Technical Datasheet Catalogue Page 1SNK 161 020 D0201 1SNK 161 020 S0201 ZS35-PE Screw Clamp Terminal Block 35 mm Ground 0 AWG Features and Benefits 16 mm 0.630 in Spacing Reliable electrical and mechanical contact with the rail that exceeds the requirements of IEC 60947-7-2 terminal block standard. 63.3 2.49" 59 2.32" 34 1.34" 3D CAD outline drawings available on "Control Product 3D" portal Ordering Details Type Order Code EAN Code Pack(ing) Weight g (1 pce) Green-Yellow ZS35-PE 1SNK 516 150 R0000 3472595161508 20 81.80 Declarations and Certificates Document Part Number CE UE Directive 1SND 225 094 C1003 CB Third Party Certificate 1SND 161 027 A0200 RoHS 1SND 230 491 F0203 Atex Declaration 1SND 225 085 C1003 RoHS 1 General Information The following information must be strictly adhered to in order to guarantee the terminal block electrical, mechanical and environmental performance. Protection IP 20 Rail DIN3-TH35 Wire stripping length 17 mm NEMA 1 0.669 in Screw clamp Screw rail contact (Maximum value) Flat screwdriver Operating tool Torque 6.5 mm 0.256 in 5.5 mm 0.217 in 2.65 Nm 23.5 lb.in 1.6 Nm 14.2 lb.in 0.15 Nm 1.33 lb.in 0.15 Nm 1.33 lb.in Mechanical endurance of disconnect system Material Specifications Polyamide 600 V UL94 V0 NF F 16 101 I2F2 Needle flame test IEC 60695-11-5 Compliant Insulating material IRC Flammability Connecting capacity per clamp 6-35 mm 6-35 mm 1 Rigid conductor 1 Flexible conductor without ferrule 1 Flexible conductor with ferrule 14 mm Ferrule maximum outer diameter 10-0 AWG 10-0 AWG 0.551 in Multi Connecting capacity per clamp 2 Rigid conductors 2 Flexible conductors without ferrule 2 Flexible conductors with twin ferrule Don't mix solid and flexible conductors in the same clamp Don't mix solid or flexible conductors of different sizes in the same clamp The "Connecting capacity with ferrule " data is guaranteed with ABB crimping tool PS-3 Cross section Rated cross section Maximum Cross section Gauge Manufacturer data 35 mm 35 mm Manufacturer data 0 AWG 0 AWG A9 / 10 mm / 0.394 in / IEC 60947-7-1 Electrical characteristics Current Rated current Field and factory wiring Cat.2 Factory wiring Cat.1 Rated short-time withstand current 1 s (Icw) Short-time withstand current 0.5 s 5s 10 s 30 s 1 mn Rated short circuit withstand Max. current (45 temperature increase) / Max. cross section (mm) Maximum short circuit current (1s) 2 IEC 60947-7-1 UL 1059 UL 1059 CSA-C-22.2 n 158 4200 A Manufacturer data Manufacturer data Manufacturer data Manufacturer data Manufacturer data CSA-C-22.2 n 158 Manufacturer data Manufacturer data 4200 A 35 mm Short Circuit Current Rating (SCCR) SA UL 1059 supplement SCCR UL 1059 With the following configurations: Maximum voltage Suitable conductor wire range Fuse rating Fuse designation Fuse manufacturer name Fuse type Short circuit current Voltage Rated voltage Rated voltage Use Group Rated voltage Rated voltage Ex e IEC 60947-1 UL 1059 UL 1059 C CSA-C-22.2 n 158 IEC/EN 60079-11 8000 V 2200 V IEC 60947-1 3 IEC 60947-1 III Rated impulse withstand voltage Dielectric test voltage Pollution degree Overvoltage category Dissipated power IEC Maximum dissipated power at rated current Rated power dissipation at an ambient temperature of 23 C - IEC 60947-7-3 Overload and short-circuit protection Separate arrangement Exclusive short-circuit protection Separate arrangement 1 fuse and 4 feed-through blocks Overload and short-circuit protection Compound arrangement Exclusive short-circuit protection Compound arrangement 5 fuse blocks Temperature range Ambient temperature min/max Storage Installing Service -55 +110 C -5 +40 C IEC 60068-2-1 -55 +110 C EN 60079-7 -55 +85 C -67 +230 F -23 +104 F -67 +230 F Current Derating curve for continuous service temperature 3 Environmental Characteristics Additional climatic tests Dry heat Conditions Cyclic damp heat Conditions Cold Conditions Z/ABDM climatic sequence Conditions IEC 60068-2-2 Temperature Duration of test IEC 60068-2-30 Temperature Number of cycles IEC 60068-2-1 Temperature Duration of test IEC 60068-2-61 Dry heat Duration of test / Temperature Cyclic damp heat Number of cycles / Temperature Cold Duration of test / Temperature Compliant +100 C 96 h Compliant +55 C 2 Compliant -40 C 96 h Compliant 16 h +85 C 1 +55 C 2h -25 C Corrosion Salt mist Conditions SO2 Conditions Sulfur dioxide Conditions Hydrogen sulfur Conditions Flowing mixed gas corrosion test Conditions IEC 60068-2-11 Duration of test Concentration ISO 6988 Duration of test Concentration IEC 60068-2-42 Duration of test IEC 60068-2-43 Duration of test IEC 60068-2-60 Number of the test method Duration of test Compliant 96 h 5% Compliant 48 h 0.2 dm IEC 60068-2-6 Frequency range Number of cycles Amplitude Acceleration IEC 60068-2-64 Duration of test Frequency range Acceleration Compliant 10-55 Hz 10 Vibrations Vibrations Conditions Ramdom vibrations and climatic sequence Conditions Climatic cycles Step 1 -> Temperature / Duration of test Step 2 -> Temperature / Duration of test Temperature variation per minute 4 10 m/s ZS35-PE Terminal Block Accessories Compatibility Description Type Order Code Pack(ing) Weight 1 End Stops BAZH1 1SNK 900 102 R0000 2 Circuit Separators CS-R1 3 Protecting Covers CO 4 Protecting Cover Kits 5 Terminal Block Markers Technical Datasheet pieces g (1 pce) PDF 20 23.90 1SNK 160 026 D0201 1SNK 900 103 R0000 20 5.20 1SNK 160 018 D0201 1SNK 900 604 R0000 1 300.00 1SNK 160 020 D0201 KCO 1SNK 900 624 R0000 1 47,8 1SNK 160 028 D0201 MC812 1SNK 160 000 R0000 22 0.09 1SNK 160 009 D0201 UMH 1SNK 900 611 R0000 10 0.20 1SNK 160 001 D0201 PROCAP8 1SNK 900 613 R0000 20 1.00 1SNK 160 013 D0201 SAT8 1SNK 900 616 R0000 5 6.00 1SNK 160 013 D0201 5