REV. NOV 18, 2003
50
55
60
65
70
75
80
85
90
10 20 30 40 50 60 70 80 90 100
LOAD %
EFFICIENCY %
-1205
-1212
-1215
70
75
80
85
90
10 20 30 40 50 60 70 80 90 100
LOAD %
EFFICIENCY %
IWS515
IWS548
Technical Specifications
Voltage Range
5 VDC Nominal 4.5 - 9 VDC
12 VDC Nominal 9 - 18 VDC
24 VDC Nominal 18 - 36 VDC
48 VDC Nominal 36 - 72 VDC
Reflected Ripple 20% Iin Max.
Reverse Input Current 100% Iin Max.
IWS DC-DC converters offer excellent regulation and
isolation in an industry-standard package. Available in
several input versions, the IWS is perfect for industrial,
datacom, or telecom applications. The IWS features
short-circuit protection and 500 VDC isolation. Please
see the IWD series for dual-output applications.
Industry-standard package
• Industry-standard pinout
85°C case operation
Short-circuit protection
5, 12, 24, and 48V input versions
Input Pi filter and 6-sided shielding
Regulated outputs
500V isolation
Setpoint accuracy ±1%
Line regulation Vin Min. - Vin Max., Iout Rated ±0.5% Vout
Load regulation Iout Min. - Iout Max., Vin Nom. ±1.0% Vout
Minimum output current 10 % Iout Rated
Dynamic regulation, loadstep 25% Iout
Pk deviation 1% Vout
Settling time 500 µs
Temperature coefficient 0.02%/°C
Ripple and noise, 20 MHz BW 1% Vout Nom.
Short-circuit protection 1 Continuous
Current Limit 130%
Output
General
Description
Features
Efficiency vs. Load (12V Input)
Efficiency vs. Load (5V Input)
1Continuous short-circuit protection is provided. Long-term continuous
operation in this mode is not recommended. Converter will auto-restart
once fault has been removed.
Specifications typically at 25°C, normal line, and full load, unless
otherwise stated.
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with
commercial wave-soldering equipment.
Safety: Agency approvals may vary from model to model. Please
consult factory for specific model information.
Notes
Input
Switching Frequency 300 kHz
Isolation
Input - Output 500 VDC
Input - Case 500 VDC
Output - Case 500 VDC
Isolation Resistance - Input to Output 109 Ohms
Standard Case Operating Range -25 to +85°C
Industrial Range (add -I to p/n) -40 to +85°C
Storage Range -40 to +125°C
Humidity Max., Non-Condensing 95%
Vibration, 3 Axes, 5 Min Each 5 g, 10 - 55 Hz
Safety UL, cUL, TUV
Weight (approx.) 1.4 oz
Page 1 of 3
IWS DC-DC Series Data Sheet
Single-Output, 10 Watts
MODEL INPUT VOLTAGE INPUT VOLTAGE MAXIMUM INPUT OUTPUT RATED OUTPUT RIPPLE & NOISE TYPICAL
(VOLTS) RANGE (VOLTS) CURRENT (AMPS)* VOLTAGE (VOLTS) CURRENT (AMPS) pk-pk (mV) EFFICIENCY**
IWS505 5 4.5 - 9 3.20 5 2.00 100 78%
IWS512 5 4.5 - 9 3.70 12 1.00 120 80%
IWS515 5 4.5 - 9 3.45 15 0.75 150 82%
IWS524 5 4.5 - 9 3.60 24 0.50 240 83%
IWS548 5 4.5 - 9 3.55 48 0.25 480 84%
IWS1212 12 9 - 18 1.80 12 1.00 120 82%
IWS1215 12 9 - 18 1.65 15 0.75 150 84%
IWS1224 12 9 - 18 1.75 24 0.50 240 85%
IWS1248 12 9 - 18 1.75 48 0.25 480 86%
IWS2405 24 18 - 36 0.88 5 2.00 100 78%
IWS2415I 24 18 - 36 1.00 15 0.80 150 82%
IWS2424 24 18 - 36 0.95 24 0.50 240 85%
IWS2448 24 18 - 36 0.90 48 0.25 480 86%
IWS4802.1 48 36 - 72 0.85 2.1 3.80 75 67%
IWS4803.3 48 36 - 72 0.94 3.3 3.00 100 73%
IWS4805 48 36 - 72 0.85 5 2.00 100 80%
IWS4812 48 36 - 72 0.96 12 1.00 120 84%
IWS4815 48 36 - 72 1.00 15 0.80 150 82%
IWS4824 48 36 - 72 0.45 24 0.50 240 85%
IWS4848 48 36 - 72 0.45 48 0.25 480 89%
NOTES: * Maximum input current at minimum input voltage, maximum rated output power.
** At nominal Vin, rated output.
REV. NOV 18, 2003
Tolerances
Inches: (Millimeters)
.XX ± 0.040 .X ± 1.0
.XXX ± 0.010 .XX ± 0.25
Pin:
± 0.002 ± 0.05
Case:
+0.04, -0.00 +1.0, -0.0
(Dimensions as listed unless otherwise
specified.)
Thermal Impedance
N
atural Convection 15.4 °C/W
100 LFM 12.2 °C/W
200 LFM 9.3 °C/W
300 LFM 7.4 °C/W
400 LFM 6.4 °C/W
Note:
Thermal impedance data is dependent
on many environmental factors. The
exact thermal performance should be
validated for specific application.
Pin Function
1+V
in
2-V
in
3+ V
out
4- V
out








 
 



 








Model Selection
Page 2 of 3
IWS DC-DC Series Data Sheet
Single-Output, 10 Watts
Mechanical Drawing
Page 3 of 3
REV. NOV 18, 2003
OPTIONS
This page is offered as a reference. Consult factory for actual availability of options. When ordering
equipment options, use the following suffix information. Select preferred option(s) and add the suffix to the
model number. Ordering option examples are located below the options table.
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not authorized for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president
of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
OPTION SUFFIX APPLICABLE SERIES REMARKS
Negative Logic N HAS, HBD, HBS, HES, HLS, HLD, LES, TTL "Low" Turns Module ON
QBS, QES, QLS, TES, TQD TTL "High" Turns Module OFF
Lucent-Compatible Trim T HAS, HBD, HBS, HES, HLS, QBS, QES,
QLS
Trim 1 IAS, LES
Enable 2 IAD, IAS, LES, SMS
Trim and Enable 3 IAS, LES
Pin Length and Heat Sink Options Standard Pin Length is 0.180" (4.6mm)
0.110" (2.8mm) Pin Length 8 All Leaded Models
0.150" (3.8mm) Pin Length 9 All Leaded Models
0.24" (6.1mm) Horizontal Heat Sink 1H All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks Includes Thermal Pad
(Except HLS, HLD, QLS, TLD, and TKD Packages)
0.24" (6.1mm) Vertical Heat Sink 1V All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks Includes Thermal Pad
(Except HLS, HLD, QLS, TLD, and TKD Packages)
0.45" (11.4mm) Horizontal Heat Sink 2H All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks Includes Thermal Pad
(Except HLS, HLD, QLS, TLD, and TKD Packages)
0.45" (11.4mm) Vertical Heat Sink 2V All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks Includes Thermal Pad
(Except HLS, HLD, QLS, TLD, and TKD Packages)
0.95" (24.1mm) Horizontal Heat Sink 3H All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks Includes Thermal Pad
(Except HLS, HLD, QLS, TLD, and TKD Packages)
0.95" (24.1mm) Vertical Heat Sink 3V All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks Includes Thermal Pad
(Except HLS, HLD, QLS, TLD, and TKD Packages)
Example Options:
HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent-compatible trim, and 0.95” vertical heat sink.
LES015YJ-3N = LES015YJ with optional trim and enable, negative logic.
QBS066ZG-AT8 = QBS066ZG-A with Lucent-compatible trim and 0.110” pin length.