Honeywell Pressure Switches High Pressure: HP Series, HE Series Factory set 150 psi to 4500 psi [10,34 bar to 310,26 bar] Low Pressure: LP Series, LE Series Factory set or field adjustable 3.5 psi to 150 psi [0,24 bar to 10,34 bar] Datasheet Honeywell Pressure Switches HP Series, HE Series, LP Series, LE Series Honeywell Pressure Switches are durable, reliable electromechanical gauge pressure on/off switches that are available with either single pole single throw (SPST) normally open or normally closed circuitry, or single pole double throw (SPDT) circuitry. Their IP67 environmental sealing and high proof pressure and burst pressure ratings allow for use in many rugged applications that require the making or breaking of an electrical connection in response to a pressure change of the system media. The media (gas or liquid) pressure is applied via the port of the switch to a diaphragm or sealed piston. A precompressed spring on the other side of the sealed piston or diaphragm controls the set-point pressure. If the force resulting from the pressure is greater than the load on the spring, the electrical contacts within the switch will change state. If the contacts are normally open when no pressure is applied, they close on increasing pressure when the set point is reached. On decreasing pressure, the contacts will open again at a pressure somewhat less than the set switching point. The difference between the activation point on increasing pressure and the deactivation point on decreasing pressure is called hysteresis. The set point pressure for the switch can be configured such that the switch will actuate on increasing or decreasing system pressure. Features Potential Applications * Life cycle rating: up to 2 million TRANSPORTATION * IP67 sealing rating * Agricultural machinery * Operating temperature range: -40 C to 120 C * Heavy duty construction machinery [-40 F to 248 F] * Heavy duty trucks Proof pressure: 10000 psi [689 bar] (High Pressure), * Lawn & garden 500 psi [34,47 bar] (Low Pressure) * Marine vessels Burst pressure: 20000 psi [1379 bar] (High Pressure), * Material handling machinery 750 psi for 3.5 psi to 22 psi, 1250 psi > 22 psi (Low Pressure) * Railway * * * Hysteresis option (HP, HE, and LP Series only) * Variety of pressure ports and electrical terminations INDUSTRIAL * Pressure switching set point range: Factory set 150 psi to * CNC machines 4500 psi [10,34 bar to 310,26 bar] (High Pressure) or factory * Compressors, boilers set or field adjustable 3.5 psi to 150 psi [0,24 bar to 10,34 bar] * Fracking equipment (Low Pressure) * Food & beverage equipment Switching point accuracy: up to 2 % * Generators * HVAC/R equipment * Mud pumps * Pneumatic equipment * Presses and punches * Pressure washers * Trash compactors * Water jet cutting machines * Water pumps * LONG LIFE * HIGH PRODUCTIVITY * RELIABLE SWITCHING 2 sensing.honeywell.com Honeywell Pressure Switches Table 2. Specifications Characteristic Product length (connector version AMP Super Seal) HP Series HE Series LP Series LE Series see page 5 see page 5 see page 6 see page 6 Product length (blade) Product length (wire out) Hex size see page 5 see page 5 see page 6 see page 6 see page 5 see page 5 see page 6 see page 6 27 mm 27 mm 27 mm 27 mm Ease of installation box spanner box spanner box spanner box spanner Snap-action switch yes yes yes no Set point1 range 150 psi to 4500 psi 150 psi to 4500 psi 3.5 psi to 150 psi 3.5 psi to 150 psi Set point ranges 6 6 4 4 Set point accuracy @ 25 C (before test) 150 psi to 500 psi (5 %) 500 psi to 4000 psi (3.5 %) >4000 psi (2 % [up to 2 %]) 150 psi to 1000 psi (14%) for 3.5 psi to 10 psi (1 psi), for 3.5 psi to 10 psi (1 psi), 1000 psi to 2000 psi (12 %) for >10 psi to 50 psi (3 psi), for >10 psi to 50 psi (3 psi), 2000 psi to 4000 psi (11 %) for >50 psi to 100 psi (7 psi), for >50 psi to 100 psi (7 psi), >4000 psi (10 % [up to 10 %]) for >100 psi to 150 psi (10 psi) for >100 psi to 150 psi (10 psi) Average deadband n/a n/a n/a for 3.5 psi to 10 psi (2.8 psi), for >10 psi to 50 psi (14 psi), for >50 psi to 100 psi (38 psi), for >100 psi to 150 psi (40 psi) Operating pressure2 5,000 psi max. 5,000 psi max. 250 psi max. 250 psi max. 10,000 psi 10,000 psi 500 psi 500 psi 5 % to 55 % (based on set point range) 3 % to 65 % (based on set point range) 3 % to 50 % (based on set point range) n/a 750 psi for set points 3.5 psi to 22 psi, 1250 psi for set points > 22 psi 7.5 mA to 3 A, 24 Vdc and 250 Vac Proof pressure 3 Hysteresis 20,000 psi 20,000 psi 5 A at 250 Vac 5 A at 24 Vdc 5 A at 250 Vac 3 A at 24 Vdc 750 psi for set points 3.5 psi to 22 psi, 1250 psi for set points > 22 psi 7.5 mA to 5 A, 24 Vdc and 250 Vac 5 A at 115 Vac (SX rating) 3 A at 28 Vdc n/a 1 A at 28 Vdc n/a Temperature rating -40 C to 120 C [-40 F to 248 F] -40 C to 85 C [-40 F to 185 F] -40 C to 120 C [-40 F to 248 F] -40 C to 120 C [-40 F to 248 F] Media connection multiple ports available multiple ports available Burst pressure 4 Current rating (resistive) Current rating (inductive) Pressure ports M14 x 1.5, M18 x 1.5, 1/2-20 UNF, 9/16-18 UNF, 3/4-16 UNF, 7/8-14 UNF multiple ports available multiple ports available 1/4-18 NPT,1/8-27 NPT, 1/2-20 UNF,1/8-27 PTF, M12 x 1.5, M14 x 1.5, 9/16-18 UNF, 3/4-16 UNF, G1/8 BSPP, 7/16-20 UNF, R1/8 BSPT, M10 x 1.0, R1/2 BSPT, G1/4 BSPP, R1/4 BSPT 1/4-18 NPT,1/8-27 NPT, 1/2-20 UNF, 1/8-27 PTF, M12 x 1.5, M14 x 1.5, 9/16-18 UNF, 3/4-16 UNF, G1/8 BSPP, 7/16-20 UNF, R1/8 BSPT, M10 x 1.0, R1/2 BSPT, G1/4 BSPP, R1/4 BSPT sensing.honeywell.com 3 HP Series, HE Series, LP Series, LE Series Table 2. Specifications (continued) Characteristic HP Series HE Series LP Series LE Series AA = Spade Terminals BA = Screw Terminals CA = Deutsch DT04-3P-E005 (3-Pin Connector) DA = Amp Super Seal 1.5 - 282105-1 (3-Pin Connector) EA = 10-inch Cable, 18 AWG (Wire Out, No Connector) FA = 10-inch Cable w/Deutsch DT04-3P-E005 (3-Pin Connector) (16 AWG)* GA = 10-inch Cable w/Amp Super Seal 1.5 - 282105-1 (3-Pin Connector) (18 AWG)* HA = 10-inch Cable w/Metripack 280 Delphi 15300002 (2-Pin Connector) (18 AWG)* JA = 10-inch Cable w/Din43650-C (3-Pin Connector) (18 AWG)* KA = 10-inch Cable w/M12x1 (Brad Harrison Micro) - 21032121306 Harting P/N (3-Pin Connector) (18 AWG)* LA = 10-inch Cable w/Packard Weatherpack Male Terminal - 12020827 (3-Pin Connector) (18 AWG) MA = 10-inch Cable w/Deutsch DT04-2P-E005 (2-Pin Connector) (18 AWG) NA = 3-inch Cable w/Packard 2P Tower Connector - 12015792 (2-Pin Connector) (18 AWG) PA = 2.75-inch Cable w/Packard 2P Shroud Connector - 12010973 (2-Pin Connector) (18 AWG) RA = 4-inch Cable w/Packard 2P Shroud Connector - 12010973 (2-Pin Connector) (16 AWG) SA = 5.5-inch Cable w/ITT Cannon 2P Sure-Seal Circular Connector - SS2R-120-1804-000 (2-Pin Connector) (18 AWG) TA = 8.5-inch Cable w/ITT Cannon 3P Sure-Seal Circular Connector - SS3R-120-8551-001 (3-Pin Connector) (16 AWG)* UA = 10-inch Cable - Vacuum Impregnated w/Deutsch DT06-3S-EP06 (3-Socket Connector) (16 AWG)* VA = 10-inch Cable - Vacuum Impregnated w/Deutsch DT04-3P-E005 (3-Pin Connector) (16 AWG)* WA = 4.5-inch Cable w/Blade Terminals 6,3 mm x 0,8 mm (16 AWG)* YA = 6-inch Cable w/Amp Super Seal 1.5 - 282104-1 (2-Pin Connector) (18 AWG)* ZA = 10-inch Cable w/Deutsch DT06-2S-CE06 (2-Socket Connector) (18 AWG) AB = Deutsch DT04-2P-E005 (2-Pin Connector)** BB = 10-inch Cable w/Metripack 150 Delphi 12129615 (3-Pin Connector) (18 AWG)* DB = 10-inch Cable w/AMP 2,5 mm System Series Connector 1-967402-1 (18 AWG)* EB = 4.5-inch Cable w/Packard Shroud Connector 12015792 (2-Pin Connector) (18 AWG) FB = 10-inch Cable w/Metripack 150 Delphi 12052641 (2-Pin Connector) (18 AWG) GB = 10-inch Cable w/Deutsch Plug HD 16-3 96S (3-Pin Connector) (16 AWG)* Termination Circuit forms5 Life Agency approvals (special use switches) Agency approvals (other) Field adjustability6 Spike dampening Ingress protection SPDT, SPST - NO/NC SPDT, SPST - NO/NC SPDT, SPST - NO/NC SPDT, SPST - NO/NC 2 million 1 million 2 million 1 million UL pending UL pending UL pending UL pending CE CE CE pending CE pending no no yes yes yes yes no no IP67 10 Hz to 2000 Hz at 15 g 20 min/sweep 500 m/sec2, 11 mSEC, 100 shocks / axis IP67 10 Hz to 2000 Hz at 15 g 20 min/sweep 500 m/sec2, 11 mSEC, 100 shocks / axis n/a IP67 IP67 10 Hz to 2000 Hz at 15 g 20 min/sweep 10 Hz to 2000 Hz at 15 g 20 min/sweep 500 m/sec2, 11 mSEC 500 m/sec2, 11 mSEC n/a Kapton(R) (Teflon(R) coated), Tefzel(R) Kapton(R) (Teflon(R) coated), Tefzel(R) nitrile or EPDM O-ring, steel piston nitrile or EPDM O-ring, steel piston n/a n/a Weight 0,133 g [4.7 oz] 0,133 g [4.7 oz] 0,058 kg [2.0 oz] 0,053 kg [1.9 oz] Contacts silver / gold inlay silver gold plated gold plated zinc plating zinc plating zinc plating zinc plating 7 Vibration resistance Shock resistance Wetted part (diaphragm) Wetted part (piston) Product finish Set point: Point at which switch actuates or de-actuates 2 Operating pressure: Maximum normal system operating pressure (above set point) 3 Proof pressure: Maximum pressure that the switch can handle while it maintains set point accuracy. Intermittent spikes to this level are acceptable. 4 Burst pressure: Point of complete switch failure 5 SPST: Single pole, single throw. SPDT: Single pole, double throw. NO: Normally open. NC: Normally closed. 6 Field adjustability only available with AA, BA, CA, and DA (SPST only) terminations. 7 IP00 for AA and BA terminations. *These connectors are designed for dual circuit (SPDT) by default. They can be used for single-circuit applications (SPNC/SPNO) by making suitable connections. Refer to wiring diagram. **Option AB is available only for LP and LE Series. 1 4 sensing.honeywell.com Honeywell Pressure Switches DIMENSIONS - HIGH PRESSURE: HP SERIES, HE SERIES Figure 1. AMP Superseal 1.5 61,64 mm [2.427 in] Figure 6. High Pressure Port Dimensions 1/2-20 UNF 20,02 mm max. [0.788 in] max. 27 mm hex A/F .557 .433 .081 1/2 - 20UNF 2A 9/16-18 UNF Female Connector Part Number (included): C-282105 Male Mating Connector (customer provided): C-282087 IP Rating: IP67 .518 Figure 2. Deutsch 27 mm hex A/F O 0.432 +0.002 -0.003 (bottom view) 81,66 mm [3.215 in] (top view) 61,64 mm [2.427 in] 21,16 mm max. [0.833 in] max. .472 .088 9/16 - 18UNF 2A O 0.482 +0.002 -0.003 3/14-16 UNF (top view) (bottom view) 82,8 mm [3.26 in] Female Connector Part Number (included): DT04-3P Male Mating Connector (customer provided): DT06-3S IP Rating: IP67 .100 .551 3/4-16UNF 2A O 0.660 +0.002 -0.003 Figure 3. Spade Terminal 27 mm hex A/F .439 61,64 mm [2.427 in] 7/8-14 UNF 14,43 mm [0.568 in] max. .490 .500 76,08 mm [2.995 in] (top view) .112 7/8-14 UNF O 0.776 +0.002 -0.003 (bottom view) M14 x 1.5 Figure 4. Screw Terminal 61,64 mm [2.427 in] 27 mm hex A/F 12,65 mm [0.498 in] max. .118 .557 .433 .098 .004 M14 X 1.5 O 0.461 +0.002 -0.003 O.740 74,3 mm [2.925 in] (top view) (bottom view) Figure 5. Cable 61,64 mm [2.427 in] 27 mm hex A/F M18 x 1.5 .098 .004 19,51 mm max. [0.768 in] max. .439 .551 .118 M18 X 1.5 O 0.618 +0.002 -0.003 O.937 (top view) 81,15 mm [3.195 in] (bottom view) IP Rating: IP67 sensing.honeywell.com 5 HP Series, HE Series, LP Series, LE Series DIMENSIONS - LOW PRESSURE: LP SERIES, LE SERIES Figure 7. AMP Superseal 1.5 (bottom view) Figure 13. Low Pressure Port Dimensions H H 58,93 mm max. [2.32 in] max. OD OD Female connector part number (included): C-282105 Male mating connector (customer provided): C-282087 IP rating: IP67 Figure 8. Deutsch 3-pin H (bottom view) 57,66 mm max. [2.27 in] max. Female connector part number (included): DT04-3P Male mating connector (customer provided): DT06-3S IP rating: IP67 Table 3. Low Pressure Port Diameters and Heights Figure 9. Deutsch 2-pin (bottom view) Port 58,93 mm max. [2.32 in] max. Female connector part number (included): DT04-2P Male mating connector (customer provided): DT06-2S IP rating: IP67 Figure 10. Wire out (bottom view) IP rating: IP67 42,16 mm max. [1.66 in] max. Figure 11. Spade terminal (bottom view) 33,02 mm max. [1.30 in] max. Figure 12. Screw terminal (bottom view) 6 sensing.honeywell.com OD 33,02 mm max. [1.30 in] max. Diameter "OD" Height "H" R 1/2 BSPT 21,34 mm [0.840 in] 17,09 mm [0.673 in] R 1/4 BSPT 13,46 mm [0.530 in] 13,74 mm [0.541 in] R 1/8 BSPT 9,96 mm [0.392 in] 10,24 mm [0.403 in] 1/8-27 PTF 10,34 mm [0.407 in] 9,24 mm [0.364 in] 1/4-18 NPT 13,72 mm [0.540 in] 17,63 mm [0.694 in] 1/8-27 NPT 10,29 mm [0.405 in] 12,497 mm [0.492 in] G 1/4 BSPP 11,1 mm [0.437 in] 11,20 mm [0.441 in] G 1/8 BSPP 8,28 mm [0.326 in] 7,59 mm [0.299 in] 7/16-20 UNF 9,25 mm [0.364 in] 9,09 mm [0.358 in] 9/16-18 UNF 12,24 mm [0.482 in] 10,00 mm[0.394 in] 1/2-20 UNF 10,85 mm [0.427 in] 9,09 mm [0.358 in] M14 x 1.5 11,71 mm [0.461 in] 10,998 mm [0.433 in] M12 x 1.5 9,70 mm [0.382 in] 10,998 mm [0.433 in] M10 x 1.0 8,41 mm [0.331 in] 8,51 mm [0.335 in] Honeywell Pressure Switches NOMENCLATURE: HIGH PRESSURE For example, HPR05500PFNSPAAA01 defines a high pressure switch, rising factory set, non-adjustable set point, 550 psi set point, psig, sealed gage pressure unit, M14 x 1.5 port type, SPST-NO silver contacts output, cold-rolled steel base, glycol-based fluid (EPDM) actuation/application, spade terminal connectors, standard switch, individually boxed units. HP R 05500 P F N S P AA A 01 Series Set Point Pressure Set Point Pressure Unit Port Type Output Base Actuation/ Application Connector Type Options Packaging Options HP Series, HE Series High Pressure Switch R Rising factory set, non-adjustable 10,34 bar to 310,26 bar [150 psi to 4500 psi] P psig, sealed gage C 1/2-20 UNF* N SPST-NO, silver contacts S Cold-rolled steel N Petroleum-based hydraulic fluid (Nitrile) AA 1/4 in Spade Terminals A Standard switch 01 Individually boxed units F Falling factory set, non-adjustable NOTE: Pressure set point is always five digits. B bar, sealed gage F M14 x 1.5** C SPST-NC, silver contacts V Stainless steel P Glycol-based fluid (EPDM) BA Screw Terminals B With 3 shrink sleeve packed in 15 boxes bulk packaging G 9/16-18 UNF** D SPDT-NO/NC, silver contacts CA Deutsch DT04-3P-E005 (3-Pin Connector) C With shrink sleeve (plastic coating) packed in 20 boxes bulk packaging H 3/4-16 UNF H NO, gold inlay contacts DA Amp Super Seal 1.5 282105-1 (3-Pin Connector) D With shrink sleeve (acrylic coating) 25 bulk packaging K M18 x 1.5 J NC, gold inlay contacts EA 10-inch Cable, 18 AWG (Wire Out, No Connector) E With 1/8 watt resistor between terms. in 50 parts bulk packaging N 7/8-14 UNF K SPDT(NO/NC), gold inlay contacts FA 10-inch Cable w/Deutsch DT04-3P-E005 (3-Pin Connector) (16 AWG)* F 304,8 mm [12 in] total wire length GA 10-inch Cable w/Amp Super Seal 1.5 - 282105-1 (3-Pin Connector) (18 AWG)* G With conduit sleeve HA 10-inch Cable w/Metripack 280 Delphi 15300002 (2-Pin Connector) (18 AWG)* JA 10-inch Cable w/ Din43650-C (3-Pin Connector) (18 AWG)* KA 10-inch Cable w/M12x1 (Brad Harrison Micro) 21032121306 Harting P/N (3-Pin Connector) (18 AWG)* LA 10-inch Cable w/Packard Weatherpack Male Terminal 12020827 (3-Pin Connector) (18 AWG) MA 10-inch Cable w/Deutsch DT04-2P-E005 (2-Pin Connector) (18 AWG) NA 3-inch Cable w/Packard 2P Tower Connector 12015792 (2-Pin Connector) (18 AWG) PA 2.75-inch Cable w/Packard 2P Shroud Connector 12010973 (2-Pin Connector) (18 AWG) RA 4-inch Cable w/Packard 2P Shroud Connector 12010973 (2-Pin Connector) (16 AWG) SA 5.5-inch Cable w/ITT Cannon 2P Sure-Seal Circular Connector SS2R-120-1804-000 (2-Pin Connector) (18 AWG) For bar, the set point value will be multiplied by 100 and entered in the listing. For example, 15,45 Bar is noted as 01545. This allows for 2 decimal places. For psi, the set point value will be multiplied by 10 and entered in the listing. For example, 245.5 psi is noted as 02455. This allows for 1 decimal place. * not applicable for 10.3 bar to 65,5 bar [150 psi to 950 psi] ** not applicable for 10.3 bar to 24,1 bar [150 psi to 350 psi] TA UA 25 individual 50 individual 25 units in 50 individual 8.5-inch Cable w/ITT Cannon 3P Sure-Seal Circular Connector SS3R-120-8551-001 (3-Pin Connector) (16 AWG)* 10-inch Cable - Vacuum Impregnated w/Deutsch DT06-3S-EP06 (3-Socket Connector) (16 AWG)* VA 10-inch Cable - Vacuum Impregnated w/Deutsch DT04-3P-E005 (3-Pin Connector) (16 AWG)* WA 4.5-inch Cable w/ 1/4 in Spade Terminals 6,3 mm x 0,8 mm (16 AWG)* YA 6-inch Cable w/Amp Super Seal 1.5 - 282104-1 (2-Pin Connector) (18 AWG)* ZA 10-inch Cable w/Deutsch DT06-2S-CE06 (2-Socket Connector) (18 AWG) AB Deutsch DT04-2P-E005 (2-Pin Connector)** BB 10-inch Cable w/Metripack 150 Delphi 12129615 (3-Pin Connector) (18 AWG)* DB 10-inch Cable w/AMP 2,5 mm System Series Connector 1-967402-1 (18 AWG)* EB 4.5-inch Cable w/Packard Shroud Connector 12015792 (2-Pin Connector) (18 AWG) FB 10-inch Cable w/Metripack 150 Delphi 12052641 (2-Pin Connector) (18 AWG) GB 10-inch Cable w/Deutsch Plug HD 16-3 96S (3-Pin Connector) (16 AWG)* *These connectors are designed for dual circuit (SPDT) by default. They can be used for single-circuit applications (SPNC/SPNO) by making suitable connections. Refer to wiring diagram. **Option AB is available only for LP and LE Series. sensing.honeywell.com 7 HP Series, HE Series, LP Series, LE Series NOMENCLATURE: LOW PRESSURE For example, LPR00550PFPVKAAA01 defines a low pressure switch, rising factory set, non-adjustable set point, 55 psi set point, psig, sealed gage pressure unit, M14 x 1.5 port type, SPST-NO gold-plated contacts output, stainless steel base, Kapton(R) diaphragm (Teflon(R) coated), Nitrile O-ring actuation/application, spade terminal connectors, standard switch, individually boxed units. LP R 00550 P F P V K AA A 01 Series Set Point Pressure Set Point Pressure Unit Port Type Output Base Actuation/ Application Connector Type Options Packaging Options LP Series, LE Series R Low F Pressure Switch T C Rising factory set, non-adjustable Falling factory set, non-adjustable Rising, field adjustable* Falling, field adjustable* * Field adjustable option is only available for: 1. Blade and screw terminations 2. Deutsch DT04-3P (SPDT, SPNO, SPNC) 3. Amp Superseal 1.5 (3-pin) (SPNO & SPNC) 0,24 bar to 10,34 bar [3.5 psi to 150 psi] NOTE: Pressure set point is always five digits. For bar, the set point value will be multiplied by 100 and entered in the listing. For example, 15,45 Bar is noted as 01545. This allows for 2 decimal places. For psi, the set point value will be multiplied by 10 and entered in the listing. For example, 245.5 psi is noted as 02455. This allows for 1 decimal place. P psig, sealed gage A 1/4-18 NPT P SPST-NO, gold-plated contacts B Brass B bar, sealed gage B 1/8-27 NPT M SPST-NC, gold-plated contacts N Cold-rolled steel M bar, true gage C 1/2-20 UNF Y SPDT-NO/NC, gold-plated contacts V Stainless steel T psig, true gage Blade and screw electrical terminations are available with only the the true gage option. True gage option is available only up to 20 psig set point for integral connectors and wire out electrical terminations. D F M14 x 1.5 AA 1/4 in Spade Terminals A Standard switch 01 Individually boxed units H Kapton diaphragm (Teflon coated), EPDM O-ring2 BA Screw Terminals B With 3 shrink sleeve packed in 15 boxes bulk packaging T Tefzel diaphragm, Nitrile O-ring3 CA Deutsch DT04-3P-E005 (3-Pin Connector) C With shrink sleeve (plastic coating) units in 20 150 bulk packaging DA Amp Super Seal 1.5 282105-1 (3-Pin Connector) D With shrink sleeve (acrylic coating) EA 10-inch Cable, 18 AWG (Wire Out, No Connector) E With 1/8 watt resistor between terms. FA 10-inch Cable w/Deutsch DT04-3P-E005 (3-Pin Connector) (16 AWG)* F 304,8 mm [12 in] total wire length GA 10-inch Cable w/Amp Super Seal 1.5 - 282105-1 (3-Pin Connector) (18 AWG)* G With conduit sleeve R With port neck o-ring Tefzel diaphragm, EPDM O-ring4 Air, Petroleum-based hydraulic fluid, engine oil 2 Glycol-based fluid 3 For high temperature fluid media 4 For high temperature fluid media, glycol-based fluid 1 M12 x 1.5 Kapton diaphragm (Teflon coated), Nitrile O-ring1 U 1/8-27 PTF E K G 9/16-18 UNF H 3/4-16 UNF HA 10-inch Cable w/Metripack 280 Delphi 15300002 (2-Pin Connector) (18 AWG)* J G1/8 BSPP JA 10-inch Cable w/ Din43650-C (3-Pin Connector) (18 AWG)* M 7/16-20 UNF KA 10-inch Cable w/M12x1 (Brad Harrison Micro) 21032121306 Harting P/N (3-Pin Connector) (18 AWG)* R R1/8 BSPT LA T 10-inch Cable w/Packard Weatherpack Male Terminal 12020827 (3-Pin Connector) (18 AWG) M10 x 1.0 V MA 10-inch Cable w/Deutsch DT04-2P-E005 (2-Pin Connector) (18 AWG) R1/2 BSPT NA 3-inch Cable w/Packard 2P Tower Connector 12015792 (2-Pin Connector) (18 AWG) PA 2.75-inch Cable w/Packard 2P Shroud Connector 12010973 (2-Pin Connector) (18 AWG) RA 4-inch Cable w/Packard 2P Shroud Connector 12010973 (2-Pin Connector) (16 AWG) SA 5.5-inch Cable w/ITT Cannon 2P Sure-Seal Circular Connector SS2R-120-1804-000 (2-Pin Connector) (18 AWG) Y G1/4 BSPP Z R1/4 BSPT TA UA 8.5-inch Cable w/ITT Cannon 3P Sure-Seal Circular Connector SS3R-120-8551-001 (3-Pin Connector) (16 AWG)* 10-inch Cable - Vacuum Impregnated w/Deutsch DT06-3S-EP06 (3-Socket Connector) (16 AWG)* VA 10-inch Cable - Vacuum Impregnated w/Deutsch DT04-3P-E005 (3-Pin Connector) (16 AWG)* WA 4.5-inch Cable w/ 1/4 in Spade Terminals 6,3 mm x 0,8 mm (16 AWG)* YA 6-inch Cable w/Amp Super Seal 1.5 - 282104-1 (2-Pin Connector) (18 AWG)* ZA 10-inch Cable w/Deutsch DT06-2S-CE06 (2-Socket Connector) (18 AWG) AB Deutsch DT04-2P-E005 (2-Pin Connector)** BB 10-inch Cable w/Metripack 150 Delphi 12129615 (3-Pin Connector) (18 AWG)* DB 10-inch Cable w/AMP 2,5 mm System Series Connector 1-967402-1 (18 AWG)* EB 4.5-inch Cable w/Packard Shroud Connector 12015792 (2-Pin Connector) (18 AWG) FB 10-inch Cable w/Metripack 150 Delphi 12052641 (2-Pin Connector) (18 AWG) GB 10-inch Cable w/Deutsch Plug HD 16-3 96S (3-Pin Connector) (16 AWG)* *These connectors are designed for dual circuit (SPDT) by default. They can be used for single-circuit applications (SPNC/SPNO) by making suitable connections. Refer to wiring diagram. **Option AB is available only for LP and LE Series. 8 sensing.honeywell.com 25 individual Honeywell Pressure Switches ADDITIONAL INFORMATION The following associated literature is available on the Sensing and Control web site at sensing.honeywell.com: * Product installation instructions * Product range guide * Product application-specific information WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION * * The information presented in this product sheet is for reference only. Do not use this document as a product installation guide. Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell's standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer's sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell website, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. sensing.honeywell.com 9 Find out more Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office. To learn more about Honeywell's sensing and control products, call +1-815-235-6847 or 1-800-537-6945, visit sensing.honeywell.com, or e-mail inquiries to info.sc@honeywell.com Sensing and Control Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 honeywell.com 50094081-3-EN IL50 GLO May 2014 Copyright (c) 2014 Honeywell International Inc. All rights reserved. (R) DuPontTM, Teflon(R), Tefzel(R), and Kapton(R) are trademarks or registered trademarks of E.I. du Pont de Nemours and Company.