M. K. JUCHHEIM GmbH & Co JUMO Instrument Co. Ltd. JUMO PROCESS CONTROL INC. Delivery address:Mackenrodtstrae 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net JUMO House Temple Bank, Riverway Harlow, Essex CM 20 2TT, UK Phone: +44 1279 635533 Fax: +44 1279 635262 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk 885 Fox Chase, Suite 103 Coatesville PA 19320, USA Phone: 610-380-8002 1-800-554-JUMO Fax: 610-380-8009 E-mail: info@JumoUSA.com Internet: www.JumoUSA.com Data Sheet 90.2523 Indoor, outdoor and duct resistance thermometers for temperatures from -30 to +80C (200C) for use in HVAC IP20 to IP65 protection for 2-wire, 3-wire or 4-wire connections fitted transmitter option 4 - 20mA / 0 - 10V Indoor, outdoor and duct resistance thermometers for HVAC applications are mainly used for temperature measurement in rooms, air ducts and outdoors. Different instrument versions with plastic housings for different protection ratings are available to suit the particular measurement task. The measuring insert is normally fitted with a Pt100 temperature sensor to EN 60 751, Class B, in 2-wire circuit. Versions with Pt500, Pt1000 or Ni 1000 can also be supplied. An extension in 3- or 4-wire circuit, starting from the terminals, is possible. A transmitter can optionally be integrated. Technical data Terminal box Protection tube Measuring insert Transmitter 02.03/00311507 plastic PC housing (material PP on Type 902523/11), IP20 to IP65, Type 902523/25: IP54 and IP65 protection stainless steel 1.4571; 5.4mm and 6mm dia. Pt100 temperature sensor, EN 60 751, Class B, 2-wire circuit analog transmitter, output signal 4 - 20mA or 0 - 10V Page 1/6 M. K. JUCHHEIM GmbH & Co JUMO Instrument Co. Ltd. JUMO PROCESS CONTROL INC. Delivery address:Mackenrodtstrae 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net JUMO House Temple Bank, Riverway Harlow, Essex CM 20 2TT, UK Phone: +44 1279 635533 Fax: +44 1279 635262 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk 885 Fox Chase, Suite 103 Coatesville PA 19320, USA Phone: 610-380-8002 1-800-554-JUMO Fax: 610-380-8009 E-mail: info@JumoUSA.com Internet: www.JumoUSA.com Data Sheet 90.2523 Transmitter Output 4 - 20mA Input Measurement input Sensor current Sampling rate Measurement circuit monitoring Underrange Overrange Output 0 - 10V Pt100 (EN 60 751) 0.5mA continuous measurement because of analog signal path falling to 3.6mA rising to 22mA to < 28mA (24mA typical) 3.6mA 22mA to < 28mA (24mA typical) Probe short circuit Probe and lead break Output Output signal Transfer characteristic Transfer accuracy Damping of ripple on 24V supply voltage, amplitude 10V/50Hz, burden 470/load 10M Burden (Rb) Burden error 0V rising to 11V to < 14V (12V typical) 0V 11V to < 14V (12V typical) proportional DC current 4 - 20mA DC voltage 0 - 10V linear with temperature 0.1% 0.2% 37dB 40dB Rb = (Ub - 7.5V) / 22mA 0.02% / 1001 - - 10k / 0.1% Load/load error Settling time on temperature change Calibration conditions Calibration accuracy 10msec 24V DC / approx. 22C 0.2%1,2 or 0.2C 0.4C (typical) at 20C / 24V supply voltage Overall accuracy: sensor/calibration Supply Supply voltage (Ub) Reverse polarity protection Supply voltage error 7.5 - 30V DC 15 - 30V DC yes 0.01% per V deviation from 24V1 Ambient conditions Operating temperature range Storage temperature range Temperature error -40 to +85C -40 to +100C 0.01% per C deviation from 22C1 relative humidity 95% annual mean, no condensation Climatic conditions similar to EN 60 654, Class C1 EMC interference emission/immunity 1. All data refer to the end-of-range value 20mA. Page 2/6 EN 61 326, Class B / to industrial requirements 2. The larger value applies. Connection example with supply unit, 4 - 20mA output Connection example with supply unit, 0 - 10V output Controller + - + - + + Supply unit 7.5 - 30V DC + + + - Connection diagram Output 4 - 20mA Current output 4 - 20mA - 0 - 10V - N L1 Output 0 - 10V Connection for Supply voltage 7.5 - 30V DC - Supply unit 15 - 30V DC + 81 82 83 + 0 - 10V - 4 - 20mA - 02.03/00311507 Indicator Indicator 3-wire transmitter 2-wire transmitter Controller Terminal + 81 R = B - 82 Connection for Ub - 7.5V 81 82 22mA R B = burden resistance Ub = supply voltage + - Terminal Supply voltage 15 - 30V DC + 81 - 82 Voltage output 0 - 10V - 82 + 83 81 82 83 Load 10k + - + M. K. JUCHHEIM GmbH & Co JUMO Instrument Co. Ltd. JUMO PROCESS CONTROL INC. Delivery address:Mackenrodtstrae 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net JUMO House Temple Bank, Riverway Harlow, Essex CM 20 2TT, UK Phone: +44 1279 635533 Fax: +44 1279 635262 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk 885 Fox Chase, Suite 103 Coatesville PA 19320, USA Phone: 610-380-8002 1-800-554-JUMO Fax: 610-380-8009 E-mail: info@JumoUSA.com Internet: www.JumoUSA.com Data Sheet 90.2523 Dimensions Type 902523/10 Type 902523/11 Type 902523/12 approx. 52 Type 902523/13 02.03/00311507 Type 902523/20 Type 902523/25 Page 3/6 M. K. JUCHHEIM GmbH & Co JUMO Instrument Co. Ltd. JUMO PROCESS CONTROL INC. Delivery address:Mackenrodtstrae 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net JUMO House Temple Bank, Riverway Harlow, Essex CM 20 2TT, UK Phone: +44 1279 635533 Fax: +44 1279 635262 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk 885 Fox Chase, Suite 103 Coatesville PA 19320, USA Phone: 610-380-8002 1-800-554-JUMO Fax: 610-380-8009 E-mail: info@JumoUSA.com Internet: www.JumoUSA.com Data Sheet 90.2523 Order details: Indoor, outdoor and duct resistance thermometers (1) Basic version x x x x x x x x 902523/10 Indoor resistance thermometer, Protection IP20 902523/11 Indoor and outdoor resistance thermometer, Protection IP54 902523/12 Indoor and outdoor resistance thermometer, Protection IP65 902523/13 Indoor and outdoor resistance thermometer with stepped protection tube, Protection IP65 x x x x 568 572 803 807 x x x x x x x x x x x x x x x x x x 1001 1003 1005 1009 2001 2003 x x x x x x x x x x x x 1 2 3 x x x x x x x x x x x x 000 330 333 (2) Operating temperature in C -30 to +60C (range only in conjunction with extra code 330 or 333) -30 to +80C (standard) 0 to 40C (range only in conjunction with extra code 330 or 333) 0 to 60C (range only in conjunction with extra code 330 or 333) (3) Measuring insert 1 x Pt100 in 3-wire circuit 1 x Pt100 in 2-wire circuit 1 x Pt1000 in 2-wire circuit 1 x Ni 1000 in 2-wire circuit 2 x Pt100 in 3-wire circuit 2 x Pt100 in 2-wire circuit (4) Tolerance class to EN 60 751 Class B (standard) Class A (not for Type 902523/10 and transmitter) Class 1/3 DIN (not for Type 902523/10 and transmitter) (5) Extra codes no extra code analog transmitter, 4 - 20mA output (in conjunction with 1 x Pt100)* analog transmitter, 0 - 10V output (in conjunction with 1 x Pt100)* (1) Order example 902523/10 - * Please specify range in plain text. 1.List extra codes in sequence, separated by commas. 02.03/00311507 (2) - Order code (3) - 572 (4) - - 1001 - (5) / 1 / 0001 ,... Page 4/6 M. K. JUCHHEIM GmbH & Co JUMO Instrument Co. Ltd. JUMO PROCESS CONTROL INC. Delivery address:Mackenrodtstrae 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net JUMO House Temple Bank, Riverway Harlow, Essex CM 20 2TT, UK Phone: +44 1279 635533 Fax: +44 1279 635262 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk 885 Fox Chase, Suite 103 Coatesville PA 19320, USA Phone: 610-380-8002 1-800-554-JUMO Fax: 610-380-8009 E-mail: info@JumoUSA.com Internet: www.JumoUSA.com Data Sheet 90.2523 Order details: Indoor, outdoor and duct resistance thermometers (1) Basic version 902523/20 902523/25 Duct resistance thermometer with stepped protection tube, Protection IP65 Duct resistance thermometer with plain protection tube, Protection IP54 (2) Operating temperature in C -50 to +200C (standard) -30 to +60C (range only in conjunction with extra code 330 or 333) -30 to +80C (standard) 0 to 60C (range only in conjunction with extra code 330 or 333) x 380 568 572 807 x x x x x x x 1003 1005 1009 2003 x x x x x 1 2 3 (4) Tolerance class to EN 60 751 Class B (standard) Class A Class 1/3 DIN x x 6 (5) Protection tube diameter D in mm 6mm (Type 902523/20: stepped down from 6mm dia. to 3.3mm dia.) x x x x x 100 150 200 ... (6) Fitting length EL in mm (50 EL 500) 100mm 150mm 200mm please specify in plain text (in 50mm steps) x x x x x x x x 000 252 254 662 (7) Process connection no process connection screwed pipe joint G 1/4 (1/4" pipe) screwed pipe joint G 1/2 (1/2" pipe) stop flange 6mm dia. x x x x x x 000 310 330 333 404 (8) Extra codes no extra code protection tube stepped down from 6mm dia. to 3.3mm dia. analog transmitter, 4 - 20mA output (in conjunction with 1 x Pt100)* analog transmitter, 0 - 10V output (in conjunction with 1 x Pt100)* Protection IP65 x x x (3) Measuring insert 1 x Pt100 in 2-wire circuit 1 x Pt1000 in 2-wire circuit 1 x Ni 1000 in 2-wire circuit 2 x Pt100 in 2-wire circuit (1) Order example 902523/20 - * Please specify range in plain text. 1.List extra codes in sequence, separated by commas. 02.03/00311507 (2) - Order code (3) - 572 (4) - - 1003 - (5) - 1 - (6) - 6 - (7) - 100 - (8) / 252 / ,... 0001 Page 5/6 M. K. JUCHHEIM GmbH & Co JUMO Instrument Co. Ltd. JUMO PROCESS CONTROL INC. Delivery address:Mackenrodtstrae 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net JUMO House Temple Bank, Riverway Harlow, Essex CM 20 2TT, UK Phone: +44 1279 635533 Fax: +44 1279 635262 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk 885 Fox Chase, Suite 103 Coatesville PA 19320, USA Phone: 610-380-8002 1-800-554-JUMO Fax: 610-380-8009 E-mail: info@JumoUSA.com Internet: www.JumoUSA.com Data Sheet 90.2523 Page 6/6 Stock versions: (1) (2) (3) 902523/10 902523/10 902523/10 902523/10 902523/11 902523/11 902523/12 902523/12 902523/12 902523/13 902523/13 902523/13 - (1) 572 572 803 807 572 572 572 572 807 572 572 568 (2) 902523/20 902523/20 902523/20 02.03/00311507 - (4) - (3) 572 568 807 - 1001 2001 1003 1003 1003 2003 1003 2003 1003 1003 2003 1003 (4) 1003 1003 1003 - - (5) 1 1 1 - 1 1 1 1 1 1 1 1 1 1 1 1 / / / / / / / / / / / / (6) 6 6 6 - (5) Sales No. 000 000 330 (0 to 40C) 330 (0 to 60C) 000 000 000 000 330 (0 to 60C) 000 000 330 (-30 to +60C) 90/00065671 90/00065672 90/00064003 90/00065717 90/00055723 90/00055724 90/00064881 90/00064882 90/00064883 90/00064852 90/00064853 90/00065073 (8) Sales No. 000 330 (-30 to +60C) 330 (0 to 60C) 90/00064894 90/00065087 90/00064896 / (7) 100 100 100 - / 662 662 662 / / /