(888) IPD-CONVerters (888) 473-2668 www.ipdconverters.com
C-70
50
55
60
65
70
75
80
85
90
10 20 30 40 50 60 70 80 90 100
LOAD %
EFFICIENCY
%
EFF. IAD0 10 Z G G
EFF. IAD0 12 Z H H
EFF. IAD0 12 Z J J
DESCRIPTION FEATURES
IAD SERIES - DUAL OUTPUT, 12 WATT
Industry Standard
Package
Industry Standard
Footprint
Fixed Frequency Design
100°C Case Operation
Optional Trim and
Enable
Wide Range Input
1500V Isolation
Short Circuit Protection
IAD dual output DC/DC converters provide up to 12
Watts of output power in an industry standard package
and footprint. With a maximum case temperature of
100°C, the IAD is well suited for the most demanding
applications. The IAD features 1500 VDC isolation,
short circuit, and overtemperature protection, as well as
six-sided shielding. The IAD is available with optional
enable and voltage trim pins. Please see the IAS series for
single output applications.
Efficiency vs. Load (48V Input)
General
Turn-On Time 300 ms
Remote Shutdown Positive Logic
Switching Frequency 400 kHz
Isolation
Input - Output 1500 VDC
Output - Case (for 48 Vin) 500 VDC
Input - Case (for 24 Vin) 1050 VDC
Temperature Coefficient ±0.03%/°C
Case Temperature
Operating Range -40 To +85°C
Storage Range -40 To +110°C
Humidity Max., Non-Condensing 95%
Vibration, 3 Axes, 5 Min Each 5 g, 10 - 55 Hz
MTBF (Bellcore TR-NWT-000332) 1.8 X 106 hrs
Safety UL, CUL, VDE
Weight (Approx.) 1.2 oz
Notes
MTBF predictions may vary slightly from model to model.
†† Industrial temp range available
Specifications typically at 25°C, normal line, and full load, unless otherwise stated.
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with
commercial wave-soldering equipment.
Safety: Agency approvals may vary from model to model. Please consult factory
for specific model information.
Units are water-washable and fully compatible with commercial spray or immersion
post wave-solder washing equipment.
TECHNICAL SPECIFICA TIONS
Voltage Range
24 VDC Nominal 18 - 36 VDC
48 VDC Nominal 34 - 75 VDC
Reflected Ripple 25 mA
Input Reverse Voltage Protection Shunt Diode
Input
Output
Setpoint Accuracy ±1%
Auxillary Setpoint Accuracy 5 %
Line Regulation Vin Min. - Vin Max., Iout Rated 0.5% Vout
Load Regulation Iout Min. - Iout Max., Vin Nom. 1.0% Vout
Minimum Output Current 10 % Iout Rated
Dynamic Regulation, Loadstep 25% Iout
Pk Deviation 4% Vout
Settling Time 500 µs
Voltage Trim Range ±10%
Short Circuit / Overcurrent Protection Hiccup
Power Limit Threshold Range 110 - 150%
C-71
Thermal Impedance
Natural Convection 15.4 °C/W
100 LFM 12.2 °C/W
200 LFM 9.3 °C/W
300 LFM 7.4 °C/W
400 LFM 6.4 °C/W
Note:
Thermal impedance data is dependent on
many environmental factors. The exact
thermal performance should be validated
for specific application.
IAD SERIES - DUAL OUTPUT, 12 WATT
MECHANICAL DRAWING
1+V
in
2-V
in
3 Optional
Shutdown
4+V
out
5 Common
6-V
out
Pin Function Tolerances
Inches: (Millimeters)
.XX ± 0.020 .X ± 0.5
.XXX ± 0.010 .XX ± 0.25
Pin:
± 0.002 ± 0.05
Case:
+ 0.04, - 0.00 + 1.0, - 0.0
(T olerances as listed unless otherwise specified.)
MODELS - (See the last page of this file for options.)
Vin
(Volts) V i n Range
(Volts) Iin Max.*
(Amps) Vout
(Volts) Iout Rated
(Amps) Ri p p le & No is e
Pk-Pk (mV ) Efficiency
Typ. ** Model
24
24
24
48
48
48
18 - 36
18 - 36
18 - 36
34 - 75
34 - 75
34 - 75
0.80
0.85
0.85
0.40
0.43
0.42
±5
±12
±15
±5
±12
±15
±1.0
±0.5
±0.4
±1.0
±0.5
±0.4
75
120
150
75
120
150
77%
82%
83%
78%
82%
83%
IAD010YGG
IAD012YHH
IAD012YJJ
IAD010ZGG
IAD012ZHH
IAD012ZJJ
† De note s advanc e d pro duc t releas e . Co ns ul t fac tory fo r p r o duct av ai l a b i l ity.
* Max i mum inp ut c urre nt at mini mum inp ut v o l tage , maxi mum rated outp ut p o we r.
** A t nomi nal V i n, rate d o utp u t.
DIA 0.040"
(1.0mm)
0.18" MIN.
(4.6mm)
0.42"
(10.7mm)
1.00"
(25.4mm)
2.00"
(50.8mm)
0
0.800"(20.3mm)
BOTTOM VIEW
1.40"(35.6mm)
3
21
465
0
0.300"
(7.6mm)
0.400"
(10.2mm)
0.500"
(12.7mm)
0.800"
(20.3mm)
0.900"
(22.9mm)
C105
OPTIONS
When ordering equipment options, use the following suffix information. Select the option(s) that
you prefer and add them to the model number. Example ordering options are located below the
options table.
OPTION SUFFIX APPLICABLE SERIES REMARKS
Negative Logic N HAS, HBD, HBS, HES, LES, QBS,
QES, TES, TQD TTL “Low” Turns Module ON
TTL “High” Turns Module OFF
Lucent Compatible Trim T HAS, HBD, HBS, HES, QBS, QES
Terminal Strip TS XWS, XWD, XWT
Trim 1 IAS, LES
Enable 2 IAD, IAS, LES, SMS
Trim and Enable 3 IAS, LES
Current Share 4 SMS
Headerless Y E ncapsulated EWS, IWS, OWS
PIN LENGTH A ND HEAT SINK
OPTIONS Standard Pin Length is 0.180”
(4.6mm)
0.110” (2.8mm) Pin Length 8 All Units (Except SMS)
0.150” (3.8mm) Pin Length 9 All Units (Except SMS)
0.24” (6.1mm) Horizontal Heatsi nk 1H All Units (Except DIP, SIP, and SM
Packages) Includes Thermal Pad
0.24” (6.1mm) Vertical Heatsink 1V All Units (Except DIP, SIP, and SM
Packages) Includes Thermal Pad
0.45” (11.4mm) Horizontal
Heatsink 2H All Units (Except DIP, SIP, and SM
Packages) Includes Thermal Pad
0.45” (11.4mm) Vertical Heatsink 2V All Units (Except DIP, SIP, and SM
Packages) Includes Thermal Pad
0.95” (24.1mm) Horizontal
Heatsink 3H All Units (Except DIP, SIP, and SM
Packages) Includes Thermal Pad
0.95” (24.1mm) Vertical Heatsink 3V All Units (Except DIP, SIP, and SM
Packages) Includes Thermal Pad
Example Options:HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent compatible trim, and
0.95” vertical heatsink.
LES015YJ-3N = LES015YJ with optional trim and enable, negative logic.
QBS066ZG-AT8 = QBS066ZG-A with Lucent compatible trim and 0.110” pin length.
NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.