Page 2/5
Data Sheet P/N
ASP044xx
xx=number of poles
2017/05/05
SP044xxVBNN
Technical Data
General Data
min. number of poles 2
max. number of poles 12
Insulating material class CTI 400
clearance/creepage dist. 2.6 mm
protection category IP 20
Overvoltage category III III II
Pollution degree 3 2 2
Rated voltage 32.0 V 200.0 V 200.0 V
Rated test voltage 1.5 kV 1.5 kV 1.5 kV
Connection data
Rated wiring solid wire 0.08 - 1.5 mm² / AWG 28 - 16
Rated wiring stranded wire 0.08 - 1.5 mm² / AWG 28 - 16
Approvals
V / A 150 / 10
10 A / 130 V / 2.5 kV / 3 / IEC 61984 /
0.08 - 1.5 mm²
Material
insulating material PA46
flammability class V0
spring material Spring steel
contact material CuSn
Glow-Wire Flammability GWFI -
Glow-Wire Flammability GWIT -
contact surface Sn
Climatic properties
upper limit temperature 105 °C
lower limit temperature -40 °C
General
Tolerance ISO 2768 -mH