LZ (ALZ)
1
ds_61B15_en_lz: 170912D
ORDERING INFORMATION
Low profile: 15.7mm height
1a/1c 16 A power relay LZ RELAYS
FEATURES
1. Low profile type with height of
15.7 mm
Slim, low profile type with dimensions of
28.8 (L) 12.5 (W) 15.7 (H) mm
1.134 (L) .492 (W) .618 (H) inch.
2. High insulation resistance
Superior insulation characteristics have
been achieved by maintaining an
insulation distance between coil and
contacts of at least 10 mm for both
creepage distance and clearances.
Furthermore, anti-surge voltage is 10 kV
and higher. (Supports European
reinforced insulation requirement.)
3. Superior heat resistance
Can be used in ambient temperatures up
to 85C 185F for the class B and 105C
221F for the class F.
4. Low operating power
Power saved with a nominal operating
power of only 400 mW.
5. Conforms to the various safety
standards:
UL, C-UL, VDE approved.
6. Superior heat resistance and
tracking resistance
EN60335-1 GWT compliant (Tested by
VDE) type available.
TYPICAL APPLICATIONS
1) Household electrical appliances
TV, CATV, Audio equipment, Microwave
ovens, and Heaters, etc.
2) Office equipment
Copy machines, Packaged air
conditioners, and Vending machines
3) Industrial equipment
Machine tools, Robots, and Temperature
controllers
Packing style
Nil: Tube packing
W: Carton packing
LZ relays
ALZ
Coil voltage (DC)
05: 5 V 18: 18 V
09: 9 V 24: 24 V
12: 12 V 48: 48 V
Coil insulation class
B: Class B insulation
F: Class F insulation
Flame resistance and tracking resistance
Nil:
T: EN60335-1 (Conform)
Protective construction
1: Flux-resistant type
2: Sealed type
Contact arrangement
1: 1 Form C
5: 1 Form A
Note: UL, C-UL, VDE approved type is standard.
(not for new designs)
LZ (ALZ)
2ds_61B15_en_lz: 170912D
TYPES
1. Flux-resistant type
2. Sealed type
Notes: 1. If you desire tube packaging, please order without adding the packaging symbol “W” to the end of the part number.
2. Carton packing symbol “W” is not marked on the relay.
3. EN60335-1 GWT compliant types available. When ordering, please add suffix “T”.
Ex. ALZ51B12T
, ALZ51F12TW
RATING
1. Coil data
Contact arrangement Coil voltage Flux-resistant type Packing style
Class B insulation Class F insulation Tube packing Carton packing
Part No. Part No. Inner carton Case Inner carton Case
1 Form C
5 V DC ALZ11B05W ALZ11F05W
20 pcs. 800 pcs. 100 pcs. 500 pcs.
9 V DC ALZ11B09W ALZ11F09W
12 V DC ALZ11B12W ALZ11F12W
18 V DC ALZ11B18W ALZ11F18W
24 V DC ALZ11B24W ALZ11F24W
48 V DC ALZ11B48W ALZ11F48W
1 Form A
(New PC board terminal)
5 V DC ALZ51B05W ALZ51F05W
9 V DC ALZ51B09W ALZ51F09W
12 V DC ALZ51B12W ALZ51F12W
18 V DC ALZ51B18W ALZ51F18W
24 V DC ALZ51B24W ALZ51F24W
48 V DC ALZ51B48W ALZ51F48W
Contact arrangement Coil voltage Sealed type Packing style
Class B insulation Class F insulation Tube packing Carton packing
Part No. Part No. Inner carton Case Inner carton Case
1 Form C
5 V DC ALZ12B05W ALZ12F05W
20 pcs. 800 pcs. 100 pcs. 500 pcs.
9 V DC ALZ12B09W ALZ12F09W
12 V DC ALZ12B12W ALZ12F12W
18 V DC ALZ12B18W ALZ12F18W
24 V DC ALZ12B24W ALZ12F24W
48 V DC ALZ12B48W ALZ12F48W
1 Form A
(New PC board terminal)
5 V DC ALZ52B05W ALZ52F05W
9 V DC ALZ52B09W ALZ52F09W
12 V DC ALZ52B12W ALZ52F12W
18 V DC ALZ52B18W ALZ52F18W
24 V DC ALZ52B24W ALZ52F24W
48 V DC ALZ52B48W ALZ52F48W
Nominal coil
voltage Pick-up voltage
(at 20°C 68F) Drop-out voltage
(at 20°C 68F) Nominal operating
current
[10%] (at 20°C 68F) Coil resistance
[10%] (at 20°C 68F) Nominal operating
power
(at 20°C 68F) Max. applied voltage
(at 20°C 68F)
5 V DC
Max. 70%V
nominal voltage
(Initial)
Min. 10%V
nominal voltage
(Initial)
80 mA 63
400 mW 130%V of
nominal voltage
9 V DC 44.4 mA 203
12 V DC 33.3 mA 360
18 V DC 22.2 mA 810
24 V DC 16.7 mA 1,440
48 V DC 8.3 mA 5,760
LZ (ALZ)
3
ds_61B15_en_lz: 170912D
2. Specifications
REFERENCE DATA
Characteristics Item Specifications
Contact Arrangement 1 Form C, 1 Form A
Contact resistance (Initial) Max. 100 m(By voltage drop 6V DC 1A)
Contact material AgSnO2 type
Rating
Nominal switching capacity (resistive load) 16A 250V AC
Max. switching power (resistive load) 4,000V A
Max. switching voltage 440V AC
Max. switching current 16A
Nominal operating power 400mW
Min. switching capacity*1
*1 This value can change due to the switching frequency , environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.
100mA 5V DC
Electrical
characteristics
Insulation resistance (Initial) Min. 1,000M (at 500V DC)
Breakdown voltage
(Initial)
Between open contacts 1,000 Vrms for 1min. (Detection current: 10mA)
Between contact and
coil 5,000 Vrms for 1min. (Detection current: 10mA)
Temperature rise (at 20C 68F)Max. 55C 131F
[with nominal coil voltage and at 16A contact carrying current (resistance method) at 20°C 68F]
Surge breakdown voltage*2
(Between contacts and coil)
*2 Wave is standard shock voltage of 1.2 50s according to JEC-212-1981
10,000 V (Initial)
Operate time (at nominal voltage) (at 20C 68F) Max. 15ms (excluding contact bounce time)
Release time (at nominal voltage) (at 20C 68F) Max. 5ms (excluding contact bounce time, without diode)
Mechanical
characteristics
Shock resistance Functional Min. 100 m/s2 {10G} (Half-wave pulse of sine wave: 11ms; detection time: 10s.)
Destructive Min. 1,000 m/s2 {100G} (Half-wave pulse of sine wave: 6ms.)
Vibration resistance Functional 10 to 55 Hz at double amplitude of 1.5mm (Detection time: 10s.)
(Only the N.C. side of 1 Form C is 0.8mm)
Destructive 10 to 55 Hz at double amplitude of 1.5mm
Expected life Mechanical (at 180 times/min.) Min. 107
Electrical (at 20 times/min.)*3
*3 In order to obtain the full rated life cycles, the relay should be properly vented by removing the vent nib. For details, please refer to NOTES.
N.O.: Min. 105, N.C.: Min. 5104
Conditions
Conditions for operation, transport and storage
*4
,
*5
*4 Class F type is ambient temperature 105°C +221F.
*5 The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to “6. Usage, Storage and Transport
Conditions” in AMBIENT ENVIRONMENT (page 626).
* Please note that some of the specifications listed above may not comply with overseas standards.
Ambient temperature: –40C to +85C –40F to +185F (Class B)
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. operating speed 20 times/min. (at nominal switching capacity)
Unit weight Approx. 12 g .42 oz
1. Max. switching power (AC resistive load) 2. Max. switching power (DC resistive load) 3. Coil temperature rise
Sample: ALZ1 1F12, 5pcs.
Measured portion: coil inside
Contact current: 0 A, 16 A
101 30 1000
1
10
16
100
100 440
Contact voltage, V
Contact current, A
100
1
10
100
100
Contact current, A
Contact voltage, V
1000 120 125110 115105 130 135
30
25
35
40
50
45
55
20
Normal
temperature
Normal
temperature
16A
0A
85°C
105°C
85°C
105°C
Temperature rise, °C
Coil applied voltage, %V
LZ (ALZ)
4ds_61B15_en_lz: 170912D
DIMENSIONS (mm inch)
SAFETY STANDARDS
* CSA standard: Certified by C-UL
UL/C-UL (Recognized) VDE (Certified) TV rating (UL/CSA)
File No. Contact rating File No. Contact rating File No. Rating
E43149 16A 277V AC, 34.8LRA/7.2FLA/120V AC, 15LRA/3FLA/120V AC
10LRA/3FLA 240V AC, 20A 240V AC (N.O. only)
16A 30V DC, 25A 240V AC, 15A 240V AC Resistive load 105C (N.O. only)
40000380 16A 250V AC (cos=1.0) C-UL
E43149 TV-5
Download from our Web site.
CAD Data
1. 1 Form A type
CAD Data
Dimension: Tolerance
Less than 1 mm.039inch:0.1.004
Min. 1 mm.039inch less than 3 mm.118inch:0.2.008
Min. 3 mm.118inch:0.3.012
28.8
5
0.50.5
202.5
15.7
3.5
0.5
12.5
7.5
0.8
1.134
.197
.020.020
.787.098
.618
.138
.020
.492
.295
.031
PC board pattern
Tolerance: 0.1 .004
Schematic (Bottom view)
20
7.5
5
6-1.3 dia.
.787
.295
.197
6-.051 dia.
Coil
2. 1 Form C type
CAD Data
Dimension: Tolerance
Less than 1 mm.039inch:0.1.004
Min. 1 mm.039inch less than 3 mm.118inch:0.2.008
Min. 3 mm.118inch:0.3.012
28.8
5 5
12.5
7.5
15.7
3.5
0.5 0.8
0.5
0.5
202.5
1.134
.197.197
.492
.295
.618
.138
.020 .031
.020
.020
.787.098
PC board pattern
Tolerance: 0.1 .004
Schematic (Bottom view)
20
7.5
55
8-1.3 dia.
.787
.295
.197.197
8-.051 dia.
Coil
LZ (ALZ)
5
ds_61B15_en_lz: 170912D
NOTES
For Cautions for Use, see Relay Technical Information (page 610).
Electrical life (Sealed type)
In order to obtain the full rated life cycles,
the relay should be properly vented by
removing the vent nib after the soldering/
washing process.
Vent nib
For Cautions for Use, see Relay Technical Information.