Standard 13 inch reel, 2000 pieces. Popular applications * * * * * * * * * * * * * * Remote control applications Active RFID tags Wireless PC Peripherals Automated Meter reading Home & Industrial Automation Security systems Remote keyless entry Automobile Immobilizers Sports & Performance monitoring Wireless Toys Medical equipment Low power two way telemetry systems Wireless mesh sensors Wireless modules Page 1 of 43 RXC101 - 4/8/08 Table of Contents 1. RXC101 Pin Description ........................................................................................... 3 1.1 Processor Mode Pin Configuration ...................................................................... 3 1.2 Simple Mode Pin Configuration............................................................................ 4 2. RXC101 Functional Description ............................................................................... 5 2.1 RXC101 Typical Application Circuit ..................................................................... 5 Processor Mode .................................................................................................. 5 Antenna Design Considerations........................................................................... 6 PCB Layout Considerations ................................................................................. 6 2.2 Simple Mode ........................................................................................................ 8 Simple Mode Functional Block Diagram .............................................................. 8 Duty Cycle Mode ............................................................................................... 10 3. RXC101 Functional Characteristics....................................................................... 11 Input Amplifier .......................................................................................................... 11 Baseband Data and Filtering.................................................................................... 11 Data Quality Detector (DQD) ................................................................................... 12 Valid Data Detector (DDET)..................................................................................... 12 Receiver FIFO.......................................................................................................... 12 Receive Signal Strength Indicator (RSSI) ................................................................ 13 Automatic Frequency Adjustment (AFA).................................................................. 13 Crystal Oscillator...................................................................................................... 13 Frequency Control (PLL) and Frequency Synthesizer ............................................. 14 Wake-Up Mode ........................................................................................................ 14 Duty Cycle Mode...................................................................................................... 14 Low Battery Detector ............................................................................................... 15 OOK Operation ........................................................................................................ 15 SPI Interface ............................................................................................................ 15 SPI Interface Timing................................................................................................ 15 4. Control and Configuration Registers .................................................................... 16 Status Register ....................................................................................................... 17 Configuration Register [POR=893Ah] ...................................................................... 18 Receiver Control Register [POR=C0C1h] ................................................................ 20 FIFO Configuration Register [POR=CE89h] ............................................................ 22 Automatic Frequency Adjust Register [POR=C6F7h] .............................................. 23 Baseband Filter Register [POR=C42Ch].................................................................. 25 Frequency Setting Register [POR=A680h] .............................................................. 26 Data Rate Setup Register [POR=C823h]................................................................. 27 Wake-up Timer Period Register [POR=E196h]........................................................ 28 Duty Cycle Set Register [POR=CC0Eh]................................................................... 29 Battery Detect Threshold and Clock Output Register [POR=C200h] ....................... 30 5. Maximum Ratings.................................................................................................... 31 Recommended Operating Ratings........................................................................... 31 6. DC Electrical Characteristics ................................................................................ 31 7. AC Electrical Characteristics ................................................................................ 32 8. Receiver Measurement Results ............................................................................ 34 Reflow Profile .............................................................................................................. 36 www.RFM.com Email: info@rfm.com (c)by RF Monolithics, Inc. Page 2 of 43 RXC101 - 4/8/08 9. Package Information .............................................................................................. 37 www.RFM.com Email: info@rfm.com (c)by RF Monolithics, Inc. Page 3 of 43 RXC101 - 4/8/08 1. Pin Description Processor Mode Pin 1 2 Name SDI SCK 3 nCS 4 nFINT/SDO 5 nIRQ 6 DATA/nFSEL 7 DCLK/FCAP/ FINT 8 ClkOut 9 Xtal/Ref 10 11 12 13 14 nRST GND RF_P RF_N VDD 15 RSSIA 16 DDET Description SPI Data In SPI Data Clock Chip Select Input- Selects the chip for an SPI data transaction. The pin must be pulled `low' for a 16-bit read or write function. See Figure 6 for timing specifications. FIFO Interrupt Output (active low) - When the internal FIFO is enabled (Configuration Register, Bit [6]), this pin acts as a FIFO Fill interrupt indicating that the FIFO has filled to its pre-programmed limit (FIFO Configuration Register, Bit [7..4]). SPI Serial Data Out - May be used to read out the Status Register contents. Interrupt Request Output - Any of the following events will generate an external interrupt: -Wake-up timer timeout -Low Battery Detect -FIFO fill -FIFO overflow To determine the source of the interrupt, the processor may read the first four bits of the Status Register. Data Output - Received data can be taken from this pin when the FIFO is not used. FIFO Select Input - When the FIFO is used this pin selects the FIFO when data is to be read out over the SDO pin. Data Recovery Clock Output - Recovered Data clock Output (FIFO not used). Filter Capacitor - When the analog filter is used this pin is the connection for the RC lowpass filter. The corner frequency should be set as close to the data rate as possible to retain good sensitivity. FIFO Interrupt Output (active high) - Indicates when there are remaining bits in the FIFO to be read. Set the FIFO Fill level to 1 in the FIFO Configuration Register. Optional host processor Clock Output. Frequency programmable through the Battery Detect Threshold and Clock Output Register. Xtal - Connects to a 10MHz series crystal or an external oscillator reference. The circuit contains an integrated load capacitor (See Configuration Register) in order to minimize the external component count. The crystal is used as the reference for the PLL, which generates the local oscillator frequency. The accuracy requirements for production tolerance, temperature drift and aging can be determined from the maximum allowable local oscillator frequency error. Whenever a low frequency error is essential for the application, it is possible to "pull" the crystal to the accurate frequency by changing the load capacitor value. Ext Ref - An external reference, such as an oscillator, may be connected as a reference source. Connect through a .01uF capacitor. Reset Output (active Low) System Ground RF Diff I/O RF Diff I/O Supply Voltage Analog RSSI Output - This pin may be used as an input to an A/D for signal strength or may be used as a baseband data output for OOK signaling. See Baseband Filter Register to calculate the appropriate filter capacitor value. Valid Data Detector Output - (See Receiver Control Register for output definition) 1.1 Processor Mode Pin Configuration TOP VIEW SDI SCK nCS SDO/FINT IRQ DATA/nFSEL CR/FINT/FCAP CLKOUT www.RFM.com Email: info@rfm.com (c)by RF Monolithics, Inc. 1 2 16 3 14 4 5 15 RXC101 13 12 6 11 7 8 10 9 DDET RSSIA VDD RF_N RF_P GND nRESET Xtal/Ref Page 4 of 43 RXC101 - 4/8/08 Simple Mode Pin 1 2 3 4 5 6 7 Name FS0 BS0 BS1 DO1 DO2 DO3 DO4 8 Mode/DCM 9 Xtal/Ref 10 11 12 13 14 15 16 FS1 GND RF_P RF_N VDD FS2 FS3 Description Frequency Select Bit 0 Band Select Bit 0 Band Select Bit 1 Digital Output 1 - May be connected to an LED or other device. Digital Output 2 - May be connected to an LED or other device. Digital Output 3 - May be connected to an LED or other device. Digital Output 4 - May be connected to an LED or other device. Mode Select - Sets the device in Processor or Simple Mode. When the chip powers on it checks the state of this pin and determines what mode to select. When this pin is connected to VDD or GND, the chip enters Simple Mode. Leaving this pin unconnected powers up the chip in Microprocessor Mode. (Low Power) Duty Cycle Mode - After power-up pulling this pin high puts the chip into the predefined duty cycle mode (see page 10 for description). Xtal - Connects to a 10MHz series crystal or an external oscillator reference. Ext Ref - An external reference, such as an oscillator, may be connected as a reference source. Connect through a .01uF capacitor. Frequency Select Bit 1 System Ground RF Signal Input RF Signal Input Supply Voltage Frequency Select Bit 2 Frequency Select Bit 3 1.2 Simple Mode Pin Configuration TOP VIEW FS0 BS0 BS1 DO1 DO2 DO3 DO4 Mode/DCM www.RFM.com Email: info@rfm.com (c)by RF Monolithics, Inc. 1 16 2 15 3 14 4 5 RXC101 13 12 6 11 7 8 10 9 FS3 FS2 VDD RF_N RF_P GND FS1 Xtal/Ref Page 5 of 43 RXC101 - 4/8/08 2. Functional Description The RXC101 is a low power, frequency agile, zero-IF, multi-channel FSK receiver for use in the 315, 433, 868, and 916 MHz bands. All RF and baseband functions are completely integrated requiring only a single 10MHz crystal as a reference source and an external low-cost processor. Functions include: * PLL synthesizer * LNA, programmable gain * I/Q Mixers * I/Q Demodulators * Baseband Filters * Baseband Amplifiers * RSSI * Low Battery Detector * Wake-up Timer/Duty Cycle Mode * Valid Data Detection/Data Quality The RXC101 is ideal for Frequency Hopping Spread Spectrum (FHSS) applications requiring frequency agility to meet FCC requirements. The RXC101 supports use of a low-cost microcontroller, or may operate as a single chip solution for simple applications. The RXC101 also incorporates different sleep modes to reduce overall current consumption and extend battery life. It is ideal for applications operating from typical lithium coin cells. 2.1 RXC101 Typical Application Circuit Figure 1. Typical Processor Mode Application Circuit Processor Mode (Application Circuit) The RF pins are high impedance and differential. The optimum differential load for the RF port is 250 Ohms. Antennas ideally suited for this would be a Dipole, Folded Dipole, and Loop. A single ended 50 Ohm connection may also be used with the matching circuit given in Figure 1. Matching component values for each band are given in Table 16. www.RFM.com Email: info@rfm.com (c)by RF Monolithics, Inc. Page 6 of 43 RXC101 - 4/8/08 The matching component values for each band are given in Table 1. Table 1. Band L1 315 56 nH 433 36 nH 868 15 nH 916 15 nH C1=C2 9 pF 7 pF 3 pF 3 pF Antenna Design Considerations The RXC101 was designed to drive a differential output such as a Dipole antenna or a Loop. Most compact applications use the loop since it can be made small. The dipole is typically not an attractive option for compact designs based on the fact of its inherent size at resonance and distance needed away from a ground plane to be an efficient antenna. A monopole is possible with addition of a balun or using the matching circuit in Figure 1. PCB Layout Considerations PCB layout is the most critical. For optimal receive performance, the trace lengths at the RF pins must be kept as short as possible. Using small, surface mount components, like 0402, will yield the best performance as well as keep the RF port compact. Make all RF connections short and direct. A good rule of thumb to adhere to is for every 0.1" of trace length add 1nH of series inductance to the path. The crystal oscillator is also affected by additional trace length in that it adds parasitic capacitance to the overall load of the crystal. To minimize this effect place the crystal as close as possible to the chip and make all connections short and direct. This will minimize the effects of "frequency pulling" that stray capacitance may introduce and allow the internal load capacitance of the chip to be more effective in properly loading the crystal oscillator circuit. If using an external processor, the RXC101 provides an on-chip clock for that purpose. Even though this is an integrated function, long runs of the clock signal may radiate and cause interference, especially if there is no ground plane run directly under the trace. This can degrade receiver performance. Keep clock connections as short as possible and surround the clock trace with an adjacent ground plane pour where needed. This will help in reducing any radiation or crosstalk due to long runs of the clock signal. Good power supply bypassing is also essential. Large decoupling capacitors should be placed at the point where power is applied to the PCB. Smaller value decoupling capacitors should then be placed at each power point of the chip as well as bias nodes for the RF port. Poor bypassing lends itself to conducted interference which can cause noise and spurious signals to couple into the RF sections, significantly reducing performance. www.RFM.com Email: info@rfm.com (c)by RF Monolithics, Inc. Page 7 of 43 RXC101 - 4/8/08 Assembly View Top Side Bottom Side www.RFM.com Email: info@rfm.com (c)by RF Monolithics, Inc. Page 8 of 43 RXC101 - 4/8/08 Silkscreen www.RFM.com Email: info@rfm.com (c)by RF Monolithics, Inc. Page 9 of 43 RXC101 - 4/8/08 2.2 Simple Mode The RXC101 can be configured for Simple Mode which does not require the use of a processor. All values on for internal registers are the default values assumed during POR. Even though the device is in this mode, the SPI bus, pins 1, 2 and 3, are still available to change internal configurations yet remain in simple mode operation. Figure 2. Typical Simple Mode Application Circuit M o d e /DCM FSK L NA I/Q D E M OD 0 /9 0 + ASK FS0 FS3 C ON TR OL LOGIC RS S I RF _ P RF _ N V CO PL L D O1 D O2 D O3 D O4 OS C C K T /N B A T T DE T M UX R X T A L /RE F FS2 FS1 V DD GN D Figure 3. Simple Mode Functional Block Diagram Email: info@rfm.com www.RFM.com (c)by RF Monolithics, Inc. BS0 BS1 Page 10 of 43 RXC101 - 4/8/08 At power-up the chip samples the state of pin 8. If the pin is logic `1' on power-up then it enters simple mode. If pin 8 is left unconnected it enters processor mode. In simple mode, 6 pins select the band and frequency within that band of operation. A seventh pin is available to operate the chip in duty cycle mode. Table 2 shows the 6-pin setup configuration. 315MHz BS[1,0]=00 310.320 310.960 311.600 312.240 312.880 313.520 314.160 314.800 315.440 316.080 316.720 317.360 318.000 318.640 319.280 319.920 433MHz BS[1,0]=01 4330360 433.440 433.520 433.600 433.680 433.760 433.840 433.920 434.000 434.080 434.160 434.240 434.320 434.400 434.480 434.560 Table 2. 868MHz 916MHz BS[1,0]=10 BS[1,0]=11 *867.680 *900.960 *867.840 902.880 *868.000 904.800 868.160 906.720 868.320 908.640 868.480 910.560 868.640 912.480 868.800 914.400 868.960 916.320 869.120 918.240 869.280 920.160 869.440 922.080 869.600 924.000 869.760 925.920 869.920 927.840 *870.080 *929.760 Address FS3 FS2 FS1 FS0 D4h D2h B4h B2h D4h D2h B4h B2h D4h D2h B4h B2h D4h D2h B4h B2h 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 *Out of Band Frequencies NOTE: Setting FS0='1' will change the DRSSI threshold from -103dBm to -97dBm. For simple mode a predefined data sequence is defined in order to toggle the four outputs available. The sequence includes a 16-bit preamble, synch word, address, and control bytes. The following is the sequence flow: Preamble (AAh) Synch Word (2Dh) Address (D4h, etc..) Output Control Byte Output Control Byte 1's Complement Output Control Byte (Transmit Order) DO4 CB(1) DO4 CB(0) DO3 CB(1) DO3 CB(0) DO2 CB(1) DO2 CB(0) DO1 CB(1) DO1 CB(0) (Transmit Order) Email: info@rfm.com www.RFM.com (c)by RF Monolithics, Inc. Page 11 of 43 RXC101 - 4/8/08 The Control Byte function is defined as follows: Table 3. Output Function NOP Set to Logic `0' Toggle Set to logic `1' for 100ms CB(1) 0 0 1 1 CB(0) 0 1 0 1 The data section of the packet must be sent as indicated. The 1's complement of the data is internally verified against the actual incoming data to ensure it is receiving the correct data and not spurious transmission from noise or a nearby interferer. By sending the data twice, once before and once after the 1's complement, this confirms to the receiver that it is receiving valid data. It is possible to use the receiver in a "mixed mode". The SPI bus architecture allows access to the SPI bus in simple mode (pins 1, 2, 3) and thereby makes it possible to overwrite the simple mode default POR values of the control registers. In this way the operating parameters of the receiver can be altered retaining the functionality of the standalone mode when receiving the proper data sequence. Duty Cycle Mode After power-up, connecting pin 8 to VDD will enable duty cycle mode. In this mode the chip will wake up every 300ms to sample the signal strength of the incoming signal. If there is none detected then it goes back into sleep until the next 300ms window arrives. When operating in Duty Cycle Mode, the chip consumes less than 500uA of average current. From start to finish, when the wake-up timer expires and the chip comes out of sleep, it switches on the oscillator and waits 2ms for the oscillator to stabilize then it switches on the synthesizer. The receiver then monitors the incoming signal strength for 6ms. If it detects a signal within that 6ms the synthesizer remains on for 30ms and waits for the preamble and the rest of the packet. If it does not detect a strong enough signal within the 6ms, it goes back into sleep mode until the next wake-up time. If it detects a strong signal, but incorrect data, at the end of the 30ms it will re-enter sleep mode until the next wake-up time. It should be noted that when the receiver is checking for signal strength, the state of the FS0 pin will determine the threshold limit. See NOTE after Table 2. Figure 4 shows the timing for Duty Cycle Mode. Email: info@rfm.com www.RFM.com (c)by RF Monolithics, Inc. Page 12 of 43 RXC101 - 4/8/08 Figure 4. Duty Cycle Mode Wake-up Timing Email: info@rfm.com www.RFM.com (c)by RF Monolithics, Inc. Page 13 of 43 RXC101 - 4/8/08 3. RXC101 Functional Characteristics Figure 5. Functional Block Diagram Input Amplifier (LNA) The LNA has selectable gain (0dB, -6dB, -14dB, -20dB) which may be useful in an environment with strong interferers. The LNA has a 250Ohm differential input impedance (0dB, -14dB) which requires a matching circuit when connected to 50 Ohm devices. Registers common to the LNA are: * Receiver Control Register Baseband Data and Filtering The baseband receiver has several programmable options that optimize the data link for a wide range of applications. The programmable functions include: * Receive bandwidth * Receive data rate * Baseband Analog Filter * Baseband Digital Filter * Clock Recovery (CR) * Receive FIFO * Data Quality Detector The receive bandwidth is programmable from 67 kHz to 400 kHz to accommodate various FSK modulation deviations as well as fast data rates. If the data rate is known for a given transmitter, the best results are obtained with a bandwidth at least twice the data rate. The receive data rate is programmable from 337bps to 256kbps. An internal prescaler is used to give better resolution when setting up the receive data rate. The prescaler is optional and may be disabled through the Data Rate Setup Register. The type of baseband filtering is selectable between an Analog filter and a Digital filter. The analog filter is a simple RC lowpass filter. An external capacitor may be chosen depending on the actual data rate. The chip Email: info@rfm.com www.RFM.com (c)by RF Monolithics, Inc. Page 14 of 43 RXC101 - 4/8/08 has an integrated 10KOhm resistor in series that makes the RC lowpass network. With the analog filter selected, a maximum data rate of 256kbps can be achieved. The digital filter is used with a clock frequency of 29X data rate. In this mode a clock recovery (CR) circuit is used to provide a synchronized clock source to recover the data using an external processor. The CR has three modes of operation: fast, slow, and automatic, all configurable through the Baseband Filter Register. The CR circuit works by sampling the preamble on the incoming data. The preamble must contain a series of 1's and 0's in order for the CR circuit to properly extract the data timing. In slow mode the CR circuit requires more sampling (12 to 16 bits) and thus has a longer settling time before locking. In fast mode the CR circuit takes fewer samples (6 to 8 bits) before locking so settling time is not as long and timing accuracy is not critical. In automatic mode the CR circuit begins in fast mode to coarsely acquire the timing period with fewer samples then changes to slow mode after locking. Further details of the CR and data rate clock are provided in the Baseband Filter Register. CR is only used with the digital filter and data rate clock. These are not used when configured for the analog filter. The Data Quality Detector looks at the unfiltered incoming data and counts the "spikes" for a given period. The higher the "spike" count, the lower the data quality. The data quality threshold may be set, restricting when the chip may report "Good Signal Quality". Data Quality Detector (DQD) The DQD is a unique function of the TRC101. The DQD circuit looks at the prefiltered incoming and counts the "spikes" of noise for a predetermined period of time to get an idea of the quality of the link. This parameter is programmable through the Data Filter Command Register. The DQD count threshold is programmable from 0 to 7 counts. The higher the count the lower the quality of the data link. This means the higher the content of noise spikes in the data stream the more difficult it will be to recover clock information as well as data. Valid Data Detector (DDet) The VDI is an extension of the DQD. When incoming data is detected, it uses the DQD signal, the Clock Recovery Lock signal, and the Digital RSSI signal to determine if the incoming data is valid. The VDI signal is valid when using either the internal receive FIFO or an external pin to capture baseband data. The VDI has three modes of operation: slow, medium, fast. Each mode is dependent on what signals it uses to determine valid data as well as the number of incoming preamble bits present at the beginning of the packet. Receiver FIFO The receive FIFO is configured as one 16-bit register. The FIFO can be configured to generate an interrupt after a predefined number of bits have been received. This threshold is programmable from 1 to 16 bits (0..15). It is recommended to set the threshold to at least half the length of the register (8 bits) to insure the external host processor has time to set up before performing a FIFO read. The FIFO read clock (SCK) must be < fXTAL/4 or <2.5 MHz for a 10 MHz reference xtal. The receive FIFO may also be configured to fill only when valid data has been identified. The RXC101 has a synchronous pattern detector that watches incoming data for a particular pattern. When it sees this pattern it begins to store any data that follows. At the same time, if pin 16 is configured for Valid Data Indicator output (See Receiver Control Register), this pin will go `high' signaling valid data. This can be used to wake up or prepare a host processor for processing data. The internal synchronous pattern is set to 2DD4h and is not configurable. The receive packet structure when using the synchronous pattern should be: PREAMBLE 0xAA PREAMBLE 0xAA Email: info@rfm.com www.RFM.com (c)by RF Monolithics, Inc. SYNCH BYTE 0x2D SYNCH BYTE 0XD4 DATA [N] DATA [N+1] DATA [N+2 Page 15 of 43 RXC101 - 4/8/08 Any packet sent, whether using the synchronous pattern or not, should always start with a preamble sequence of alternating 1's and 0's, such as 1-0-1-0-1. This corresponds to sending a 0xAA or 0x55. The preamble may be one byte (Fast CR lock) or two bytes (Slow CR lock). The next two bytes should be the synchronous pattern. In this case, data storage begins immediately following the 2nd synch byte. All other following bytes are treated as data. The FIFO can be read out through the SDO pin only by pulling the nFSEL pin (6) `Low" which selects the FIFO for read and reading out data on the next SPI clock. The FINT pin (7) will stay active (logic `1') until the last bit has been read out, and it will then go `low'. This pin may also be polled to watch for valid data. When the number of bits received in the FIFO match the pre-programmed limit, this pin will go active (logic `1') and stay active until the last bit is read out as above. An alternative method of reading the FIFO is through an SPI bus Status Register read. The drawback to this is that all interrupt and status bits must be read first before the FIFO bits appear on the bus. This could pose a problem for receiving large amounts of data. The best method is using the SDO pin and the associated FIFO function pins. Receive Signal Strength Indicator (RSSI) The RXC101 provides an analog RSSI and a digital RSSI. The digital RSSI threshold is programmable through the Receiver Control Register and is readable through the Status Register only. When an incoming signal is stronger than the preprogrammed threshold, the digital RSSI bit in the Status Register is set. Input Power vs RSSI Voltage 1.2 1 RSSI (V) 0.8 0.6 Series1 0.4 0.2 0 -112 -102 -92 -82 -72 -62 -52 -42 Input Power (dBm) The analog RSSI is available through and external pin (15). This pin requires an external capacitor which sets the settling time. The analog RSSI may be used to recover OOK modulated data at a low rate on the order of 1-2Kbps. The external capacitor value will control the received OOK data rate allowed so choosing a lower value capacitor enables recovery of faster data at the expense of amplitude. Using pin (15) with a sensitive external comparator will yield better results. Automatic Frequency Adjustment (AFA) The PLL has the capability to do fine adjustment of the carrier frequency automatically. In this way, the receiver can minimize the offset between the transmit and receive frequency. This function may be enabled or disabled through the Automatic Frequency Adjustment Register. The range of offset can be programmed as well as the offset value calculated and added to the frequency control word within the PLL to incrementally change the carrier frequency. The chip can be programmed to automatically perform an adjustment or may be manually activated by a strobe signal. This function has the advantage of allowing: * Low cost, lower accuracy crystals to be used * Increased receiver sensitivity by narrowing the receive bandwidth * Achieving higher data rates Crystal Oscillator Email: info@rfm.com www.RFM.com (c)by RF Monolithics, Inc. Page 16 of 43 RXC101 - 4/8/08 The RXC101 incorporates an internal crystal oscillator circuit that provides a 10MHz reference, as well as internal load capacitors. This significantly reduces the component count required. The internal load capacitance is programmable from 8.5pF to 16pF in 0.5pF steps. This has the advantage of accepting a wide range of crystals from many different manufacturers having different load capacitance requirements. Being able to vary the load capacitance also helps with fine tuning the final carrier frequency since the crystal is the PLL reference for the carrier. When the shunt capacitance, Co, is worst case 7pF and the ESR is 300 Ohms max, the oscillator can be expected to meet the start-up times as defined in the AC Characteristics. Crystals with less than 7pF shunt capacitance and lower ESR guarantee much faster start-up times. An external clock signal is also provided that may be used to run an external processor. This also has the advantage of reducing component count by eliminating an additional crystal for the host processor. The clock frequency is also programmable from eight pre-defined frequencies, each a pre-scaled value of the 10MHz crystal reference. These values are programmable through the Battery Detect Threshold and Clock Output Register. The internal clock oscillator may be disabled which also disables the output clock signal to the host processor. When the oscillator is disabled, the chip provides an additional 196 clock cycles before releasing the output, which may be used by the host processor to setup any functions before going to sleep. When putting the device into sleep mode, the clock output must be disabled. If the clock out is not disabled then the crystal oscillator will continue to run causing excessive current consumption. Frequency Control (PLL) and Frequency Synthesizer The PLL synthesizer is the heart of the operating frequency. It is programmable and completely integrated, providing all functions required to generate the carriers and tunability for each band. The PLL requires only a single 10MHz crystal reference source. RF stability is controlled by choosing a crystal with the particular specifications to satisfy the application. This gives maximum flexibility in performance. The PLL is able to perform manual and automatic calibration to compensate for changes in temperature or operating voltage. When changing band frequencies, re-calibration must be performed. This can be done by disabling the synthesizer and re-enabling again through the Configuration Register. Registers common to the PLL are: * Configuration Register * Frequency Setting Register * Automatic Frequency Adjust Register Wake-Up Mode The RXC101 has an internal wake-up timer that has very low current consumption (1.5uA typical) and may be programmed from 1msec to several days. A calibration is performed to the crystal at startup and every 30 sec thereafter, even if in sleep mode. If the oscillator circuit is disabled the calibration circuit will turn it on briefly to perform a calibration to maintain accurate timing and return to sleep. The RXC101 also incorporates other power saving modes aside from the wake-up timer. Return to active mode may be initiated from several external events: * Logic `0' applied to nINT pin (16) * Low Supply Voltage Detect * FIFO Fill * SPI request If any of these wake-up events occur, including the wake-up timer, the RXC101 generates an external interrupt which may be used as a wake-up signal to a host processor. The source of the interrupt may be read out from the Status Register over the SPI bus. Duty Cycle Mode The duty cycle register may be used in conjunction with the wake-up timer to reduce the average current consumption of the receiver. The duty cycle register may be set up so that when the wake-up timer brings the chip out of sleep mode the receiver is turned on for a short time to sample if a signal is present and then goes back into sleep and the process starts over. See the Duty Cycle Set Register. The receiver must be disabled (RXEN bit 0 cleared in Receiver Control Register) and the wake-up timer must be enabled (WKUPEN bit 9 set in Configuration Register) for operation in this mode. Figure 6 shows the timing for Duty Cycle Mode. Email: info@rfm.com www.RFM.com (c)by RF Monolithics, Inc. Page 17 of 43 RXC101 - 4/8/08 Figure 6. Duty Cycle Mode Timing Email: info@rfm.com www.RFM.com (c)by RF Monolithics, Inc. Page 18 of 43 RXC101 - 4/8/08 Low Battery Detect The integrated low battery detector monitors the voltage supply against a preprogrammed value and generates an interrupt when the supply voltage falls below the programmed value. The detector circuit has 50mV of hysteresis built in. OOK Operation The RXC101 may operate in a limited OOK function. The RSSI is internally connected to a comparator and the output data is then applied to pin 6. The limitations for this mode are due to the fact that the RSSI signal is not internally capacitively coupled to the comparator, which limits the dynamic range of the received signal, and the DRSSI threshold sets the reference point for the internal comparator. The best approach for optimal received signal dynamic range would be to implement an external comparator circuit and capacitively couple the RSSI signal from pin 15 to the external comparator. This would eliminate the need to adjust the DRSSI threshold and allow for a much smaller signal amplitude to be recovered. The input LNA gain would still need to be adjusted depending on the strength of the signal in order to optimize the dynamic range. Upon power-up or signal reception, the RSSI may be sampled by an A/D for DC level to determine if the RSSI is in saturation and decide whether to increase or decrease LNA gain for best signal recovery. SPI Interface The RXC101 is equipped with a standard SPI bus that is compatible to most any SPI device. All functions and status of the chip are accessible through the SPI bus. Typical SPI devices are configured for byte write operations. The TRC101 uses word writes so the nCS pin should be pulled low for 16 bits. The maximum clock for the SPI bus is 20 MHz. Email: info@rfm.com www.RFM.com (c)by RF Monolithics, Inc. Page 19 of 43 RXC101 - 4/8/08 nCS Figure 7. SPI Interface Timing Email: info@rfm.com www.RFM.com (c)by RF Monolithics, Inc. Page 20 of 43 RXC101 - 4/8/08 4. Control and Configuration Registers STATUS Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 LB FIFEMP RSSI GDQD OFF3 OFF2 OFF1 OFF0 FIFOIT FIFOV WKINT CRLCK AFATGL CONFIG 1 0 0 AFA 1 1 0 0 0 1 1 0 FREQ SET 1 0 1 0 Freq11 Freq10 Freq9 Freq8 Freq7 RECV CTRL 1 1 0 0 0 0 0 0 BASEBAND 1 1 0 0 0 1 0 FIFO CONFIG 1 1 0 0 1 1 1 1 0 0 1 1 1 1 R4 1 1 0 1 1 0 DATA RATE SET WAKE-UP PERIOD DUTY CYCLE SET BATT DETECT BAND1 BAND0 LBDEN WKUPEN OSCEN CAP2 OFFSGN OFF4 -- CAP1 CAP0 BB2 BB1 BB0 CLKEN 893Ah RNG1 RNG0 STRB ACCF OFFEN AFEN C6F7h Freq6 Freq5 Freq4 Freq3 Freq2 Freq1 Freq0 A680h VDI1 VDI0 GAIN1 GAIN0 RSSI2 RSSI1 RSSI0 RXEN C0C1h 0 CRLK CRLC 1 1 0 FINT3 FINT2 FINT1 FINT0 FIFST1 FIFST0 FILLEN FIFEN CE89h 0 0 0 PRE BITR6 BITR5 BITR4 BITR3 BITR2 BITR1 BITR0 C823h R3 R2 R1 R0 MUL7 MUL6 MUL5 MUL4 MUL3 MUL2 MUL1 MUL0 E196h 0 1 1 0 0 DC6 DC5 DC4 DC3 DC2 DC1 DC0 DCEN CC0Eh 0 0 0 1 0 CLK2 CLK1 CLK0 LBD4 LBD3 LBD2 LBD1 LBD0 C200h Email: info@rfm.com www.RFM.com (c)by RF Monolithics, Inc. CAP3 AFA POR Value AUTO1 AUTO0 FILT 1 DQLVL2 DQLVL1 DQLVL0 Page 21 of 43 RXC101 - 4/8/08 C42Ch Status Register (Read Only) Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 FIFOIT FIFOV WKINT LB FIFEMP RSSI GDQD CRLCK AFATGL AFA OFFSGN OFF4 OFF3 OFF2 OFF1 OFF0 The Status Register provides feedback for: * FIFO overwrite * FIFO fill interrupt * Low Battery * Data Quality * Digital RSSI signal level * Clock Recovery * Frequency Offset value and sign * AFA Note: The Status Register read command begins with a logic `0' where all other register commands begin with a logic `1'. Bit [15]:FIFOIT - When set, indicates that the number of data bits received by the FIFO has reached it programmed limit. See FIFO Fill Bit Count Bits[7..4] of the FIFO Configuration Register. Bit [14]:FIFOV - When set, indicates receive FIFO overflow. (Cleared after Status Reg read). Bit [13]:WKINT - When set, indicates a Wake-up timer overflow. (Cleared after Status Reg read). Bit [12]:LB - When set, indicates the supply voltage is below the preprogrammed limit. See Battery Detect Threshold and Clock Output Register. Bit [11]:FIFEMP - When set, indicates receive FIFO is empty. Bit [10]:RSSI - When set, this bit indicates that the incoming RF signal is above the preprogrammed Digital RSSI limit. Bit [9]:GDQD - When set, indicates good data quality. Bit [8]:CRLCK - When set, indicates Clock Recovery is locked. Bit [7]:AFATGL - For each AFA cycle run, this bit will toggle between logic `1' and logic `0'. Bit [6]:AFA - When set, indicates that the frequency adjust has detected the same offset value for two consecutive measurements and thus the frequency is stabilized. Bit [5]:OFFSGN - Indicates the difference in frequency is higher (logic `1') or lower (logic `0') than the chip frequency. Bit [4..0]:OFF[4..0] - The offset value to be added to the frequency control word (internal PLL). In order to get accurate values the AFA has to be disabled during the read by clearing the "AFEN" bit in the AFA Register (bit 0). Email: info@rfm.com www.RFM.com (c)by RF Monolithics, Inc. Page 22 of 43 RXC101 - 4/8/08 Configuration Register [POR=893Ah] Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 1 0 0 BAND1 BAND0 LBDEN WKUPEN OSCEN CAP3 CAP2 CAP1 CAP0 BB2 BB1 BB0 CLKEN The configuration register sets up the following: * Internal Data Register * Internal FIFO * Frequency Band in use * Crystal Load capacitance Bit [15..13] - Command Code: These bits are the command code that is sent serially to the processor that identifies the bits to be written to the Configuration Register. Bit [12..11] - Band Select: These bits set the frequency band to be used. There are four (4) bands that are supported. See Table 4 for Band configuration. TABLE 4. Frequency Band BAND1 315 0 433 0 868 1 916 1 BAND0 0 1 0 1 Bit [10] - Low Battery Detector: This bit enables the battery voltage detect circuit when set. The battery detector can be programmed to 32 different threshold levels. See Battery Detect Threshold and Clock Output Register section for programming. Bit [9] - Wake-up Timer Enable: This bit enables the wake-up timer when set. See Wake-up Timer Period Register section for programming the wake-up timer interval value. Bit [8] - Crystal Oscillator: This bit enables the oscillator circuit when set. The oscillator provides the reference signal for the synthesizer when setting the receive frequency of use. Bit [7..4] - Load Capacitance Select: These bits set the load capacitance for the crystal reference. The internal load capacitance can be varied from 8.5pF to 16pF in .5pF steps to accommodate a wide range of crystal vendors as well as adjust the reference frequency and compensate for stray capacitance that may be introduced due to PCB layout. See Table 5 for load capacitance configuration. TABLE 5. CAP3 0 0 0 0 0 0 0 0 1 1 1 1 CAP2 0 0 0 0 1 1 1 1 0 0 0 0 Email: info@rfm.com www.RFM.com (c)by RF Monolithics, Inc. CAP1 0 0 1 1 0 0 1 1 0 0 1 1 CAP0 0 1 0 1 0 1 0 1 0 1 0 1 Crystal Load Capacitance 8.5 9 9.5 10 10.5 11 11.5 12 12.5 13 13.5 14 Page 23 of 43 RXC101 - 4/8/08 1 1 1 1 1 1 1 1 0 0 1 1 0 1 0 1 14.5 15 15.5 16 Configuration Register (continued) Bit [3..1] - Receiver Baseband Bandwidth: These bits set the baseband bandwidth of the demodulated data. The bandwidth can accommodate different FSK deviations and data rates. See Table 6 for bandwidth configuration. Table 6. Baseband BW (kHz) Resvd 400 340 270 200 134 67 Resvd BB2 0 0 0 0 1 1 1 1 BB1 0 0 1 1 0 0 1 1 BB0 0 1 0 1 0 1 0 1 Bit [0] - Clock Output Disable: This bit disables the oscillator clock output when set. On chip reset or power up, clock output is on so that a processor may begin execution of any special setup sequences as required by the designer. See Battery Detect Threshold and Clock Output Register section for programming details. Email: info@rfm.com www.RFM.com (c)by RF Monolithics, Inc. Page 24 of 43 RXC101 - 4/8/08 Receiver Control Register [POR=C0C1h] Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 1 1 0 0 0 0 0 0 VDI1 VDI0 GAIN1 GAIN0 RSSI2 RSSI1 RSSI0 RXEN The Receiver Control Register configures the following: * Receiver LNA gain * Digital RSSI threshold * Receive baseband bandwidth * Valid Data Indicator response time * Function of pin 16 Bit [15..8] - Command Code: These bits are the command code that is sent serially to the processor that identifies the bits to be written to the Receiver Control Register. Bit [7..6] - Pin 16 Func: Selects the function of Pin 16. See Table 7 below. Table 7. Pin 16 Function Digital RSSI Out DQD Out Clock Recovery Lock Valid Data Output VDI1 0 0 1 1 VDI0 0 1 0 1 Bit [5..4] - Receiver LNA Gain: These bits set the receiver LNA gain, which can be changed to accommodate environments with high interferers. The LNA gain also affects the true RSSI value. Refer to Bit [2..0] for RSSI. See Table 8 below for gain configuration. Table 8. LNA GAIN (dB) 0 -6 -14 -20 GAIN1 0 0 1 1 GAIN0 0 1 0 1 Bit [3..1] - Digital RSSI Threshold: The digital receive signal strength indicator threshold may be set to indicate that the incoming signal strength is above a preset limit. The result is stored in bit 7 of the status register. There are eight (8) predefined thresholds that can be set. See Table 9 below for settings. RSSI Thresh -103 -97 -91 -85 -79 -73 Resvd Resvd Email: info@rfm.com www.RFM.com (c)by RF Monolithics, Inc. Table 9. RSSI2 RSSI1 0 0 0 0 0 1 0 1 1 0 1 0 1 1 1 1 RSSI0 0 1 0 1 0 1 0 1 Page 25 of 43 RXC101 - 4/8/08 Receiver Control Register (continued) The RSSI threshold is affected by the LNA gain set value. Calculate the true RSSI set threshold when the LNA gain is set to a value other than 0 dB as: RSSI = RSSIthres + |GainLNA| Bit [0] - Receiver Chain Enable: This bit enables the entire receiver chain when set. The receiver chain comprises the baseband circuit, synthesizer, and crystal oscillator. When using this bit to control the receive chain, the clock pulses produced when the crystal oscillator is shut down is disabled. When this bit is cleared, the clock output signal stops abruptly. Email: info@rfm.com www.RFM.com (c)by RF Monolithics, Inc. Page 26 of 43 RXC101 - 4/8/08 FIFO Configuration Register [POR=CE89h] Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 1 1 0 0 1 1 1 0 FINT3 FINT2 FINT1 FINT0 FIFST1 FIFST0 FILLEN FIFEN The Data FIFO Configuration Register configures: * FIFO fill interrupt condition * FIFO fill start condition * FIFO fill on synchronous pattern * FIFO Enable Bit [15..8] - Command Code: These bits are the command code that is sent serially to the processor that identifies the bits to be written to the Data FIFO Configuration Register. Bit [7..4] - FIFO Fill Bit Count: This sets the number of bits that are received before generating an external interrupt to the host processor that the receive FIFO data is ready to be read out. It is possible to set the maximum fill level to 15 (16-bits), but the designer must account for the processing time it will take to read out the data before a register overrun occurs, at which data will be lost. It is recommended to set the fill value to half of the desired number of bits to be read to ensure enough time for additional processing. See Status Register for description of FIFO status bits that may be read and FIFO Read Register for polling and interrupt-driven FIFO reads from the SPI bus. Bit [3..2] - FIFO Fill Start Condition: These bits set the condition at which the FIFO begins filling with data. Table 10 describes the start conditions. See Valid Data configuration in Receiver Control Register. Table 10. Fill Start Condition FIFST1 FIFST0 Valid Data 0 0 Synch Word 0 1 Valid Data and Sync Word 1 0 Continuous Fill 1 1 Bit [1] - Synchronous Pattern FIFO Fill Enable: When set, the FIFO will begin filling with data when it detects the FIFO Fill Start Condition as defined in bits[3..2] above. The FIFO fill stops and the FIFO is reset when this bit is cleared. To restart simply clear the bit and set again. Bit [0] - FIFO Enable: This bit enables the internal data FIFO when set. If the data FIFO is enabled, the DATA/nFSEL pin (6) must be pulled "Low". The FIFO is used to store data during receive. If the FIFO is enabled by setting this bit, pin 6 becomes nFSEL and pin 7 becomes FINT. *Recommended FIFO Read Method The Rx FIFO is directly accessible by using the nFSEL select pin (6) and monitoring the FINT interrupt pin (7) for pending data. Each data bit may be clocked in on the rising edge of SCK. See Figure 8 for timing reference. Figure 8. Recommended FIFO Read Method Timing Email: info@rfm.com www.RFM.com (c)by RF Monolithics, Inc. Page 27 of 43 RXC101 - 4/8/08 *NOTE: The internal FIFO cannot be accessed faster than fXTAL/4 when reading the FIFO or data errors will occur. For a 10MHz ref xtal the max SCK <2.5MHz. Email: info@rfm.com www.RFM.com (c)by RF Monolithics, Inc. Page 28 of 43 RXC101 - 4/8/08 Automatic Frequency Adjust Register [POR=C6F7h] Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 1 1 0 0 0 1 1 0 AUTO1 AUTO0 RNG1 RNG0 STRB ACCF OFFEN AFEN The AFA (Automatic Frequency Adjust) Register configures: * Manual or Automatic frequency offset adjustment * Calculation of the offset value and write to the Status Register * Fine offset adjustment control The AFA (Automatic Frequency Adjust) Register controls and configures the frequency adjustment range and mode for keeping the receiver frequency locked, providing for an optimal link. The AFA may be manually controlled by an external processor by asserting a strobe signal to initiate a sample, or may be setup for automatic operation. The AFA also calculates the offset of the transmit and receive frequency. This offset value is included in the status register read and the AFA must be disabled during the status read to ensure reporting good offset accuracy. Bit [15..8] - Command Code: These bits are the command code that is sent serially to the processor that identifies the bits to be written to the Automatic Frequency Adjust Register. Bit [7..6] - Mode Selection: These bits select Automatic or manual operation. When set to Manual operation, the RXC101 will take a sample when a strobe signal (See Bit [3]) is written to the register. There are four modes of operation. See Table 11 below for configuration. TABLE 11. Automatic fOFFSET Mode Mode Off Run Once after Pwr-up Keep offset during Rcv ONLY Keep offset indep of VDI state AUTO1 0 0 1 1 AUTO0 0 1 0 1 Mode Operation Mode(0,1) - The circuit takes a measurement only once after power-up. This maximizes the distance that can be achieved for a single link. Mode(1,0) - When the Valid Data Indicator (VDI) pin is low, indicating poor receiving conditions, the offset register is automatically cleared. Use this setting when receiving from several different transmitters that are operating very close to the same frequencies. Mode(1,1) - This setting is best used when receiving from a single transmitter. The measured offset value is kept independent of the state of the VDI signal. Bit [5..4] - Allowable Frequency Offset: These bits select the amount of offset allowable between Transmitter and Receiver frequencies. The allowable range can be specified as in Table 12 below. TABLE 12. Freq Offset Range RNG1 RNG0 No Limit 0 0 +15*fres/-16*fres 0 1 +7*fres /-8*fres 1 0 +3*fres /-4*fres 1 1 where fres is the tuning resolution for each band as follows: Email: info@rfm.com www.RFM.com (c)by RF Monolithics, Inc. Page 29 of 43 RXC101 - 4/8/08 fres: 315 MHz Band = 2.5kHz 433 MHz Band = 2.5kHz 868 MHz Band = 5kHz 916 MHz Band = 7.5kHz Automatic Frequency Adjust Register (continued) Bit [3] - Manual Frequency Adjustment Strobe: This bit is the strobe signal that initiates a manual frequency adjustment sample. When set, a sample of the received signal is compared to the Receiver LO signal and an offset is calculated. If enabled, this value is written to the Offset Register (See Bit [1]) and added to the frequency control word of the PLL. This bit MUST be reset before initiating another sample. Bit [2] - High Accuracy (Fine) Mode: This bit, when set, switches the frequency adjustment mode to high accuracy. In this mode the processing time is twice the regular mode, but the uncertainty of the measurement is significantly reduced. Bit [1] - Frequency Offset Register Enable: This bit, when set, enables the offset value calculated by the offset sample to be added to the frequency control word of the PLL that tunes the desired carrier frequency. Bit [0] - Offset Frequency Enable: This bit, when set, enables the RXC101 to calculate the offset frequency by the sample taken from the Automatic Frequency Adjustment circuit. Email: info@rfm.com www.RFM.com (c)by RF Monolithics, Inc. Page 30 of 43 RXC101 - 4/8/08 Baseband Filter Register [POR=C42Ch] Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 1 1 0 0 0 1 0 0 CRLK CRLC 1 FILT1 FILT0 DQLVL2 DQLVL1 DQLVL0 The Baseband Filter Register configures: * Clock Recovery lock control * Baseband Filter type, Digital or Analog RC * Data Quality Detect Threshold parameter Bit [15..8] - Command Code: These bits are the command code that is sent serially to the processor that identifies the bits to be written to the Baseband Filter Register. Bit [7] - Automatic Clock Recovery Lock: When set, this bit configures the CR (clock recovery) lock control to automatic. In this setting the clock recovery will startup in "Fast" mode and automatically switch to "Slow" mode after locking. See Bit [6] description for details of "Fast" and "Slow" modes. Bit [6] - Manual Clock Recovery Lock Control: When set, this bit configures the CR lock to "Fast" mode. "Fast" mode requires a preamble of at least 6 to 8 bits to determine the clock rate, then locks. When cleared, this bit configures the CR lock to "Slow" mode. "Slow" mode takes a little longer in that it requires a preamble of at least 12 to 16 bits to determine the clock rate, then locks. Use of the "Slow" mode requires more accurate bit timing. See Data Rate Setup Register for the relationship of data rate and CR. Bit [5] - Not Used. Write a "1". Bit [4..3] - Filter Type: Table 13. Filter FILT1 RSSI for OOK 0 Digital 0 1 Not Used Analog RC 1 FILT0 0 1 0 1 RSSI for OOK: The Analog RSSI Output signal is used to receive the incoming data. The Digital RSSI is used for data slicing. Set DRSSI parameter in the Receiver Control Register. Digital Filter: The Digital filter is a digital version of a simple RC lowpass filter followed by a comparator with hysteresis. The time constant for the Digital filter is automatically calculated internally based on the bit rate as set in the Data Rate Setup Register. Analog RC lowpass filter: The baseband signal is fed to pin 7 thru an internal 10K Ohm resistor. The lowpass cutoff frequency is set by the external capacitor connected from pin 7 to GND. To calculate the baseband capacitor value for a given data rate, use: CFILT = 1 / (30,000*Data Rate) Bit [2..0] - Data Quality Detect Threshold: The threshold parameter should be set less than four (<4) in order for the Data Quality Detector to report good signal quality in the case that the bit rate is close to the deviation. As the data rate << deviation, a higher threshold parameter is permitted and may report good signal quality. Email: info@rfm.com www.RFM.com (c)by RF Monolithics, Inc. Page 31 of 43 RXC101 - 4/8/08 Frequency Setting Register [POR=A680h] Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 1 0 1 0 Freq11 Freq10 Freq9 Freq8 Freq7 Freq6 Freq5 Freq4 Freq3 Freq2 Freq1 Freq0 The Frequency Setting Register sets the exact frequency within the selected band for receive. Each band has a range of frequencies available for channelization or frequency hopping. The selectable frequencies for each band are: Frequency Band 300 MHz 400 MHz 800 MHz 900 MHz Min (MHz) 310.24 430.24 860.48 900.72 Max (MHz) 319.75 439.75 879.51 929.27 Tuning Resolution 2.5 kHz 2.5 kHz 5.0 kHz 7.5 kHz Bit descriptions are as follows: Bit [15..12] - Command Code: These bits are the command code that is sent serially to the processor that identifies the bits to be written to the Frequency Setting register. Bit [11..0] - Frequency Setting: These bits set the center frequency to be used during receive. The value of bits[11..0] must be in the decimal range of 96 to 3903. Any value outside of this range will cause the previous value to be kept and no frequency change will occur. To calculate the center frequency fc, use Table 3 below and the following equation: fc = 10 * B1 * (B0 + fVAL/4000) MHz where fVAL = decimal value of Freq[11..0] = 96