Product Brochure Eaton ePDU G3 Managed Advanced power management and precision control The Eaton(R) ePDU(R) third generation (G3) Managed models build on Eaton's existing state-of-the-art ePDU G3 technology while offering new capabilities for rack power distribution in data centers and information technology (IT) applications. You now have comprehensive management and monitoring capabilities down to the outlet level. This new level of precision saves time, saves money and avoids risk, making the ePDU G3 Managed the gold standard in power management. Increasing level of control ePDU G3 key technology features Basic (BA) Metered Input (MI) Managed (MA) IEC outlet grip plug retention * * * Low-profile form factor * * * High 140F (60C) operating temperature * * * Color-coded outlet sections * * * Ease of installation * * * One percent billing grade accuracy * * Advanced LCD pixel display * * Daisy chain (share network connection/IP address) * * Hot-swap meter * * Phase and section metering * * Outlet switching * Turn off unused outlets * Remote site management * Measure power consumption at outlet level * Measure Level 3 power usage effectiveness (PUE) * Group reboot for A and B feed * Good Key applications ePDU G3 Managed models are available in a variety of plug and outlet configurations, including both 120 and 200240 volt configurations. The ePDU G3 Managed models give you advanced control of the rack environment, making it a perfect fit for a variety of applications. Better Best Remote office/branch office * Portfolio of 120V and lower power ratings (kVA) * Reboot devices without local IT staff assistance * Control unused outlets to prevent unauthorized use * LCD pixel menu display simplifies setup Enterprise data center * Up to 208V three phase 17kW for high density applications * Network monitoring of power usage and capacity at the outlet level * Save time by rebooting devices from the operations center * Measure power for Level 3 PUE 2 EATON Eaton ePDU G3 Grouped reboot for A and B feed When connecting multiple source input servers to an A and B feed power source, the daisy-chain capability allows you to group power supplies across the ePDU. As a result, all the power supplies are controlled with a single action, which saves time rebooting servers with two to six power supplies. Outlet switching Remotely control devices by powering on or off individual outlets. Save time and operating costs by rebooting machines from your control center without costly site visits. Turn off unused outlets Secure and protect your environment by easily turning off unused outlets. Avoid overloading your system from others plugging in unauthorized devices. Also consider closing access with an outlet cap. Typical server with multiple power inputs powered by two ePDUs Green LED signifies power on and red is power off to outlet Cap secures in place with cable tie Color-coded outlet sections Color-coded outlet sections match a corresponding circuit breaker to easily identify which one feeds corresponding outlets and prevent unbalanced loading that would unnecessarily trip a breaker. O is unlocked, + is grip engaged Outlet grip functionality Eaton's patent-pending IEC outlet grip secures plugs in place with a lever-actuated grip that's integrated into each outlet. Once the levers click into the grip position, the plugs are secured from accidental disconnect due to bumps or vibrations without the need for special power cords. EATON Eaton ePDU G3 3 One percent billing grade accuracy ePDU G3 provides one percent revenue-grade power monitoring for higher accuracy in department billing or colocation data centers. Effectively measure power usage to all outlets or individual outlets. Advanced LCD pixel display with hot-swap capability Eaton's new hot-swap eNMC (ePDU Network Management and Control) module can be replaced without the need to power down your rack. Increase uptime while enhancing serviceability and saving on unnecessary service calls. The menu-driven pixel display allows for easy setup and troubleshooting. Daisy chain four units from one IP address Eaton's new patented daisy-chain capability allows up to four ePDUs to share the same network connection and IP address. Unlike competitive rack PDUs that require a dedicated IP address for best performance, Eaton technology provides a 75-percent reduction in network infrastructure costs. Module being removed without removing power to the ePDU A and B power PDU sharing a network connection via daisy chain EATON Eaton ePDU G3 4 Increase effectiveness and reduce operating costs Remote site management Manage ePDU G3s using a web browser or via SNMP integration into monitoring or DCIM software. Simplify management by using the daisy-chain capability to manage up to four ePDU G3s with a single IP address. Avoid costly site visits by remotely rebooting and monitoring the site, allowing more time to manage other critical tasks Measure power consumption at the outlet level Acquire more accurate and detailed data by measuring power at the outlet level. Gain energy analysis at a deeper level to make informed decisions and assist with effectively deploying equipment. Compare efficiency between manufacturers and understand what drives power usage so you can make intelligent decisions to reduce power consumption. Make selection, advance to next screen From meter screen, select outlets... Make selection, advance to next screen From outlet screen, select specific outlet to view... View live power levels for selected outlet Measure Level 3 PUE PUE is an industry-wide accepted method to measure power effectiveness. Measuring at the outlet level removes upstream devices from the calculation to provide an accurate view of how effectively power is being used for the connected IT equipment. Data center managers typically prefer Level 3 PUE for the most accurate PUE calculation. PUE measurement Level 1: Basic Level 2: Intermediate Level 3: Advanced IT equipment energy UPS outputs PDU outputs IT equipment input Total facility energy Utility inputs Utility inputs Utility inputs Measurement intervals Monthly/weekly Daily/hourly Continuous (15 minutes or less) To obtain Level 3 PUE, you must take measurements at the IT equipment level in intervals of at least 15 minutes. Perform department and customer billing Metering at the outlet level provides customer-level energy tracking and turns power billing into a revenue stream that considers actual usage. Similarly, you can measure power usage per application and assign it to specific departments for budgeting purposes or to justify costs. Each outlet can be billed separately. eaton.com/ePDUG3 EATON Eaton ePDU G3 5 Ease of installation * Optional side mounting button locations to mount ePDU G3s at a 90-degree rotation in the rack, preventing interference with hot-swap fans and power supplies * Patented clip feet allow for multiple mounting methods * Mounting buttons come pre-installed to reduce installation time * Double-sided buttons accommodate different variations of metal thickness Eaton patented clip feet Mounting buttons come pre-installed ePDU G3 Managed selection guide Catalog number Input plug Cord (ft) Breaker Current (A) Max kW Output receptacles Dimensions (H x W x D, in) EMA112-10 5-15P 10 None 12 1.44 (16) 5-20R 66.5 X 2.05 X 2.56 EMA114-10 L5-20P (5-20P adapter) 10 None 16 1.92 (24) 5-20R 66.5 X 2.05 X 2.09 EMA108-10 L5-30P 10 (2) 20A 24 2.88 (24) 5-20R 66.5 x 2.05 x 2.56 EMA106-10 C20 (L6-20 adapter) 10 None 16 3.84 (7) C13, (1) C19 35.5 x 2.05 x 2.1 EMA107-10 L6-30P 10 (2) 20A 24 5.76 (20) C13, (4) C19 66.5 x 2.05 x 2.1 EMA324-10 L15-20P 10 (3) 20A 24 5.76 (18) C13, (6) C19 66.5 x 2.05 x 2.56 EMA325-10 L21-20P 10 (3) 20A 24 5.76 (18) C13, (6) C19 66.5 x 2.05 x 2.56 EMA339-10 L15-20P 10 (3) 20A 16 5.76 (21) C13, (3) C19 66.5 x 2.05 x 2.09 EMA340-10 L21-20P 10 (3) 20A 16 5.76 (21) C13, (3) C19 66.5 x 2.05 x 2.09 EMA326-10 L15-30P 10 (3) 20A 24 8.64 (18) C13, (6) C19 66.5 x 2.05 x 2.56 EMA327-10 L21-30P 10 (3) 20A 24 8.64 (18) C13, (6) C19 66.5 x 2.05 x 2.56 EMA333-10 L21-30P 10 (3) 20A 24 8.64 (21) C13, (6) C19, (1) 5-20R 66.5 X 2.05 X 2.56 EMA341-10 L15-30P 10 (3) 20A 24 8.64 (21) C13, (3) C19 66.5 x 2.05 x 2.09 EMA342-10 L21-30P 10 (3) 20A 24 8.64 (21) C13, (3) C19 66.5 x 2.05 x 2.09 EMA328-10 CS8365 10 (3) 20A 35 12.48 (18) C13, (6) C19 66.5 x 2.05 x 2.56 EMA343-10 CS8365 10 (3) 20A 35 12.48 (21) C13, (3) C19 66.5 x 2.05 x 2.09 EMA329-06 CS8365 6 (6) 20A 40 14.4 (12) C13, (12) C19 66.5 x 2.05 x 2.56 EMA330-06 IEC60309 460P9W 6 (6) 20A 48 17.3 (12) C13, (12) C19 66.5 x 2.05 x 2.56 ePDU G3 accessories Part Number Description EMP001 Environmental monitoring probe 010-0029 2-foot C13 to C14 jumper cord 010-0028 4-foot C13 to C14 jumper cord 010-0027 6-foot C13 to C14 jumper cord 010-0025 8-foot C13 to C14 jumper cord 035-0113 C13 outlet cap 035-0119 C19 outlet cap Environmental monitoring The optional environmental monitoring probe connects to the serial port and enables you to collect temperature and humidity readings in the rack environment to monitor environmental data remotely. You can also monitor the status of two contact closure devices, such as door switches. Part Number EMP001 Eaton Electrical Sector 1000 Eaton Boulevard Cleveland, OH 44122 USA Eaton.com (c) 2015 Eaton All Rights Reserved Printed in USA BR155006EN October 2014 Eaton and ePDU are registered trademarks of Eaton. All other trademarks are property of their respective owners. For more information on the new G3 platform, visit Eaton.com/ePDUG3