(888) IPD-CONVerters (888) 473-2668 www.ipdconverters.com IAD SERIES - DUAL OUTPUT, 12 WATT DESCRIPTION FEATURES IAD dual output DC/DC converters provide up to 12 Watts of output power in an industry standard package and footprint. With a maximum case temperature of 100C, the IAD is well suited for the most demanding applications. The IAD features 1500 VDC isolation, short circuit, and overtemperature protection, as well as six-sided shielding. The IAD is available with optional enable and voltage trim pins. Please see the IAS series for single output applications. * Industry Standard Package * Industry Standard Footprint * Fixed Frequency Design * 100C Case Operation * Optional Trim and Enable * Wide Range Input * 1500V Isolation * Short Circuit Protection TECHNICAL SPECIFICATIONS Input Voltage Range 24 VDC Nominal 48 VDC Nominal Reflected Ripple Input Reverse Voltage Protection 18 - 36 VDC 34 - 75 VDC 25 mA Shunt Diode Efficiency vs. Load (48V Input) Output 1% 5% 0.5% V out 1.0% V out 10 % Iout Rated 25% Iout 4% Vout 500 s 10% Hiccup 110 - 150% 85 80 EFFICIENCY % Setpoint Accuracy Auxillary Setpoint Accuracy Line Regulation Vin Min. - Vin Max., Iout Rated Load Regulation Iout Min. - Iout Max., Vin Nom. Minimum Output Current Dynamic Regulation, Loadstep Pk Deviation Settling Time Voltage Trim Range Short Circuit / Overcurrent Protection Power Limit Threshold Range 90 75 70 EFF. IAD010ZGG EFF. IAD012ZHH 65 EFF. IAD012ZJJ 60 55 50 10 20 30 40 50 60 70 80 90 100 LOAD % General Turn-On Time Remote Shutdown Switching Frequency Isolation Input - Output Output - Case (for 48 Vin) Input - Case (for 24 Vin) Temperature Coefficient Case Temperature Operating Range Storage Range Humidity Max., Non-Condensing Vibration, 3 Axes, 5 Min Each MTBF (Bellcore TR-NWT-000332) Safety Weight (Approx.) 300 ms Positive Logic 400 kHz 1500 VDC 500 VDC 1050 VDC 0.03%/C -40 To +85C -40 To +110C 95% 5 g, 10 - 55 Hz 1.8 X 106 hrs UL, CUL, VDE 1.2 oz C-70 Notes MTBF predictions may vary slightly from model to model. Industrial temp range available Specifications typically at 25C, normal line, and full load, unless otherwise stated. Soldering Conditions: I/O pins, 260C, ten seconds; fully compatible with commercial wave-soldering equipment. Safety: Agency approvals may vary from model to model. Please consult factory for specific model information. Units are water-washable and fully compatible with commercial spray or immersion post wave-solder washing equipment. IAD SERIES - DUAL OUTPUT, 12 WATT MODELS - (See the last page of this file for options.) Vin (Volts) Vin Range (Volts) Iin Max.* (Amps) Vout (Volts) Iout Rated (Amps) Ripple & Noise Pk-Pk (mV) Efficiency Typ. ** Model 24 24 24 48 48 48 18 - 36 18 - 36 18 - 36 34 - 75 34 - 75 34 - 75 0.80 0.85 0.85 0.40 0.43 0.42 5 12 15 5 12 15 1.0 0.5 0.4 1.0 0.5 0.4 75 120 150 75 120 150 77% 82% 83% 78% 82% 83% IAD010YGG IAD012YHH IAD012YJJ IAD010ZGG IAD012ZHH IAD012ZJJ Denotes advanced product release. Consult factory for product availability. * Maximum input current at minimum input voltage, maximum rated output power. ** At nominal Vin, rated output. MECHANICAL DRAWING 1.00" (25.4mm) 0.18" MIN. (4.6mm) BOTTOM VIEW 0 4 5 6 DIA 0.040" (1.0mm) 2.00" (50.8mm) 1 0.800"(20.3mm) 3 2 1.40"(35.6mm) 0.42" (10.7mm) 0.900" (22.9mm) 0 0.300" (7.6mm) 0.800" (20.3mm) 0.500" (12.7mm) 0.400" (10.2mm) Thermal Impedance Natural Convection 100 LFM 200 LFM 300 LFM 400 LFM 15.4 12.2 9.3 7.4 6.4 C/W C/W C/W C/W C/W Note: Thermal impedance data is dependent on many environmental factors. The exact thermal performance should be validated for specific application. Pin Tolerances Function 1 2 3 +Vin -Vin Optional Shutdown +V out Common -V out 4 5 6 Inches: .XX 0.020 .XXX 0.010 (Millimeters) .X 0.5 .XX 0.25 Pin: 0.002 0.05 Case: + 0.04, - 0.00 + 1.0, - 0.0 (Tolerances as listed unless otherwise specified.) C-71 OPTIONS When ordering equipment options, use the following suffix information. Select the option(s) that you prefer and add them to the model number. Example ordering options are located below the options table. OPTION SUFFIX APPLICABLE SERIES Negative Logic N HAS, HBD, HBS, HES, LES, QBS, QES, TES, TQD Lucent Compatible Trim T HAS, HBD, HBS, HES, QBS, QES Terminal Strip TS REMARKS TTL "Low" Turns Module ON TTL "High" Turns Module OFF XWS, XWD, XWT Trim 1 IAS, LES Enable 2 IAD, IAS, LES, SMS Trim and Enable 3 IAS, LES Current Share 4 SMS Headerless Y Encapsulated EWS, IWS, OWS PIN LENGTH AND HEATSINK OPTIONS Standard Pin Length is 0.180" (4.6mm) 0.110" (2.8mm) Pin Length 8 All Units (Except SMS) 0.150" (3.8mm) Pin Length 9 All Units (Except SMS) 0.24" (6.1mm) Horizontal Heatsink 1H All Units (Except DIP, SIP, and SM Packages) Includes Thermal Pad 0.24" (6.1mm) Vertical Heatsink 1V All Units (Except DIP, SIP, and SM Packages) Includes Thermal Pad 0.45" (11.4mm) Horizontal Heatsink 2H All Units (Except DIP, SIP, and SM Packages) Includes Thermal Pad 0.45" (11.4mm) Vertical Heatsink 2V All Units (Except DIP, SIP, and SM Packages) Includes Thermal Pad 0.95" (24.1mm) Horizontal Heatsink 3H All Units (Except DIP, SIP, and SM Packages) Includes Thermal Pad 0.95" (24.1mm) Vertical Heatsink 3V All Units (Except DIP, SIP, and SM Packages) Includes Thermal Pad Example Options:HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent compatible trim, and 0.95" vertical heatsink. LES015YJ-3N = LES015YJ with optional trim and enable, negative logic. QBS066ZG-AT8 = QBS066ZG-A with Lucent compatible trim and 0.110" pin length. NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc. TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. C105