TCB Series COTS-Plus Polymer Capacitor The TCB series is a COTS-Plus version of the professional grade TCR polymer series. FEATURES * Robust design for long operation lifetime * AVX Q-process with statistical screening * 100% Accelerated Ageing * Surge testing level option * Improved basic reliability 0.5%/1000hrs * Humidity 85C/85%RH, Vr, 500/1000 hours * - 55 to +125C operation temperature * Shock and Vibration by MIL-STD-202 * DCL 0.1 CV * 3x reflow 260C compatible * Benign failure mode under recommended use conditions APPLICATIONS L W H A S A W1 MARKING Long life time DC/DC converter applications in Telecommunications, Industrial, Avionics. For additional information on Q-process please consult the AVX technical publication "Reaching the Highest Reliability for Tantalum Capacitors" (see the link: http://www.avx.com/docs/techinfo/Qprocess.pdf) CASE DIMENSIONS: millimeters (inches) B, D, Y CASE AVX LOGO Polymer Polarity Band (Anode+) Code Capacitance Value in pF 686 = 68F 686 A XXXXX Rated Voltage A = 10V ID Code EIA Code EIA Metric L0.20 (0.008) W+0.20 (0.008) -0.10 (0.004) H+0.20 (0.008) -0.10 (0.004) W10.20 (0.008) A+0.30 (0.012) -0.20 (0.008) S Min. B 1210 3528-21 3.50 (0.138) 2.80 (0.110) 1.90 (0.075) 2.20 (0.087) 0.80 (0.031) 1.40 (0.055) D 2917 7343-31 7.30 (0.287) 4.30 (0.169) 2.90 (0.114) 2.40 (0.094) 1.30 (0.051) 4.40 (0.173) Y 2917 7343-20 7.30 (0.287) 4.30 (0.169) 2.00 (0.079) max 2.40 (0.094) 1.30 (0.051) 4.40 (0.173) W1 dimension applies to the termination width for A dimensional area only. CAPACITANCE AND RATED VOLTAGE, VR (VOLTAGE CODE) RANGE (LETTER DENOTES CASE SIZE) Capacitance F Code 10 106 15 156 22 226 33 336 47 476 68 686 100 107 150 157 220 227 4V(G) 10V(A) Rated Voltage 16V(C) 20V(D) 25V(E) 35V(V) D(70) 50V(T) D(120) D(70) B(70) B(70) B(70) D(70) D(70) D(70) D(70) D(70) D(40) D(40), Y(40) Available Ratings (ESR ratings in mOhms in brackets) Engineering samples - please contact manufacturer 88 6.3V(J) Note: Voltage ratings are minimum values. AVX reserves the right to supply higher voltage ratings in the same case size to the same reliability standards 102417 TCB Series COTS-Plus Polymer Capacitor HOW TO ORDER AVX PART NUMBER: TCB D Type 107 Case Capacitance Size Code See pF code: table 1st two digits on represent previ significant ous figures 3rd digit page represents multiplier (number of zeros to follow) M Tolerance M = 20% 010 C Rated DC ESR Voltage C = Std ESR L = Low ESR 004 = 4Vdc 006 = 6.3Vdc 010 = 10Vdc 016 = 16Vdc 020 = 20Vdc 025 = 25Vdc 035 = 35Vdc 050 = 50Vdc Packaging R = 7" T&R S = 13" T&R S Z 0 ^ Inspection Level Reliability Qualification Termination Finish S = Standard Grade Level 7 = 100% Tin Conformance Z = Non-ER 0 = N/A H* = Sn/Pb Non RoHS *Contact Manufacturer 00 Surge Test Option 00 = Standard 23 = 10x Cycles, 25C 24* = 10x Cycles, -55C & +85C *Please contact AVX for Surge option TECHNICAL SPECIFICATIONS Technical Data: Capacitance Range: Capacitance Tolerance: Leakage Current DCL: Temperature Range: Basic Reliability: Termination Finish: All technical data relate to an ambient temperature of +25C 10F to 220F 20% 0.1CV -55C to +125C 0.5% per 1000 hours at 85C, Vr with 0.1V series impedance, 60% confidence level Sn Plating or SnPb Plating (Non RoHS) NOTE: Conductive Polymer Capacitors are designed to operate within the limits of the environmental conditions specified for each series. If operated continuously at their maximum temperature and / or humidity limit, or beyond these limits, capacitors may exhibit a parametric shift in capacitance and increases in ESR. These changes may occur earlier if the specified environmental conditions are exceeded. Similarly, their normal operational time period will be significantly extended if their general duty cycle includes operation below maximum temperature within humidity controlled environments. Careful attention should be paid to maximum temperature with associated high humidity environments as well as voltage derating, ripple current and current surges. Please reference the AVX Conductive Polymer Capacitor Guidelines for more information or contact factory for application assistance. 110916 89 TCB Series COTS-Plus Polymer Capacitor RATINGS & PART NUMBER REFERENCE AVX Part No. Case Capacitance Size (F) Maximum Operating Temperature (C) Rated Voltage (V) DCL Max. (A) ESR Max. @ 100kHz (m) MSL 45C 85C 105C 125C Humidity 85C/ 85%RH, Vr (hrs) 6 6 6 6 40 40 40 40 3 3 3 3 2400 2400 2200 2200 1700 1700 1500 1500 1100 1100 1000 1000 600 600 600 600 1000 1000 500 500 6 6 6 6 6 6 6 6 70 70 70 70 70 70 40 40 3 3 3 3 3 3 3 3 1300 1300 1300 1300 1300 1300 2400 2400 900 900 900 900 900 900 1700 1700 600 600 600 600 600 600 1100 1100 300 300 300 300 300 300 600 600 500 500 500 500 500 500 1000 1000 6 6 6 6 70 70 70 70 3 3 3 3 1800 1800 1800 1800 1300 1300 1300 1300 800 800 800 800 500 500 500 500 1000 1000 1000 1000 6 6 6 6 70 70 70 70 3 3 3 3 1800 1800 1800 1800 1300 1300 1300 1300 800 800 800 800 500 500 500 500 1000 1000 1000 1000 8 8 70 70 3 3 1800 1800 1300 1300 800 800 500 500 1000 1000 8 8 70 70 3 3 1800 1800 1300 1300 800 800 500 500 1000 1000 8 8 70 70 3 3 1800 1800 1300 1300 800 800 500 500 1000 1000 10 10 120 120 3 3 1400 1400 1000 1000 600 600 400 400 500 500 DF Max. (%) 100kHz RMS Current (mA) 4 Volt TCBD227M004CSZ0700 TCBD227M004CSZ0723 TCBY227M004CSZ0700 TCBY227M004CSZ0723 D D Y Y 220 220 220 220 4 4 4 4 125 125 125 125 88 88 88 88 TCBB226M006CSZ0700 TCBB226M006CSZ0723 TCBB336M006CSZ0700 TCBB336M006CSZ0723 TCBB476M006CSZ0700 TCBB476M006CSZ0723 TCBD157M006CSZ0700 TCBD157M006CSZ0723 B B B B B B D D 22 22 33 33 47 47 150 150 6.3 6.3 6.3 6.3 6.3 6.3 6.3 6.3 125 125 125 125 125 125 125 125 13 13 19 19 28 28 90 90 TCBD686M010CSZ0700 TCBD686M010CSZ0723 TCBD107M010CSZ0700 TCBD107M010CSZ0723 D D D D 68 68 100 100 10 10 10 10 125 125 125 125 68 68 100 100 TCBD336M016CSZ0700 TCBD336M016CSZ0723 TCBD476M016CSZ0700 TCBD476M016CSZ0723 D D D D 33 33 47 47 16 16 16 16 125 125 125 125 52 52 75 75 TCBD226M020CSZ0700 TCBD226M020CSZ0723 D D 22 22 20 20 125 125 44 44 TCBD156M025CSZ0700 TCBD156M025CSZ0723 D D 15 15 25 25 125 125 37 37 TCBD106M035CSZ0700 TCBD106M035CSZ0723 D D 10 10 35 35 125 125 35 35 TCBD106M050CSZ0700 TCBD106M050CSZ0723 D D 10 10 50 50 125 125 50 50 6.3 Volt 10 Volt 16 Volt 20 Volt 25 Volt 35 Volt 50 Volt Moisture Sensitivity Level (MSL) is defined according to J-STD-020. All technical data relates to an ambient temperature of +25C. Capacitance and DF are measured at 120Hz, 0.5V RMS with a maximum DC bias of 2.2 volts. DCL is measured at rated voltage after 5 minutes. ESR allowed to move up to 1.25 times catalog limit post mounting. NOTE: AVX reserves the rights to supply higher voltage rating or tighter tolerance part in the same case size, to the same reliability standards. RECOMMENDED DERATING FACTOR Voltage and temperature derating as percentage of Vr. For Vr 10V 100% 95% For Vr 16V 100% Rated Voltage 95% 90% 85% Rated voltage 10V 16V Operating Temperature 85C 105C 125C 90% 90% 60% 80% 80% 54% 80% Recommended Application Voltage 85% 80% 75% 75% 70% 70% 67% 65% 60% 60% 55% 50% 105C 125C 67% 60% 50% 85C Recommended Application Voltage 65% 55% -55% 90 Rated Voltage 90% -55% 54% 85C 105C 125C 110916 TCB Series COTS-Plus Polymer Capacitor QUALIFICATION TABLE TEST Endurance Storage Life Biased Humidity Temperature Stability Surge Voltage Mechanical Shock/Vibration TCB series (Temperature range -55C to +125C) Characteristics Visual examination no visible damage Determine after application of rated voltage for 2000 +48/-0 hours at 1052C. Also determine after appliDCL 1.25 x initial limit cation of 125C temperature, 2/3 rated voltage for C/C within +20/-30% of initial value 2000 +48/-0 hours. After test leaving 1-2 hours at DF 1.5 x initial limit room temperature. Power supply impedance to be 0.1/V. ESR 2 x initial limit Visual examination no visible damage DCL 2 x initial limit 125C, 0V, 2000h C/C within 20% of initial value DF 1.5 x initial limit ESR 2 x initial limit Visual examination no visible damage DCL 3 x initial limit Determine after leaving for 500 or 1000 hours at 852C, 85% relative humidity and rated voltage C/C within +30/-20% of initial value and then recovery 1-2 hours at room temperature. DF 1.5 x initial limit ESR 2 x initial limit Condition Step 1 2 3 4 5 6 TemperatureC +202 -55+0/-3 +202 +85+3/-0 +125+3/-0 +202 Duration(min) 15 15 15 15 15 15 Test temperature: 125C+3/0C Surge voltage: 1.3 x2/3 rated voltage Charge/Discharge resistance: 1000100 Number of cycles: 1000x Cycle duration: 6min; 30sec charge, 5min 30sec discharge MIL-STD-202, Method 213, Condition I, 100 G peak MIL-STD-202, Method 204, Condition D, 10 Hz to 2,000 Hz, 20 G peak +20C -55C +20C +85C +125C +20C DCL IL* n/a IL* C/C n/a +0/-20% 5% DF Visual examination DCL C/C DF ESR Visual examination DCL C/C DF ESR IL* 1.5 x IL* IL* no visible damage initial limit within +20/-30% of initial value 1.25 x initial limit 1.25 x initial Limit no visible damage initial limit within 10% of initial value initial limit 1.25 x initial Limit 10 x IL* 12.5 x IL* IL* +20/-0% +30/-0% 5% 1.5 x IL* 2 x IL* IL* *Initial Limit For use outside of recommended conditions and special request, please contact manufacturer. Initial measurement max. 1hr after the removal from dry pack or after pretreatment at 85C for 24 hours. 110916 91