ULTRAFAST WIDEBAND HIGH-FREQUENCY LOGARITHMIC AMPLIFIERS
MODEL: MLIF SERIES
FFEEAATTUURREESS
70 dB dynamic range at 1 GHz
Improved sensitivity
Rise time up to 1 ns
Fast recovery time
±1.5 dB video flatness over 500 MHz bandwidth
Low output noise for increased accuracy
Improved sensitivity through low noise
figure input stages
OPTIONS
Customized center frequencies and
frequency agility
Dynamic range and operational bandwidth
Custom packaging
Extended environmental limits
Military screening available
MLIF-500/100-70 500 100 -70 to 0 -73 1 5 15 25
MLIF-750/500-65 750 500 -65 to 0 -68 1.5 3 10 15
MLIF-900/100-75 900 100 -70 to +5 -73 1 10 30 45
MLIF-1000/500-60 1000 500 -60 to 0 -63 1 3 10 15
MLIF-1000/500-75 1000 500 -70 to +5 -73 2 10 30 45
MLIF-1500/500-60 1500 500 -60 to 0 -63 1.5 3 10 15
MLIF-1800/200-70 1800 200 -65 to +5 -68 1 10 30 45
CENTER OPERATIONAL DYNAMIC TANGENTIAL VIDEO RISE FALL RECOVERY
MODEL FREQUENCY BANDWIDTH RANGE SENSITIVITY FLATNESS TIME TIME TIME
NUMBER (MHz) (MHz) (dBm) (dBm) (±dB) (ns) (ns) (ns)
ADDITIONAL SPECIFICATIONS
The above models are available in 'A, B, G, K and M' housings.
Linearity measured at center frequency and 25°C is ±1 dB.
Add ±0.5 dB over operating temperature of -40 to +85°C and ±0.5 dB over operating bandwidth.
Slope is 15 mV/dB at center frequency and 25°C.
Slope variations of ±5% will occur over operating temperature of -40 to +85°C.
An additional ±5% variation will occur over operating bandwidth.
Video output is DC coupled and rated into 93 .
DC offset drift over operating temperature of -40 to +85°C is ±50 mV typical.
Input impedance is 50 (VSWR < 1.5:1 typical).
Improved second-harmonic rejection on limited IF out.
Power: +12 VDC at 400 mA typical, -12 VDC at 75 mA typical.
ORDER OPTIONS
For ±15 VDC, add suffix “C”.
For limited IF output at 0 dBm nominal, (VSWR < 2.0:1 typical) add suffix “L”.
Typical part number: MLIF-1000/500-75BCL (for 'B' housing at ±15 VDC with limited IF output).
100 Davids Drive, Hauppauge, NY 11788 • TEL: (631) 439-9220 • FAX: (631) 436-7430 • www.miteq.com
C-17B/7 08-14-07
NOTE: FOR MODIFICATION OF OUR STANDARD MODELS, PLEASE CONSULT FACTORY.
MLIF SERIES TYPICAL TEST DATA
LOG LINEARITY
(MLIF-1000/500-70)
PULSE RESPONSE
(MLIF-1000/300-60)
OUTLINE A
MLIF SERIES OUTLINE DRAWINGS
100 Davids Drive, Hauppauge, NY 11788 • TEL: (631) 439-9220 • FAX: (631) 436-7430 • www.miteq.com
C-17B/8 08-14-07
NOTE: DIMENSIONS SHOWN IN BRACKETS [ ] ARE IN MILLIMETERS.
MLIF SERIES OUTLINE DRAWINGS
OUTLINE B
OUTLINE G*
100 Davids Drive, Hauppauge, NY 11788 • TEL: (631) 439-9220 • FAX: (631) 436-7430 • www.miteq.com
C-17B/9 08-14-07
NOTE: DIMENSIONS SHOWN IN BRACKETS [ ] ARE IN MILLIMETERS.
*ABOVE DRAWING INCLUDES LIMITED IF OUTPUT (OPTIONAL).
MLIF SERIES OUTLINE DRAWINGS
OUTLINE K*
OUTLINE M
100 Davids Drive, Hauppauge, NY 11788 • TEL: (631) 439-9220 • FAX: (631) 436-7430 • www.miteq.com
C-17B/10 08-14-07
NOTE: DIMENSIONS SHOWN IN BRACKETS [ ] ARE IN MILLIMETERS.
*ABOVE DRAWING INCLUDES LIMITED IF OUTPUT (OPTIONAL).