[ 73 ]
201 McLean Boulevard Paterson, New Jersey 07504 T el: (973) 881-8800 Fax: (973) 881-8361
E-Mail: sales@synergymwave.com W orld Wide Web: http://www .synergymwave.com
MIXERS
DOUBLE -BALANCED
MIXERS
DOUBLE -BALANCED
LO = +23 dBm
0.5 - 500 DC - 500 6.2/7 6.4/8.5 55/44 44/25 33/20 50/34 45/25 37/22 159 1 SLD-K1H*
0.5 - 500 DC - 500 6.2/7 6.4/8.5 55/44 44/25 33/20 50/34 45/25 37/22 134 1 SMD-K1H*
0.5 - 500 DC - 500 6.2/7 6.4/8.5 55/44 44/25 33/20 50/34 45/25 37/22 134J 1 SMZ-K1H*
1-1000 DC-1000 6.5/7.5 7.5/9.5 70/45 45/30 40/25 60/40 35/23 30/15 133 3 SMD-C1H
5 - 1000 DC - 900 7/8.5 7.8/9.3 55/40 39/22 33/20 52/30 45/22 39/22 159 1 SLD-K2H*
5 - 1000 DC - 900 7/8.5 7.8/9.3 55/40 39/22 33/20 52/30 45/22 39/22 134 1 SMD-K2H*
5 - 1000 DC - 900 7/8.5 7.8/9.3 55/40 39/22 33/20 52/30 45/22 39/22 134J 1 SMZ-K2H*
5 - 1500 DC - 900 6.3/8 7.5/9.8 65/40 36/20 22/15 50/30 30/18 17/7 159 1 SLD-K3H*
5 - 1500 DC - 900 6.3/8 7.5/9.8 65/40 36/20 22/15 50/30 30/18 17/7 134 1 SMD-K3H*
5 - 1500 DC - 900 6.3/8 7.5/9.8 65/40 36/20 22/15 50/30 30/18 17/7 134J 1 SMZ -K3H*
5 - 2500 3 - 600 8/9.5 10.5/12 60/35 40/25 35/20 50/35 30/20 25/15 159 1 SLD-K4H
5 - 2500 3 - 600 8/9.5 10.5/12 60/35 40/25 35/20 50/35 30/20 25/15 134 1 SMD-K4H
5 - 2500 3 - 600 8/9.5 10.5/12 60/35 40/25 35/20 50/35 30/20 25/15 134J 1 SMZ-K4H
20-1500 DC-1500 7.0/8.5 8.5/9.0 50/35 40/25 20/10 40/25 30/18 15/8 133 3 SMD-C2H
20-2500 20-600 8.0/9.0 9.0/10.5 45/30 30/23 30/15 40/20 25/15 25/12 133 3 SMD-C3H
Super-High Dynamic Range
SURFACE MOUNT
FLAT PACK
0.01-125 DC - 125 5.5/6 6/6.5 60/50 50/40 40/35 60/45 50/35 40/30 101 2 CHF-102
0.025-200 DC - 200 5.5/6 6/7 65/55 55/45 45/35 60/50 45/35 35/30 101 2 CHF-112
0.1 - 500 DC - 500 6/7 7/8 65/40 60/40 50/30 45/30 50/35 35/20 1 01 2 CHF-101
0.5 - 1000 DC - 1000 5.5/7 7/8.5 70/40 45/35 40/25 60/40 40/30 30/20 101 2 CHF-103
10 - 2000 5 - 600 7/8.5 7.5/9 60/35 40/25 40/20 50/30 30/20 25/15 101 2 CHF-109
20 - 1500 DC - 1000 7.5/8.5 8/9 60/35 40/25 25/20 50/30 40/25 20/12 101 2 CHF-111
800-2500 D C - 400 --/-- 6.5/8.5 30/20 30/20 30/20 20/10 20/10 20/10 101 2 CHF-104
NOTES:
* Phase Detection, Polarity Positive
1. 1dB Compression Point = +15 dBm (Typ)
2. IP3 (Input) = +26 dBm (Typ)
3. Maximum Input Power without damage = 500 mW ave. cw
FREQUENCY RANGE
(MHz) CONVERSION
LOSS (dB)
RF/LO IF
XMB
TYP/MAX
FULL
BAND
TYP/MAX LB
TYP/MIN MB
TYP/MIN UB
TYP/MIN LB
TYP/MIN MB
TYP/MIN UB
TYP/MIN
LO-RF ISOLATION
(dB) LO-IF ISOLATION
(dB) PACKAGE MODEL
PIN
OUT
FREQUENCY RANGE
(MHz) CONVERSION
LOSS (dB)
RF/LO IF
XMB
TYP/MAX
FULL
BAND
TYP/MAX LB
TYP/MIN MB
TYP/MIN UB
TYP/MIN LB
TYP/MIN MB
TYP/MIN UB
TYP/MIN
LO-RF ISOLATION
(dB) LO-IF ISOLATION
(dB) PACKAGE MODEL
PIN
OUT
XM B= 2LF to HF/2
FULL BAND = LF to HF
LB= LF to 10LF
MB = 10LF to HF/2
UB= HF/2 to HF
#1 4 1 5 2, 3,6 --
#2 1 4 5 2,3,6,7,8 2,3,6,7,8
#3 1 2 3 4,5,6 --
RF LO IF GND CASE GND
GND = Ground externally
For pin location and package outline drawings, see back pages.
PIN-OUT TABLE
159
134J
134
133
[ 74 ]
201 McLean Boulevard Paterson, New Jersey 07504 T el: (973) 881-8800 Fax: (973) 881-8361
E-Mail: sales@synergymwave.com W orld Wide Web: http://www .synergymwave.com
MIXERS
DOUBLE -BALANCED
MIXERS
DOUBLE -BALANCED
FREQUENCY RANGE
(MHz) CONVERSION
LOSS (dB)
RF/LO IF
XMB
TYP/MAX
FULL
BAND
TYP/MAX LB
TYP/MIN MB
TYP/MIN UB
TYP/MIN LB
TYP/MIN MB
TYP/MIN UB
TYP/MIN
LO-RF ISOLATION
(dB) LO-IF ISOLATION
(dB) PACKAGE MODEL
PIN
OUT
0.01-125 DC-125 5.5/6 6/6.5 60/50 50/40 40/35 60/45 50/35 40/30 102 1 CHP-202
0.025-200 DC-200 5.5/6 6/7 65/55 55/45 45/35 60/50 45/35 35/30 103 1 CHP-212
0.1-500 DC-500 6/7 7/8 65/40 60/40 50/30 45/30 50/35 35/20 103 1 CHP-201
0.5-1000 DC-1000 5.5/7 7/8.5 70/40 45/35 40/25 60/40 40/30 30/20 103 2 CHP-203
20-1500 DC-1000 7.5/8.5 8/9 60/35 40/25 25/20 50/30 40/25 20/12 102 2 CHP-211
10-2000 5-600 7/8.5 7.5/9 60/35 40/25 40/20 50/30 30/20 25/15 120 3 CHP-209
800-2500 DC-400 --/-- 6.5/8.5 30/20 30/20 30/20 20/10 20/10 20/10 120 3 CHP-204
THROUGH HOLE (RELAY)
NOTES:
1. 1dB Compression Point = +17 dBm (Typ)
2. IP3 (Input) = +26 dBm (Typ)
3. Maximum Input Power without damage = 500 mW ave. cw
LO = +23 dBm Super-High Dynamic Range
FREQUENCY RANGE
(MHz) CONVERSION
LOSS (dB)
RF/LO IF
XMB
TYP/MAX
FULL
BAND
TYP/MAX LB
TYP/MIN MB
TYP/MIN UB
TYP/MIN LB
TYP/MIN MB
TYP/MIN UB
TYP/MIN
LO-RF ISOLATION
(dB) LO-IF ISOLATION
(dB) PACKAGE MODEL
PIN
OUT
XMB= 2LF to HF/2
FULL BAND = LF to HF
LB= LF to 10LF
MB = 10LF to HF/2
UB= HF/2 to HF
GND = Ground externally
For pin location and package outline drawings, see back pages.
RF LO I F GND CASE GND NO CONN.
#1 1 8 *3,4 2,5,6,7 2 --
#2 1 8 *3,4 2,5,6,7 2,5,6,7 --
#3 1 8 3 2,5,6,7 2,5,6,7 4
#4 1 4 2 3 3 --
PIN-OUT T ABLE
103102
106105 107 108
THROUGH HOLE (MINI-RELAY)
120
0.01-125 DC-125 5.5/6 6/6.5 60/50 50/40 40/35 60/45 50/35 40/30 105 4 CHP-302
0.025-200 DC-200 5.5/6 6/7 65/55 55/45 45/35 60/50 45/35 35/30 105 4 CHP-312
0.1-500 DC-500 6/7 7/8 65/40 60/40 50/30 45/30 50/35 35/20 106 4 CHP-301
0.5-1000 DC-1000 5.5/7 7/8.5 70/40 45/35 40/25 60/40 40/30 30/20 106 4 CHP-303
20-1500 DC-1000 7.5/8.5 8/9 60/35 40/25 25/20 50/30 40/25 20/12 106 4 CHP-311
10-2000 5-600 7/8.5 7.5/9 60/35 40/25 40/20 50/30 30/20 25/15 105 4 CHP-309
0.01-125 DC-125 5.5/6 6/6.5 60/50 50/40 40/35 60/45 50/35 40/30 107 1 CHP-402
0.025-200 DC-200 5.5/6 6/7 65/55 55/45 45/35 60/50 45/35 35/30 107 1 CHP-412
0.1-500 DC-500 6/7 7/8 65/40 60/40 50/30 45/30 50/35 35/20 108 1 CHP-401
0.5-1000 DC-1000 5.5/7 7/8.5 70/40 45/35 40/25 60/40 40/30 30/20 108 2 CHP-403
20-1500 DC-1000 7.5/8.5 8/9 60/35 40/25 25/20 50/30 40/25 20/12 107 2 CHP-411
[ 75 ]
201 McLean Boulevard Paterson, New Jersey 07504 T el: (973) 881-8800 Fax: (973) 881-8361
E-Mail: sales@synergymwave.com W orld Wide Web: http://www .synergymwave.com
MIXERS
DOUBLE -BALANCED
MIXERS
DOUBLE -BALANCED
THROUGH HOLE (TO-CAN)
0.01-125 DC-125 5.5/6 6/6.5 60/50 50/40 40/35 60/45 50/35 40/30 104 1 CHP-502
0.025-200 DC-200 5.5/6 6/7 65/55 55/45 45/35 60/50 45/35 35/30 104 1 CHP-512
0.1-500 DC-500 6/7 7/8 65/40 60/40 50/30 45/30 50/35 35/20 104 1 CHP-501
0.5-1000 DC-1000 5.5/7 7/8.5 70/40 45/35 40/25 60/40 40/30 30/20 104 1 CHP-503
5-200 DC-200 5.5/6 6/7 65/55 55/45 45/35 60/50 45/35 35/30 122 2 CHP-612
0.5-1000 DC-1000 5.5/7 7/8.5 70/40 45/35 40/25 60/40 40/30 30/20 122 2 CHP-603
20-1500 DC-1000 7.5/8.5 8/9 60/35 40/25 25/20 50/30 40/25 20/12 122 2 CHP-611
10-2000 5-600 7/8.5 7.5/9 60/35 40/25 40/20 50/30 30/20 25/15 122 2 CHP-609
800-2500 DC-400 --/-- 6.5/8.5 30/20 30/20 30/20 20/10 20/10 20/10 122 2 CHP-604
0.01-125 DC-125 5.5/6 6/6.5 60/50 50/40 40/35 60/45 50/35 40/30 110 3 CHK-702*
0.025-200 DC-200 5.5/6 6/7 65/55 55/45 45/35 60/50 45/35 35/30 110 3 CHK-712*
0.1-500 DC-500 6/7 7/8 65/40 60/40 50/30 45/30 50/35 35/20 110 3 CHK-701*
0.5-1000 DC-1000 5.5/7 7/8.5 70/40 45/35 40/25 60/40 40/30 30/20 110 3 CHK-703*
20-1500 DC-1000 7.5/8.5 8/9 60/35 40/25 25/20 50/30 40/25 20/12 110 3 CHK-711S
10-2000 5-600 7/8.5 7.5/9 60/35 40/25 40/20 50/30 30/20 25/15 110 3 CHK-709S
800-2500 DC-400 --/-- 6.5/8.5 30/20 30/20 30/20 20/10 20/10 20/10 110 3 CHK-704S
800-4200 DC-1000 --/-- 6/10 25/13 25/13 25/13 20/10 20/10 20/10 110 3 CHK-215S
COAXIAL
* Connector style: "B" = BNC, "T" = TNC,
"N" = Type N, "S" = SMA
NOTES:
1. 1dB Compression Point = +17 dBm (Typ)
2. IP3 (Input) = +26 dBm (Typ)
3. As IF frequency decrease below LF towards DC, conversion loss increases
up to 8 dB higher than maximum.
4. Maximum Input Power without damage = 500 mW ave. cw
LO = +23 dBm Super-High Dynamic Range
FREQUENCY RANGE
(MHz) CONVERSION
LOSS (dB)
RF/LO IF
XMB
TYP/MAX
FULL
BAND
TYP/MAX LB
TYP/MIN MB
TYP/MIN UB
TYP/MIN LB
TYP/MIN MB
TYP/MIN UB
TYP/MIN
LO-RF ISOLATION
(dB) LO-IF ISOLATION
(dB) PACKAGE MODEL
PIN
OUT
FREQUENCY RANGE
(MHz) CONVERSION
LOSS (dB)
RF/LO IF
XMB
TYP/MAX
FULL
BAND
TYP/MAX LB
TYP/MIN MB
TYP/MIN UB
TYP/MIN LB
TYP/MIN MB
TYP/MIN UB
TYP/MIN
LO-RF ISOLATION
(dB) LO-IF ISOLATION
(dB) PACKAGE MODEL
PIN
OUT
XMB= 2LF to HF/2
FULL BAND = LF to HF
LB= LF to 10LF
MB = 10LF to HF/2
UB= HF/2 to HF GND = Ground externally
For pin location and package outline drawings, see back pages.
RF LO IF GND CASE GND
#1 2 5 1 1 All Others All Others
#213244
#3 1 3 2 -- --
PIN-OUT T ABLE
122
104