ULTRAFAST WIDEBAND HIGH-FREQUENCY LOGARITHMIC AMPLIFIERS MODEL: MLIF SERIES FEATURES * * * * * * * 70 dB dynamic range at 1 GHz Improved sensitivity Rise time up to 1 ns Fast recovery time 1.5 dB video flatness over 500 MHz bandwidth Low output noise for increased accuracy Improved sensitivity through low noise figure input stages OPTIONS * Customized center frequencies and frequency agility * Dynamic range and operational bandwidth * Custom packaging * Extended environmental limits * Military screening available MODEL NUMBER MLIF-500/100-70 MLIF-750/500-65 MLIF-900/100-75 MLIF-1000/500-60 MLIF-1000/500-75 MLIF-1500/500-60 MLIF-1800/200-70 CENTER FREQUENCY (MHz) OPERATIONAL BANDWIDTH (MHz) 500 750 900 1000 1000 1500 1800 100 500 100 500 500 500 200 DYNAMIC RANGE (dBm) -70 -65 -70 -60 -70 -60 -65 to to to to to to to 0 0 +5 0 +5 0 +5 TANGENTIAL SENSITIVITY (dBm) VIDEO FLATNESS (dB) RISE TIME (ns) FALL TIME (ns) RECOVERY TIME (ns) -73 -68 -73 -63 -73 -63 -68 1 1.5 1 1 2 1.5 1 5 3 10 3 10 3 10 15 10 30 10 30 10 30 25 15 45 15 45 15 45 ADDITIONAL SPECIFICATIONS The above models are available in 'A, B, G, K and M' housings. Linearity measured at center frequency and 25C is 1 dB. Add 0.5 dB over operating temperature of -40 to +85C and 0.5 dB over operating bandwidth. Slope is 15 mV/dB at center frequency and 25C. Slope variations of 5% will occur over operating temperature of -40 to +85C. An additional 5% variation will occur over operating bandwidth. Video output is DC coupled and rated into 93 . DC offset drift over operating temperature of -40 to +85C is 50 mV typical. Input impedance is 50 (VSWR < 1.5:1 typical). Improved second-harmonic rejection on limited IF out. Power: +12 VDC at 400 mA typical, -12 VDC at 75 mA typical. ORDER OPTIONS For 15 VDC, add suffix "C". For limited IF output at 0 dBm nominal, (VSWR < 2.0:1 typical) add suffix "L". Typical part number: MLIF-1000/500-75BCL (for 'B' housing at 15 VDC with limited IF output). NOTE: FOR MODIFICATION OF OUR STANDARD MODELS, PLEASE CONSULT FACTORY. 100 Davids Drive, Hauppauge, NY 11788 * TEL: (631) 439-9220 * FAX: (631) 436-7430 * www.miteq.com C-17B/7 08-14-07 MLIF SERIES TYPICAL TEST DATA LOG LINEARITY (MLIF-1000/500-70) PULSE RESPONSE (MLIF-1000/300-60) MLIF SERIES OUTLINE DRAWINGS OUTLINE A NOTE: DIMENSIONS SHOWN IN BRACKETS [ ] ARE IN MILLIMETERS. 100 Davids Drive, Hauppauge, NY 11788 * TEL: (631) 439-9220 * FAX: (631) 436-7430 * www.miteq.com C-17B/8 08-14-07 MLIF SERIES OUTLINE DRAWINGS OUTLINE B OUTLINE G* NOTE: DIMENSIONS SHOWN IN BRACKETS [ ] ARE IN MILLIMETERS. * ABOVE DRAWING INCLUDES LIMITED IF OUTPUT (OPTIONAL). 100 Davids Drive, Hauppauge, NY 11788 * TEL: (631) 439-9220 * FAX: (631) 436-7430 * www.miteq.com C-17B/9 08-14-07 MLIF SERIES OUTLINE DRAWINGS OUTLINE K* OUTLINE M NOTE: DIMENSIONS SHOWN IN BRACKETS [ ] ARE IN MILLIMETERS. * ABOVE DRAWING INCLUDES LIMITED IF OUTPUT (OPTIONAL). 100 Davids Drive, Hauppauge, NY 11788 * TEL: (631) 439-9220 * FAX: (631) 436-7430 * www.miteq.com C-17B/10 08-14-07