LESHAN RADIO COMPANY, LTD.
G16–1/2
MAXIMUM RATINGS(TJ=125°C unless otherwise noted)
MBD301 MMBD301LT1
Rating symbol value unit
Reverse Voltage V R30 Volts
Forward Power Dissipation P F
@TA=25 °C 280 200 mW
Derate above 25 °C 2.8 2.0 mW/ °C
Operating Junction T J °C
Temperature Range –55 to +125
Storage Temperature Range T stg –55 to +150 °C
DEVICE MARKING
MMBD301LT1=4T
ELECTRICAL CHARACTERISTICS(TA=25 °C unless otherwise noted)
Characteristic Symbol Min Typ Max Unit
Reverse Breakdown Voltage(IR=10µA) V (BR)R 30 Volts
Total Capacitance(VR=15V,f=1.0MHz,)Figure1 C T 0.9 1.5 pF
Reverse Leakage(VR=25V)Figure3 I R 13 200 nAdc
Forward Voltage(IF=1.0mAdc)Figure4 V F 0.38 0.45 Vdc
Forward Voltage(IF=10mAdc)Figure4 V F 0.52 0.6 Vdc
NOTE:MMBD301LT1 is also available in bulk packaging.Use MMBD301L as the device title to order this device in bulk.
Silicon Hot–Carrier Diodes
Schottky Barrier Diodes
3
CATHODE
1
ANODE
These devices are designed primarily for high–efficiency UHF and VHF detector
applications.They are readily adaptable to many other fast switching RF and digital
applications.They are supplied in an inexpensive plastic package for low–cost,
high–volume consumer and industrial/commercial requirements.They are also
available in a Surface Mount package.
EXtremely Low Minority Carrier Lifetime –15ps(Typ)
very Low Capacitance –1.5pF(Max)@VR=15V
CLow Reverse Leakage –IR=13 nAdc(Typ)MBD301,MMBD301
1
3
2
CASE 318–08, STYLE 6
SOT– 23 (TO–236AB)
MMBD301LT1
30 VOLTS
SILICON HOT–CARRIER
DETECTOR AND SWITCHING
DIODES
LESHAN RADIO COMPANY, LTD.
G16–2/2
MMBD301LT1
I F , FORWARD CURRENT (mA)
I R, REVERSE LEAKAGE ( µA)
2.8
2.4
2.0
1.6
1.2
0.8
0.4
00 3.0 6.0 9.0 12 15 18 21 24 27 30
500
400
300
200
100
00 102030 40506070 8090100
10
1.0
0.1
0.01
0.001
0 6.0 12 18 24 30
100
10
1.0
0.1 0.2 0.4 0.6 0.8 1.0 1.2
TYPICAL ELECTRICAL CHARACTERISTICS
V R , REVERSE VOLT AGE (VOLTS)
Figure 1. Total Capacitance I F , FORWARD CURRENT (mA)
Figure 2. Minority Carrier Lifetime
V R , REVERSE VOLT AGE (VOLTS)
Figure 3. Reverse Leakage V F , FORWARD VOLTAGE (VOLTS)
Figure 4. Forward Voltage
C T , T OTAL CAP ACITANCE (pF)
τ , MINORITY CARRIER LIFETIME (ps)
f =1.0MHz
T
A
= –40°C
T
A
= 85°C
T
A
= 25°C
KRAKAUER METHOD
T
A
= 100°C
75°C
25°C
SINUSOIDAL
GENERATOR
BALLAST
NETWORK
(PADS)
SAMPLING
OSCILLOSCOPE
(50 INPUT)
PADS
CAPACITIVE
CONDUCTION
FORWARD
CONDUCTION STORAGE
CONDUCTION
DUT
I
F(PEAK)
I
R(PEAK)
Figure 5. Krakauer Method of Measuring Lifetime