Murata
Manufacturing Co., Ltd.
Cat.No.C09E-6
EMI Suppression Filters (EMIFILr) for AC Power Lines
EMI
SUPPRESSION
FILTERS (EMIFILr)
Murata EMC Solutions : http://www.murata.co.jp/emc/
Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this PDF catalog to prevent smoking and/or burning, etc.
This catalog has only typical specifications. Therefore, you are requested to approve our product specifications or to transact the approval sheet for product specificaions before ordering.
!Note C09E6.pdf 03.3.10
CONTENTS
!Note • Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this catalog to prevent smoking and/or burning, etc.
• This catalog has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering.
Recycled Paper
Part Numbering 2
Outline of EMI Suppression Filter (EMIFILr) for AC Power Lines 3
Common Mode Choke Coil 5
PLA10 Series Standard Winding Type 5
PLA10 Series Sectional Winding Type 6
PLA10 Series (Safety Standard Recognized) Standard Winding Type 7
PLA10 Series (Safety Standard Recognized) Sectional Winding Type 7
PLH10 Series 9
PLH10 Series (Safety Standard Recognized) 10
Hybrid Choke Coil 11
PLY10 Series Standard Winding Type 11
PLY10 Series Sectional Winding Type 11
Noise Suppression Effect of PLY10 Series 13
!Caution /Notice 14
Packaging 16
EMIFILr in this catalog is the trademark of Murata Manufacturing Co., Ltd.
1
2
1
2
Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this PDF catalog to prevent smoking and/or burning, etc.
This catalog has only typical specifications. Therefore, you are requested to approve our product specifications or to transact the approval sheet for product specificaions before ordering.
!Note C09E6.pdf 03.3.10
!Note • Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this catalog to prevent smoking and/or burning, etc.
• This catalog has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering.
2
(Global Part Number)
AC Line Filters
eApplications
Code
for AC Line
Applications
10
Code
Core Vertical Type
Structure
A
qProduct ID
PL Common Mode Choke Coils
Product ID
wType
A
H
Y
AC Standard Type
AC High-frequency Type
AC Hybrid Choke Coils Type
Code Type
!0Packaging
B
MAll series
Bulk
Magazine Package
Code Packaging Series
iWinding Mode
D
R
P
Sectional Winding Type
Standard Type
Aligned Winding Type
Code Winding Mode
uRated Current
Expressed by three figures. The unit is in amperes (A). A decimal
point is expressed by the capital letter "R". In this case, all figures
are significant digits.
oLead Dimensions
23.5mm
Code Lead Dimensions
rStructure
Code
Safety Recognized
General Use
Features
S
N
tFeatures
yInductance
Expressed by three figures. The unit is micro-henry (µH). The first
and second figures are significant digits, and the third figure
expresses the number of zeros which follow the two figures. If
there is a decimal point, it is expressed by the capital letter "R". In
this case, all figures are significant digits. If inductance is less
than 0.1 µH, the inductance code is expressed by a combination
of two figures and capital letter "N", and the unit of inductance is
nano-henry (nH). The capital letter "N" indicates the unit of "nH",
and also expresses a decimal point. In this case, all figures are
significant digits.
y
152
t
S
u
2R0
q
PL
r
A
e
10
w
A
i
R
o
2
!0
B
o Part Numbering The structure of the "Global Part Numbers" that have been adopted since June 2001 and the meaning of each code are described herein.
If you have any questions about details, please inquire at your usual Murata sales office or distributor.
()
Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this PDF catalog to prevent smoking and/or burning, etc.
This catalog has only typical specifications. Therefore, you are requested to approve our product specifications or to transact the approval sheet for product specificaions before ordering.
!Note C09E6.pdf 03.3.10
!Note • Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this catalog to prevent smoking and/or burning, etc.
• This catalog has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering.
3
EMI (Electro Magnetic Interference) suppression filter for AC
power lines eliminate noise entering equipment from
commercial power lines or noise generated from electronic
equipment.
Common mode chokes, line bypass capacitors, across the
line capacitors are generally used as AC EMI suppression
filter device. In suppressing common mode noise, common
mode chokes are most important devices. Because the
characteristics of common mode chokes influences
performance of total filter block MURATA provides two types
of common mode chokes. (Standard type, High-frequency
type)
Hybrid choke coil is high performance EMI suppression
device which can suppress both common mode noise and
differential mode noise at the same time. It is effective in AC
power supplies with active device for higher harmonic
countermeasure, which tend to emit relatively higher
differential mode noise.
Classification of EMI Suppression Filter for AC Power Lines
Product Name
Common Mode Choke Coil Standard Type
Suppression of general
common mode noise
Suppression of common mode
noise contains high-frequency
noise above 10MHz
Suppression of conduction
noise in AC power line with
active device for higher
harmonic countermeasure.
Suppression of AC power line
noise which contains both
common mode noise and
differential mode noise.
PLA10
PLH10
PLY10
High Frequency Type
Hybrid Choke Coil
Appearance Effective Frequency Range (Hz)
10k 100k 1M 10M 100M 1G Application
Outline of EMI Suppression Filter (EMIFILr) for AC Power Lines
Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this PDF catalog to prevent smoking and/or burning, etc.
This catalog has only typical specifications. Therefore, you are requested to approve our product specifications or to transact the approval sheet for product specificaions before ordering.
!Note C09E6.pdf 03.3.10
!Note Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this catalog to prevent smoking and/or burning, etc.
This catalog has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering.
4
Outline of EMI Suppression Filter (EMIFILr) for AC Power Lines
Common Mode Choke Coil Standard Winding and Sectional Winding
Noise Measures for Switching Power Supply
Standard Winding
Sectional Winding
1
18
19
36
2
17
20
35
3
16
21
34
4
15
22
33
5
14
23
32
6
13
24
31
7
12
25
30
8
11
26
29
9
10
27
28
End of Winding
End of Winding
Beginning of Winding
High-frequency noise can pass through the
Filter easily because both edges of coils are
close as shown above
1
8
9
16
2
7
10
15
3
6
11
14
4
5
12
13
17
24
25
32
18
23
26
31
19
22
27
30
20
21
28
29
Beginning of Winding
High-frequency noise can hardly pass
through the Filter because both edges
of coil are not close as shown above
Standard Winding
Large inductance is available
Highly Efficient in Low Frequency
Sectional Winding
Excellent performance in high frequency
Stray capacity between windings is low
Frequency (MHz)
Insertion Loss (dB)
0.1 1 10 100
0
20
40
60
80
0.01
(Standard Winding)
(Sectional Winding)
Noise are generated from
Switching Power Supply
Common Mode Noise
Differential Mode Noise
PLA10/PLH10
Common Mode Choke Coil
suppresses Common
Mode Noise
Across the Line Capacitor
(X Capacitor) suppresses
Differential Mode Noise
Across the Line Capacitor
(X Capacitor) suppresses
Differential Mode Noise
Differential Mode Choke Coil
suppresses Differential Mode Noise
Differential Mode Choke Coil
suppresses Differential Mode
Noise
Line Bypass Capacitor
(Y Capacitor) suppresses
Common Mode Noise
Load
Switching
Power Supply
Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this PDF catalog to prevent smoking and/or burning, etc.
This catalog has only typical specifications. Therefore, you are requested to approve our product specifications or to transact the approval sheet for product specificaions before ordering.
!Note C09E6.pdf 03.3.10
5
1
!Note • Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this catalog to prevent smoking and/or burning, etc.
• This catalog has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering.
EMI Suppression Filters (EMIFILr) for AC Power Lines
Common Mode Choke Coil
The PLA10 series is a compact size AC common mode
choke coil. It can obtain a high inductance value in
spite of its compact size.
Features
1. Compact and light weight
2. Low profile in vertical core layout
3. Both a standard winding type and a sectional
winding type for higher frequency noise are
available. (in mm)
17.5 max.
18 max.
13±0.5 10±0.5
16 max.
ø0.9 max.
3.5±1
(1)
[(2)]
(4)
[(3)]
(4)
[(1)]
(3)
[(2)]
Standard Winding Type
(in mm)
17.5 max.
16 max.18 max.
13±0.5 10±0.5
ø0.9 max.
3.5±1
(1) (4)
[(2)]
(4)
[(1)]
(3)
[(2)][(3)]
Sectional Winding Type
PLA10 Series Standard Winding Type
Part Number Common Mode Inductance
(mH) Rated Current
(A) Rated Voltage
(V) Insulation Resistance
(M ohm)
PLA10AN1522R0R2 1.5 min. 2.0 300 100 min.
PLA10AN1821R7R2 1.8 min. 1.7 300 100 min.
PLA10AN2221R5R2 2.2 min. 1.5 300 100 min.
PLA10AN3021R3R2 3.0 min. 1.3 300 100 min.
PLA10AN3521R2R2 3.5 min. 1.2 300 100 min.
PLA10AN5521R0R2 5.5 min. 1.0 300 100 min.
PLA10AN7420R8R2 7.4 min. 0.8 300 100 min.
PLA10AN1030R7R2 10.0 min. 0.7 300 100 min.
PLA10AN1230R6R2 12.0 min. 0.6 300 100 min.
PLA10AN2030R5R2 20.0 min. 0.5 300 100 min.
PLA10AN3030R4R2 30.0 min. 0.4 300 100 min.
PLA10AN4330R3R2 43.0 min. 0.3 300 100 min.
Operating Temperature Range (Ambient Temperature Range + Winding Temperature Rise) : -25°C to 120°C Winding Temperature Rise (at Rated Current) : 60K max.
Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this PDF catalog to prevent smoking and/or burning, etc.
This catalog has only typical specifications. Therefore, you are requested to approve our product specifications or to transact the approval sheet for product specificaions before ordering.
!Note C09E6.pdf 03.3.10
6
1
!Note Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this catalog to prevent smoking and/or burning, etc.
This catalog has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering.
PLA10 Series Sectional Winding Type
Part Number Common Mode Inductance
(mH) Rated Current
(A) Rated Voltage
(V) Insulation Resistance
(M ohm)
PLA10AN9012R0D2 0.9 min. 2.0 300 100 min.
PLA10AN1321R7D2 1.3 min. 1.7 300 100 min.
PLA10AN1821R5D2 1.8 min. 1.5 300 100 min.
PLA10AN2021R3D2 2.0 min. 1.3 300 100 min.
PLA10AN3621R0D2 3.6 min. 1.0 300 100 min.
PLA10AN7720R7D2 7.7 min. 0.7 300 100 min.
PLA10AN1330R5D2 13.0 min. 0.5 300 100 min.
PLA10AN2230R4D2 22.0 min. 0.4 300 100 min.
PLA10AN3630R3D2 36.0 min. 0.3 300 100 min.
Operating Temperature Range (Ambient Temperature Range + Winding Temperature Rise) : -25°C to 120°C Winding Temperature Rise (at Rated Current) : 60K max.
Equivalent Circuit Diagram
(1)
(4)
(2)
(3)
N1
N2
N1 : N2 = 1 : 1
Insertion Loss Characteristics (Typical)
Standard Winding Type
0.1 1 10 100
0
20
40
60
80
0.01
Frequency (MHz)
PLA10AN1522R0R2
PLA10AN1821R7R2
PLA10AN2221R5R2
PLA10AN3021R3R2
PLA10AN3521R2R2
PLA10AN5521R0R2
Insertion Loss (dB)
PLA10AN7420R8R2
PLA10AN1030R7R2
PLA10AN1230R6R2
PLA10AN2030R5R2
PLA10AN3030R4R2
PLA10AN4330R3R2
Sectional Winding Type
0.1 1 10 100
0
20
40
60
80
0.01
Frequency (MHz)
Insertion Loss (dB)
PLA10AN9012R0D2
PLA10AN1321R7D2
PLA10AN1821R5D2
PLA10AN2021R3D2
PLA10AN3621R0D2
PLA10AN7720R7D2
PLA10AN1330R5D2
PLA10AN2230R4D2
PLA10AN3630R3D2
Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this PDF catalog to prevent smoking and/or burning, etc.
This catalog has only typical specifications. Therefore, you are requested to approve our product specifications or to transact the approval sheet for product specificaions before ordering.
!Note C09E6.pdf 03.3.10
7
1
!Note Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this catalog to prevent smoking and/or burning, etc.
This catalog has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering.
Features
1. Compact and light weight
2. Low profile in vertical core layout
3. Both a standard winding type and a sectional winding
type for higher frequency noise are available.
4. Safety standards : EN60065
Applications
Switching power supply, electric ballast
(AC-AC converter) (in mm)
17.5 max.
18 max.
13±0.5 10±0.5
16 max.
ø0.9 max.
3.5±1
(1)
[(2)]
(4)
[(3)]
(4)
[(1)]
(3)
[(2)]
Standard Winding Type
(in mm)
17.5 max.
16 max.18 max.
13±0.5 10±0.5
ø0.9 max.
3.5±1
(1) (4)
[(2)]
(4)
[(1)]
(3)
[(2)][(3)]
Sectional Winding Type
PLA10 Series (Safety Standard Recognized) Standard Winding Type
Part Number Common Mode Inductance
(mH) Rated Current
(A) Rated Voltage
(V) Insulation Resistance
(M ohm)
PLA10AS1522R0R2 1.5 min. 2.0 250 100 min.
PLA10AS1821R7R2 1.8 min. 1.7 250 100 min.
PLA10AS2221R5R2 2.2 min. 1.5 250 100 min.
PLA10AS3021R3R2 3.0 min. 1.3 250 100 min.
PLA10AS3521R2R2 3.5 min. 1.2 250 100 min.
PLA10AS5521R0R2 5.5 min. 1.0 250 100 min.
PLA10AS7420R8R2 7.4 min. 0.8 250 100 min.
PLA10AS1030R7R2 10.0 min. 0.7 250 100 min.
PLA10AS1230R6R2 12.0 min. 0.6 250 100 min.
PLA10AS2030R5R2 20.0 min. 0.5 250 100 min.
PLA10AS3030R4R2 30.0 min. 0.4 250 100 min.
PLA10AS4330R3R2 43.0 min. 0.3 250 100 min.
Operating Temperature Range : -25°C to 60°C Winding Temperature Rise (at Rated Current) : 60K max.
PLA10 Series (Safety Standard Recognized) Sectional Winding Type
Part Number Common Mode Inductance
(mH) Rated Current
(A) Rated Voltage
(V) Insulation Resistance
(M ohm)
PLA10AS9012R0D2 0.9 min. 2.0 250 100 min.
PLA10AS1321R7D2 1.3 min. 1.7 250 100 min.
PLA10AS1821R5D2 1.8 min. 1.5 250 100 min.
PLA10AS2021R3D2 2.0 min. 1.3 250 100 min.
PLA10AS3621R0D2 3.6 min. 1.0 250 100 min.
PLA10AS7720R7D2 7.7 min. 0.7 250 100 min.
PLA10AS1330R5D2 13.0 min. 0.5 250 100 min.
PLA10AS2230R4D2 22.0 min. 0.4 250 100 min.
PLA10AS3630R3D2 36.0 min. 0.3 250 100 min.
Operating Temperature Range : -25°C to 60°C Winding Temperature Rise (at Rated Current) : 60K max.
Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this PDF catalog to prevent smoking and/or burning, etc.
This catalog has only typical specifications. Therefore, you are requested to approve our product specifications or to transact the approval sheet for product specificaions before ordering.
!Note C09E6.pdf 03.3.10
8
1
!Note Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this catalog to prevent smoking and/or burning, etc.
This catalog has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering.
Equivalent Circuit Diagram
(1)
(4)
(2)
(3)
N1
N2
N1 : N2 = 1 : 1
Insertion Loss Characteristics (Typical)
Standard Winding Type
0.1 1 10 100
0
20
40
60
80
0.01
Frequency (MHz)
PLA10AS1522R0R2
PLA10AS1821R7R2
PLA10AS2221R5R2
PLA10AS3021R3R2
PLA10AS3521R2R2
PLA10AS5521R0R2
Insertion Loss (dB)
PLA10AS7420R8R2
PLA10AS1030R7R2
PLA10AS1230R6R2
PLA10AS2030R5R2
PLA10AS3030R4R2
PLA10AS4330R3R2
Sectional Winding Type
0.1 1 10 100
0
20
40
60
80
0.01
Frequency (MHz)
Insertion Loss (dB)
PLA10AS9012R0D2
PLA10AS1321R7D2
PLA10AS1821R5D2
PLA10AS2021R3D2
PLA10AS3621R0D2
PLA10AS7720R7D2
PLA10AS1330R5D2
PLA10AS2230R4D2
PLA10AS3630R3D2
Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this PDF catalog to prevent smoking and/or burning, etc.
This catalog has only typical specifications. Therefore, you are requested to approve our product specifications or to transact the approval sheet for product specificaions before ordering.
!Note C09E6.pdf 03.3.10
9
1
!Note Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this catalog to prevent smoking and/or burning, etc.
This catalog has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering.
PLH10 Series
The PLH10 series is a common mode choke coil for high
frequency use. The same dimensions as the PLA10 series
enables flexible design.
Features
1. High performance in high frequency range
2. Low profile in vertical core layout
3. Compact and light weight
17.5 max.
18 max.
13±0.5
(in mm)
10±0.5
16 max.
ø0.9 max.
3.5±1
(4)
[(1)]
(3)
[(2)]
(4)
[(3)]
(1)
[(2)]
Part Number Common Mode Inductance
(µH) Rated Current
(A) Rated Voltage
(V) Insulation Resistance
(M ohm)
PLH10AN7003R6P2 70 min. 3.6 300 100 min.
PLH10AN1112R6P2 110 min. 2.6 300 100 min.
PLH10AN1612R1P2 160 min. 2.1 300 100 min.
PLH10AN2211R5P2 220 min. 1.5 300 100 min.
PLH10AN2911R2P2 290 min. 1.2 300 100 min.
PLH10AN3711R0P2 370 min. 1.0 300 100 min.
Operating Temperature Range (Ambient Temperature Range + Winding Temperature Rise) : -25°C to 120°C Winding Temperature Rise (at Rated Current) : 60K max.
Equivalent Circuit Diagram
(1)
(4)
(2)
(3)
N1
N2
N1 : N2 = 1 : 1
Insertion Loss Characteristics (Typical)
Insertion Loss (dB)
Frequency (MHz)
0.1 1.0 10 1000
0
10
20
30
40
50 100
PLH10AN1112R6P2
PLH10AN1612R1P2
PLH10AN2211R5P2
PLH10AN2911R2P2
PLH10AN3711R0P2
PLH10AN7003R6P2
Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this PDF catalog to prevent smoking and/or burning, etc.
This catalog has only typical specifications. Therefore, you are requested to approve our product specifications or to transact the approval sheet for product specificaions before ordering.
!Note C09E6.pdf 03.3.10
10
1
!Note Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this catalog to prevent smoking and/or burning, etc.
This catalog has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering.
PLH10 Series (Safety Standard Recognized)
Features
1. High performance in high frequency range
2. Low profile in vertical core layout
3. Compact and light weight
4. Safety standards : EN60065
Applications
Suppressing radiation noise in switching power supply
and inverter (AC-AC converter)
17.5 max.
18 max.
13±0.5
(in mm)
10±0.5
16 max.
ø0.9 max.
3.5±1
(4)
[(1)]
(3)
[(2)]
(4)
[(3)]
(1)
[(2)]
Part Number Common Mode Inductance
(µH) Rated Current
(A) Rated Voltage
(V) Insulation Resistance
(M ohm)
PLH10AS7003R6P2 70 min. 3.6 250 100 min.
PLH10AS1112R6P2 110 min. 2.6 250 100 min.
PLH10AS1612R1P2 160 min. 2.1 250 100 min.
PLH10AS2211R5P2 220 min. 1.5 250 100 min.
PLH10AS2911R2P2 290 min. 1.2 250 100 min.
PLH10AS3711R0P2 370 min. 1.0 250 100 min.
Operating Temperature Range : -25°C to 60°C Winding Temperature Rise (at Rated Current) : 60K max.
Equivalent Circuit Diagram
(1)
(4)
(2)
(3)
N1
N2
N1 : N2 = 1 : 1
Insertion Loss Characteristics (Typical)
Insertion Loss (dB)
Frequency (MHz)
0.1 1.0 10 1000
0
10
20
30
40
50 100
PLH10AS1112R6P2
PLH10AS1612R1P2
PLH10AS2211R5P2
PLH10AS2911R2P2
PLH10AS3711R0P2
PLH10AS7003R6P2
Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this PDF catalog to prevent smoking and/or burning, etc.
This catalog has only typical specifications. Therefore, you are requested to approve our product specifications or to transact the approval sheet for product specificaions before ordering.
!Note C09E6.pdf 03.3.10
11
2
!Note Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this catalog to prevent smoking and/or burning, etc.
This catalog has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering.
EMI Suppression Filters (EMIFILr) for AC Power Lines
Hybrid Choke Coil
The PLY10 is a compact and high performance hybrid
choke coil which can handle differential mode noise
caused by the harmonics currents regulation circuit as
well as common mode noise. It can handle noise
problems much more compactly than a combination of a
conventional common mode choke coil and differential
mode choke coil.
Features
1. PLY10 has both functions of a common mode choke
coil and a differential mode choke coil in its
compact body.
2. Low profile in vertical core layout
3. PLY10 has the same pin layout as a general type
common mode choke coil which enables it to replace
conventional components.
EMI Problem for harmonics currents regulation
There are some methods meet harmonics currents
regulations (IEC1000-3, EN60555-2) such as active
filter type and one converter type. However, they
cause new EMI problems of differential mode noise
because they use active components. For that reason,
additional filter components to meet differential mode
noise must be applied.
17.5 max.
18 max.
13±0.5 10±0.5
16 max.
ø0.9 max.
(in mm)
3.5±1
(4)
[(1)]
(3)
[(2)]
(4)
[(3)]
(1)
[(2)]
Standard Winding Type
17.5 max.
18 max.
13±0.5 10±0.5
(in mm)
16 max.
ø0.9 max.
3.5±1
(4)
[(1)]
(3)
[(2)]
(4)
[(3)]
(1)
[(2)]
Sectional Winding Type
PLY10 Series Standard Winding Type
Part Number Common Mode Inductance
(mH) Normal Mode Inductance
(mH) Rated Current
(A) Rated Voltage
(Vac)
PLY10AN1430R5R2 14.0 min. 1.0 min. 0.5 300
PLY10AN9920R6R2 9.9 min. 0.69 min. 0.6 300
PLY10AN8720R7R2 8.7 min. 0.53 min. 0.7 300
PLY10AN6220R8R2 6.2 min. 0.40 min. 0.8 300
PLY10AN4321R0R2 4.3 min. 0.30 min. 1.0 300
PLY10AN2821R2R2 2.8 min. 0.19 min. 1.2 300
PLY10AN2121R4R2 2.1 min. 0.15 min. 1.4 300
PLY10AN1521R6R2 1.5 min. 0.11 min. 1.6 300
PLY10AN1121R8R2 1.1 min. 0.09 min. 1.8 300
PLY10AN9012R0R2 0.9 min. 0.065 min. 2.0 300
Operating Temperature (Ambient Temperature Range + Winding Temperature Rise) : -25°C to 120°C Winding Temperature Rise (at Rated Current) : 60K max.
PLY10 Series Sectional Winding Type
Part Number Common Mode Inductance
(mH) Normal Mode Inductance
(mH) Rated Current
(A) Rated Voltage
(Vac)
PLY10AN1130R5D2 11.0 min. 0.84 min. 0.5 300
PLY10AN9720R6D2 9.7 min. 0.67 min. 0.6 300
PLY10AN8720R7D2 8.7 min. 0.50 min. 0.7 300
PLY10AN4420R8D2 4.4 min. 0.32 min. 0.8 300
PLY10AN3521R0D2 3.5 min. 0.24 min. 1.0 300
Continued on the following page.
Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this PDF catalog to prevent smoking and/or burning, etc.
This catalog has only typical specifications. Therefore, you are requested to approve our product specifications or to transact the approval sheet for product specificaions before ordering.
!Note C09E6.pdf 03.3.10
12
2
!Note Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this catalog to prevent smoking and/or burning, etc.
This catalog has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering.
Part Number Common Mode Inductance
(mH) Normal Mode Inductance
(mH) Rated Current
(A) Rated Voltage
(Vac)
Continued from the preceding page.
PLY10AN2321R2D2 2.3 min. 0.16 min. 1.2 300
PLY10AN1421R4D2 1.4 min. 0.11 min. 1.4 300
PLY10AN1121R7D2 1.1 min. 0.065 min. 1.7 300
PLY10AN7012R0D2 0.7 min. 0.050 min. 2.0 300
Operating Temperature (Ambient Temperature Range + Winding Temperature Rise) : -25°C to 120°C Winding Temperature Rise (at Rated Current) : 60K max.
Equivalent Circuit Diagram
Common Mode Inductor
Differential Mode Inductor
(1) (2)
(3)
(4)
Common Mode Insertion Loss Characteristics (Typical)
Standard Winding Type
0.1 1 10 100
0
20
40
60
80
0.01
Frequency (MHz)
Insertion Loss (dB)
PLY10AN9012R0R2
PLY10AN1121R8R2
PLY10AN1521R6R2
PLY10AN2121R4R2
PLY10AN2821R2R2
PLY10AN4321R0R2
PLY10AN6220R8R2
PLY10AN8720R7R2
PLY10AN9920R6R2
PLY10AN1430R5R2
Sectional Winding Type
0.1 1 10 100
0
20
40
60
80
0.01
Frequency (MHz)
Insertion Loss (dB)
PLY10AN7012R0D2
PLY10AN1121R7D2
PLY10AN1421R4D2
PLY10AN2321R2D2
PLY10AN3521R0D2
PLY10AN4420R8D2
PLY10AN8720R7D2
PLY10AN9720R6D2
PLY10AN1130R5D2
Differential Mode Insertion Loss Characteristics (Typical)
Standard Winding Type
0.1 1 10 100
0
20
40
60
80
0.01
Frequency (MHz)
Insertion Loss (dB)
PLY10AN2121R4R2
PLY10AN2821R2R2
PLY10AN4321R0R2
PLY10AN6220R8R2
PLY10AN8720R7R2
PLY10AN9920R6R2
PLY10AN1430R5R2
PLY10AN9012R0R2
PLY10AN1121R8R2
PLY10AN1521R6R2
Sectional Winding Type
0.1 1 10 100
0
20
40
60
80
0.01
Frequency (MHz)
Insertion Loss (dB)
PLY10AN2321R2D2
PLY10AN3521R0D2
PLY10AN4420R8D2
PLY10AN8720R7D2
PLY10AN9720R6D2
PLY10AN1130R5D2
PLY10AN7012R0D2
PLY10AN1121R7D2
PLY10AN1421R4D2
Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this PDF catalog to prevent smoking and/or burning, etc.
This catalog has only typical specifications. Therefore, you are requested to approve our product specifications or to transact the approval sheet for product specificaions before ordering.
!Note C09E6.pdf 03.3.10
Noise Suppression Effect of PLY10 Series
13
2
!Note Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this catalog to prevent smoking and/or burning, etc.
This catalog has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering.
The data shows noise suppression effects comparison PLY10 with existing common mode choke coil. (In AC adaptor of note PC)
• Noise Level
The filter circuit with hybrid choke coil has suppressed conducted noise as well as conventional filter in spite of its compact
composition.
1000pF680µH
0.1µF0.33µF
Common mode choke coil and differentical mode choke coil are used. Hybrid choke coil PLY10
24mH 1000pF
0.1µF0.33µF
PLY10A1130R5D
90
80
70
60
50
40
30
20
0.5 1 5 10 30
Frequency (MHz)
Noise Level (dBµV)
90
80
70
60
50
40
30
20
0.5 1 5 10 30
Frequency (MHz)
Common mode choke coil and differencial mode choke coil are used. Hybrid choke coil PLY10
Noise Level (dBµV)
Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this PDF catalog to prevent smoking and/or burning, etc.
This catalog has only typical specifications. Therefore, you are requested to approve our product specifications or to transact the approval sheet for product specificaions before ordering.
!Note C09E6.pdf 03.3.10
!Caution /Notice
14
2
!Note Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this catalog to prevent smoking and/or burning, etc.
This catalog has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering.
!Caution (Rating)
1. Rated Current
Operating current should not exceed the rated value.
Even if operating current is under the rated value,
adequate ventilation is required to avoid excessive
heat generated within the product (choke coil) and
from surrounding heat sources.
If exceeding these conditions, excessive heat may
cause fumes or permanent damage to the product.
Please ensure that product (choke coil) is evaluated
and confirmed against the specification when it is
mounted in your final assembled product. -> Winding
temperature should be less than 120 degree C.
Maximum allowable temperature at the surface of coil
(ambient temperature + winding temperature rise) is
in accordance with each safety standard applicable
to final assembeld product.
When the temperature at winding exceeds maximum
allowable temperature of safety standard, the rated
current should be derated.
2. Inrush Current
Inrush current should not exceed 10 times rated
current within 1/4 cycle of 50/60Hz commercial
power line. Inrush current should be limited to a
minimum of 10 seconds after last inrush.
If these conditions are exceeded, excessive heat
may cause fumes or permanent damage to the
component, or at worst cause ignition.
Notice (Storage and Operating Condition)
1. Soldering Conditions
(1) Flux, solder
Rosin-based flux should be used.
Do not use strong acidic flux with halide
content exceeding 0.2%wt
(chlorine conversion value)
Use 63/37 solder (Sn 63%/Pb 37%) or 60/40
solder (Sn 60%/Pb 40%)
(2) Flow soldering
Products should be soldered by flow method
under the following conditions:
Soldering Temp. : 240 to 260 degree C
Soldering Time : Less than 5 s
2. Cleaning
Avoid cleaning product due to non-waterproof
construction.
3. Storage and handling requirements
(1) Storage period
Product should be used within 12 months after
receiving.
Solderability should be checked if this period
is exceeded.
(2) Storage conditions
Storage temperature : -10 to 40 degree C
Relative humidity : 30 to 70%
Avoid sudden changes in temperature and humidity.
Don't keep products in corrosive gases such as
sulfur, chlorine gas or acid, or it may cause
oxidation of lead terminals resulting in poor
solderability or corrosion of component windings.
(3) Handling conditions
Care should be taken when transporting or
handling product to avoid excessive vibration or
mechanical shock.
Notice (Soldering and Mounting)
Magnetic Flux Leakage
Choke coils generate small amounts of magnetic flux
leakage that may adversely affect equipment operation
according to component arrangement.
Testing should be completed on final assembly to
ensure equipment performance is not affected.
Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this PDF catalog to prevent smoking and/or burning, etc.
This catalog has only typical specifications. Therefore, you are requested to approve our product specifications or to transact the approval sheet for product specificaions before ordering.
!Note C09E6.pdf 03.3.10
!Caution /Notice
15
2
!Note Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this catalog to prevent smoking and/or burning, etc.
This catalog has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering.
Notice (Rating)
Coil Humming Noise
Magnetic flux generated between coil and core or
between the choke coil windings creates repulsive
power between the coil windings. This repulsive
power causes the coil winding to vibrate and create
a humming noise. The amount of hum produced by the
coil is proportionate to the amount of harmonic
distortion generated by the operating current. This
does not influence the electrical performance of
the coils, but it should be considered and tested
in actual circuit application.
Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this PDF catalog to prevent smoking and/or burning, etc.
This catalog has only typical specifications. Therefore, you are requested to approve our product specifications or to transact the approval sheet for product specificaions before ordering.
!Note C09E6.pdf 03.3.10
Packaging
16
2
!Note Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this catalog to prevent smoking and/or burning, etc.
This catalog has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering.
Minimum Quantity
Part Number
PLA10
PLH10
PLY10
30
30
30
Magazine Package
210
210
200
Box
Minimum Quantity (pcs.)
Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this PDF catalog to prevent smoking and/or burning, etc.
This catalog has only typical specifications. Therefore, you are requested to approve our product specifications or to transact the approval sheet for product specificaions before ordering.
!Note C09E6.pdf 03.3.10
Head Office
2-26-10, Tenjin Nagaokakyo-shi, Kyoto 617-8555, Japan Phone: 81-75-951-9111 International Division
3-29-12, Shibuya, Shibuya-ku, Tokyo 150-0002, Japan
Phone: 81-3-5469-6123 Fax: 81-3-5469-6155 E-mail: intl@murata.co.jp
http://www.murata.com/
Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this PDF catalog to prevent smoking and/or burning, etc.
This catalog has only typical specifications. Therefore, you are requested to approve our product specifications or to transact the approval sheet for product specificaions before ordering.
!Note C09E6.pdf 03.3.10
Note:
1. Export Control
<
For customers outside Japan
>
Murata products should not be used or sold for use in the development, production, stockpiling or utilization of any conventional weapons or mass-destructive
weapons (nuclear weapons, chemical or biological weapons, or missiles), or any other weapons.
<
For customers in Japan
>
For products which are controlled items subject to the “Foreign Exchange and Foreign Trade Law” of Japan, the export license specified by the law is required
for export.
2. Please contact our sales representatives or product engineers before using the products in this catalog for the applications listed below, which require especially
high reliability for the prevention of defects which might directly damage to a third party's life, body or property, or when one of our products is intended for use
in applications other than those specified in this catalog.
qAircraft equipment wAerospace equipment
eUndersea equipment rPower plant equipment
tMedical equipment yTransportation equipment (vehicles, trains, ships, etc.)
uTraffic signal equipment iDisaster prevention / crime prevention equipment
oData-processing equipment !0 Application of similar complexity and/or reliability requirements to the applications listed in the above
3. Product specifications in this catalog are as of January 2003. They are subject to change or our products in it may be discontinued without advance notice.
Please check with our sales representatives or product engineers before ordering. If there are any questions, please contact our sales representatives or
product engineers.
4. Please read rating and CAUTION (for storage, operating, rating, soldering, mounting and handling) in this catalog to prevent smoking and/or burning, etc.
5. This catalog has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or
transact the approval sheet for product specifications before ordering.
6. Please note that unless otherwise specified, we shall assume no responsibility whatsoever for any conflict or dispute that may occur in connection with the effect
of our and/or a third party's intellectual property rights and other related rights in consideration of your use of our products and/or information described or
contained in our catalogs. In this connection, no representation shall be made to the effect that any third parties are authorized to use the rights mentioned
above under licenses without our consent.
7. No ozone depleting substances (ODS) under the Montreal Protocol are used in our manufacturing process.