MB3505-BC01
THRU
MB3510-BC01
35 Amp Single Phase
Bridge Rectifier
50 to 1000 Volts
MB-35
Features
Low Reverse Leakage Current
High Conductivity Metal Case
Any Mounting Position
Surge Rating Of 400 Amps
Maximum Ratings
Operating Temperature: -55°C to +150°C
Storage Temperature: -55°C to +150°C
MCC
Catalog
Number
Device
Marking Maximum
Recurrent
Peak Reverse
Voltage
Maximum
RMS
Voltage
Maximum
DC
Blocking
Voltage
MB3505-BC01 MB3505 50V 35V 50V
MB351-BC01 MB351 100V 70V 100V
MB352-BC01 MB352 200V 140V 200V
MB354-BC01 MB354 400V 280V 400V
MB356-BC01 MB356 600V 420V 600V
MB358-BC01 MB358 800V 560V 800V
MB3510-BC01 MB3510 1000V 700V 1000V
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
Current IF(AV) 35.0A TC = 55°C
Peak Forward Surge
Current IFSM
400A 8.3ms, half sine
Maximum Forward
Voltage Drop Per
Element VF 1.2V IFM = 17.5A per
element;
TJ = 25°C
Maximum DC
Reverse Current At
Rated DC Blocking
Voltage
IR 10µA
1mA TJ = 25°C
TJ = 125°C
B
C
E
AC
+
-
A
AC
G
H
A
D
J
www.mccsemi.com



 !"#
$%  !"#
MCC
DIMENSIONS
INCHES MM
DIM MIN MAX MIN MAX NOTE
A 1.115 1.135 28.33 28.83
B .427 .322 7.80 8.20
C .469 .563 11.9 14.3
D .688 .730 17.48 18.50
E .618 .658 15.70 16.71
G .193 --- 4.90 ---
H .618 .658 15.70 16.71
J .530 .570 13.46 14.48
I t Rating for Fusing
(<8.3mS) 664 A S
22 2
I t
MB3505-BC01 thru MB3510-BC01
Instantaneous Reverse Leakage Current - MicroAmperes versus
Percent Of Rated Peak Reverse Voltage - Volts
Average Forward Rectified Current - Amperes versus
Case Temperature - °C
Figure 3
Forward Derating Curve
25 50 100 150 175
0
0
10
20
30
Single Phase, Half Wave
60Hz Resistive or Inductive Load
Amps
°C
75
40
50
60
Instantaneous Forward Current - Amperes versus
Instantaneous Forward Voltage - Volts
Figure 1
Typical Forward Characteristics
Volts
4
6
20
10
Amps
.2 1.2
.4 .6 .8 1.0
.01
.02
.04
.06
.1
.2
.4
.6
1
225°C
40
60
100
1.4
Figure 2
Typical Reverse Characteristics
Volts
.4
.6
2
1
µ
20 120
40 60 80 100
.001
.002
.00
4
.006
.01
.02
.04
.06
.1
.2
4
6
10
140
TJ=25°C
1 100
4
0
100
200
300
8
Figure 4
Peak Forward Surge Current
Peak Forward Surge Current - Amperes versus
Number Of Cycles At 60Hz - Cycles
Amps
Cycles
2
6
10 20 60 80
40
00
400
500
600
www.mccsemi.com