LD (ALD) VDE 1 FORM A SLIM POWER RELAY 20.3 .799 LD RELAYS (ALD) FEATURES 7.0 .276 15.0 .591 mm inch RoHS Directive compatibility information http://www.nais-e.com/ 4. High shock resistance The relay withstands a functional shock resistance of 300m/s2 [approx. 30 G more] 5. High insulation resistance * Creepage distance and clearances between contact and coil: Min. 6 mm .236 inch (In compliance with IEC65) * Surge withstand voltage between contact and coil: 10,000 V 6. UL/CSA, VDE, TUV approved. 1. Slim type: Width 7 mm .276 inch. 20.3(L)x7.0(W)x15.0(H) mm .799(L)x.276(W)x.591(H) inch 2. Perfect for small load switching of home appliances 105 switching operations possible with a 3A 250V AC resistive load. 3. Low operating power Compact size, nominal operating power as low as 200mW. SPECIFICATIONS Contact Characteristics Arrangement Initial contact resistance, max. (By voltage drop 6 V DC 1 A) Contact material 1 Form A Max. operating speed Initial insulation resistance*1 Max. 100 m Nominal switching capacity Max. switching power Rating (resistive load) Max. switching voltage Max. switching current Min. switching capacity#1 (Reference value) Mechanical (at 180 cpm) Expected life 3A 125V AC, Electrical (min.operations) (at 20 cpm) 3A 30V DC (at rated load) 3A 250V AC Between open contacts Between contact and coil Initial surge voltage between contact and coil*3 Operate time*4 (at nominal voltage) Release time (with diode)*4 (at nominal voltage) 100 mA, 5 V DC 5x106 Shock resistance * Specifications will vary with foreign standards certification ratings. *1 Measurement at same location as "Initial breakdown voltage" section. *2 Detection current: 10mA *3 Wave is standard shock voltage of 1.2x50ms according to JEC-212-1981 *4 Excluding contact bounce time. *5 Half-wave pulse of sine wave: 11 ms; detection time: 10 s *6 Half-wave pulse of sine wave: 6 ms *7 Detection time: 10 s *8 Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT * Air conditioner * Refrigerator * Hot water units * Microwave ovens * Fan heaters Destructive Conditions for operation, transport and storage*8 (Not freezing and condensing at low temperature) Unit weight Max. 10ms (at 20C 68F) 5 to 85% R.H. Functional*7 Remarks Max. 10ms (at 20C 68F) Humidity Functional*5 Destructive*6 Vibration resistance #1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. 10,000 V Ambient temp. Temperature rise (at 70C 158F) 105 4,000 Vrms for 1 min. Max. 45C with nominal coil voltage and at 3 A contact carrying current (resistance method) 300 m/s2{approx. 30 G} 1,000 m/s2{approx. 100 G} 10 to 55Hz at double amplitude of 1.5mm 10 to 55Hz at double amplitude of 1.5mm -40C to +70C -40F to +158F 2x105 200 mW TYPICAL APPLICATIONS 750 Vrms for 1 min. Initial*2 breakdown voltage AgNi type 3 A 277 V AC, 3 A 30V DC 831 V A (AC), 90W (DC) 277 V AC, 30 V DC 3A Coil Nominal operating power 20 cpm (at rated load) Min. 1,000 M (at 500 V DC) Approx. 4 g .14 oz ORDERING INFORMATION Ex. A LD 1 12 W Product name Contact arrangement Coil voltage (V DC) Packing style LD 1: 1 Form A 4H: 4.5, 09: 9 , 24: 24 12: 12 05: 5, 18: 18 06: 6, Nil: Tube packing W: Carton packing UL/CSA, TUV, VDE approved type is standard. Note: Tube packing: Tube: 50pcs, Case: 1,000pcs Carton packing: Carton: 100pcs, Case: 500pcs All Rights Reserved (c) COPYRIGHT Matsushita Electric Works, Ltd. LD (ALD) TYPES AND COIL DATA (at 20C 68F) Part No. Nominal voltage, V DC Pick-up voltage, V DC (max.) (Initial) Drop-out voltage, V DC (min.) (Initial) Coil resistance, (10%) ALD14H ALD105 ALD106 ALD109 ALD112 ALD118 ALD124 4.5 5 6 9 12 18 24 3.38 3.75 4.5 6.75 9 13.5 18 0.22 0.25 0.3 0.45 0.6 0.9 1.2 101 125 180 405 720 1,620 2,880 Nominal operating current, mA (10%) 44.4 40.0 33.3 22.2 16.7 11.1 8.3 Nominal operating power, mW 200 Maximum allowable voltage, V DC (at 20C 68F) 5.85 6.5 7.8 11.7 15.6 23.4 31.2 DIMENSIONS mm inch PC board pattern (Bottom view) Max. 7.2 .284 Max. 20.5 .807 (1.05) (.041) Max. 15.3 .602 3.4 0.4 .134 .016 0.4 dia. 016 dia. 1.05 .041 0.2 .008 11.5 .453 11.5 .453 7.0 .276 (1.15) (.045) 4-1.1 dia. 4-.043 dia. 4.7 .185 Tolerance: 0.1 .004 0.2 .008 0.8 .031 Schematic (Bottom view) 1.15 .045 4.7 .185 7.0 .276 COM Dimension: General tolerance Max. 1mm .039 inch: 0.1 .004 1 to 3mm .039 to .118 inch: 0.2 .008 Min. 3mm .118 inch: 0.3 .012 NO COIL REFERENCE DATA 1. Max. switching power 2. Life curve 3. Coil temperature rise Sample: ALD112, 6 pcs. Point measured: inside the coil Contact current: 0 A, 3 A 100 70 50 60 0A 3A AC resistive load DC resistive load 1.0 125V AC resistive load 30 10 0.5 0.4 Temperature rise, C 2.0 Life, x104 Contact current, A 3.0 0.3 20C 50 40 70C 30 20 0.2 10 0 20 30 50 100 0 200 300 1 2 0 3 0 100 Contact current, A Contact voltage, V 125 150 Coil applied voltage, %V 4-(2). Release time (without diode) 4-(3). Release time (with diode) Sample: ALD112, 6 pcs. Sample: ALD112, 6 pcs. Sample: ALD112, 6 pcs. 10 10 8 8 8 6 4 Release time, ms 10 Release time, ms Operate time, ms 4-(1). Operate time 6 4 Max. 6 4 Min. Max. Min. 2 2 2 Max. Min. 0 80 100 120 140 Coil applied voltage, %V 0 80 100 120 140 0 Coil applied voltage, %V All Rights Reserved (c) COPYRIGHT Matsushita Electric Works, Ltd. 80 100 120 140 Coil applied voltage, %V 175 LD (ALD) 250V AC 12V DC 60Hz G NO Change of contact resistance 100 100 90 90 80 70 Pick-up voltage Max. 60 Min. 50 40 30 Drop-out voltage Contact resistance, m Sample: ALD112, 6 pcs. Operating speed: 20 cpm Ambient temperature: room temperature circuit: Change of pick-up and drop-out voltage Ratio against the rated voltage, %V 5-(1). Electrical life test (3 A 250 V AC, resistive load) Max. Min. 20 0 70 60 50 40 30 20 Max. Min. 10 10 COM 80 0 10 0 No. of operations, x104 30V DC G 12V DC NO COM Change of contact resistance 100 100 90 90 80 Pick-up voltage 70 Max. 60 Min. 50 40 Drop-out voltage 30 Contact resistance, m Sample: ALD112, 6 pcs. Operating speed: 20 cpm Ambient temperature: room temperature circuit: Change of pick-up and drop-out voltage Ratio against the rated voltage, %V 5-(2). Electrical life test (3 A 30 V DC, resistive load) Max. Min. 20 80 70 60 50 40 30 Max. 20 Min. 10 10 0 10 0 No. of operations, x104 0 10 No. of operations, 20 x104 For Cautions for Use, see Relay Technical Information All Rights Reserved (c) COPYRIGHT Matsushita Electric Works, Ltd. 0 0 10 No. of operations, x104 20