300 HIGH CURRENT & HIGH VOLTAGE POWER RELAYS
UL Recognized
File No. E13224
C US
50758
COMPLIES WITH REQUIREMENTS OF
IEC STANDARDS 947-4-1 AND
947-5-1 LOW VOLTAGE DIRECTIVE
IEC = INTERNATIONAL
ELECTROTECHNICAL COMMISSION
CE TESTING AND EVALUATION
PERFORMED BY THE UNDERWRITERS
LABORATORIES AS A THIRD PARTY
PARTICIPANT
*
*
*
OPTIONAL TOP FLANGE
MOUNT COVER
STANDARD SIDE
FLANGE COVER
FEATURES BENEFITS
MANUFACTURED
UNDER
ISO 9002
& QS 9000
2 MILLIMETER CONTACT GAPS
AND 8 MILLIMETER CREEPAGE
AND CLEARANCE
WIDE SPACING BETWEEN
STATIONARY CONTACT TERMINALS
ARC BARRIERS BETWEEN
CONTACTS
OPTIONAL BLOWOUT MAGNET
IMPROVED DIELECTRIC
STRENGTH BETWEEN CONTACT
WIDE SELECTION OF
MOUNTING OPTIONS
MEETS INTERNATIONAL REQUIREMENTS.
CLEARANCE FOR FULLY BOOTED
QUICK CONNECT TERMINALS
IMPROVED DIELECTRIC STRENGTH
BETWEEN CONTACT SETS.
HIGH VOLTAGE DC SWITCHING
4000 Vrms DIELECTRIC BETWEEN MUTUALLY
INSULATED CONDUCTIVE ELEMENTS AND FRAME.
ALLOWS INSTALLATIONS TO BE CUSTOMIZED
OPTIONAL
DIN MOUNT COVER
PHONE: (843) 393-5778 FAX: (843) 393-4123 EMAIL: info@magnecraft.com
4000
1000
1000
Not applicable
1000 @ 500
-30
+60
-30
+50
-40
+105
100,000
10,000,000
Any
Molded plastic
Polycarbonate
40
0.250, 0.09 x 0.032
(6.35, 2.29 x 0.81 )
85
DIELECTRIC S
DIELECTRIC STRENGTH
TRENGTH
Coil to Contacts:
Across Open Contacts:
Pole to Pole:
Contacts to Frame:
Insulation Resistance:
TEMPER
TEMPERA
ATURE
TURE
Operating, AC Lower:
Operating, AC Upper:
Operating, DC Lower:
Operating, DC Upper:
Storage, Lower:
Storage, Upper:
LIFE EXPECT
LIFE EXPECTANC
ANCY
Y
Electrical @ Rated Load (AC1):
Mechanical @ no Load :
MISCELLANEOUS
Operating Position:
Insulation Material:
Enclosure Material:
Cover Protection Category:
Terminals:
Weight:
UNITS
UNITS
V rms
V rms
V rms
V rms
megohms
minimum @VDC
ºC
ºC
ºC
ºC
ºC
ºC
operations
operations
94V-0
94V-0
IP
Inch (mm)
grams
COIL
COIL
Pull-in Voltage AC (50/60 Hz):<
Pull-in Voltage DC:<
Dropout Voltage AC (50/60 Hz):>
Dropout Voltage DC:>
Maximum Voltage:
Resistance:
Coil Power AC (60 Hz):
Coil Power DC:
Insulation System Per UL Standard 1446:
Duty:
CONT
CONTA
ACTS
CTS
Contact Material:
Contact Rating AC Amperes (AC1):
Contact Rating AC Voltage:
Contact Rating DC Amperes (DC1):
Contact Rating DC Voltage:
Horse Power (AC):
Horse Power (AC):
Minimum Recommended Load:
TIMING
Operate Time:
Release Time:
85
80
10
10
110
10
3
2
Class B (130 ºC)
or Class F (155 ºC)
Continuous
Silver alloy
gold flashed
30 / 20 / 15
277 / 600
30
28
1 @ 120
2 @ 208 - 600
100 @ 5 VDC
or 0.5 W
20
15
UNITS
UNITS
% of nominal
% of nominal
% of nominal
% of nominal
% of nominal
% ±
VA
W
A
V
A
V
HP
HP
ma
ms
ms
GENER
GENERAL SPECIFIC
AL SPECIFICA
ATIONS (@
TIONS (@ 25
25
ºC
ºC
)
)
1...38
9/04