ETA USA
16170 Vineyard Blvd. Suite 180, Morgan Hill, CA 95037 Visit us at: www.eta-usa.com
Phone: 1-800-ETA-POWR, (408) 778-2793 Fax: (408) 779-2753 email at: sales@eta-usa.com
Conditions:
*1 Rated input and Rated output
*2 at Output current quick change 25% to 75%
*3 At 100% load (convection cooling)
Environmental Specification
Operating Temperature*3 -10 to +71 Ā°C
Operating Humidity 20~90% RH
Storage Temperature -30 to +85 Ā°C
Storage Humidity 10~95% RH [non-condensing]
Withstanding Voltage
Primary-Secondary AC3,000V for 1minute
Primary-Frame Ground AC2,500V for 1minute
Secondary-Frame Ground AC1,000V for 1minute
*Sensory Current: Secondary Frame Ground
(20[mA])/Others (10[mA])
Isolation Resistance Primary-Secondary-Frame Ground 100Mā¦(minimum) by
DC500V insulation tester
Vibration 5~10Hz:10mm double amplitude,10-55Hz:19.6m/s2,30 minute
cycle each along X,Y,Z axes(non-operating)
Shock 196 m/s2 on x,y,z axis
Cooling Convection
Leakage current 500ĀµA
MTBF >190,000 hours
Environmental Agencies
Line Conducted Noise [EMI] Built to meet FCC part 15 class B, VCCI-B, CISPR22-B, EN55022-B
Line Harmonic
Distortion/Current
IEC61000-3-2 Compliant
Safety UL60950-1 1st ed., CAN/CSA C22.2 No.60950-1-03 Approved
UL508 17th ed. , CAN/CSA C22.2 No.107.1-01 Approved
EN60950-1:2001+A11:2004 Approved
CE Markingļ¼EN60950-1:2001+A11:2004(LVD) Declared
Function/Protection
Over current Protection Operate at 105% min of rated current, automatic return
Over voltage Protection Input reentry at shutdown
Remote Sense Available
Remote Control Applicable by Option(External signal input is required)
Series Operation Available
Parallel Operation Not Available (N+1 Operation is Applicable by Diode-OR)
Driving Indicator Power Source on LED indication; Green
Mechanical
Dimension [mm] 33 W Ć 146.5 L Ć 81.5H
Weight [g](typical) 420