Extract from the online catalog QUINT-PS-100-240AC/24DC/40 Order No.: 2938879 http://eshop.phoenixcontact.co.uk/phoenix/treeViewClick.do?UID=2938879 DIN rail power supply unit 24 V DC/40 A, primary switched-mode, 1phase. Product notes WEEE/RoHS-compliant since: 10/07/2006 Commercial data EAN 4 017918 987091 Pack 1 Customs tariff 85044081 Country of Origin CN Catalog page information Page 563 (IF-2009) Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation at http:// www.download.phoenixcontact.com. The General Terms and Conditions of Use apply to Internet downloads. Product description QUINT POWER power supply units for plant and special engineering reliably start heavy loads with high inrush currents using the POWER BOOST. Thanks to the wide-range input and extensive package of approvals, they can be used in all sectors of industry the world over. The switching output or floating relay contact are used for remote diagnostics. Technical data Input data Nominal input voltage PHOENIX CONTACT Ltd http://www.phoenixcontact.co.uk 110 V AC ... 240 V AC Page 1 / 7 20-Jan-2012 QUINT-PS-100-240AC/24DC/40 Order No.: 2938879 http://eshop.phoenixcontact.co.uk/phoenix/treeViewClick.do?UID=2938879 AC input voltage range 85 V AC ... 264 V AC (Derating < 100 V DC: 2.5%/V) DC input voltage range 90 V DC ... 350 V DC (Derating < 110 V DC: 2.5%/V) AC frequency range 45 Hz ... 65 Hz DC frequency range 0 Hz Current consumption Approx. 12.5 A (120 V AC) Approx. 4.5 A (230 V AC) Nominal power consumption 960 W Inrush surge current < 15 A (typical) Power failure bypass > 20 ms (120 V AC) > 20 ms (230 V AC) Input fuse 20 A (fast blow, internal) Permissible backup fuse B16 B20 Type of protection Transient surge protection Protective circuit/component Varistor Output data Nominal output voltage 24 V DC 1% Setting range of the output voltage 22.5 V DC ... 29.5 V DC (> 24 V constant capacity) Output current 40 A (-25 C ... 60 C) 45 A (with POWER BOOST, -25C ... 40C permanent) Derating 60 C ... 70 C (2.5%/K) Connection in parallel Yes, for redundancy and increased capacity Connection in series Yes Max. capacitive load Unlimited Current limitation Approx. IBOOST = 45 A (for short-circuit) Control deviation < 1 % (change in load, static 10% ... 90%) < 2 % (change in load, dynamic 10% ... 90%) < 0.1 % (change in input voltage 10%) Residual ripple < 30 mVPP (with nominal values) Peak switching voltages nominal load < 50 mVPP (20 MHz) Maximum power dissipation idling 28 W Power loss nominal load max. 80 W General data Width PHOENIX CONTACT Ltd http://www.phoenixcontact.co.uk 240 mm Page 2 / 7 20-Jan-2012 QUINT-PS-100-240AC/24DC/40 Order No.: 2938879 http://eshop.phoenixcontact.co.uk/phoenix/treeViewClick.do?UID=2938879 Height 130 mm Depth 125 mm Width with alternative assembly 122 mm Height with alternative assembly 130 mm 243 mm Net weight 3.5 kg Operating voltage display Green LED Efficiency > 92 % (for 230 V AC and nominal values) Insulation voltage input/output 3 kV AC (type test) 2 kV AC (routine test) Degree of protection IP20 Protection class I, with PE connection MTBF (IEC 61709, SN 29500) > 500000 h Ambient temperature (operation) -25 C ... 70 C (> 60 C derating) Ambient temperature (storage/transport) -40 C ... 85 C Max. permissible relative humidity (operation) 95 % (at 25 C, no condensation) Mounting position horizontal DIN rail NS 35, EN 60715 Assembly instructions Can be aligned: Horizontally 0 mm, vertically 50 mm Electromagnetic compatibility Conformance with EMC Directive 2004/108/EC Noise emission EN 50081-2 Noise immunity EN 61000-6-2:2005 Low Voltage Directive Conformance with LV directive 2006/95/EC Standard - Electrical equipment of machines EN 60204 Standard - Safety of transformers EN 61558-2-17 Standard - Electrical safety EN 60950-1/VDE 0805 (SELV) EN 61558-2-17 Shipbuilding approval Germanischer Lloyd (EMC 2), ABS, DNV Standard - Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV) Standard - Safety extra-low voltage EN 60950-1 (SELV) EN 60204 (PELV) Standard - Safe isolation DIN VDE 0100-410 DIN VDE 0106-1010 Standard - Protection against electric shock PHOENIX CONTACT Ltd http://www.phoenixcontact.co.uk DIN 57100-410 Page 3 / 7 20-Jan-2012 QUINT-PS-100-240AC/24DC/40 Order No.: 2938879 http://eshop.phoenixcontact.co.uk/phoenix/treeViewClick.do?UID=2938879 Standard - Protection against shock currents, basic requirements for protective separation in electrical equipment DIN VDE 0106-101 Standard - Limitation of mains harmonic currents EN 61000-3-2 Standard - Equipment safety GS (tested safety) Certificate CB Scheme UL approvals UL/C-UL listed UL 508 UL/C-UL Recognized UL 60950 UL/C-UL Listed UL 1604 Class I, Division 2, Groups A, B, C, D Surge voltage category III Connection data, input Connection method Screw connection Conductor cross section solid min. 0.2 mm Conductor cross section solid max. 6 mm Conductor cross section stranded min. 0.2 mm Conductor cross section stranded max. 4 mm Conductor cross section AWG/kcmil min. 24 Conductor cross section AWG/kcmil max 10 Stripping length 7 mm Screw thread M3 Connection data, output Connection method Screw connection Conductor cross section solid min. 0.5 mm Conductor cross section solid max. 16 mm Conductor cross section stranded min. 0.5 mm Conductor cross section stranded max. 10 mm Conductor cross section AWG/kcmil min. 20 Conductor cross section AWG/kcmil max 6 Stripping length 10 mm Signaling Output name DC OK active Output description UOUT > 0.9 x UN: High signal Maximum switching voltage 24 V Output voltage + 24 V DC (signal) Maximum inrush current 20 mA (short-circuit resistant) PHOENIX CONTACT Ltd http://www.phoenixcontact.co.uk Page 4 / 7 20-Jan-2012 QUINT-PS-100-240AC/24DC/40 Order No.: 2938879 http://eshop.phoenixcontact.co.uk/phoenix/treeViewClick.do?UID=2938879 Continuous load current 20 mA Status display "DC OK" LED green Note on status display UOUT < 0.9 x UN: LED flashing Conductor cross section solid min. 0.2 mm Conductor cross section solid max. 6 mm Conductor cross section stranded min. 0.2 mm Conductor cross section stranded max. 4 mm Conductor cross section AWG/kcmil min. 24 Conductor cross section AWG/kcmil max 10 Tightening torque, min 0.5 Nm Tightening torque max 0.6 Nm Screw thread M3 Output name DC OK floating Output description Relay contact, UOUT > 0.9 x UN: Contact closed Maximum switching voltage 30 V AC/DC Maximum inrush current 1A Continuous load current 1A Status display "DC OK" LED green Certificates Certification CUL, CUL Listed, DNV, GL, GOST, UL, UL Listed Certification Ex: CUL-EX LIS, UL-EX LIS Accessories Item Designation Description 2853983 UTA 107 Universal DIN rail adapter, for screwing on switchgear 2938235 UWA 182/52 Universal wall adapter General PHOENIX CONTACT Ltd http://www.phoenixcontact.co.uk Page 5 / 7 20-Jan-2012 QUINT-PS-100-240AC/24DC/40 Order No.: 2938879 http://eshop.phoenixcontact.co.uk/phoenix/treeViewClick.do?UID=2938879 Drawings Block diagram Circuit diagram PHOENIX CONTACT Ltd http://www.phoenixcontact.co.uk Page 6 / 7 20-Jan-2012 QUINT-PS-100-240AC/24DC/40 Order No.: 2938879 http://eshop.phoenixcontact.co.uk/phoenix/treeViewClick.do?UID=2938879 Address PHOENIX CONTACT Ltd Halesfield 13 Telford / Shropshire / TF7 4PG,England Phone 01952 681 700 Fax 01952 681 799 http://www.phoenixcontact.co.uk Phoenix Contact Ltd. Technical modifications reserved; PHOENIX CONTACT Ltd http://www.phoenixcontact.co.uk Page 7 / 7 20-Jan-2012