Fluke 113 Utility Multimeter Technical Data True RMS Utility Multimeter designed for basic electrical tests The new 113 Utility Multimeter has the features needed to repair most electrical problems. This meter is simple to use and has significant improvements over Fluke's original 7-600, and other utility multimeters. With features such as Fluke's VCHEKTM, added measurement functions, backlight, conformance to the latest safety standards, and a much larger display that's easier to view, this new meter is a must have for the utility users toolbox. Features include: * * * * * * * * * R N10140 VCHEKTM LoZ low impedance measurement function to simultaneously test for voltage and continuity True-rms for accurate ac measurements on non-linear loads A large backlit display allows for easy visibility in low-lit areas Record signal fluctuations using the Min/Max function Diode test for testing general-purpose germanium, silicon, and power diodes Integral holster with probe holders for easy storage Auto and Manual ranging for added user functionality Meets Measurement Category CAT III 600 V and Category IV 300 V standards for a higher level of safety The optional TPAK magnetic hanger allows the user hands-free flexibility Specifications Accuracy is specified for 1 year after calibration, at operating temperatures of 18 C to 28 C, with relative humidity at 0 % to 95 %. Accuracy specifications are given as follows: Note: Specifications are subject to change without notice. ( [ % of reading ] + [ number of least significant digits ] ) Function Range Chek1,2 Function 3 Resolution 6.000 V 60.00 V 600.0 V 0.001 V 0.01 V 0.1 V Range Resolution 2.000 V 0.001 V Accuracy Ordering information Fluke 113 Utility Meter DC, 45 to 500 Hz 500 Hz to 1 kHz 2.0 % + 3 4.0 % + 3 Accuracy Included Fluke 113 Utility Multimeter TL75 Test Leads One 9V Battery Printed Users Manual 2.0 % + 3 3 Beeper on < 20 , off > 250 ; detects opens or shorts of 500 s or longer 600.0 6.000 k 60.00 k 1000 nF 10.00 F 100.0 F 9999 F W3 3 0.1 0.001 k 0.01 k 1 nF 0.01 F 0.1 F 1 F 0.9 % + 2 0.9 % + 1 0.9 % + 1 1.9 % + 2 1.9 % + 2 1.9 % + 2 100 F - 1000 F: 1.9 % + 2 > 1000 F: 5 % + 20 Notes: 1 All Chek voltage ranges are specified from 60 counts to 100 % of range. Because inputs below 60 counts are not specified, it is possible and normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together. 2 Crest factor of 3 at 4000 counts, decreasing linearly to 1.5 at full scale. 3 After measuring voltage, a wait time of 1 minute is required to maintain accuracy of ohms, capacitance, diode test, and continuity. Maximum voltage between any terminal and earth ground Display Operating temperature Storage temperature Temperature coefficient Operating altitude Storage altitude Relative humidity Battery type Battery life Shock Vibration Size (HxWxL) Weight Safety EMI regulations Function Chek W 600 V 3 3/4-digits, 6000 counts, updates 4/sec -10 C to 50 C (14 F to 122 F) -40 C to 60 C (-22 F to 140 F) 0.1 x (specified accuracy)/C (< 18 C or > 28 C) 2,000 m 10,000 m 95 % to 30 C 75 % to 40 C 45 % to 50 C 9 Volt Alkaline, ANSI 1604A / IEC 6F22 Alkaline: 300 hours typical, without backlight 1 Meter drop per IEC 61010-1-2001 Per MIL-PRF-28800 for Class 2 instrument 167.1 mm X 85.1 mm X 46.0 mm (6.58 in X 3.35 in X 1.81 in) 13.0 oz (404 g) Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 No 61010-1-04, UL 61010-1 (2004) and IEC/EN 61010-1 2nd Edition for measurement Category III, 600 V, Pollution Degree 2, EMC EN61326-1 Complies with FCC Part 15, Class B Input Impedance (Nominal) ~3 k < 300 pF Common Mode Rejection Ratio (1 k Unbalanced) > 60 dB at dc, 50 or 60 Hz Open Circuit Test Voltage Full Scale Voltage < 2.7 V dc < 0.7 V dc < 2.7 V dc W 2.000 V dc Short Circuit Current < 350 A < 1.0 mA 2 Fluke Corporation 113 Utility Meter Fluke. Keeping your world up and running.(R) Fluke Corporation PO Box 9090, Everett, WA USA 98206 Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa (31 40) 2 675 200 or Fax (31 40) 2 675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com (c)2008 Fluke Corporation. Specifications subject to change without notice. Printed in U.S.A. 3/2008 3292015 D-EN-N Rev A