Series CCR-33S/CR-33S COAX SWITCHES Miniature DC-18 GHz/DC-22 GHz Failsafe SPDT Coaxial Switch PART NUMBER DESCRIPTION CCR-33S Commercial Failsafe SPDT, DC-18GHz CR-33S Elite Failsafe SPDT, DC-22GHz Available with USB & Ethernet Control! The CCR-33S/CR-33S is a broadband, SPDT, electromechanical, coaxial switch designed to switch a microwave signal from a common input to either of two outputs. The characteristic impedance is 50 Ohms. The small switches incorporate SMA connectors. The CCR-33S/CR-33S series switch is offered with a failsafe actuator. This design is compatible with the two most common mounting hole patterns. The CCR-33S/CR-33S series switch is interchangeable with a variety of switches. ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS ELECTRICAL CHARACTERISTICS Operating Temperature Commercial Model, CCR-33S Elite Model, CR-33S*** Form Factor -25C to 65C -55C to 85C SPDT, break before make Vibration (MIL-STD-202 Method 214, Condition D, non-operating) 10 g's RMS Frequency Range CCR-33S CR-33S DC-18 GHz DC-22 GHz Shock (MIL-STD-202 Method 213, Condition D, non-operating) 500 g's Characteristic Impedance 50 Ohms Standard Actuator Life Actuator Life w/ Additional Features 5,000,000 cycles 1,000,000 cycles Operate Time 10 ms (max.) Release Time 10 ms (max.) Connector Type SMA Actuation Voltage Available 12 15 24 28V Humidity (Moisture Seal) Available Actuation Current, max. @ ambient 200 250 120 90 mA Weight 1.65 oz. (46.78g) (max.) TYPICAL PERFORMANCE CHARACTERISTICS Frequency Insertion Loss, dB, max. Isolation, dB, min. VSWR , max. DC-3 GHz 3-6 GHz 6-12 GHz 12-18 GHz 18-20 GHz 20-22 GHz 0.2 0.2 0.4 0.5 0.6 0.6 70 70 60 60 50 50 1.25:1 1.25:1 1.4:1 1.5:1 1.6:1 1.6:1 For maximum limits, please see charts on page 3-5 PART NUMBERING SYSTEM CCR-33 S 1 C - T ** Series Options Connectors Actuator Type Actuator Voltage Connector S: SMA Female Actuator Voltage 1: 28 Vdc Failsafe 2: 15 Vdc Failsafe 3: 12 Vdc Failsafe 4: 24 Vdc Failsafe For other options, contact factory. (c) 2019 TELEDYNE RELAYS Actuator Type 0: Standard Contacts C: Indicator Contacts Options T: TTL Drivers with Diodes D: Transient Suppression Diodes N: Narrow Body **SEE PARTS LIST ON PAGE 8 M: Moisture Seal S: 9 Pin D-Sub Connector *** Indicator Contacts Operating Temperature -50C to 85C (Elite Model Only) (800) 284-7007 * www.teledynecoax.com CCR-33S/CR-33S Page 1 CCR-33S\CR-33S\022019\Q1 Series CCR-33S/CR-33S COAX SWITCHES Miniature DC-18 GHz/DC-22 GHz Failsafe SPDT Coaxial Switch SCHEMATICS AND MECHANICAL OUTLINE Analog TTL Indicators 2X SOLDER TERMINALS SOLDER WIRE MAXIMUM TEMP 250C FOR NO MORE THAN 5 SEC 2X SOLDER TERMINALS SOLDER WIRE MAXIMUM TEMP 250C FOR NO MORE THAN 5 SEC Indicators TTL Analog 2X SOLDER TERMINALS SOLDER WIRE MAXIMUM TEMP 250C FOR NO MORE THAN 5 SEC 2X SOLDER TERMINALS SOLDER WIRE MAXIMUM TEMP 250C FOR NO MORE THAN 5 SEC (1.80 MAX withTTL) (1.80 MAX withTTL) H = 1.30 MAX. STD MODEL H = 1.80 MAX. TTL MODEL H = 1.30 MAX. STD MODEL H = 1.80 MAX. TTL MODEL H = 1.30 MAX. STD MODEL H = 1.30 MAX. STD MODEL Standard Width Body Optional Narrow Width Body H = 1.80 MAX. TTL MODEL H = 1.80 MAX. TTL MODEL 1 Optional Narrow Width Body 6 Standard Width Body "-s option" 9-pin d-P/N sub 2706650 connector (example: 9 PIN D-SUB PINOUT FOR FAILSAFE SPDT Pin No. 1 2 3 4 5 6 7 8 9 OPTIONS Basic Indicators + - + - CCR-33S/CR-33S Page 2 A B C TTL TRUTH TABLE (with TTL option) Logic Input Indicators & TTL 1 1 Vsw Common P/N 2707572 1 Vsw A B1 C611 RF Path Indicator (if applicable) IN to 1 IN to 2 A 0 On Off C 0 1 Off On 0 C 9 Common 1 ccr-33s10-s) B 5 10 15 SPECIFICATIONS ARE AMPHENOL SUBJECT TO CHANGE WITHOUT NOTICE P/N P-17EHD-015P (c) 2019 TELEDYNE COAX SWITCHES CCR-33S\CR-33S\022019\Q1 Series CCR-33S/CR-33S COAX SWITCHES Miniature DC-18 GHz/DC-22 GHz Failsafe SPDT Coaxial Switch TYPICAL NARROWBAND RF INSERTION LOSS PERFORMANCE CURVES Insertion Loss ( 4-8 GHz ) 0.0 -0.1 -0.1 -0.2 -0.2 Insertion Loss (dB) Insertion Loss (dB) Insertion Loss ( DC-4 GHz ) 0.0 -0.3 -0.4 -0.5 -0.6 -0.7 -0.8 -0.9 -1.0 -0.3 -0.4 -0.5 -0.6 -0.7 -0.8 -0.9 0 0.5 1 1.5 2 2.5 3 3.5 -1.0 4 4 4.5 5 5.5 Frequency ( GHz ) -0.1 -0.1 -0.2 -0.2 -0.3 -0.4 -0.5 -0.6 -0.7 -0.8 -0.9 7.5 8 15 15.5 16 -0.4 -0.5 -0.6 -0.7 -0.8 -0.9 8 8.5 9 9.5 10 10.5 11 11.5 -1.0 12 12 12.5 13 13.5 14 14.5 Frequency ( GHz ) Insertion Loss ( 16-20 GHz ) Insertion Loss ( 20-22 GHz ) 0.0 0.0 -0.1 -0.1 -0.2 -0.2 Insertion Loss (dB) Insertion Loss (dB) 7 -0.3 Frequency ( GHz ) -0.3 -0.4 -0.5 -0.6 -0.7 -0.8 -0.9 -1.0 6.5 Insertion Loss ( 12-16 GHz ) 0.0 Insertion Loss (dB) Insertion Loss (dB) Insertion Loss ( 8-12 GHz ) 0.0 -1.0 6 Frequency ( GHz ) -0.3 -0.4 -0.5 -0.6 -0.7 -0.8 -0.9 16 16.5 17 17.5 18 18.5 19 19.5 20 -1.0 20 Frequency ( GHz ) 20.5 21 21.5 22 Frequency ( GHz ) elite model only TYPICAL MAXIMUM TEST LIMIT (c) 2019 TELEDYNE RELAYS (800) 284-7007 * www.teledynecoax.com CCR-33S/CR-33S Page 3 CCR-33S\CR-33S\022019\Q1 Series CCR-33S/CR-33S COAX SWITCHES Miniature DC-18 GHz/DC-22 GHz Failsafe SPDT Coaxial Switch TYPICAL NARROWBAND RF ISOLATION PERFORMANCE CURVES Isolation ( 4-8 GHz ) 0.0 -20.0 -20.0 -40.0 -40.0 Isolation (dB) Isolation (dB) Isolation ( DC-4 GHz ) 0.0 -60.0 -80.0 -100.0 -80.0 -100.0 -120.0 -140.0 -60.0 -120.0 0 0.5 1 1.5 2 2.5 3 3.5 4 -140.0 4 4.5 5 5.5 Frequency ( GHz ) -20.0 -20.0 -40.0 -40.0 -60.0 -80.0 -100.0 7.5 8 15 15.5 16 -60.0 -80.0 -120.0 8 8.5 9 9.5 10 10.5 11 11.5 12 -140.0 12 12.5 13 13.5 Frequency ( GHz ) 14 14.5 Frequency ( GHz ) Isolation ( 16-20 GHz ) Isolation ( 20-22 GHz ) 0.0 0.0 -20.0 -20.0 -40.0 -40.0 Isolation (dB) Isolation (dB) 7 -100.0 -120.0 -60.0 -80.0 -100.0 -60.0 -80.0 -100.0 -120.0 -140.0 6.5 Isolation ( 12-16 GHz ) 0.0 Isolation (dB) Isolation (dB) Isolation ( 8-12 GHz ) 0.0 -140.0 6 Frequency ( GHz ) -120.0 16 16.5 17 17.5 18 18.5 19 19.5 20 -140.0 20 20.5 Frequency ( GHz ) 21 21.5 22 Frequency ( GHz ) elite model only TYPICAL MAXIMUM TEST LIMIT CCR-33S/CR-33S Page 4 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE (c) 2019 TELEDYNE COAX SWITCHES CCR-33S\CR-33S\022019\Q1 Series CCR-33S/CR-33S COAX SWITCHES Miniature DC-18 GHz/DC-22 GHz Failsafe SPDT Coaxial Switch TYPICAL NARROWBAND RF VSWR PERFORMANCE CURVES VSWR ( DC-4 GHz ) VSWR ( 4-8 GHz ) 2.0 2.0 1.9 1.9 1.8 1.8 1.7 1.7 1.6 1.5 VSWR VSWR 1.6 1.4 1.3 1.4 1.3 1.2 1.2 1.1 1.0 1.5 1.1 0 0.5 1 1.5 2 2.5 3 3.5 1.0 4 Frequency ( GHz ) 4 4.5 5 1.9 1.9 1.8 1.8 1.7 1.7 1.6 1.6 1.5 1.4 1.3 1.2 1.1 1.1 9 9.5 10 10.5 11 11.5 1.0 12 12 12.5 13 13.5 Frequency ( GHz ) 1.9 1.9 1.8 1.8 1.7 1.7 1.6 1.6 1.5 1.4 1.3 1.2 1.1 1.1 17.5 18 14.5 15 15.5 16 1.4 1.2 17 14 1.5 1.3 16.5 8 VSWR ( 20-22 GHz ) 2.0 VSWR VSWR VSWR ( 16-20 GHz ) 16 7.5 Frequency ( GHz ) 2.0 1.0 7 1.4 1.2 8.5 6.5 1.5 1.3 8 6 VSWR ( 12-16 GHz ) 2.0 VSWR VSWR VSWR ( 8-12 GHz ) 2.0 1.0 5.5 Frequency ( GHz ) 18.5 19 19.5 20 1.0 20 Frequency ( GHz ) 20.5 21 21.5 22 Frequency ( GHz ) elite model only TYPICAL MAXIMUM TEST LIMIT (c) 2019 TELEDYNE RELAYS (800) 284-7007 * www.teledynecoax.com CCR-33S/CR-33S Page 5 CCR-33S\CR-33S\022019\Q1 Series CCR-33S/CR-33S COAX SWITCHES Miniature DC-18 GHz/DC-22 GHz Failsafe SPDT Coaxial Switch TYPICAL POWER PERFORMANCE CURVE Power Handling vs. Frequency 3000 2000 Power (W) 1000 800 600 400 STAN DAR DS 300 MA 200 SW ITC HES 100 80 60 40 30 20 10 .1 .2 .3 .4 .6 .8 1 2 4 6 8 10 18 Frequency GHz Estimates based on the following reference conditions: * Ambient temperature of 40C or less * Sea level operation * Load VSWR of 1.20:1 maximum * No high-power (hot) switching Please contact Teledyne Coax Switches for derating factors when applications do not meet the foregoing reference conditions. CCR-33S/CR-33S Page 6 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE (c) 2019 TELEDYNE COAX SWITCHES CCR-33S\CR-33S\022019\Q1 Series CCR-33S/CR-33S COAX SWITCHES Miniature DC-18 GHz/DC-22 GHz Failsafe SPDT Coaxial Switch GLOSSARY Actuator An actuator is the electromechanical mechanism that transfers the RF contacts from one position to another upon DC command. TTL Switch Driver Option As a special option, switch drivers can be provided for both failsafe and latching switches, which are compatible with industry-standard low-power Schottky TTL circuits. Arc Suppression Diode A diode is connected in parallel with the coil. This diode limits the "reverse EMF spike" generated when the coil deenergizes to 0.7 volts. The diode cathode is connected to the positive side of the coil and the anode is connected to the negative side. Performance Parameters vs Frequency Generally speaking, the RF performance of coaxial switches is frequency dependent. With increasing frequency, VSWR and insertion loss increase while isolation decreases. All data sheets specify these three parameters as "worst case" at the highest operating frequency. If the switch is to be used over a narrow frequency band, better performance can be achieved. Date Code All switches are marked with either a unique serial number or a date code. Date codes are in accordance with MILSTD-1285 Paragraph 5.2.5 and consist of four digits. The first two digits define the year and the last two digits define the week of the year (YYWW). Thus, 1032 identifies switches that passed through final inspection during the 32nd week of 2010. Failsafe A failsafe switch reverts to the default or failsafe position when actuating voltage is removed. This is realized by a return spring within the drive mechanism. This type of switch requires the continuous application of operating voltage to select and hold any position. (Multi-position switches are normally open with no voltage applied). Indicator Indicators tell the system which position the switch is in. Other names for indicators are telemetry contacts or tellback circuit. Indicators are usually a set of internally mounted DC contacts linked to the actuator. They can be wired to digital input lines, status lights, or interlocks. Unless otherwise specified, the maximum indicator contact rating is 30 Vdc, 50 mA, or 1.5 Watts into a resistive load. Isolation Isolation is the measure of the power level at the output connector of an unconnected RF channel as referenced to the power at the input connector. It is specified in dB below the input power level. SPDT Switch A single-pole double-throw, bi-directional switch that can be used as having one input and two outputs or two inputs and one output. Switching Time Switching time is the total interval beginning with the arrival of the leading edge of the command pulse at the switch DC input and ending with the completion of the switch transfer, including contact bounce. It consists of three parts: (1) inductive delay in the coil, (2) transfer time of the physical movement of the contacts, and (3) the bounce time of the RF contacts. (c) 2019 TELEDYNE RELAYS Actuator Current vs Temperature The resistance of the actuator coil varies as a function of temperature. There is an inverse relationship between the operating temperature of the switch and the actuator drive current. For switches operating at 28 VDC, the approximate actuator drive current at temperature, T, can be calculated using the equation: IT = IA [1 + .00385 (T-20)] Where: IT = Actuator current at temperature, T IA = Room temperature actuator current - see data sheet T = Temperature of interest in C Magnetic Sensitivity An electro-mechanical switch can be sensitive to ferrous materials and external magnetic fields. Neighboring ferrous materials should be permitted no closer than 0.5 inches and adjacent external magnetic fields should be limited to a flux density of less than 5 Gauss. SPECIAL FEATURE Switching High-Power or Highly Sensitive Signals Ensure the most linear response with the best galvanically matched contact system in the industry. Extremely low passive intermodulation is standard on all of our switches. Carrier Frequency 1 Carrier Frequency 2 PIM 3rd Order Frequency PIM 5th Order Frequency 870 MHz 893 MHz 847 MHz 824 MHz SPDT (800) 284-7007 * www.teledynecoax.com 3rd Order Intermodulation 5th Order Intermodulation -91 dBm -110 dBm -134 dBc -153 dBc CCR-33S/CR-33S Page 7 CCR-33S\CR-33S\022019\Q1 Series CCR-33S/CR-33S COAX SWITCHES Miniature DC-18 GHz/DC-22 GHz Failsafe SPDT Coaxial Switch FAILSAFE CCR-33S/CR-33S PART NUMBER LIST Part No. Part No. Part No. 1 CCR-33SXC 43 CCR-33SX0-TMS 85 CR-33SX0-NM 2 CCR-33SXC-D 44 CCR-33SX0-TN 86 CR-33SX0-NMS 3 CCR-33SXC-DM 45 CCR-33SX0-TNM 87 CR-33SX0-NS 4 CCR-33SXC-DMS 46 CCR-33SX0-TNMS 88 CR-33SX0-S 5 CCR-33SXC-DN 47 CCR-33SX0-TNS 89 CR-33SX0-T 6 CCR-33SXC-DNM 48 CCR-33SX0-TS 90 CR-33SX0-TM 7 CCR-33SXC-DNMS 49 CR-33SXC 91 CR-33SX0-TMS 8 CCR-33SXC-DNS 50 CR-33SXC-D 92 CR-33SX0-TN 9 CCR-33SXC-DS 51 CR-33SXC-DM 93 CR-33SX0-TNM 10 CCR-33SXC-M 52 CR-33SXC-DMS 94 CR-33SX0-TNMS 11 CCR-33SXC-MS 53 CR-33SXC-DN 95 CR-33SX0-TNS 12 CCR-33SXC-N 54 CR-33SXC-DNM 96 CR-33SX0-TS 13 CCR-33SXC-NM 55 CR-33SXC-DNMS 14 CCR-33SXC-NMS 56 CR-33SXC-DNS 15 CCR-33SXC-NS 57 CR-33SXC-DS 16 CCR-33SXC-S 58 CR-33SXC-M 17 CCR-33SXC-T 59 CR-33SXC-MS 18 CCR-33SXC-TM 60 CR-33SXC-N 19 CCR-33SXC-TMS 61 CR-33SXC-NM 20 CCR-33SXC-TN 62 CR-33SXC-NMS 21 CCR-33SXC-TNM 63 CR-33SXC-NS 22 CCR-33SXC-TNMS 64 CR-33SXC-S 23 CCR-33SXC-TNS 65 CR-33SXC-T 24 CCR-33SXC-TS 66 CR-33SXC-TM 25 CCR-33SX0 67 CR-33SXC-TMS 26 CCR-33SX0-D 68 CR-33SXC-TN 27 CCR-33SX0-DM 69 CR-33SXC-TNM 28 CCR-33SX0-DMS 70 CR-33SXC-TNMS 29 CCR-33SX0-DN 71 CR-33SXC-TNS 30 CCR-33SX0-DNM 72 CR-33SXC-TS 31 CCR-33SX0-DNMS 73 CR-33SX0 32 CCR-33SX0-DNS 74 CR-33SX0-D 33 CCR-33SX0-DS 75 CR-33SX0-DM 34 CCR-33SX0-M 76 CR-33SX0-DMS 35 CCR-33SX0-MS 77 CR-33SX0-DN 36 CCR-33SX0-N 78 CR-33SX0-DNM 37 CCR-33SX0-NM 79 CR-33SX0-DNMS 38 CCR-33SX0-NMS 80 CR-33SX0-DNS 39 CCR-33SX0-NS 81 CR-33SX0-DS 40 CCR-33SX0-S 82 CR-33SX0-M 41 CCR-33SX0-T 83 CR-33SX0-MS 42 CCR-33SX0-TM 84 CR-33SX0-N * X = 1 (28Vdc), 2 (15Vdc), 3 (12Vdc) and 4 (24Vdc) CCR-33S/CR-33S Page 8 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE (c) 2019 TELEDYNE COAX SWITCHES CCR-33S\CR-33S\022019\Q1