Polysnap Power Inlet Modules [B/BULGIN IEC Inlet - Earth Line Choke Filter a EMI filter options for Polysnap modules BZV03, BZV04, BZV09, BZV10, BZV17, BZV18, BZHO9, BZH10, BZH17, BZH18, BZM27, BZM28 PX0575 style IEC inlet Using PSO9/A style filter Earth Line Choke Attenuation Filter Bxooa/ Exx x x / xx | ae | Additional Ey Polysnap Part No. Filter Type Rating L/C Circuit Components Polysnap Part No. a From Polysnap Selection E = Earth Line Choke 0O1= 1A ] = Version | 0 = None From Polysnap Selection re 03 = 3A 3 = Version 3 ] = Bleed (R) Resistor 06 = 6A 2 = Surge (VDR) Protection 3 = R plus VDR Rating | Version | L1 | & | cy | 2 Part No. Example ] AMP ; 2x 6.3mH 1 x 15nF 2 x 2.2nF 0.2mH BZM27/E0331/59B = " 3 2 x 6.3mH 1x 47nF 2x 2.2nF 0.4mH BZM style Polysnap module with PX0575 style 3 AMP 1 2 x 1.2mH 1x 15nF 2 x 2.2nF 0.2mH IEC power inlet, filter rated at 3 amps, L/C 2 circuit version 3 (L1 = 2 x 1.2mH, Cx = 1 x 3 2x 1.2mH 1 x 47nF 2x 2.2nF 0.4mH ATE Cy = 2 x 2.2nF L2 = 1 x 0.4mH), with & AMP ] 2 x 0.45mH 1 x 15nF 2 x 2.2nF 0.2mH bleed resistor fitted, without surge protection . 2 device fitted, 6.3mm tabs and double pole red 3 2 x 0.45mH 1 x 47nF 2x 2.2nF 0.4mH illuminated switch, panel thickness 1.5mm. 10 AMP ] a 2 a 3 Filter Specification | Max. Working Voltage: Earth Leakage Current: Temperature Range: Max. Ambient Temp.: (@ Full Load) Test Voltage: Approvals: Attenuation Curves: 250V a.c. 50-400Hz <0.35mA (250V. 50Hz) -25C to +85C 40C (derate linearly to OA @ 85C) 2700V d.c. 2 secs. Lines to Earth 1100V d.c. 2 secs. Live to Neutral &EW See PSO9/A filter, page 123 www.Bulgin.co.uk Tel: +44 (0) 20 8594 5588 79