MP1505W THRU MP1510W 9261 Owensmouth Ave. Chatsworth, Ca 91311 Phone: (818) 701-4933 Fax: (818) 701-4939 Features * * * * 15 Amp Single Phase Bridge Rectifier 50 to 1000 Volts Mounting Hole For #8 Screw Plastic Case With Metal Bottom Any Mounting Position Surge Rating Of 300 Amps MP-50W Maximum Ratings * * Operating Temperature: -55C to +175C Storage Temperature: -55C to +175C Microsemi Catalog Number Device Marking MP1505W MP151W MP152W MP154W MP156W MP158W MP1510W MP1505W MP151W MP152W MP154W MP156W MP158W MP1510W Maximum Reccurrent Peak Reverse Voltage 50V 100V 200V 400V 600V 800V 1000V B Maximum RMS Voltage Maximum DC Blocking Voltage 35V 70V 140V 280V 420V 560V 700V 50V 100V 200V 400V 600V 800V 1000V C E D G AC + D A H Electrical Characteristics @ 25C Unless Otherwise Specified Average Forward Current Peak Forward Surge Current Maximum Forward Voltage Drop Per Element IF(AV) 15.0A TJ = 55C IFSM 300A 8.3ms, half sine AC - A VF 1.1V IFM = 7.5A per element; TJ = 25C* Maximum DC Reverse Current At IR 10A TJ = 25C Rated DC Blocking 0.5mA TJ = 100C Voltage *Pulse test: Pulse width 300 sec, Duty cycle 1% Santa Ana: (714) 979-8220 Scottsdale: (602) 941-6300 Sertech Labs: (617) 924-9280 Ireland: (353) 65-40044 Colorado: (303) 469-2161 Bombay: (91) 22-832-002 DIMENSIONS DIM A B C D E G H INCHES MIN ------.692 .040 .188 .429 Watertown: (617) 926-0404 Hong Kong: (852) 2692-1202 MAX 1.140 .452 .750 .732 ----.468 MM MIN ------17.6 1.00 4.77 10.9 MAX 29.00 11.50 19.10 18.6 ----11.9 NOTE 4PL/TYP Chatsworth: (818) 701-4933 MP1505W thru MP1510W Figure 1 Typical Forward Characteristics Figure 2 Typical Reverse Characteristics 100 10 60 6 40 4 20 2 1 10 .6 6 .4 4 .2 2 TJ=25C 25C Amps .1 1 Amps .06 .6 .04 .4 .02 .2 .01 .1 .006 .06 .00 4 .04 .002 .02 .01 .001 20 .2 .4 .6 .8 1.0 1.2 40 60 80 100 120 140 1.4 Volts Volts Instantaneous Forward Current - Amperesversus Instantaneous Forward Voltage - Volts Instantaneous Reverse Leakage Current - MicroAmperesversus Percent Of Rated Peak Reverse Voltage - Volts Figure 3 Forward Derating Curve Figure 4 Peak Forward Surge Current 30 300 25 250 20 200 150 15 Amps Amps 100 10 50 5 Single Phase, Half Wave 60Hz Resistive or Inductive Load 0 0 25 50 75 100 0 150 2 4 Average Forward Rectified Current - Amperesversus Ambient Temperature - C Colorado: (303) 469-2161 Bombay: (91) 22-832-002 6 8 10 20 40 00 60 80 100 Cycles 175 C Santa Ana: (714) 979-8220 Scottsdale: (602) 941-6300 Sertech Labs: (617) 924-9280 Ireland: (353) 65-40044 1 Peak Forward Surge Current - Amperesversus Number Of Cycles At 60Hz - Cycles Watertown: (617) 926-0404 Hong Kong: (852) 2692-1202 Chatsworth: (818) 701-4933