DATA SHEET AAT4616A: High Precision Adjustable Current Limited Load Switch with Fault Flag Applications Description * USB ports The AAT4616A SmartSwitch is a current-limiting P-channel MOSFET power switch designed for high side load switching applications. This switch operates with inputs ranging from 2.4 V to 5.5 V, making it ideal for both 3 V and 5 V systems. An integrated current-limiting circuit protects the input supply against large currents that may cause the supply to fall out of regulation. Reverse current blocking is provided to protect the load switch from reverse current potentials while the device is shutdown. * Portable products * Hot-swap supplies * Notebook computers * Proprietary peripheral ports Features * Input voltage: 2.4 V to 5.5 V * Programmable over-current limit setting: 300 mA to 1.6 A * 10% current limit precision at 750 mA * Fast transient response: 2 s response to short circuit * Low quiescent current - 10 A typical while enabled - 1 A maximum with switch off * 130 m typical RDS(ON) * Under-Voltage Lockout (UVLO) The AAT4616A is also protected from thermal overload which is limited by power dissipation and junction temperatures. The current limit threshold is programmed with a resistor from SET to ground and may be adjusted for levels up to 1.6 A. The ultra-fast current limit response to a sudden short circuit is a mere 2 s, which reduces the requirements of local supply bypassing. An open drain FAULT flag signals an over-current or overtemperature condition after a 4 ms blanking time to prevent false reporting. Quiescent current is as low as 10 A and the supply current decreases to less than 1 A in shutdown mode. The AAT4616A is offered in a small Thin, Dual Flat No-Lead (TDFN22-6) package. A typical application circuit is shown in Figure 1. The pin configuration is shown in Figure 2. Signal pin assignments and functional pin descriptions are provided in Table 1. * Reverse blocking during disable * 4 ms fault blanking * Fault flag open-drain output * Active high/low enable options * Over-temperature protection * Temperature range: -40 C to +85 C * TDFN (6-pin, 2 x 2 mm) package (MSL1, 260 C per JEDEC-J-STD-020) Figure 1. AAT4616A Typical Application Circuit Skyworks Solutions, Inc. * Phone [781] 376-3000 * Fax [781] 376-3100 * sales@skyworksinc.com * www.skyworksinc.com 201941E * Skyworks Proprietary Information * Products and Product Information are Subject to Change Without Notice * September 12, 2013 1 DATA SHEET * AAT4616A HIGH PRECISION ADJUSTABLE CURRENT LIMITED LOAD SWITCH WITH FAULT FLAG Figure 2. AAT4616A TDFN22-6 (Top View) Table 1. AAT4616A Signal Descriptions Pin # Name Description 1 OUT Current limiting load switch output (high side P-channel MOSFET drain). Connect a 0.47 F capacitor from OUT to GND for best load transient response. 2 SET Current limit set pin. Connect a resistor between this pin and ground to program the desired current limit set point. 3 FLT Current limit fault flag pin, open-drain output, active low signal. Pull up with a 10 k to 100 k resistor. 4 ON/ON Load switch enable input. Active high and active low options are available. 5 GND Ground 6 IN Load switch power supply input pin (high side P-channel MOSFET source). Bypass with a 1 F capacitor from IN to GND. Table 2. AAT4616A Absolute Maximum Ratings (Note 1) Maximum Units IN to GND Parameter VIN Symbol Minimum -0.3 Typical +6.0 V ON/ON,FLT to GND VON, VFLT -0.3 VIN + 0.3 V SET, OUT to GND VSET, VOUT -0.3 VIN + 0.3 V Maximum DC output current (Note 2) IMAX 2 A Operating junction temperature range TJ -40 +150 C Storage temperature range TSTG -40 +150 C Maximum Soldering Temperature (at leads) TLEAD 300 C Thermal resistance JA 85 C/W Power dissipation (Note 3) PD 1.18 W Note 1: Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other parameters set at or below their nominal value. Exceeding any of the limits listed may result in permanent damage to the device. Note 2: The current rating is based on long-term current density limitations. Note 3: Mounted on an FR4 board. Derated 11.8 mW/ C above 25 C. CAUTION: Although this device is designed to be as robust as possible, Electrostatic Discharge (ESD) can damage this device. This device must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times. Electrical and Mechanical Specifications The absolute maximum ratings of the AAT4616A are provided in Table 2. The recommended operating conditions are specified in Table 3, and electrical specifications are provided in Table 4. Typical performance characteristics of the AAT4616A are illustrated in Figures 3 through 14. Skyworks Solutions, Inc. * Phone [781] 376-3000 * Fax [781] 376-3100 * sales@skyworksinc.com * www.skyworksinc.com 2 September 12, 2013 * Skyworks Proprietary Information * Products and Product Information are Subject to Change Without Notice * 201941E DATA SHEET * AAT4616A HIGH PRECISION ADJUSTABLE CURRENT LIMITED LOAD SWITCH WITH FAULT FLAG Table 3. Recommended Operating Conditions Parameter Symbol Minimum Input voltage VIN 2.4 High-level Input voltage VON(H) 1.4 Low-level Input voltage VON(L) Operating temperature TA Typical Maximum Units 5.5 V 0.5 V +85 C V -40 Table 4. AAT4616A Electrical Specifications (Note 1) (VIN = 5 V, TA = -40 C to +85 C [Typical Values are at TA = 25 C], Unless Otherwise Noted) Parameter Symbol Test Condition Max Units 5.5 V 10 25 A ON/ON = Inactive, VIN = 5.5 V 0.01 1 A ON/ON = Inactive, VIN = 5.5 V, VOUT = 0 V 0.01 1 A 1.8 2.4 Input voltage VIN Operating quiescent current IQ Off supply current IQ(OFF) Off switch current ISD(OFF) Under-Voltage Lockout VUVLO Rising edge, 1% Hysteresis UVLO hysteresis VUVLO_HYS RDS(ON) On resistance Min Typical 2.4 VIN = 5 V, ON/ON = Active, IOUT = 0 A 10 VIN = 5.0 V, TA = 25 C 130 180 VIN = 3.0 V, TA = 25 C 150 230 On-resistance temperature coefficient TCRDS Current limit ILIM Minimum current limit ILIM(MIN) 2800 ON/ON input low voltage VON(L) ON/ON input high voltage VON(H) VIN = 2.4 V to 5.5 V ON/ON input leakage ION(SINK) VON = 5.5 V Current limit response time tRESP VIN = 5 V Turn-on time tON VIN = 5 V, RLOAD = 10 Turn-off time tOFF VIN = 5 V, RLOAD = 10 Fault flag blanking time tBLANK Fault flag logic low output VFLT(L) Fault flag logic high leakage current IFLT(SINK) Over-temperature shutdown threshold TSD Over-temperature shutdown hysteresis TSD_HYS RSET = 35 k, VOUT = VIN - 0.5 V 0.67 0.75 0.83 0.5 V 1 A V 0.01 s 2 4 7 s s 10 4 IFLT(SINK) = 1 mA ms 0.4 V 1 A 0.03 VIN = 5 V A mA 1.4 8 m ppm/C 300 VIN = 2.4 V to 5.5 V V mV 140 C 15 C Note 1: Performance is guaranteed only under the conditions listed in this Table. Skyworks Solutions, Inc. * Phone [781] 376-3000 * Fax [781] 376-3100 * sales@skyworksinc.com * www.skyworksinc.com 201941E * Skyworks Proprietary Information * Products and Product Information are Subject to Change Without Notice * September 12, 2013 3 DATA SHEET * AAT4616A HIGH PRECISION ADJUSTABLE CURRENT LIMITED LOAD SWITCH WITH FAULT FLAG Typical Performance Characteristics Figure 3. Quiescent Current vs Temperature (VIN = 5.0 V) Figure 4. Current Limit vs Output Voltage (VIN = 5.0 V, TA = 25 C, RSET = 34.8 k) Figure 5. Quiescent Current Voltage (TA = 25 C) Figure 6. Off-Switch Current vs Temperature (VIN = 5.0 V) Figure 7. RDS(ON) vs Temperature Figure 8. RSET vs ILIM (TA = 25 C) Skyworks Solutions, Inc. * Phone [781] 376-3000 * Fax [781] 376-3100 * sales@skyworksinc.com * www.skyworksinc.com 4 September 12, 2013 * Skyworks Proprietary Information * Products and Product Information are Subject to Change Without Notice * 201941E DATA SHEET * AAT4616A HIGH PRECISION ADJUSTABLE CURRENT LIMITED LOAD SWITCH WITH FAULT FLAG Typical Performance Characteristics Figure 9. ON(ON) Threshold vs Input Voltage Figure 10. AAT4616AIPU-1 Turn-On (RL = 10 , CL = 0.47 F) Figure 11. Figure 10. AAT4616AIPU-1 Turn-Off (RL = 10 , CL = 0.47 F) Figure 12. Short Circuit Through 0.3 (VIN = 5.0 V) Figure 13. Output Short Response (VIN = 5.0 V) Figure 14. Fault Blanking Time (VIN = 5.0 V) Skyworks Solutions, Inc. * Phone [781] 376-3000 * Fax [781] 376-3100 * sales@skyworksinc.com * www.skyworksinc.com 201941E * Skyworks Proprietary Information * Products and Product Information are Subject to Change Without Notice * September 12, 2013 5 DATA SHEET * AAT4616A HIGH PRECISION ADJUSTABLE CURRENT LIMITED LOAD SWITCH WITH FAULT FLAG Figure 15. AAT4616A Functional Block Diagram Functional Description The AAT4616A is a single channel current limiting load switch that is intended to protect against short circuit and over-current events by current limiting to a preset level. This device also provides a reverse current blocking feature, on/off enable control, and a fault flag to notify a system controller of an overcurrent, short circuit or over-temperature event. In the event of a load current that exceeds a user-programmed current limit level (ILIM), a high speed current limit loop limits the current in a microsecond and resets to low impedance once the short circuit condition is removed. The AAT4616A is internally protected from thermal damage by an over-temperature detection circuit. If the die temperature reaches the internal thermal limit, the power device is switched off until the die temperature cools to a level below the thermal limit threshold. This device may operate in a thermal cycling state indefinitely or until the over-current condition is removed. The AAT4616A operates with input voltages ranging from 2.4 V to 5.5 V which, along with its extremely low operating current, make it ideal for battery-powered applications. In cases where the input voltage drops to below 2.4 V, the AAT4616A MOSFET is protected from entering the saturated region of operation by being automatically shut down by the UVLO circuit. Current limit or over-temperature conditions are reported by the open drain FAULT output. A 4 ms blanking interval prevents false reporting during the charging of a capacitive load, which typically occurs during device turn-on, but may also occur during a port hot plug-in event. The AAT4616A is ideally suited for protection of peripheral ports such as USB, RS232, and parallel ports. Reverse Current Blocking The reverse current blocking feature prevents current flowing from OUT to IN when the device is disabled. When the device is enabled, the electrical characteristics between IN and OUT are still similar to an ideal switch, and current can flow in either direction. Application Information Setting Current Limit The AAT4616A current limit can be set by an external resistor (RSET) connected from the SET pin to GND. RSET can be calculated by the following equation: where ILIM is in mA and RSET in k. Table 5 summarizes resistor values for current limit settings. Use 1% tolerance metal film resistors to program the desired current limit setting. Figure 16 shows the output current versus output voltage with RSET equal to 34.8 k. Skyworks Solutions, Inc. * Phone [781] 376-3000 * Fax [781] 376-3100 * sales@skyworksinc.com * www.skyworksinc.com 6 September 12, 2013 * Skyworks Proprietary Information * Products and Product Information are Subject to Change Without Notice * 201941E DATA SHEET * AAT4616A HIGH PRECISION ADJUSTABLE CURRENT LIMITED LOAD SWITCH WITH FAULT FLAG Table 5. Recommended 1% Tolerance Metal Film Resistors RSET for Current Limit RSET (k) Current Limit (mA) 86.6 300 51 500 34.8 750 26.1 1000 21.5 1200 18.2 1400 16.5 1600 Output Capacitor To ensure stability while the current limit is active, a low capacitance (approximately 0.47 F) is required. No matter how large the output capacitor, the output current is limited to the value set by the AAT4616A current limiting circuitry, so very large output capacitors can be used. For example, USB ports are specified to have at least 120 F of capacitance downstream from their controlling power switch. The current limiting circuit allows an output capacitance of 1000 F or more without disturbing the upstream power supply. ON/ON (Enable Input) In many systems, power planes are controlled by integrated circuits that run at lower voltages than the power planes, themselves. The enable input (ON/ON) of the AAT4616A has low and high threshold voltages that accommodate this condition. The threshold voltages are compatible with 5 V TTL and 2.5 V 5 V CMOS systems. Both active high and active low options are available. Connecting to Capacitive Load When the AAT4616A is switched onto a capacitive load, the device charges the output capacitive load at a rate no greater than the current limit setting. Figure 16. Current Limit vs Output Voltage with 34.8 k RSET Input Capacitor The input capacitor CIN protects the power supply from current transients generated by the load attached to the AAT4616A. When a short circuit is suddenly applied to the output of the AAT4616A, a large current, limited only by the RDS(ON) of the MOSFET, flows for less than 1 s before the current limit circuitry activates. In this event, a moderately sized CIN dramatically reduces the voltage transient seen by the power supply and by other circuitry upstream from the AAT4616A. The extremely fast short-circuit response time of the AAT4616A reduces the size requirement for CIN. CIN should be located as close to the device VIN pin as practically possible. Ceramic, tantalum, or aluminum electrolytic capacitors are appropriate for CIN. There is no specific capacitor Equivalent Series Resistance (ESR) requirement for CIN. For higher current operation, ceramic capacitors are recommended for CIN due to their inherent capability over tantalum capacitors to withstand input current surges from low impedance sources such as batteries in portable devices. FAULT Output The FAULT Flag FLT is provided to alert the system if an AAT4616A load is not receiving sufficient voltage to operate properly. If current limit or over-temperature circuits in any combination are active for more than approximately 4 ms, the FAULT Flag is pulled to ground through an approximately 100 resistor. The filtering of voltage or current transients of less than 4 ms prevents capacitive loads connected to the AAT4616A output from activating the FAULT Flag when they are initially attached. Pull-up resistances of 10 k to 100 k are recommended. Since FLT is an open-drain terminal; it may be pulled up to any unrelated voltage less than the maximum operating voltage of 5.5 V, allowing for level shifting between circuits. Skyworks Solutions, Inc. * Phone [781] 376-3000 * Fax [781] 376-3100 * sales@skyworksinc.com * www.skyworksinc.com 201941E * Skyworks Proprietary Information * Products and Product Information are Subject to Change Without Notice * September 12, 2013 7 DATA SHEET * AAT4616A HIGH PRECISION ADJUSTABLE CURRENT LIMITED LOAD SWITCH WITH FAULT FLAG Thermal Considerations Since the AAT4616A has internal current limit and overtemperature protection, junction temperature is rarely a concern. However, if the application requires large currents in a hot environment, it is possible that temperature, rather than current limit, is the dominant regulating condition. In these applications, the maximum current available without risk of an overtemperature condition must be calculated. The maximum internal temperature while the current limit is inactive can be calculated using the following equation: Note that TJ(MAX) has been replaced by TSD(MIN), the minimum temperature required to activate the over-temperature protection feature of the AAT4616A. With the typical specification of 140 C, a safe minimum value to use would be 125 C. For example, if an application is specified to operate in 50 C environments, the PCB operates at temperatures as high as 85 C. The application is sealed and its PCB is small, causing RJA to be approximately 85 C/W. Using equation (2): (1) Where: IMAX is the maximum current required by the load. RDS(ON)(MAX) is the maximum rated RDS(ON) of the AAT4616A at high temperature. RJA is the thermal resistance between the AAT4616A die and the board onto which it is mounted. Evaluation Board Information The AAT4616A Evaluation Board schematic diagram is provided in Figure 17. The PCB layer details are shown in Figure 18, and Table 6 lists the Evaluation Board Bill of Materials (BOM). TA(MAX) is the maximum temperature that the PCB under the AAT4616A would be if the AAT4616A were not dissipating power. Rearranging equation (1) to solve for IMAX: (2) Figure 17. AAT4616A Evaluation Board Schematic Table 6. AAT4616A Evaluation Board Bill of Materials (BOM) Component Part Number Description Manufacturer U1 AAT4616AIPU-T1 Current Limited Load Switch Skyworks C1 GRM188R71C105K Ceramic capacitor, 1 F, 0603 X7R, 16 V, 10% Murata C2 GRM188R71C474K Ceramic capacitor, 0.47 F, 0603 X7R, 16 V, 10% Murata RSET Chip Resistor Resistor, 34.8 k, 1/16 W, 1%, 0603 SMD Vishay R2 Chip Resistor Resistor, 100 k, 1/16 W, 1%, 0603 SMD Vishay Skyworks Solutions, Inc. * Phone [781] 376-3000 * Fax [781] 376-3100 * sales@skyworksinc.com * www.skyworksinc.com 8 September 12, 2013 * Skyworks Proprietary Information * Products and Product Information are Subject to Change Without Notice * 201941E DATA SHEET * AAT4616A HIGH PRECISION ADJUSTABLE CURRENT LIMITED LOAD SWITCH WITH FAULT FLAG Figure 18. AAT4616A Evaluation Board Layer Details Package Information Package dimensions for the TDFN22-6 are shown in Figure 19, and tape and reel dimensions are provided in Figure 20. Skyworks Solutions, Inc. * Phone [781] 376-3000 * Fax [781] 376-3100 * sales@skyworksinc.com * www.skyworksinc.com 201941E * Skyworks Proprietary Information * Products and Product Information are Subject to Change Without Notice * September 12, 2013 9 DATA SHEET * AAT4616A HIGH PRECISION ADJUSTABLE CURRENT LIMITED LOAD SWITCH WITH FAULT FLAG Figure 19. AAT4616A TDFN22-6 Package Dimensions Figure 20. AAT4616A Tape and Reel Dimensions Skyworks Solutions, Inc. * Phone [781] 376-3000 * Fax [781] 376-3100 * sales@skyworksinc.com * www.skyworksinc.com 10 September 12, 2013 * Skyworks Proprietary Information * Products and Product Information are Subject to Change Without Notice * 201941E DATA SHEET * AAT4616A HIGH PRECISION ADJUSTABLE CURRENT LIMITED LOAD SWITCH WITH FAULT FLAG Ordering Information Model Name AAT4616A Adjustable Current Limited Load Switch with Fault Flag Enable Input Package Marking (Note 1) Manufacturing Part Number (Note 2) Evaluation Board Part Number Active High TDFN22-6 R9XYY AAT4616AIPU-1-T1 AAT4616AIPU-1-EVB Active Low TDFN22-6 U4WBF AAT4616AIPU-T1 AAT4616AIPU-EVB Note 1: XYY = assembly and date code. Note 2: Sample stock is generally held on part numbers listed in BOLD. Copyright (c) 2013 Skyworks Solutions, Inc. All Rights Reserved. Information in this document is provided in connection with Skyworks Solutions, Inc. ("Skyworks") products or services. These materials, including the information contained herein, are provided by Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes. No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions of Sale. THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury, death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any damages resulting from such improper use or sale. Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters. Skyworks, the Skyworks symbol, and "Breakthrough Simplicity" are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by reference. Skyworks Solutions, Inc. * Phone [781] 376-3000 * Fax [781] 376-3100 * sales@skyworksinc.com * www.skyworksinc.com 201941E * Skyworks Proprietary Information * Products and Product Information are Subject to Change Without Notice * September 12, 2013 11