SPECIFICATION CONTROL DRAWING 44A182X TTLE TWO CONDUCTOR CABLE, RADIATION-CROSSLINKED, POLYALKENE-INSULATED, SHIELDED, JACKETED, MEDIUMWEIGHT, AIRFRAME, 600 VOLT Date Revision 9-15-97 This specification sheet forms a part of the latest issue of Raychem Specification 44 PART NUMBER 44A182X-16-* 182X-14-* 1 -12-* * 4443 32X-_ 8-* PART NUMBER 44A18 44A182X-16-* 44A18 44A1 44A1 SHIELD - COPPER, COATING SAME AS ON CONDUCTOR EXCEPT TIN-COATED SHIELD WITH SILVER-COATED HIGH STRENGTH ALLOY CONDUCTOR COMPONENT WIRES - 44A081X CONDUCTOR SIZE (AWG) IMMERSION, LIFE CYCLE AND ACCELERATED AGING NOTE: Nominal values are for information only. - Nominal values are not requirements. TABLE |. CABLE CONSTRUCTION DETAILS TABLE Il. CABLE PERFORMANCE DETAILS BEND TESTING MANDREL DIAMETER JACKET~- RADIATION-CROSSLINKED, MODIFIED PVF, OUTSIDE DIAMETER MAXIMUM WEIGHT (in.) (Ib/1000 ft) NOMINAL | MAXIMUM 14 153 14. WEIGHT (Ib) (+ 3%) IMMERSION, LIFE CYCLE AND ACCELERATED AGING 500 COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL. Raychem THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN. REFERENCED Page 1 of 2 DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID. Raychem Corporation 300 Constitution Drive, Menio Park, California 94025 1-800-2 Raychem Fax 1-650-361-6297Raychem Page 2 of 2 se Number 44A182X SPECIFICATION CONTROL DRAWING CABLE RATINGS AND ADDITIONAL REQUIREMENTS TEMPERATURE RATING: 150C Maximum continuous conductor temperature VOLTAGE RATING: 600 volts (rms) ACCELERATED AGING: 300 + 3C for6 hours BLOCKING: 150 + 3C for6 hours DIELECTRIC WITHSTAND: 2500 voits (rms), 60 Hz, 1 minute FLAMMABILITY: 30 seconds (maximum); 3 in. (maximum); no flaming of facial tissue IMMERSION: Diameter increase 5% (maximum); no cracking, no dielectric breakdown JACKET COLOR: White preferred JACKET CONCENTRICITY: 70% (minimum) JACKET ELONGATION AND TENSILE STRENGTH: Elongation, 200% (minimum) Tensile Strength, 4000 Ibf/in? (minimum) JACKET FLAWS: Spark Test, 1.5 kV (rms), 60 Hz, 100% test impulse Dielectric Test, 6.0 kV (peak), 100% test LIFE CYCLE: 200 + 3C for 168 hours LOW TEMPERATURE-COLD BEND: -65 + 2C for 4 hours SHIELD COVERAGE: 85% (minimum) VOLTAGE WITHSTAND TEST (POST ENVIRONMENTAL): 1000 volts (rms), 60 Hz, 1 minute PART NUMBER: The "X" in the part numbers on page 1 shall be replaced by the applicable conductor material designator as follows: 1 tin-coated copper 2 silver-coated copper 3 nickel-coated copper 4 silver-coated high strength copper alloy (AWG's 26 - 20 only) 6 nickel-coated high strength copper alloy (AWG's 26 - 20 only) The * in the part numbers on page 1 shall be replaced by color code designators with a slash separating the component wire colors and a dash separating the component wire colors from the jacket color. Example: AWG 20, tin-coated copper wire; white and black component wires; white jacket; 44A1821-20-9/0-9