154
PHE844
EMI suppressor, class X1, metallized polypropylene
0.1 2.2 µF, 440 VAC/480VAC, +105°C
New, small dimensions
TYPICAL APPLICATIONS CONSTRUCTION
TECHNICAL DATA
For worldwide use as electromagnetic
interference suppressor in all X1 and
across-the-line applications.
Metallized polypropylene winding,
encapsulated in self-extinguishing material
meeting the requirements of UL 94 V0.
ENVIRONMENTAL TEST DATA
Endurance IEC 6038414 1.25 x UR VAC 50 Hz,
once every hour increased
to 1000 VAC for 0.1 s,
1000 h at upper rated temperature
Vibration IEC 6006826 3 directions at 2 hours each, No visible damage
Test Fc 1055 Hz at 0.75 mm or 98 m/s2No open or short circuit
Bump IEC 60068229 1000 bumps at No visible damage
Test Eb 390 m/s2No open or short circuit
Change of temperature IEC 60068214 Upper and lower rated No visible damage
Test Na temperature 5 cycles
Active flammability EN 132400
Passive flammability IEC 60384-14 (1993) Enclosure material of
EN 132400 UL94V0 flammability class
UL1414
Humidity IEC 60068-2-3 +40°C and 56 days
Test Ca 90 95% R.H.
p d std l max l b
22.5 ± 0.4 0.8 6 30 ±0.4
27.5 ± 0.4 0.8 6 30 ±0.4
37.5 ± 0.4 1.0 6 30 ±0.4
Tolerance in lead length
< 30 mm mm
30 mm mm
+0
1
+5
0
L
H
B
pl
d
0.5
b
Rated voltage 440 VAC 50/60 Hz (ENEC)
480 VAC 50/60 Hz (UL, CSA)
Capacitance range 0.1 2.2 µF
Capacitance tolerance ± 20% standard, ± 10% option
Temperature range 40 to +105°C
Climatic category 40/105/56/B
Approvals ENEC, UL, CSA
Dissipation factor Maximum values at +23°C
C 0.1 µF 0.1µF < C 1 µF C > 1 µF
1 kHz 0.1% 0.1% 0.1%
10 kHz 0.2% 0.4% 0.8%
100 kHz 0.6% ––
Test voltage between The 100% screening factory test is carried out at 2700
terminals VDC. The voltage level is selected to meet the
requirements in applicable equipment standards. All
electrical characteristics are checked after the test.
Resonance frequency Tabulated self-resonance frequencies f0 refer to 5 mm
lead length.
Insulation resistance C 0.33 µF: 30 000 M
C > 0.33 µF: 10 000 s
In DC application Recommended voltage:1000VDC
155
ARTICLE TABLE
Quantity per package
Capaci- Max dimensions Max Approvals
tance in mm Tray Weight f0dU/dt Article code
µF B H L p pcs g MHz V/µs
ENEC
UL
CSA
APPROVALS/REFERENCE DOCUMENTS
Certification Body Specification Approval reference
ENEC EN 132400 SE/0140-1
UL UL 1283 (UR=480 VAC) E100117
UL 1414 (UR = 250 VAC) E73869
cUL recognition C 22.2 No. 8 (UR=480 VAC) E100117
(CSA) C 22.2 No. 1 (UR=250 VAC) E73869
ORDERING INFORMATION PACKING
The box dimensions for bulk packaging are
245 x 145 x 80 mm. Quantity/package as
per article table.
Reels with taped capacitors are packed
10 in a box with dimension 370 x 370 x 560
mm. Quantity/reel according to article table.
The standard quantity/reel is for 360 mm
reel. If 500 mm reel is required, it must be
specified when ordering and the quantity is
2 x the given quantity.
MARKING
RIFA
RIFA article code
Rated capacitance
Capacitance tolerance code
Rated voltage
X1
Approval marks
Manufacturing date code
IEC climatic category
Passive flammability class
PHE844
LEAD SPACING 22.5 MM
0.10 8.0 16.0 26.0 22.5 186 3.8 3.2 100 PHE844RD6100MR06L2
0.15 9.0 18.5 26.0 22.5 168 5.0 2.6 100 √√√ PHE844RD6150MR06L2
0.22 11.0 21.5 26.0 22.5 253 6.6 2.1 100 √√√ PHE844RD6220MR06L2
0.33 13.5 23.0 26.0 22.5 209 9.0 1.8 100 √√√ PHE844RD6330MR06L2
0.47 15.5 24.5 26.0 22.5 176 10.0 1.5 100 √√√ PHE844RD6470MR06L2
LEAD SPACING 27.5 MM
0.22 10.5 20.5 31.5 27.5 216 8.0 2.2 100 √√√ PHE844RF6220MR06L2
0.33 13.5 23.0 31.5 27.5 171 10.8 1.7 100 √√√ PHE844RF6330MR06L2
0.47 14.5 24.5 31.5 27.5 153 14.5 1.4 100 √√√ PHE844RF6470MR06L2
0.68 17.5 28.0 31.5 27.5 126 17.0 1.1 100 √√√ PHE844RF6680MR06L2
1.0 21.0 30.0 31.5 27.5 108 22.6 1.0 100 √√√ PHE844RF7100MR06L2
LEAD SPACING 37.5 MM
0.47 13.0 24.0 41.0 37.5 140 14.0 1.3 100 √√√ PHE844RR6470MR06L2
0.68 13.0 24.0 41.0 37.5 140 14.0 1.1 100 √√√ PHE844RR6680MR06L2
1.0 15.0 26.0 41.0 37.5 119 17.0 0.92 100 √√ PHE844RR7100MR06L2
1.5 19.0 36.0 41.0 37.5 91 28.5 0.74 100 √√√ PHE844RR7150MR06L2
2.2 21.0 38.0 41.0 37.5 84 34.4 0.60 100 √√√ PHE844RR7220MR06L2
The article code for the standard part is given in the article table.
For other options, see page 21.