IWS DC-DC Series Data Sheet Single-Output, 10 Watts Features * * * * * * * * Description IWS DC-DC converters offer excellent regulation and isolation in an industry-standard package. Available in several input versions, the IWS is perfect for industrial, datacom, or telecom applications. The IWS features short-circuit protection and 500 VDC isolation. Please see the IWD series for dual-output applications. Industry-standard package Industry-standard pinout 85C case operation Short-circuit protection 5, 12, 24, and 48V input versions Input Pi filter and 6-sided shielding Regulated outputs 500V isolation Efficiency vs. Load (5V Input) 90 EFFICIENCY % 85 Technical Specifications Input 80 IWS515 IWS548 75 Voltage Range 5 VDC Nominal 4.5 - 9 VDC 12 VDC Nominal 9 - 18 VDC 24 VDC Nominal 18 - 36 VDC 48 VDC Nominal 70 10 20 30 40 50 60 70 80 90 100 LOAD % 36 - 72 VDC Reflected Ripple 20% Iin Max. Reverse Input Current 100% Iin Max. Efficiency vs. Load (12V Input) 90 85 80 Setpoint accuracy EFFICIENCY % Output 1% Line regulation Vin Min. - Vin Max., Iout Rated 0.5% Vout Load regulation Iout Min. - Iout Max., Vin Nom. 1.0% Vout Minimum output current 25% Iout Pk deviation 1% Vout Settling time 500 s Temperature coefficient -1205 70 -1212 65 -1215 10 % Iout Rated Dynamic regulation, loadstep 75 60 55 50 10 20 30 40 50 0.02%/C Ripple and noise, 20 MHz BW Short-circuit protection 1 70 80 90 100 1% Vout Nom. General Continuous Current Limit 60 LOAD % 130% Switching Frequency 300 kHz Isolation Notes 1 Continuous short-circuit protection is provided. Long-term continuous operation in this mode is not recommended. Converter will auto-restart once fault has been removed. 500 VDC Input - Case 500 VDC Output - Case 500 VDC Isolation Resistance - Input to Output Standard Case Operating Range Specifications typically at 25C, normal line, and full load, unless otherwise stated. Soldering Conditions: I/O pins, 260C, ten seconds; fully compatible with commercial wave-soldering equipment. Input - Output Industrial Range (add -I to p/n) Storage Range Humidity Max., Non-Condensing Vibration, 3 Axes, 5 Min Each Safety: Agency approvals may vary from model to model. Please consult factory for specific model information. Safety Weight (approx.) REV. NOV 18, 2003 Page 1 of 3 109 Ohms -25 to +85C -40 to +85C -40 to +125C 95% 5 g, 10 - 55 Hz UL, cUL, TUV 1.4 oz IWS DC-DC Series Data Sheet Single-Output, 10 Watts Model Selection MODEL INPUT VOLTAGE (VOLTS) INPUT VOLTAGE RANGE (VOLTS) MAXIMUM INPUT CURRENT (AMPS)* OUTPUT VOLTAGE (VOLTS) RATED OUTPUT CURRENT (AMPS) 5 5 5 5 5 12 12 12 12 24 24 24 24 48 48 48 48 48 48 48 4.5 - 9 4.5 - 9 4.5 - 9 4.5 - 9 4.5 - 9 9 - 18 9 - 18 9 - 18 9 - 18 18 - 36 18 - 36 18 - 36 18 - 36 36 - 72 36 - 72 36 - 72 36 - 72 36 - 72 36 - 72 36 - 72 3.20 3.70 3.45 3.60 3.55 1.80 1.65 1.75 1.75 0.88 1.00 0.95 0.90 0.85 0.94 0.85 0.96 1.00 0.45 0.45 5 12 15 24 48 12 15 24 48 5 15 24 48 2.1 3.3 5 12 15 24 48 2.00 1.00 0.75 0.50 0.25 1.00 0.75 0.50 0.25 2.00 0.80 0.50 0.25 3.80 3.00 2.00 1.00 0.80 0.50 0.25 IWS505 IWS512 IWS515 IWS524 IWS548 IWS1212 IWS1215 IWS1224 IWS1248 IWS2405 IWS2415I IWS2424 IWS2448 IWS4802.1 IWS4803.3 IWS4805 IWS4812 IWS4815 IWS4824 IWS4848 NOTES: RIPPLE & NOISE pk-pk (mV) TYPICAL EFFICIENCY** 100 120 150 240 480 120 150 240 480 100 150 240 480 75 100 100 120 150 240 480 78% 80% 82% 83% 84% 82% 84% 85% 86% 78% 82% 85% 86% 67% 73% 80% 84% 82% 85% 89% * Maximum input current at minimum input voltage, maximum rated output power. ** At nominal Vin, rated output. Mechanical Drawing Thermal Impedance Natural Convection 100 LFM 200 LFM 300 LFM 400 LFM 15.4 C/W 12.2 C/W 9.3 C/W 7.4 C/W 6.4 C/W Pin Function 1 +Vin 2 3 -Vin + Vout 4 - Vout Note: Thermal impedance data is dependent on many environmental factors. The exact thermal performance should be validated for specific application. Tolerances Inches: .XX 0.040 .XXX 0.010 (Millimeters) .X 1.0 .XX 0.25 Pin: 0.002 0.05 Case: +0.04, -0.00 +1.0, -0.0 (Dimensions as listed unless otherwise specified.) REV. NOV 18, 2003 Page 2 of 3 OPTIONS This page is offered as a reference. Consult factory for actual availability of options. When ordering equipment options, use the following suffix information. Select preferred option(s) and add the suffix to the model number. Ordering option examples are located below the options table. OPTION SUFFIX APPLICABLE SERIES Negative Logic N HAS, HBD, HBS, HES, HLS, HLD, LES, QBS, QES, QLS, TES, TQD Lucent-Compatible Trim T HAS, HBD, HBS, HES, HLS, QBS, QES, QLS Trim 1 IAS, LES Enable 2 IAD, IAS, LES, SMS Trim and Enable 3 IAS, LES Pin Length and Heat Sink Options REMARKS TTL "Low" Turns Module ON TTL "High" Turns Module OFF Standard Pin Length is 0.180" (4.6mm) 0.110" (2.8mm) Pin Length 8 All Leaded Models 0.150" (3.8mm) Pin Length 9 All Leaded Models 0.24" (6.1mm) Horizontal Heat Sink 1H All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks (Except HLS, HLD, QLS, TLD, and TKD Packages) Includes Thermal Pad 0.24" (6.1mm) Vertical Heat Sink 1V All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks (Except HLS, HLD, QLS, TLD, and TKD Packages) Includes Thermal Pad 0.45" (11.4mm) Horizontal Heat Sink 2H All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks (Except HLS, HLD, QLS, TLD, and TKD Packages) Includes Thermal Pad 0.45" (11.4mm) Vertical Heat Sink 2V All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks (Except HLS, HLD, QLS, TLD, and TKD Packages) Includes Thermal Pad 0.95" (24.1mm) Horizontal Heat Sink 3H All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks (Except HLS, HLD, QLS, TLD, and TKD Packages) Includes Thermal Pad 0.95" (24.1mm) Vertical Heat Sink 3V All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks (Except HLS, HLD, QLS, TLD, and TKD Packages) Includes Thermal Pad Example Options: HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent-compatible trim, and 0.95" vertical heat sink. LES015YJ-3N = LES015YJ with optional trim and enable, negative logic. QBS066ZG-AT8 = QBS066ZG-A with Lucent-compatible trim and 0.110" pin length. NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. REV. NOV 18, 2003 Page 3 of 3