1
Contents
What is Fluke? .........................2-3
New products
Fluke Connect®. . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Fluke 3500 Series. . . . . . . . . . . . . . . . . . . . . . . . . 5
Fluke 279 FC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Fluke 376 FC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Fluke 902 FC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Fluke 438-II .............................9
Fluke 1664, 1663, 1662 ................10 -11
Fluke Connect compatibility guide . . . . . . . . . . 12
Fluke Connect wireless tools ...............13
Fluke TiX500, Ti450 .....................14
Fluke TiS75. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Fluke 154 HART . . . . . . . . . . . . . . . . . . . . . . . . . 16
Fluke PRV240 ...........................17
Digital multimeters
Selection guide. . . . . . . . . . . . . . . . . . . . . . . 18-19
Fluke 3000 FC ..........................20
Fluke 179, 177, 175 ......................21
Fluke 289, 287 . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Fluke 87V ..............................23
Fluke 27-II, 28-II, 28-II EX ................24
Fluke 233 ..............................25
Fluk e 117, 116 , 115, 114, 113 ...............26
Fluke 88-V, 77-IV. . . . . . . . . . . . . . . . . . . . . . . . 27
Clamp Meters
Selection guide. . . . . . . . . . . . . . . . . . . . . . . 28-29
Fluke 373, 374 FC, 375 FC, 376 FC . . . . . . . . . .30
Fluke 325, 324, 323. . . . . . . . . . . . . . . . . . . . . . 30
Fluke 381, 365 ..........................31
Fluke 902, 368 FC, 369 FC ................32
Fluke a3000 FC, a3001 FC, a3002 FC, a3003 FC,
a3004 FC ..............................33
Fluke 353, 355 . . . . . . . . . . . . . . . . . . . . . . . . . .34
Wireless Tools
Fluke a3000 FC, a3001 FC, a3002 FC, a3003 FC,
a3004 FC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Fluke v3000 FC, v3001 FC ................35
Fluke t3000 FC . . . . . . . . . . . . . . . . . . . . . . . . . .35
Fluke ir3000 FC .........................35
PC300 FC ..............................35
Bench meters
Fluke 8846A, 8845A, 8808A ..............36
Laser distance meters
Fluke 424D, 419D, 414D ...................37
Earth ground testers
Selection guide. . . . . . . . . . . . . . . . . . . . . . . . . .38
Fluke 1625-2, 1623-2 ....................38
Fluke 1625-2 Kit, 1623-2 Kit. . . . . . . . . . . . . . .38
Fluke 1621, 1630 ........................39
Electrical testers
Fluke T5, T+Pro, T+ ......................40
Fluke T5-1000, T5-600 ...................40
Fluke 2AC, 1AC-II, 1LAC-II, LVD2 ...........40
Indoor air quality tools
Fluke 971, 985 ..........................41
Fluke 975V, 975 . . . . . . . . . . . . . . . . . . . . . . . . .42
Fluke 922, 922/Kit .......................42
Fluke RLD2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Fluke CO-205, CO-220. . . . . . . . . . . . . . . . . . . . 42
Fluorescent light tester
Fluke 1000FLT ..........................43
Insulation testers
Fluke 1587 FC, 1577 .....................44
Fluke 1507, 1503 . . . . . . . . . . . . . . . . . . . . . . . .45
Fluke 1555, 1550C, 1555 KIT, 1550C KIT. . . . .46
Power quality analyzers
Selection guide. . . . . . . . . . . . . . . . . . . . . . . . . . 47
Fluke 438-II, 437-II, 435-II, 434-II .........48
Fluke 1730 .............................48
Fluke 1736, 1738 ........................49
Fluke 345, 43B, VR1710. . . . . . . . . . . . . . . . . . .50
Norma 4000, 5000 .......................51
Fluke 1745, 1744, 1743 ...................51
Fluke 1750, 176 0 ........................52
Battery analyzers
Fluke BT521, BT520, BT510. . . . . . . . . . . . . . . .53
Process calibration tools
Selection guide. . . . . . . . . . . . . . . . . . . . . . . . . .54
Fluke 771, 772, 773 . . . . . . . . . . . . . . . . . . . . . .55
Fluke 789, 787 . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Fluke 715, 707, 705 . . . . . . . . . . . . . . . . . . . . . .57
Fluke 754, 753 . . . . . . . . . . . . . . . . . . . . . . . . . .58
Fluke 709, 709H. . . . . . . . . . . . . . . . . . . . . . . . . 58
Fluke 726, 725 . . . . . . . . . . . . . . . . . . . . . . . . . .59
Fluke 724, 712B, 714B . . . . . . . . . . . . . . . . . . . .60
Fluke 9142, 9143, 9144 ...................61
Fluke 9103, 9140 ........................61
Fluke 4180, 4181 ........................61
Fluke 9190A ............................61
Fluke 1523, 1524 . . . . . . . . . . . . . . . . . . . . . . . .62
Fluke 1586A . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Fluke 7526A . . . . . . . . . . . . . . . . . . . . . . . . . . . .62
Fluke 1551A Ex, 1552A Ex. . . . . . . . . . . . . . . . . 62
Fluke 719, 719PRO .......................63
Fluke 718 ..............................63
Fluke 717 ..............................63
Fluke 750P .............................63
Fluke 721 ..............................64
Fluke 700G, 700RG Series. . . . . . . . . . . . . . . . .64
Fluke 2700G series ......................65
Fluke P5500 . . . . . . . . . . . . . . . . . . . . . . . . . . . .65
Fluke 3130 .............................66
Fluke P3000 . . . . . . . . . . . . . . . . . . . . . . . . . . . .66
Intrinsically safe products
Fluke 28 II Ex ...........................67
Fluke 707 Ex. . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Fluke 718 Ex . . . . . . . . . . . . . . . . . . . . . . . . . . . .67
Fluke 721 Ex . . . . . . . . . . . . . . . . . . . . . . . . . . . .67
Fluke 725 Ex. . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Fluke 700P Ex ...........................67
Fluke 568 Ex. . . . . . . . . . . . . . . . . . . . . . . . . . . .67
700G Series Pressure Gauges ..............67
1551A EX, 1552A Ex “Stik” Thermometers. . . . 67
ScopeMeter® test tools
Selection guide. . . . . . . . . . . . . . . . . . . . . . . . . .68
Fluke 125/B, 124/B, 123/B ................69
Fluke 190-502 . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Fluke 190-104 ..........................70
Fluke 190-202 ..........................70
Fluke 190-102 ..........................70
Fluke 190-062 . . . . . . . . . . . . . . . . . . . . . . . . . .70
Fluke 190-504 . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Infrared tools
Selection guide. . . . . . . . . . . . . . . . . . . . . . . 72-73
Fluke Expert Series
Fluke TiX1000/660/640 ..................74
Fluke TiX560/520/500 ...................74
Fluke Professional Series
Fluke Ti450/400/300 ....................75
Fluke Smartview Software ................75
Fluke Performance Series
Fluke TiS75/65/60/55/50/45/40. . . . . . . . . . . . 76
Fluke TiS45/40, TiS20, TiS10 ..............76
Fluke Visual IR-Thermometers
and IR-Windows
Fluke VT04/VT04A ......................77
Fluke CV400/401/300/301/200 ............77
Fluke CLKT100/75/50 ....................77
Fluke 62 Max+, 62 Max, 59 Max, 572-2. . . . . . 78
Fluke 54-2-B, 53-2-B, 52-2, 51-2 ...........78
Fluke 568, 566, 561, 61, 63. . . . . . . . . . . . . . . . 79
Alignment tools
Fluke 830 ..............................80
Stroboscopes
Fluke 820-2 ............................81
Vibration
Fluke 810 ..............................82
Fluke 805 FC. . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Accessories
Cases and holsters ....................84-86
Sets and kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
Test leads, probes and clips ...............88
Fluke SureGrip™ accessories ...............89
Fluke temperature accessories ..........90-91
Fluke current clamps . . . . . . . . . . . . . . . . . .92-93
Fluke lights and hangers . . . . . . . . . . . . . . . . . .94
Specialty accessories. . . . . . . . . . . . . . . . . . . . . 95
CONTENTS
2
What is Fluke?
Fluke Corporation is the world leader in the manufacture, distribution and service of electronic
test tools and software. Sales and service subsidiaries are located in Europe, North America,
South America, Asia and Australia. Fluke Corporation has authorized distributor and manufac-
turer representative channels in more than 100 countries and employs approximately 2,400
people.
From industrial electronic installation, maintenance and service, to precision measurement
and quality control, Fluke tools help keep business and industry around the globe up and
running.
Why choose Fluke?
With more than 60 years of innovation, Fluke tools are designed with you in mind.
Fluke tools are known for portability, ruggedness, safety ease of use, accuracy and rigid
standards of quality.
Our after-service team offers a range of capabilities beyond repairing and calibrating your
instrument.
We help you keep up on the latest technologies and safety standards with hands-on seminars,
online trainings and quick reads.
Over 40 of our tools now use the Fluke Connect® app and online dashboard to help you save
and share data, act on events, and increase workplace safety.
Our core values:
Customers talk, we listen
Results matter
Innovation: defines our future
Continuous improvement is our way of life
The best team wins
Our customer has the right to get a little bit more than they paid for
Going green – minimizing our environmental impact
To reduce our carbon footprint, Fluke is eliminating paper manuals, inserts and software CDs
in product shipments. We are “Going Green” on more products every day.
Join us in helping the environment by choosing paperless options. If you want a hard copy, we
will help you download one online or deliver one at no cost–anywhere in the world.
Learn more at: www.fluke.com/productinfo
We must always recognize the customer is our boss.
We exist to serve their needs and they have the right
to a little more than they thought they paid for.
John M. Fluke, Sr.
Aerial photo of Fluke Park,
Everett, WA
John M. Fluke, Sr.
www.fluke.com
3
Social media
We want to hear what you think of our products and services.
“Wouldn't be without mine.”
T. Green
“Boy, what will they think of next?
C. Harris and D. Williams
“The job keeps me up and running.
Fluke keeps me safe. D. Julio
www.facebook.com/fluke.corporation
www.twitter.com/flukecorp
www.youtube.com/flukecorporation
“Love all products that are Fluke,
I’m a 3rd generation user and
thank you: for such great quality
and dependable products, we will
ALWAYS use Fluke.” C. Jones
“I don’t have to second guess with
Fluke meters, I trust my life with
them! C. Jackson
Below are our social media channels, we invite you to join the conversation!
Fluke social media posts
2015
Winner
Fluke Connect® Assets
Fluke Connect® Assets
TiX560 Infrared Camera
902 FC True-rms Wireless
HVAC Clamp Meter
Winning tools
www.fluke.com
4
Fluke Connect
An integrated system of wireless test tools and asset management software.
Sign up for your free trial at: flukeconnect.com/freetrial
WiFi or cellular service is required to share data. Smart phone, wireless service and data plan not included with purchase. First 5 GB of
storage is free. Phone support details can be viewed at fluke.com/phones.
Free Trial Terms: Open to those 18 years or older (or the age of majority under applicable law, whichever is older). Free trial is for a limited
duration and is offered for a limited time. Void where prohibited by law. Terms and conditions are available upon registration.
Screens adjusted slightly to accommodate print. Smartphone is not included with purchase.
Within your provider’s wireless service area and subject to your plan’s pricing and other terms. Fluke Connect is not available in all
countries. Some Fluke Connect features require a subscription subject to payment terms and may not be available in all countries.
Preventive maintenance simplified. Rework eliminated.
Save time and improve the reliability of your maintenance data by wirelessly syncing
measurements using the Fluke Connect® system.
Eliminate data-entry errors by saving measurement data directly from the tool and associat-
ing it with the work order, report or asset record
Maximize uptime and make confident maintenance decisions with data you can trust and
trace
Access baseline, historical and current measurements by asset
Move away from clipboards, notebooks and multiple spreadsheets with a wireless one-step
measurement transfer
Share your measurement data using ShareLive video calls and emails
Fluke Connect enabled products include:
Current meters
Digital multimeters
Installation testers
Portable oscilloscopes
Temperature meters
Voltage meters
Vibration meters
Process tools
Infrared cameras
Instantly trend and monitor
intermittent problems with
TrendIt graphs.
Wirelessly save
measurements directly from
your test tools into work
ordersonly available with
Fluke Connect®
www.fluke.com/flukeconnecttools
4
NEW PRODUCTS
New Products
5
NEW PRODUCTS
www.fluke.com/flukeconnecttools New Products
Fluke 3501 FC Gateway
Fluke 3520 FC AC Current
iFlex Sensor
Fluke 3500 Series Condition Monitoring System
Fluke is revolutionizing industrial condition monitoring with the first portable,
easy-to-install system that you can access from anywhere, anytime.
The Fluke Condition Monitoring System integrates sensor measurements, analytics, cloud
storage, alarms and communication tools all in one system. And, it installs in a matter of
minutes.
Get an overall picture of the health of your equipment with a history of measurements before,
during and after an event. The Fluke Connect® condition monitoring software will send you
an alarm anytime your equipment is working outside of normal perimeters. The system scales
to your plant, whether your equipment is aging but heavily relied on or new complex and more
challenging to maintain. With easy to use Fluke technology, set up and start monitoring in less
than an hour - even in tight, difficult to reach spots.
Product highlights
Provides continuous monitoring for your equipment
Helps get to the root cause faster
Monitors equipment from anywhere
Delivers real-time alarms
Features fast and cost-effective set up and maintenance
Ordering information
Models Included
FLK-3501 FC Gateway Gateway, antenna, power supply, mounting bracket, rail mounting clip, Tpak magnetic
hanger, hang strap
FLK-3510 FC AC Voltage
Sensor
Sensor, test leads, AC285 alligator clips, magnetic hanging strap
FLK-3511 FC DC Voltage
Sensor
Sensor, TL220 test leads, AC220 alligator clips, magnetic hanging strap
FLK-3520 FC AC Current
iFlex Sensor
Sensor, iFlex® current probe, magnetic hanging strap
FLK-3521 FC DC 2000A
Current Sensor
Sensor, 2000 A dc current clamp, magnetic hanging strap
FLK-3530 FC K-Type
Temperature Sensor
Sensor, k-type thermocouple thermometer, magnetic hanging strap
FLK-3540 FC 3-Phase Power
Monitor
Power monitor, 3 iFlex current clamps, voltage test lead 3-Phase+N, 2 test lead sets,
cable marker set
FLK-CXT 3500 Rugged Hard
Case with Foam insert
6
NEW PRODUCTS
www.fluke.com/279fc
Fluke 279 FC True-rms Thermal Multimeter
Find. Repair. Validate. Report.
The 279 FC is a full-featured digital multimeter with integrated thermal imaging and is
designed to increase your productivity and confidence. The thermal multimeter helps you find,
repair, validate and report many electrical issues quickly so that you are confident problems
are solved.
Locate the problem immediately
Thermal imaging multimeters are a first-line troubleshooting tool for electrical equipment that
can check hot spots on high-voltage equipment and transformers, detect heating of fuses,
wires, insulators, connectors, splices and switches. Scanning with the 279 FC’s thermal
imager reveals many electrical issues rapidly and from a safe distance. By combining two
tools into one, the thermal multimeter lightens the load and increases productivity.
Expanded functionality
Compatible with iFlex® (a flexible current clamp) to expand your measurement capabilities
and get into tight, hard to reach spaces for current measurement (up to 2500 A ac). The large
full-color LCD screen makes for easier and clearer viewing of images and readings. The 10
hour+ rechargeable battery keeps you going all day long under normal conditions.
Communicate your results
With built-in Fluke Connect®, transmit wirelessly to a smartphone and save time on reporting
to validate work is complete. Troubleshoot better by instantly trending and monitoring
measurements live on your smartphone screen. Create and email reports right from the field.
Ordering information
Models Included accessories
FLK-279 FC TRMS Thermal
Multimeter
TL75 test leads, rechargeable lithium ion battery and charger
FLK-279 FC/iFlex TRMS
Thermal Multimeter
18-inch (45.72 cm) iFlex flexible current probe, TL175 test leads, rechargeable lithium
ion battery, charger, hanging strap and soft carrying case
Specifications
DMM
Voltage ac/dc 1000 V
Current ac 2500 A ac (with iFlex Flexible Current probe)
Resistance 50 M Ω
Frequency 100 kHz
Capacitance 9,999 µF
Continutity/Diode test/
Min Max/Display hold
Infrared camera
Resolution 80 x 60
Temperature range -10 °C to 200 °C (14 °F to 392 °F)
Other
Safety rating CAT III 1000 V, CAT IV 600 V
Warranty Three year
New Products
With built-in Fluke Connect,
transmit results wirelessly
to a smartphone and save
time on reporting to validate
work is complete.
Quickly find, repair,
validate and report
many electrical
issues.
Fluke 279 FC
Thermal Multimeter
7
NEW PRODUCTS
www.fluke.com/376 New Products
Fluke 376 FC True-rms Wireless AC/DC
Clamp Meter
Expand your measurement range with increased flexibility
The Fluke 376 FC offers advanced troubleshooting performance. The iFlex® flexible current
probe allows for easy measurement around wires in tight spaces. In addition, the Fluke 376 FC
is now part of the Fluke Connect® family of wireless test tools. Now you can:
Troubleshoot faster: Instantly log, trend, and monitor intermittent problems with a 65,000
measurement internal memory and Trendit graphs
Work safer: Connect your meter to your phone through Bluetooth, clamp your meter around a
conductor and walk up to 30 m (98 ft) away from the point of measurement
Save time reporting: Easily create reports by capturing measurements from your meter and
email them right from the field
Innovative flexible current probe: Measure around cumbersome conductors and improve
wire access in tight spaces
Share from anywhere: Stay on the same page when you and your team are in different
places with ShareliveTM videocall
Ordering information
Models Included accessories
FLUKE-376 FC, Wireless
True-rms AC/DC Clamp
meter with iFlex
18-inch (45.72 cm) iFlex flexible current probe, test leads, TPAK magnetic hanging strap,
soft carrying case, instruction card, safety information sheet, two AA alkaline batteries
Specifications
Functions Range and resolution
Safety rating CAT III 1000 V, CAT IV 600 V
A ac range 999.9 A with clamp jaws, 2500 A with iFlex® flexible current clamp
A dc range 999.9 A
Best resolution 0.1 A
V ac range 1000 V
V dc range 1000 V
mV dc range 500 mV
Ohms range 60.00 kΩ
Frequency 5 - 500.0 Hz
Capacitance 1 μF - 1,000 μF
Auto shutoff
True rms
Display hold
Inrush measurements
Backlight
DC Zero
Min/Max
Fluke Connect® compatible
VFD low-pass filter
Logging
iFlex® flexible current clamp Included
8
NEW PRODUCTS
www.fluke.com/902
New Products
Fluke 902 FC True-rms HVAC Clamp Meter
Improve productivity in the field
The Fluke 902 FC delivers the features necessary to diagnose and repair HVAC systems.
Additionally, with Fluke Connect® you can trend measurements, create and send reports right
from the field, safely stay away from live equipment.
Applications for HVAC
600 A ac current measurement
600 V ac and dc voltage measurement
Temperature measurement from -10 °C to 400 °C (14 °F to 752 °F)
1000 μF capacitance measurement
DC current measurement to 200 μA
True-rms voltage and current for accurate measurements on non-linear signals
Resistance measurement to 60 kΩ
Min and max recording to capture variations automatically
Applications for HVAC
Get more done faster and safer with Fluke Connect by capturing measurements wirelessly.
Save your measurement to Fluke Cloud™ storage for further analysis
Read measurements on your phone at a safe distance
Instantly trend and monitor measurements live on your phone screen
Ergonomic design fits in your hand and can be used while wearing PPE gear
Three-year warranty
Ordering information
Models Included accessories
FLK-902 FC HVAC Clamp
Meter
TL75 test leads, 80BK integrated DMM temperature probe, 2 AA alkaline batteries, soft
carrying case, users’ manual, Statement of Calibration
Specifications
General specifications
A ac (via Jaw) Range 60.00/600.0 A
Resolution 0.01/ 0.1A
Accuracy 2.0 % ± 5 digit (45-65 Hz)
2.5 % ± 5 digit (65-400 Hz)
Crest Factor (50 Hz or 60 Hz) 2.5 MIN @ 220 A
3.0 MIN @ 180 A
> 1.4 MIN @ 600 A
Add 2 % for CF > 400A
V ac Resolution 0.1 V
Accuracy (45-400 Hz) 1.5% ± 5 digits
Range 600.0 V
V dc Resolution 0.1 V
Accuracy 1 % ± 5 digits
Range 600.0 V
Ohms
Resolution 0.1/1/10
Accuracy 1 % ± 5 digits
Range 600/6000/60.00kΩ
Capacitance
Resolution 0.1/1 µF
Accuracy 1 % ± 4 digits
Range 100.0/1000 µF
µA
Resolution 0.1 µA
Accuracy 1% ± 5 digits
Range 200 µA
Contact temperature Resolution 0.1 C/F
Accuracy 1 % ± 8 digits
Range -10 °C to 400 °C (14 °F to 752 °F)
Continuity beeper Beeper volume 75 dBA nom. 15 cm. from case front
On thresh <= 30 Ω
9
NEW PRODUCTS
www.fluke.com/438 New Products
Fluke 438-II Power Quality and Motor Analyzer
Quickly and easily discover electrical and mechanical performance of electric
motors, and evaluate power quality with a single test tool
The new Fluke 438-II Power Quality and Motor Analyzer adds key mechanical measurement
capabilities for electric motors to the advanced power quality analysis functions of the Fluke
430 Series II Power Quality Analyzers. Quickly and easily measure and analyze key electrical
and mechanical performance parameters such as power, harmonics, unbalance, motor speed,
torque and mechanical power without the need of mechanical sensors.
Measure key parameters on direct-on-line motors including torque, RPM, mechanical power
and motor efficiency
Perform dynamic motor analysis by plotting of motor de-rating factor against load according
to NEMA guidelines
Calculate mechanical power and efficiency without the need of mechanical sensors, just
connect to the input conductors and you’re ready to go
Measure electrical power parameters such as voltage, current, power, apparent power,
power factor, harmonic distortion and unbalance to identify characteristics that impact
motor efficiency
Identify power quality issues such as dips, swells, transients, harmonics and unbalance
PowerWave data technology captures fast RMS data, and shows half-cycle averages and
waveforms to characterize electrical system dynamics (generator start-ups, UPS switching
etc)
Waveform capture function captures 100/120 cycles (50/60 Hz) of each event detected
event, in all modes, without set-up
Automatic transient mode captures waveform data at 200 kS/s on all phases simultaneously
up to 6 kV
Fluke Connect® Compatible* View data locally on the instrument, via Fluke Connect mobile
app and PowerLog 430-II desktop software
* Not all models are available in all countries. Check with your local Fluke representative.
Ordering information
Models Included accessories
FLUKE-438-II Three-Phase
Power Quality and Motor
Analyzer
Test lead set, i430 thin flexible current probes (4), battery, power adapter, combination
WiFi/SD card*, Soft carry case, CD Rom with PowerLog 430-II software and user
documentation
FLUKE-430-II/MA Upgrade option for 434-II, 435-II, and 437-II Power Quality Analyzers with firmware
license code
Specifications
Motor measurement Range Resolution Resolution Default limit
Mechanical motor power 0.7 kW to 746 kW
1 hp to 1000 hp
0.1 kW
0.1 hp
± 3 %1
± 3 %1
100 % = rated power
100 % = rated power
Torque 0 Nm to 10 000 Nm
0 lb ft to 10 000 lb ft
0.1 Nm
0.1 lb ft
± 5 %1
± 5 %1
100 % = rated torque
100 % = rated torque
rpm 0 rpm to 3600 rpm 1 rpm ± 3 %1100 % = rated rpm
Efficiency 0 % to 100 % 0.10 % ± 3 %1NA
Unbalance (NEMA) 0 % to 100 % 0.10 % ± 0.15 % 5%
Harmonics voltage factor
(NEMA)
0 to 0.20 0.1 ± 1.5 % 0.15
Unbalance derating factor 0.7 to 1.0 0.1 indicative NA
Harmonics derating
factor
0.7 to 1.0 0.1 indicative NA
Total NEMA derating
factor
0.5 to 1.0 0.1 indicative NA
10
NEW PRODUCTS
Fluke 1660 Series Multifunction Installation
Testers
Installation Testers: A Multifunction Tester that Offers Great Versatility
The new Fluke 1660 Series Installation Testers are the only installation testers that help
prevent damage to connected appliances and also allow users to send test results wirelessly
via smartphone directly from the field.
Fluke Connect© compatible (1664 FC only)
View test results on your smartphone via Fluke Connect® mobile app and Data Management
Software (Fluke DMS, sold separately). Download the free Fluke Connect app to enable
wireless data transmission and Fluke Cloud™ storage.
Insulation pretest (1664 FC only)
The new Fluke 1660 Series Installation Testers are the only installation testers that help
prevent damage to connected appliances.
Auto test sequence (1664 FC only)
Start a sequence of seven critical tests with one press of the TEST button.
Product highlights
Heavy duty, single input line cord, guards against failures in the field
Z Max memory function for loop/line test
Three-year standard warranty
Safety rating (IEC/EN 61010): CAT III 500 V, CAT IV 300 V
Key product capabilities
The 1660 Series testers verify the safety of electrical installations in domestic, commercial
and industrial applications. They can ensure that fixed wiring is safe and correctly installed
to meet the requirements of IEC 60364-6 and all relevant local standards.
Fluke 1664 FC
The Fluke 1664 FC is the only installation tester that protects connected appliances from
damage during insulation tests, and allows you to share your test results wirelessly by
smartphone with coworkers or customers. Fluke’s patent pending Insulation PreTest stops you
from performing tests with appliances that are connected to the system during test. This helps
eliminate accidental damage and keeps your customers happy.
In addition, the Fluke 1664 FC offers you the power of Fluke Connect. Now you can send test
results straight from your Fluke 1664 FC to your smartphone, and transmit those results to
other members of your team. You can get feedback, suggestions and even have work orders
sent to your job site. You can also save your test results to Fluke Cloud™ storage. No more
writing down data on paper with the possibility of transcription errors. Cloud storage gives
you a fast, secure and accurate way to storing all your test data and create test certificates
with Fluke DMS.
Fluke 1663
The ideal tester for professional trouble-shooters. This instrument is ideal for professional
users–high-end functionality, advanced measurement capability, yet it is still easy to use.
Operation is intuitive and easily mastered by all levels of field workers.
Fluke 1662
A solid, basic installation tester. The Fluke 1662 gives you Fluke reliability, simple operation
and all the testing power you need for basic installation testing.
www.fluke.com/1664fc
11
NEW PRODUCTS
Ordering information
Models Included accessories
FLK-1664 FC Multifunction
Installation Tester 6x AA (IEC LR6) cell batteries, C1600 hard carrying case, zero adapter, heavy duty
mains cord, STD standard test lead set, padded carrying and waist strap, quick
reference guide, TP165X remote control probe and lead set (FTP/UK fused probes,
UK only), user’s manual on CD
FLK-1663 Multifunction
Installation Tester
FLK-1662 Multifunction
Installation Tester
www.fluke.com/1664fc
Specifications
General specifications
Size 10 cm (L) x 25 cm (W) x 12.5 cm (H)
Weight (incl. batteries) approx. 1.3 kg
Battery size, quantity 1.5 V type AA (IEC LR6), 6 pcs.
Sealing IP 40
Safety Complies with IEC/EN61010-1, UL61010, ANSI/ISA –s82.02.01 and CAN/CSA c22.2
No. 1010)
Safety rating (IEC/EN61010) CAT III 500 V, CAT IV 300 V
Performance EC/EN61557-1 to IEC/EN61557-7 and IEC/EN61557-10
Selection guide
1664 FC 1663 1662
Insulation-PreTest™ safety function
Insulation at L-N, L-PE, N-PE inputs
Auto Test sequence
Loop and line resistance—mΩ resolution
Continuity at L-N, L-PE, N-PE inputs
Test smooth dc sensitive RCDs (Type B/B+)
Earth resistance
Voltage trms (ac and dc) and frequency •••
Wiring polarity checker, detects broken PE and N wires •••
Insulation resistance •••
Continuity and resistance •••
Measure motor windings with continuity test (@ 10 mA) •••
Loop and line resistance •••
Prospective Earth Fault Current (PEFC/IK) •••
Prospective Short-Circuit Current (PSC/IK) •••
RCD trip time •••
RCD trip current (ramp test) •••
Measures trip time and current for RCD type A and AC in one test •••
RCD variable test current •••
Automatic RCD test sequence •••
Phase sequence test •••
Z Max Memory
Memory •••
IR-USB and BLE interface (when used with optional Fluke DMS and FVF
software)
IR-USB/
BLE
IR-USB IR-USB
12
NEW PRODUCTS
www.fluke.com/flukeconnecttools
12 Fluke Connect
Fluke Connect® compatibility guide
The Fluke Connect app displays readings from up to 10 modules on the iPhone and six modules on an Andriod phone.
The TiX560, TiX520, TiX500, Ti450, Ti400, Ti300, TiS75, TiS65, TiS60, TiS55, TiS50, TiS45, TiS40, TiS20 and TiS10
Infrared Cameras display their own measurements plus readings from up to five wireless modules. The 3000 FC wireless
digital multimeter displays its own readings plus measurements from up to three wireless modules.
Fluke Connect™ tools
Fluke Connect App – iOS and Android™
TiX560/520/500 Thermal Imagers
Ti450/400/300 Thermal Imagers
TiSxx Series Thermal Imagers
3000 FC Digital Multimeter
a3000 FC AC Current Clamp Meter
902 FC True-rms HVAC Clamp Meter
376/375/374 FC True-rms Clamp Meters
a3001 FC iFlex® AC Current Meter
a3002 FC AC/DC Current Meter Module
a3003 FC 2000 A DC Current Clamp Meter
a3004 FC DC 4-20 mA Current Clamp Meter
v3000 FC AC Voltage Meter
v3001 FC DC Voltage Meter
t3000 FC Temperature Meter
438-II/437-II/435-II/434-II PQ Analyzers
789 ProcessMeter™
1587 Insulation Multimeter
1664 FC Installation Tester
805 FC Vibration Tester
125B/124B/123B ScopeMeter
279 FC Thermal Multimeter
3500 Series Condition Monitoring System
ir3000 FC Wireless Connector
Fluke Connect App – iOS and
Android•••••••••••••••••••••••
TiX560/520/500
Thermal Imagers
Ti450/400/300/200
Thermal Imagers
TiS75/65/60/55/50/45/40/20/10
Thermal Imagers
3000 FC Digital Multimeter
a3000 FC AC Current
Clamp Meter
902 FC True-rms HVAC Clamp
Meter
376/375/374 FC True-rms Clamp
Meters
a3001 FC iFlex® AC
Current Meter
a3002 FC AC/DC Current Meter
Module
a3003 FC 2000 A DC Current
Clamp Meter
a3004 FC 4-20 mA DC Current
Meter
v3000 FC AC Voltage Meter
v3001 FC DC Voltage Meter
t3000 FC Temperature Meter
438-II/437-II/435-II/434-II
Power Quality Analyzers
789 ProcessMeter™
1587 Insulation Multimeter
1664 FC Installation Tester
805 FC Vibration Tester
125B/124B/123B ScopeMeters®
279 FC Thermal Multimeter
3500 Series Condition
Monitoring System
ir3000 FC Wireless Connector Connect adapter to: Fluke 789, 289, 287
13
NEW PRODUCTS
www.fluke.com/flukeconnecttools
Kits—buy more, save more
General Maintenance
System HVAC System Wireless AC Voltage Kit Ti400/a3001 FC iFlex
Wireless Fluke Connect® tools
Ordering information
Kits Included
FLK-3000FC Industrial System Wireless multimeter, 3 wireless iFlex current meters, 3 wireless ac voltage meters, 4
hanging straps with magnets, 2 test leads with clips, USB, CD, info pack, and soft case
FLK-3000FC GM, General
Maintenance System
Wireless multimeter, wireless iFlex ac current meter, wireless ac voltage meter,
wireless dc voltage meter, 3 test leads, alligator clips, and 3 magnetic hanging straps
FLK-3000FC HVAC System Wireless multimeter, wireless ac current clamp meter, wireless temperature meter, test
leads, alligator clips, K-type thermocouple, and magnetic hanging strap
FLK-Ti400 60HZ/FCA iFlex® Kit Infrared camera, ac power supply and battery pack charger (including mains
adapters), 2 lithium ion smart battery packs, micro SD memory card, USB cable,
HDMI video cable, hard carrying case, soft transport bag, adjustable hand strap,
international adapter set (9 Hz only), wireless multimeter, wireless iFlex A AC current
module, test leads, alligator clips, flexible current probe, magnetic hanging strap, and
soft case
FLK-Ti400 9HZ/FCA iFlex Kit
FLK-A3000FC Kit, Wireless
AC Current Clamp Kit
Wireless multimeter, wireless ac current clamp meter, test leads, alligator clips, and
magnetic hanging strap
FLK-A3001FC Kit, Wireless
iFlex® AC Current Clamp Kit
Wireless multimeter, wireless iFlex ac current meter, test leads, alligator clips,
magnetic hanging strap
FLK-V3000FC Kit, Wireless
AC Voltage Kit
Wireless multimeter, wireless ac voltage meter, 2 test leads, 2 alligator clips, and
magnetic hanging strap
FLK-V3001FC Kit, Wireless
DC Voltage Kit
Wireless multimeter, wireless dc voltage meter, 2 test leads, 2 alligator clips, and
magnetic hanging strap
FLK-V3003FC Kit, Wireless
AC/DC Voltage Measurement Kit
Wireless multimeter, ac voltage meter, dc voltage meter, hanging strap with magnets,
3 test leads, 4 alligator clips, info pack, and soft case
Fluke Connect
14
NEW PRODUCTS
www.fluke.com/infraredcameras
Fluke Infrared Cameras
Expert Series: TiX500
Tablet-sized screen. More details. Faster decisions.
See more details on the tablet-sized 5.7 inch screen, so you can easily make decisions in the
field. Get maximum ergonomics and easily maneuver over, under and around targets with the
240° rotating lens. Go from being completely out-of-focus to clear accurate and in focus with
MultiSharp™ Focus which captures multiple images and combines them to create one in focus
image. Get instant focus with laser driven target detection only with LaserSharp® Auto Focus.
Make decisions in the field.
See small details in the image and discover anomalies faster on the 5.7 inch tablet sized
touchscreen—the largest in its class
Edit and analyze images on camera—edit emissivity, enable color alarms and markers, and
adjust IR-Fusion® visual and infrared image blending
Wirelessly sync images directly from your camera to the Fluke Connect® app on your smart-
phone, and attach to an asset record or work order.
Inspect hard to reach targets.
Easily maneuver over, under and around objects with the 240° rotating lens while viewing
the screen at a comfortable angle
See the details you need from far away, with interchangeable smart lenses—2x and 4x tele-
photo, wide angle, and 25 micron macro—no calibration required
Focus near and far in a single image.
Capture a clear, accurate image focused throughout the field of view with MultiSharp
Focus. Simply point and shoot—the camera automatically processes a stack of images
focused near and far
Get an instant in-focus image of your target. LaserSharp® Auto Focus uses a built-in laser
distance meter that calculates and displays the distance from your designated target with
pinpoint accuracy
Professional Series: Ti450
100% focused –every object, near and far
The Fluke Ti450 Infrared Camera with MultiSharp Focus delivers images focused throughout
the camera’s field of view, get 4x's the pixel data with SuperResolution, and wirelessly syncs
images from the camera to the cloud for attachment to assets or work orders.
Capture a clear, accurate image focused throughout the field of view with MultiSharp Focus.
Simply point and shoot—the camera automatically processes a stack of images focused near
and far
Get an instant in-focus image of your designated target. LaserSharp® Auto Focus, exclusive
to Fluke, uses a built-in laser distance meter that calculates and displays the distance from
your designated target with pinpoint accuracy
Get 4x the pixels with SuperResolution to create a 640 x 480 image
Save time—wirelessly sync images directly from your camera to the Fluke Connect system,
and attach to an asset record or work order
Get the context of the visual and infrared details all in one precisely blended or picture-in-
picture image with IR-Fusion® technology
Monitor processes with video recording, video streaming, and remote control
See the details you need with interchangeable smart lenses—2x and 4x telephoto and wide
angle—no calibration required
Get tough shots from any
angle with a 240° degree
rotating lens and the only
5.7 inch LCD in its class.
MultiSharp™ Focus produces
an image focused throughout
the field of view.
New Products
15
NEW PRODUCTS
www.fluke.com/infraredcameras
Fluke Infrared Cameras
Performance Series: TiS75
High performance manual focus 320 x 240 infrared camera
Professional quality images with features that help you easily and quickly both see and solve
the problem.
Quality 320 x 240 images with manual focus, get crisp images from as close as 0.15 m (6 in)
See the location of the issue with blended IR and visual light images with 5MP visual light
camera—patented IR-Fusion® technology
Make decisions in real time – wirelessly sync images from your camera, create and email
reports all with your smart phone and the Fluke Connect® app.
Wirelessly connect to other Fluke Connect tools1
Removable 4GB micro SD card
Voice annotation
Smart battery with LED charge indicator
Specifications
TiX500 Ti450 TiS75
Detector resolution 320 x 240
640 x 480 Super Resolution mode 320 x 240
IFOV (spatial resolution) 1.31 mRad 2.0 mRad
Field of view 24 °H x 17 °V 35.7 °H x 26.8 °V
Focus system MultiSharp™ Focus, LaserSharp® Auto Focus with
built-in laser distance meter and advanced manual focus Manual focus
Wireless connectivity Fluke Connect app compatible
IR-Fusion technology Yes, blended visual and infrared images
Display 5.7 inch touchscreen LCD 3.5 inch touchscreen LCD 3.5 inch LCD
Design
Ergonomic FlexCam design
with a 240 degree
rotating lens
Rugged, ergonomic design
for one-handed use
Rugged, lightweight,
ergonomic design for one-
handed use
Temperature
measurement range
-20 °C to +650 °C
(-4 °F to +1202 °F)
-20 °C to +1200 °C
(-4 °F to +2192 °F)
-20 °C to +550 °C
(-4 °F to +1022 °F)
Thermal sensitivity
≤ 0.05 °C at 30 °C
target temp (50 mK)
≤ 0.05 °C at 30 °C
target temp (50 mK)
Filter Mode:
≤ 0.03 °C at 30 °C
target temp (30mK)
≤ 0.08 °C at 30 °C
target temp (80 mK)
Frontline troubleshooting
at 320 x 240 resolution.
Wirelessly sync images
directly from your camera
to the Fluke Connec
system with your
smartphone
Ordering information
Models Included accessories
FLK-TiX500 9 Hz Infrared Camera; 320 x 240 AC power supply, battery pack charger (including universal ac
adapters), two rugged lithium ion smart battery pack, USB cable,
HDMI video cable; micro SD card, rugged, hard carrying case,
adjustable neck and hand straps, and Bluetooth headset (where
available)
FLK-TiX500 60 Hz Infrared Camera; 320 x 240
FLK-Ti450 9 Hz Infrared Camera; 320 x 240 AC power supply, battery pack charger (including universal ac
adapters), two rugged lithium ion smart battery packs, USB cable,
HDMI video cable, 4GB micro SD card, rugged, hard carrying case,
soft transport bag, and adjustable hand strap
FLK-Ti450 60 Hz Infrared Camera; 320 x 240
FLK-TiS75 9 Hz Infrared Camera; 320 x 240 AC power supply, battery pack charger (including universal ac
adapters), two rugged lithium ion smart battery packs, USB cable,
micro SD card, rugged, hard carrying case, soft transport bag, and
adjustable hand strap
FLK-TiS75 30 Hz Infrared Camera; 320 x 240
1Fluke Connect® not available in all countries
New Products
16
NEW PRODUCTS
Fluke 154 HART Calibration Assistant
HART Calibration assistance at your fingertips.
Combine with a Fluke calibrator for a total HART calibration solution.
The Fluke 154 is a standalone tablet based HART® communication tool. The tablet
configured with the “Fluke HART” mobile app utilizes a wireless HART modem that
connects directly to the HART transmitter being tested or configured. When you combine
your Fluke 154 HART Calibration Assistant with a Fluke 750 Series Documenting Process
Calibrator, or a 720 Series Multifunction Process Calibrator you have a complete HART
calibration and configuration solution.
The 154 puts HART device configuration at your fingertips. An Android™-based tablet user
interface makes HART configuration easy. The external wireless modem allows you to connect
the modem to the transmitter being tested so you can communicate to the device remotely.
HART transmitters can often be found in confined spaces that are difficult to access, or are out
of reach. The Fluke 154 helps reduce the need to stand right next to the device being tested
or configured so you can work from a safer, more convenient location.
Fluke 154 features:
Full HART Device Description (DD) of all HART devices
Configure HART devices
Perform HART trim on HART devices when used with a Fluke 750, or 720 series calibrator
Monitor device PV, SV, TV, QV and other measured HART variables
Quarterly HART DD updates for free
Convenient wireless connectivity to HART modem
Easy to use, fast connect and view HART data
Store HART device configurations
Long range wireless communication up to 76.2 m (250 ft)
Multiple language support:
Select language from the Android operating system. Hart communication commands are
limited to English per the HART device descriptions.
Wireless HART Modem:
Includes configurable connection cable that accepts either the hook clips for connecting to
wires or the extended tooth alligator clips designed to connect to transmitter connection
screw heads. Rechargeable lithium-ion battery lasts easily for several days of HART device
configuration and testing activities. Rugged enclosure and test lead set designed for process
environments
Store device configurations:
Store HART device configurations in ASCII or PDF file configurations.
HART support:
Complete access to all features of the HART device’s DD including methods. Meets HART
physical layer specification: HCF_SPEC-54
DD updates:
Download free DD updates from Fluke.com for 3 years. Updates available when DD updates
released from the HART FieldComm group (approximately four times a year).
Hard side case:
Protects and stores tablet, modem, test leads and connection cable in a lightweight durable
tote that is easy to carry.
Ordering information
Models Included
FLK-154 HART Calibration
Assistant
Tablet, tablet charger and USB, micro-cable, Fluke HART App. (installed), HART modem,
USB mini-cable, proof of purchase for product activation, hook test clips, alligator clips,
magnetic hanging strap, case, manual installed on tablet, and three-year warranty
New Products www.fluke.com/154
17
NEW PRODUCTS
www.fluke.com/PRV240
Fluke PRV240 Proving Unit
Unique, compact, convenient
The Fluke PRV240 Proving Unit is a portable, pocket-sized, battery-powered voltage source. It
is unique in that it sources stable ac and dc voltages for both LoZ and HiZ instruments.
Designed for safety and compliance
The Fluke PRV240 provides a safe method to verify that your electrical test tool is operating
properly before you conduct any live tests. The concept of “Test Before Touch” (TBT) involves
testing your meter against a known live source before and after the actual measurement. This
sequence verifies that your test tool is operating properly during the actual measurement.
Verify your test tool without unnecessary exposure to shock and arc flash. Using the PRV240
reduces the need for personal protective equipment (PPE) when a known voltage source is not
available for verification of your tester or multimeter before test before TBT are performed. PPE is
still needed for absence of voltage testing when appropriate.
Key benefits
Using the PRV240 reduces the risk of shock and arc flash by validating the functionality of
test tools without placing yourself in a potentially hazardous electrical environment
Sources both ac and dc steady-state voltagesupplies 240 V dc/ac
A single LED indicates functionality, making this unit a simple-to-use solution for complying
with TBT verification of your test tool
Compatible with both high impedance or low impedance multimeters, clamp meters or two
pole testers
Voltage is sourced through recessed contacts that are activated when tested probes are
inserted to avoid accidental contact
Includes TPak™ Magnetic Hanging Strap
Long battery life5,000 tests per set of four AA batteries
Specifications
General specifications
Output voltage 240 V ac rms or dc ± 10 % ≥ 1 MΩ
LoZ >3 kΩ load 60 V ac typical
50 V ac rms minimum
LED power indicator Turns on when output voltage is present
Battery 4 AA Alkaline batteries NEDA, 24 A IEC LR03
Battery life 5000 (5-second duration) test cycles with >1 MΩ load, 300 tests minimum with
> 3 kΩ load
Operating temperature -10 °C to +50 °C (32 °F to 95 °F)
Operating humidity 0 % to 90 % (0 °C to 35 °C) 0 % to 70 % (35 °C to 55 °C, 95 °F to
131 °F)
Operating altitude 2000 m
Dimensions 11.7 cm x 7.4 cm x 2.8 cm (4.6 in x 2.9 in x 1.1 in), Pollution Degree 2
Weight 0.23 kg (8 oz) includes batteries
Safety EN 61010-1, EN 61010-2-030
Warranty One-year
Electromagnetic
Compatibility (EMC)
EN 61326-1 Portable EM environment; CISPR 11,
Group 1, Class A
US (FCC) 47 CFR 15 subpart B, this product is
considered an exempt device per clause
15.103
Korea (KCC) Class A Equipment (Industrial
Broadcasting & Communication
Equipment)
This product meets requirements for industrial (Class A) electromagnetic wave
equipment and the seller or user should take notice of it. This equipment is
intended for use in business environments and not to be used in homes.
Ordering information
Models Included accessories
PRV240 Proving Unit TPAK hanging strap, four AA batteries, instruction sheet
New Products
18
Models
Advanced meters Wireless meters General purpose
87 V 289 287 233 3000 FC 179
Basic features
Counts 20000 50000 50000 6000 6000 6000
True-rms readings ac ac+dc ac+dc ac ac ac
Basic dc accuracy 0.05 % 0.025 % 0.025 % 0.25 % 0.09 % 0.09 %
Wide bandwidth 20 kHz 100 kHz 100 kHz
Auto/manual ranging / / / / / /
ATEX II 2G Eex ia IICT4 safety rating Z1/Z2
Measurements
Voltage ac/dc 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V
Current ac/dc 10 A 10 A 10 A 10 A 400 mA 10 A
Resistance 50 M 500 M 500 M 40 M 50 M 50 M
Frequency 200 kHz 1 MHz 1 MHz 50 kHz 100 kHz 100 kHz
Capacitance 10,000 µF 50,000 µF 50,000 µF 10,000 µF 10,000 µF 10,000 µF
Temperature +10 9 0 ° C +1350 °C +1350 °C +400 °C +400 °C
dB 60 dB 60 dB
Conductance 50 nS 50 nS 50 nS
Duty cycle/pulse width /– / /
Continuity/diode test ••••••
Motor Drive (ASD) Measurements
VoltAlert, non-contact voltage detection
VCHEK
LoZ: low input impedance
Lo ohms
Microamps •••
Display
Removable wireless display
Remote wireless readings, connects to smart phone
(with ir3000 FC
connector, sold
separately)
(with ir3000 FC
connector, sold
separately)
Dot matrix display
Dual display
Analog bargraph
Backlight Two level Two level Two level •••
Graphical trend display
Diagnostics and data
Min/Max recording with time stamp /– / / /– /– /–
Fast Min/Max 250 µs 250 µs 250 µs
Display Hold/Auto (Touch) Hold / / / / / /
Relative reference •••
Stand alone logging (with FC app)
Trend Capture (with FC app)
Readings memories 10,000 10,000 (with FC app)
USB interface
Other features
Real time clock
Automatic selection, ac/dc volts
Closed case calibration ••••••
Separate battery/fuse access /– / /•••
Automatic power off ••••••
Low battery indication ••••••
Operating temperature range -20 °C, +55 °C -20 °C, +55 °C -20 °C, +55 °C -10 °C, +50 °C -10 °C, +50 °C -10 °C, +50 °C
Warranty and electrical safety
Warranty (years) Limited lifetime Limited lifetime Limited lifetime 3 3 Lifetime
Input alert •••
IP Rating IP30 IP54
Safety rating (EN 61010) CAT III 1000 V 1000 V 1000 V 1000 V 1000 V 1000 V
Safety rating (EN 61010) CAT IV 600 V 600 V 600 V 600 V 600 V 600 V
Digital multimeter selection guide
www.fluke.com/dmm
Digital Multimeters
19
Models
Compact meters Specialty meters
117 116 115 114 113 28 II 27 II 28IIEX 279 FC
Basic features
Counts 6000 6000 6000 6000 6000 20000 6000 20000 6000
True-rms readings ac ac ac ac ac ac ac ac
Basic dc accuracy 0.5 % 0.5 % 0.5 % 0.5 % 0.5 % 0.05 % 0.1 % 0.05 % 0.09 %
Wide bandwidth 20 kHz 30 kHz 20kHz
Auto/manual ranging / / / / / / / / /
ATEX II 2G Eex ia IICT4 safety rating Z1/Z2
Measurements
Voltage ac/dc 600 V 600 V 600 V 600 V 600 V 1000 V 1000 V 1000 V 1000 V
Current ac/dc 10 A 600 µA 10 A 10 A 10 A 10 A 2500 A AC
(with iFlex)
Resistance 40 MΩ 40 M 40 M 40 M 60 k 50 M 50 MΩ 50 M 50 M
Frequency 100 kHz 100 kHz 100 kHz 200 kHz 200 kHz 200 kHz 100 kHz
Capacitance 10,000 µF 10,000 µF 10,000 µF 10,000 µF 10,000 µF 10,000 µF 10,000 µF 10,000 µF
Temperature +400 °C +109 0 °C +109 0 °C Infrared
camera
-10 °C to
+200 °C
dB
Conductance 60 nS 60 nS 60 nS
Duty cycle/pulse width /– /– /–
Continuity/diode test •••••••••
Motor Drive (ASD) Measurements
VoltAlert, non-contact voltage detection
VCHEK
LoZ: low input impedance
Lo ohms
Microamps
Display
Removable wireless display
Remote wireless readings, connects
to smart phone
Dot matrix display
Dual display
Analog bargraph ••••••••
Backlight ••••Two level Two level Two level
Graphical trend display
Diagnostics and data
Min/Max recording with time stamp /– /– /– /– /– /– /– /– /–
Fast Min/Max 250 µs 250 µs
Display Hold/Auto (Touch) Hold /– /– /– /– /– / / / /
Relative reference •••
Stand alone logging (with FC app)
Trend Capture (with FC app)
Readings memories (with FC app)
USB interface
Other features
Real time clock
Automatic selection, ac/dc volts
Closed case calibration •••••••••
Separate battery/fuse access •••••//–
Automatic power off •••••••••
Low battery indication •••••••••
Operating temperature range -10 °C,
+50 °C
-10 °C,
+50 °C
-10 °C,
+50 °C
-10 °C,
+50 °C
-10 °C,
+50 °C
-40 °C,
+55 °C
-40 °C,
+55 °C
-15 °C,
+50 °C
-15 °C,
+50 °C
Warranty and electrical safety
Warranty (years) 3 3 3 3 3 Limited
lifetime
Limited
lifetime
3 3
Input alert •••
IP Rating IP42 IP42 IP42 IP42 IP42 IP67 IP67 IP67 IP40
Safety rating (EN 61010) CAT III 600 V 600 V 600 V 600 V 1000 V 1000 V 1000 V 1000 V
Safety rating (EN 61010) CAT IV 600 V 600 V 600 V 600 V 600 V
Find how-to videos, application notes, and other useful resources on the digital multimeter product pages on www.fluke.com
www.fluke.com/dmm Digital Multimeters
20
Ordering information
Models Included accessories
FLK-3000FC FC Wireless Digital Multimeter Test leads, alligator clips, holster, AA batteries installed,
information packet
True Made in
the U.S.
with
imported
parts
Fluke 3000 FC True-rms Wireless Multimeter
Reduce the risk of arc flash and stay safe
The Fluke 3000 FC True-rms Wireless Multimeter and Fluke Connect wireless test tools keep
you safe from hazardous measurement situations. Just deenergize the cabinet, open the panel
while wearing PPE and connect the remote modules, whether they are voltage modules,
current clamps, flexible current loops or thermometers. Then, from a safe distance, read the
results on the 3000 FC True-rms Wireless Multimeter.
You can display the meter measurement, plus readings from up to three wireless modules.
Better still, the Fluke 3000 FC True-rms Wireless Multimeter can send measurement data to your
smartphone, so you can save and share measurements from the field with your team anytime,
from anywhere.
The Fluke 3000 FC True-rms Wireless Multimeter with the Fluke Connect® app has all the
essentials for convenient test and measurement troubleshooting.
AC and dc voltage measurements to 1000 V
AC and dc current with 0.01 mA resolution
Continuity, resistance, diode test, capacitance and frequency measurements
Min/Max recording
CAT III 1000 V, CAT IV 600 V; IP54
Specifications
Functions Range and resolution Basic accuracy
AC voltage 600.0 mV, 6.000 V, 60.00 V, 600.0 V, 1000 V 1.0 % + 3
DC voltage 600.0 mV, 6.000 V, 60.00 V, 600.0 V, 1000 V 0.09 % + 2
Continuity Meter beeps at < 25 Ω, beeper detects
opens or shorts of 250 μs or longer
Resistance 600 Ω, 600.0 Ω, 6.000 kΩ, 60.00 kΩ,
60.00 kΩ, 600.0 kΩ, 50.00 MΩ 0.5 % + 1
Diode test 2.000 V 1 % + 2
Capacitance 1000 nF, 10.00 μF, 100.0 μF, 9999 μF11.2 % + 2
mA AC (45 Hz to 1 kHz) 60.00 mA, 400.0 mA31.5 % + 3
mA dc260.00 mA, 400.0 mA30.5 % + 3
Frequency 0.01 Hz, 0.1 Hz, 0.001 kHz, 0.01 kHz 0.1 % + 1
1In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2 % + 2.
2Input burden voltage (typical): 400 mA input 2 mV/mA.
3400.0 mA accuracy specified up to 600 mA overload.
For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C,
with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ± ([ % of Reading ] + [ Number of least
significant digits ]). (Not compatible with Fluke CNX test tools)
Digital Multimeters
DIGITAL MULTIMETERS
www.fluke.com/dmm
Kits—buy more, save more Recommended accessories
FC Wireless v3003 AC-DC
Voltage Measurement Kit
FC Wireless t3000
Temperature Kit
TL175 TwistGuard
Test Leads C3004 Soft Case
21
Fluke 170 Series Digital Multimeters
Maintenance experts can find most electrical and HVAC problems
The Fluke 170 Series True-rms Multimeters is simple to use with significant improvements
over the original Fluke 70 Series.
Wide 1000 V measurement range
True-rms for precise measurement of non-linear signals
Capacitance, resistance, continuity and frequency
Built-in thermometer (Fluke 179 only)
Backlight for work in dimly lit areas (Fluke 177 and 179 only)
Min/Max/Avg to record signal fluctuations
Display hold and auto hold
Manual and automatic ranging
Basic dc accuracy (179/0.09 %, 177/0.09 %, 175/0.15 %)
Also available: 177 with true-rms and backlight and 175 with true-rms
Ordering information
Models Included accessories
FLUKE-179 Digital Multimeter Test leads, temperature probe, 9 V battery (installed),
manual
FLUKE-177 Digital Multimeter Test leads, 9 V battery (installed), manual
FLUKE-175 Digital Multimeter Test leads, 9 V battery (installed), manual
Specifications
Functions Range and resolution Best accuracy
DC voltage 600.0 mV, 6.000 V, 60.00 V, 600.0 V, 1000 V ± 0.09 % (Models 177 and 179)
± 0.15 % (Model 175)
AC voltage1600.0 mV, 6.000 V, 60.00 V, 600.0 V, 1000 V ± 1.0 % of reading
DC current 60.00 mA, 400.0 mA, 6.000 A, 10.00 A2± 1.0 % of reading
AC current2 60.00 mA, 400.0 mA, 6.000 A, 10.00 A2± 1.5 % of reading
Resistance 600.0 W, 6.000 kW, 60.00 kW,
600.0 kW, 6.000 MW, 50.00 MW± 0.9 % of reading
Capacitance 1000 nF, 10.00 µF, 100.0 µF, 9999 µF ± 1.2 % of reading
Frequency399.99 Hz, 999.9 Hz, 9.999 Hz, 99.99 kHz ± 0.1 % of reading
Temperature (179 only) -40 ºC to +400 ºC (-40 ºF to +752 ºF) 1.0 % of reading
Battery life 200 hours typical for alkaline
Dimensions (HxWxL) 4.3 cm x 9.0 cm x 18.5 cm (1.7 in x 3.5 in x 7.3 in)
1All ac voltage and ac current ranges are specified from 5 % of range to 100 % of range.
210 A continuous, 20 A for up to 30 seconds.
3Voltage frequency is specified from 2 Hz to 100 kHz. Current frequency is specified from 2 Hz to 30 kHz.
True Made in
the U.S.
with
imported
parts
Instrument CarePlan
Digital Multimeters
DIGITAL MULTIMETERS
www.fluke.com/dmm
Kits—buy more, save more Recommended accessories
179/EDA2 Electronics Multimeter
and Deluxe Accessory Combo Kit
TLK-225
SureGripMaster
Accessory Set C25 Meter Case
22
Fluke 289 and 287 True-rms Logging Multimeters
Find little problems before they become big ones
The Fluke 289 and 287 are high performance industrial logging multimeters. The large
50,000 count, 1/4 VGA dot matrix display and multiple on screen displays give you sharp,
clear readings. Use the logging function with expanded memory for unattended monitor-
ing of signals over time. With on-board TrendCapture, you can graphically review up 10,000
recorded events and logged readings. Then, zoom on trend provides an unprecedented ability
to zoom in up to 14 times to view and analyze data—all without needing a PC.
Two terminal 50 ohm range with 1 milliohm resolution, 10 mA source current.
Useful for measuring and comparing differences in motor winding resistance or contact
resistance (289)
Low-pass filter for accurate voltage and frequency measurements on adjustable speed motor
drives and other electrically noisy equipment (289)
Add the wireless data logging capabilities of Fluke Connect® with Share-Live video call
with the if3000 FC connector
True-rms ac bandwidth 100 kHz; dBV/dBm; dc mV resolution 1 μV; Megohm range up to
500 MΩ
Conductance 50.00 nS
Min/Max/Avg/duty cycle/pulse width
Isolated optical DMM interface with USB PC connection
Over 200 hours logging capacity with new power saving function
Lo Ohm capability; Lo Z volts; Lo Pass Filter
Ordering information
Models Included accessories
FLUKE-289 True-rms Industrial Logging Multimeter with
TrendCapture
Test leads, alligator clips, holster, AA batteries installed,
information packet
FLUKE-287 True-rms Electronics Logging Multimeter
with TrendCapture
Test leads, alligator clips, holster, AA batteries installed,
information packet
Specifications
Functions Range and resolution Basic accuracy
AC or dc voltage 50.000 mV, 500.00 mV, 5.0000 V,
50.000 V, 500.00 V, 1000.0 V
0.025 %
0.4 % (true-rms) (ac)
AC current dc current 500.00 µA, 5000.0 µA, 50.000 mA,
400.00 mA, 5.0000 A, 10.000 A
0.15 %
0.7 % (true-rms)
Temperature
(excluding probe)
-200.0 °C to 1350.0 °C (-328.0 °F to 2462.0 °F) 1.0 %
Resistance 50.000 Ω, 500.00 Ω, 5.0000 kΩ, 50.000 kΩ, 500.00 kΩ,
5.0000 MΩ, 50.00 MΩ, 500.0 MΩ 0.05 %
Capacitance 1.000 nF,10.00 nF, 100.0 nF, 1.000 µF, 10.00 µF,
100.0 µF, 1000 µF, 10.00 mF, 100 mF 1.0 %
Frequency 99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz .005 %
True Made in
the U.S.
with
imported
parts
Instrument CarePlan
Digital Multimeters
DIGITAL MULTIMETERS
www.fluke.com/dmm
Kits—buy more, save more Recommended accessories
289/FVF True-rms Industrial
Logging Multimeter Combo Kit
with TrendCapture
TL175 TwistGuard
Test Leads
ir3000 FC
Connector
23
Ordering information
Models Included accessories
FLUKE-87-5 Industrial True-rms Multimeter with
Temperature
Test leads, alligator clips, holster, batteries (installed),
temperature probe (87V only), information packet
FLUKE-83-5 Industrial Multimeter Test leads, alligator clips, holster, batteries (installed),
temperature probe (87V only), information packet
Specifications
Functions Range and resolution
Basic accuracy
87V 83V
DC voltage 600.0 mV, 6.000 V, 60.00 V, 600.0 V, 1000 V 0.05 % 0.1 %
AC voltage 600.0 mV, 6.000 V, 60.00 V, 600.0 V, 1000 V 0.7 % (true-rms) 0.5 %
DC current 600.0 µA, 6000 µA, 60.00 µA, 600.O mA, 6.000 A,
10.00 A 0.2 % 0.4 %
AC current 600.0 µA, 6000 µA, 60.00 µA, 600.O mA, 6.000 A,
10.00 A 1.0 % (true-rms) 1.2 %
Temperature
(excluding probe) -200 °C to 1090 °C (-328 °F to 1994 °F) 1.0 %
Temperature
probe -40 °C to 260 °C (-40 °F to 500 °F) 2.2 °C or 2 %
Resistance 600.0 Ω, 6.000 kΩ, 60.00 kΩ, 600.0 kΩ, 6.000 MΩ,
50.00 MΩ 0.2 % 0.4 %
Capacitance 10.00 nF, 100.0 nF, 1.000 µF, 10.00 µF, 100.0 µF,
9,999 µF 1.0 % 1.0 %
Frequency 199.99 Hz, 1.9999 kHz, 19.999 kHz, 199.99 kHz 0.005 % 0.005 %
Battery life 400 hours typical with backlight off
Dimensions
(LxWxD)/Weight 201 mm x 98 mm x 52 mm (7.9 in x 3.8 in x 2 in)/355 g (22 oz)
Fluke 87V Industrial Multimeters
The perfect DMM for a heavy industrial environment
The Fluke 87V Industrial Multimeter has measurement functions, trouble-shooting features,
resolution and accuracy to solve industrial problems on motor drives, in-plant automation,
power distribution and electro-mechanical equipment. The Fluke 87V Industrial Multimeter
offers a unique function for accurate voltage and frequency measurements on adjustable speed
motor drives and electrically noisy equipment. The large digit display with a bright, two level
backlight makes it significantly easier to read.
Electrical safety
All inputs are protected to CAT III 1000 V and CAT IV 600 V. They can withstand impulses in
excess of 8,000 V to help protect you from arc blast resulting from surges and spikes.
Measure 20 A for up to 30 seconds, 10 A continuously
Expanded capacitance range to 10,000 μF
Peak capture to record transients as fast as 250 μs
Measure up to 1000 V ac and dc
Auto and manual ranging for maximum flexibility
Frequency to 200 kHz and % duty cycle
Min/Max/Avg recording to capture variations automatically
Relative mode to remove test lead resistance from low ohms measurements
Also available as 83V average responding multimeter
True Made in
the U.S.
with
imported
parts
Instrument CarePlan
Digital Multimeters
DIGITAL MULTIMETERS
www.fluke.com/dmm
Kits—buy more, save more Recommended accessories
87V/E2 Industrial
Electrician’s Combo Kit
AC285 SureGrip
Alligator Clips
CXT80
Extreme Case
24 24
Fluke 27 II, 28 II and 28 II Ex Digital Multimeters
Designed for tough work environments
The 27 II, 28 II and 28 II Ex Digital Multimeters all have IP67 waterproof and dustproof rating.
They also have an extended operating temperature range of -15 °C to +55 °C (5 °F to 131 °F)
and 95 % humidity. These meters offer unique functions for accurate voltage and frequency
measurements on adjustable speed motor drives and electrically noisy equipment (28 II and
28 II Ex). A built in thermometer allows you to take temperature readings without having to
carry a separate instrument.
Resistance and continuity. Relative mode to remove test lead resistance from low ohms
measurements
MSHA, CSA and TÜV approvals (27 II, 28 II)
Intrinsically safe certifications from the world’s leading certification bodies (28 II Ex, pg 67)
Tested to withstand a 3 m (10 ft) drop
Wide 1000 V measurement range
True-rms ac voltage and current for accurate measurements on non-linear signals
(28 II, 28 II Ex)
Low pass filter (28 II, 28 II Ex)
Average responding voltage and current measurements (27 II)
10 A continuous (20 A for 30 seconds)
Frequency and capacitance
Record signal fluctuations using the Min/Max function
Ordering information
Models Included accessories
FLUKE-28-II Industrial Multimeter Test leads, temperature probe, alligator clips, batteries,
holster, information pack
FLUKE-28-II EX Intrinsically Safe Industrial Multimeter
See page 67 for more information
Test leads, temperature probe, alligator clips, batteries,
holster, information pack
FLUKE-27-II Industrial Multimeter Test leads, temperature probe, alligator clips, batteries,
holster, information pack
Specifications
27 II 28 II 28 II Ex
Volts ac, dc 1000 V
Amps ac, dc 10A
Resistance 0.1 0 to 50 MΩ
Display counts 6000 6000/19,999 6000/19,999
Temperature -200 °C to +1090 °C -200 °C to +1090 °C
Low pass filter (measurement on VSD’s)
Safety rating (EN 61010) CAT IV 600 V, CAT III 1000 V
Measurement method Avg. responding True-rms True-rms
Power Three AA batteries
Battery life 800 hours 400 hours
Dimensions (DxWxH) 6.35 cm x 10.0 cm x 19.81 cm (2.5 in x 3.93 in x 7.8 in)
Weight with holster 698.5 g (l.54 lb)
MSHA
United States Department of Labor
Mine Safety and Health Administration
True Made in
the U.S.
with
imported
parts
Instrument CarePlan
Digital Multimeters
Recommended accessories
TLK-225 SureGrip Master
Accessory Set
PV350 Pressure-Vacuum
Module
TL225 Stray Voltage
Adapter Test Lead Kit C550 Tool Bag
DIGITAL MULTIMETERS
www.fluke.com/dmm
25
Ordering information
Models Included accessories
FLUKE-233 Remote Display Multimeter Test leads, temperature probe, alligator clips, batteries,
information pack
Fluke 233 Remote Display Digital Multimeter
Now, you can be in two places at once
The Fluke 233 Remote Display Digital Multimeter has a removable display that solves several
problems. First, you no longer have to hold both the meter and the test leads to make a
measurement. Second, it allows you to measure where the measurement point is separated
from controls or where the operator can’t stay close to the meter during measurements due to
various hazards or moving machinery. Third, Fluke’s wireless technology allows the display
to be carried up to 9 m (30 feet) away from the point of measurement for added flexibility and
the removable magnetic display can be conveniently mounted where it is easily seen.
Low-power 802.15.4 wireless technology does not interfere with measurement accuracy
Use as a conventional multimeter when the display is connected
True-rms ac voltage and current; built-in thermometer
Radio transmitter automatically turns off when the display is connected to the meter
Record signal fluctuations using the Min/Max function
Measure up to 1000 V ac and dc
Measure up to 10 A (20 A for 30 seconds)
10,000 μF capacitance range
Frequency up to 50 kHz
Resistance, continuity and diode test
Min/Max/Avg recording to capture variations automatically
New, improved battery life
Specifications
Functions Specifications
DC voltage Range 0.1 mV to 1000 V
Accuracy 0.25 % + 2
AC voltage Range 0.1 mV to 1000 V
Accuracy 1.0 % + 3
DC current Range 0.001 A to 10 A
Accuracy 1.0 % + 3
AC current Range 0.001 A to 10 A
Accuracy 1.5 % + 3
Resistance Range 0.1 Ω to 40 M
Capacitance 1000 nF to 9999 µF
Frequency 0.1 Hz to 50.00 kHz
Temperature -40 °C to +400 °C (-40 °F to 752 °F)
Power Three AA batteries main body, two AA batteries display module
Battery life 400 hours
Safety rating CAT IV 600 V, CAT III 1000 V
Size (HxWxL) 5.3 cm x 5.3 cm x 19.3 cm (2.08 in x 2.08 in x 7.6 in)
Weight 604 g (1.3 lb)
True Made in
the U.S.
with
imported
parts
Instrument CarePlan
Digital Multimeters
Recommended accessories
80PK-22
SureGrip Immersion
Temperature Probe
80AK-A Thermocouple
Adapter
TL220 SureGrip
Industrial Test Lead Set
TLK289 SureGrip Industrial
Master
Test Lead Set and Case
DIGITAL MULTIMETERS
www.fluke.com/dmm
26
Kits—buy more, save more Recommended accessories
117/323 Electrician’s Combo Kit 116 /62 M A X+ HVAC Combo Kit
TL175 TwistGuard
Test Leads
C115 Soft Carrying
Case
Fluke 11X Series True-rms Digital Multimeters
Dependable DMMs for electrical and HVAC purposes
The Fluke 117 Digital Multimeter includes integrated non-contact voltage detection to help
get the job done faster. The Fluke 115 Digital Multimeter is the solution for a wide variety of
electrical and electronic testing applications.
The Fluke 116 Digital Multimeter was specifically designed for the HVAC professional. The
Fluke 114 Digital Multimeter is the best troubleshooting tool for “go/no-go” testing and the 113
is a basic electrical and utility multimeter.
VoltAlert technology for integrated non-contact voltage detection (117)
AutoVolt feature for automatic ac/dc voltage selection (117, 116, 114)
Built in thermometer for HVAC applications (116)
Microamps to test flame sensors (116)
VCHEK LoZ low impedance measurement function to simultaneously test for voltage or
continuity (113)
LoZ: Low input impedance prevents false readings due to “ghost voltage” (117, 116, 114)
Min/Max/Avg to record signal fluctuations
Large display and white LED backlight to work in poorly lit areas more effectively
Compact ergonomic design for one-handed operation
True
Specifications
Functions 117 116 115 114 113
AC/DC voltage 600 V 600 V 600 V 600 V 600 V
AC/DC current 10 A 600.0 µA 10 A
Resistance 40 MW40 MW40 MW40 MW60 kW
Capacitance 1 nF to 9,999 µF 1 nF to 9,999 µF 1 nF to 9,999 µF
Diode test
Frequency 5 Hz to 99.99 kHz 5 Hz to 99.99 kHz 5 Hz to 99.99 kHz
Temperature +400 °C
Safety rating CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT IV 600 V
Ordering information
Models Included accessories
F L U K E -117 Multimeter with Non-Contact
Voltage Test leads, holster, users manual and 9 V battery (installed)
F L U K E -116 HVAC Multimeter with Temperature
and Microamps
Test leads, integrated temperature probe, holster, users manual and
9 V battery (installed)
F L U K E -115 Multimeter Test leads, holster, users manual and 9 V battery (installed)
F L U K E -114 Electrical Multimeter Test leads, holster, users manual and 9 V battery (installed)
F L U K E -113 Utility Meter Test leads, holster, users manual and 9 V battery (installed)
113 only
Digital Multimeters
DIGITAL MULTIMETERS
www.fluke.com/dmm
27
Made in
the U.S.
with
imported
parts
Made in
the U.S.
with
imported
parts
Fluke 88V and 77 IV Digital Multimeters
Fluke 88V Automotive Multimeterdesigned to help automotive professionals
solve problems faster
The Fluke 88V Automotive Multimeter has the measurement functions, troubleshooting
features and accuracy to solve virtually any problem with conventional and hybrid vehicles.
Automotive test functions include dc and ac voltage, resistance and current
Min/Max recording for logging the highest and lowest readings over time
Frequency measurements for magnetic sensors and ac/dc frequency signals
Duty cycle for variable duty cycle signals with selectable trigger, slope and level
Pulse width for fuel injector on-time measurements
Conductance testing for secondary ignition coils
RPM measurements for DIS and conventional ignition systems
Built-in thermometer
Fluke 77 IV Digital Multimeter—use to repair most electrical and electronic
problems
The Fluke 77 IV Digital Multimeter is simple to use and has significant improvements over
Fluke’s original 70 Series with more measurement functions, conformance to the latest safety
standards, and a much larger display that is easier to view.
Wide 1000 V measurement range
Average responding ac measurements
0.3 % accuracy
10 amps continuous
Frequency and capacitance
Resistance and continuity
Min/Max to record signal fluctuations
Auto and manual ranging
Specifications
88V 77IV
DC voltage 1000 V 1000 V
AC voltage 1000 V 1000 V
DC current 10 A 10 A
AC current 10 A 10 A
Resistance 50 MΩ 50 MΩ
Capacitance 9,999 μF 9,999 μF
Frequency 200.00 kHz 99.99 kHz
Duty Cycle 99.9 %
Temperature 1994.0 °F (1090 °C)
Conductance 60.00 nS
Ordering information
Models Included accessories
FLUKE-88-5 Automotive Multimeter Test leads, 9 V battery (installed), information packet
FLUKE-77-4 Digital Multimeter Test leads, 9 V battery (installed), information packet
Kits—buy more, save more Recommended accessories
88V/A Automotive Multimeter Combo Kit
TLK282 Deluxe
Automotive Test
Lead Kit (88V)
TLK-225 SureGrip
Master Accessory
Kit (77 IV)
C35 Soft Carrying
Case
Instrument CarePlan
Instrument CarePlan
Digital Multimeters
DIGITAL MULTIMETERS
www.fluke.com/dmm
www.fluke.com/clamps
Clamp meter selection guide
Residential/commercial electrical General purpose
323 324 325 365 373 374 FC
Measurements
AC current
AC voltage
Resistance •••
Continuity •••
DC volts
DC current
True-rms
Frequency
AC + DC voltage
AC + DC current
Min/Max/Avg
4-20 mA (0.01 mA resolution)
Temperature
Capacitance
Measurement logging
Special features
Inrush current mode
Low Pass filter for VFD's
Harmonics, power, data logging
18-inch (45.7 cm) iFlex Flexible
Current Probe Optional
10-inch (25.4 cm) iFlex Flexible
Current Probe Optional
Remote display in phone app
Wireless
Display
Display hold •••
Backlight
Graphing display in phone app
Specifications
Jaw opening 30 mm
(1.18 in)
30 mm
(1.18 in)
30 mm
(1.18 in)
18 mm
(0.7 in)
32 mm
(1.26 in)
34 mm
(1.33 in)
Max wire size 300 mm2300 mm2300 mm217 mm (0.67 in) 400 mm2400 mm2
Current range ac rms 0 to 400.0 A 0 to 40.00 A/
400.0 A
0 to 40.00 A/
400.0 A 0 to 200.0 A 0 to 600.0 A 0 to 600.0 A
(2500 A with iFlex)
Accuracy ac current (50/60 Hz) 2 %
± 5 counts
2 %
± 5 counts
2 %
± 5 counts
2 %
± 5 counts
2 %
± 5 counts
2 %
± 5 counts
AC Response True-rms True-rms True-rms True-rms True-rms True-rms
Current range dc 0 to 40.00 A/
400.0 A 0 to 200 A 0 to 600.0 A
Accuracy dc current 2 %
± 5 counts
2 %
± 5 counts
2 %
± 5 counts
Voltage range ac 0 to 600.0 V 0 to 600.0 V 0 to 600.0 V 0 to 600.0 V 0 to 600.0 V 0 to 1000 V
Accuracy ac voltage 1.5 %
± 5 counts
1.5 %
± 5 counts
1.5 %
± 5 counts
2 %
± 5 counts
1 %
± 5 counts
1.5 %
± 5 counts
Voltage range dc 0 to 600.0 V 0 to 600.0 V 0 to 600.0 V 0 to 600.0 V 0 to 600.0 V 0 to 1000 V
Accuracy dc voltage 1.0 %
± 5 counts
1.0 %
± 5 counts
1.0 %
± 5 counts
2 %
± 5 counts
1 %
± 5 counts
1 %
± 5 counts
Resistance range 0 to 4000 Ω 0 to 4000 Ω 0 to 40 kΩ 0 to 6000 Ω 0 to 6000 Ω 0 to 6000 Ω
Frequency measurement range 5 Hz to 500 Hz
Unit power
Auto off
Warranty and safety
Warranty (years) 2223 3 3
Safety rating (EN 61010) CAT IV 300 V,
CAT III 600 V
CAT IV 300 V,
CAT III 600 V
CAT IV 300 V,
CAT III 600 V CAT III 600 V CAT III 600 V,
CAT IV 300 V
CAT III 1000 V,
CAT IV 600 V
Fluke Connect
Compatible with Fluke Connect® app
Compatible with Fluke Connec
Assets software
Clamp Meters28
www.fluke.com/clamps
General
purpose Industrial electrical HVAC/R High-end industrial, utility Leakage Wireless
375 FC 376 FC 381 902 FC 353 355 368 FC/369 FC a3000 FC a3001 FC
•••••••
Optional Included Included Optional
Optional Optional Optional Included
in phone app in phone app in phone app in phone app in phone app in phone app
in phone app in phone app
in phone app in phone app in phone app in phone app in phone app in phone app
34 mm
(1.33 in)
34 mm
(1.33 in)
34 mm
(1.33 in)
30 mm
(1.2 in)
58 mm
(2.3 in)
58 mm
(2.3 in)
40 mm (1.5 in)/
61 mm (2.4 in)
34 mm
(1.33 in)
254 mm
(10 in) coil
400 mm2400 mm2400 mm2300 mm2400mm² or
3x 240 m
400mm² or
3x 240 m 400 mm2
0 to 600.0 A
(2500 A with
iFlex)
0 to 999.9 A
(2500 A with
iFlex)
0 to 999.9 A
(2500 A with
iFlex)
0 to 600.0 A 0 to 1400 A 0 to 1400 A 0 to 60 A 0 to 400A 0 to 2500A
2 %
± 5 counts
2 %
± 5 counts
2 %
± 5 counts
2 %
± 5 counts
1.5 %
± 5 counts
1.5 %
± 5 counts
1 %
± 5 counts
2 %
± 5 counts
3 %
± 5 counts
True-rms True-rms True-rms True-rms True-rms True-rms True-rms True-rms True-rms
0 to 600.0 A 0 to 999.9 A 0 to 999.9 A 0 to 200 µA 0 to 2000 A 0 to 2000 A
2 %
± 5 counts
2 %
± 5 counts
2 %
± 5 counts
1 %
± 5 counts
1.5 %
± 5 counts
1.5 %
± 5 counts
0 to 1000 V 0 to 1000 V 0 to 1000 V 600.0 V 0 to 600.0 V
1.5 %
± 5 counts
1.5 %
± 5 counts
1.5 %
± 5 counts
1 %
± 5 counts
1 %
± 5 counts
0 to 1000 V 0 to 1000 V 0 to 1000 V 0 to 600.0 V 0 to 1000 V
1 %
± 5 counts
1 %
± 5 counts
1 %
± 5 counts
1 %
± 5 counts
1 %
± 5 counts
0 to 6000 Ω 0 to 60 kΩ 0 to 60 kΩ 0 to 9999 Ω 0 to 400 kΩ
500 Hz 500 Hz 500 Hz 5 to 1000 Hz 5 to 1000 Hz 40 to 1000 Hz
3 3 3 3 3 3 1 3 3
CAT III 1000 V,
CAT IV 600 V
CAT III 1000 V,
CAT IV 600 V
CAT III 1000 V,
CAT IV 600 V CAT III 600 V CAT III 1000 V,
CAT IV 600 V
CAT III 1000 V,
CAT IV 600 V CAT III 600 V CAT III 600 V CAT III 1000 V
CAT IV 600 V
Find how-to videos, application notes, and other useful resources on the clamp meter product pages on www.fluke.com
Clamp Meters 29
30
Fluke 370 Series Clamp Meters
Unprecedented measurement flexibility
The Fluke 370 FC Series clamp meters offer advanced troubleshooting performance plus Fluke
Connect features to log and transmit data wirelessly.
Now you are able to log and trend measurements (the 376 FC and 375 FC have internal
memory for up to 65,000 measurements), capture measurements outside the arcflash zone
with Bluetooth® connectivity to your Apple® or Android® devices, transmit results wirelessly
via the Fluke Connect Measurements app, and create and send reports right from the field.
The Fluke 370 FC Series Clamp Meters have a large backlit display, true-rms standard, CAT IV
safety rating and a durably constructed body. Additionally, the 376 FC, 375 FC and 374 FC are
compatible with the iFlex® Flexible Current Probe that measure up to 2500a ac.
True
True
Ordering information
Models Included accessories
FLUKE-373 True-rms Wireless AC Clamp Meter Test leads, soft carrying case, instruction card, safety
information sheet, two AA alkaline batteries.
FLUKE-374 FC True-rms Wireless AC/DC Clamp Meter Test leads, soft carrying case, instruction card, safety
information sheet, two AA alkaline batteries.
FLUKE-375 FC True-rms Wireless AC/DC Clamp Meter Test leads, soft carrying case, instruction card, safety
information sheet, two AA alkaline batteries.
FLUKE-376 FC True-rms Wireless AC/DC Clamp Meter
with iFlex
18-inch (45.7 cm) iFlex flexible current probe, test leads, TPAK
magnetic hanging strap, soft carrying case, instruction card,
safety information sheet, two AA alkaline batteries.
Ordering information
Models Included accessories
FLUKE-325 True-rms Clamp Meter Test leads, temperature probe, soft case and users manual
FLUKE-324 True-rms Clamp Meter Test leads, temperature probe, soft case and users manual
FLUKE-323 True-rms Clamp Meter Test leads, soft case and users manual
Fluke 320 Series True-rms Clamp Meters
Go to work with the best
The small and rugged 320 Series True-rms Clamp Meters are the best general troubleshoot-
ing tools for commercial and residential electricians and are designed to verify the presence of
load current, ac voltage and continuity of circuits, switches, fuses and contacts. The Fluke 325
also offers dc current and frequency measurements.
400 A ac current measurement (ac and dc current; 325 only) and 600 V ac and dc voltage
measurement
Resistance measurement to up to 40 kΩ (325) and 4 kΩ (323 and 324) with continuity
CAT IV 300 V/CAT III 600 V safety rating
Recommended accessories
i2500-10
10 inch (25.4 cm)
iFlex® Flexible Current Probe C43 Small Soft Case
TL175 TwistGuard
Test Leads
L210 Probe Light and
Extender
Fluke 370 Series Fluke 370 Series Fluke 320 Series Fluke 320 Series
www.fluke.com/clamps
Clamp Meters
Find how-to videos, application notes, and other useful resources on the clamp meter product pages
on www.fluke.com
CLAMP METERS
31
Fluke 381 Remote Display True-rms
AC/DC Clamp Meter with iFlex®
The world’s most advanced clamp meter
The Fluke 381 Clamp Meter combines iFlex® flexibility with remote reading
capability for the ultimate in innovation and safety. The remote display
reads measurements up to 9 m (30 feet) away and the included iFlex Flexible
current probe (18-inch/45.7 cm circumference) lets you easily get into tight
spaces.
2500 A ac current measurement with iFlex
1000 A ac and dc current measurement with fixed jaw
1000 V ac and dc voltage measurement
Frequency measurement to 500 Hz
60 kΩ resistance measurement
Min/Max/Avg and inrush recording
CAT IV 600 V, CAT III 1000 V
Three-year warranty
Fluke 365 Detachable Jaw True-rms AC/DC
Clamp Meter
Where rugged meets reliable
The Fluke 365 Clamp Meter offers a small, detachable jaw—with 1.2 m of coil—that makes it
easy to take and read measurements in tight or hard-to-reach places.
200 A ac and dc current measurement
600 V ac and dc voltage measurement
6000 Ω resistance measurement
Built-in flashlight
Large, easy-to-read backlight display
Three-year warranty
True
True
Ordering information
Models Included accessories
FLUKE-365 Detachable Jaw True-rms AC/DC Clamp Meter Test leads, soft carrying case, instruction card, safety
information sheet, five AA alkaline batteries
Ordering information
Models Included accessories
FLUKE-381 Remote Display True-rms AC/DC Clamp Meter
with iFlex
18-inch (45.7 cm) iFlex Flexible Current Probe, test leads,
soft carrying case, instruction card, safety information
sheet, five AA alkaline batteries
Recommended accessories
AC285 SureGrip
Alligator Clips
TLK289 Industrial Master
Test Lead Set
TL220 SureGrip Industrial
Test Lead Set
FTPL-1 SureGrip Fused
Test Probe and Lead Set
Fluke 381 Fluke 381 Fluke 365 Fluke 365
Clamp Meters
www.fluke.com/clamps
CLAMP METERS
32
Recommended accessories
AC220 SureGrip Alligator
Clips AC175 Alligator Clip Set
TL224 SureGrip
Insulated Test Leads C33 Soft Carrying Case
www.fluke.com/clamps
Clamp Meters
Fluke 368 FC/369 FC AC True-rms Leakage
Current Clamp Meter
Reduce downtime – Test leakage currents without taking equipment offline
The Fluke 368/369 Series of true-rms leakage current clamp meters help users detect, docu-
ment, record and compare leakage current readings over time as a means of preventing
unplanned downtime, and identifying intermittent GFCI and RCD trips, all without taking
equipment off line.
Current measurement
Automatic ranging within the manually selected mA or A range
Ranges 3/30 mA and 30/60 A
Current resolution 1 µA/0.01 mA and 0.01 A/0.1 A
Selectable filter 40 Hz to 70 Hz or wideband 40 Hz to 1 kHz
Frequency range 40 Hz to 1 kHz
Jaw size: 40 mm (1.55 in) on 368 FC and 61 mm (2.4 in) on 369 FC diameter
Auto power off
Torch light
Logging
Fluke Connect compatible
Fluke 902 FC True-rms Wireless HVAC
Clamp Meter
Helps HVAC pros keep up with the demands of their job
HVAC technicians require a service tool they can depend on to consistently meet the
expectations of their job. The Fluke 902 FC expands the existing line of quality Fluke clamp
meters by delivering the features necessary to diagnose and repair HVAC systems. Combined
with Fluke Connect®, the Fluke 902 FC helps technicians do their jobs safely and accurately.
Capture and trend measurements safely from outside the arc blast zone and easily create
and send reports from the field with Fluke Connect®
Designed for HVAC applications with capacitance, dc current (µA) and temperature
measurements
Small body and jaws fit perfectly in your hand and into tight places
True-rms voltage and current for accurate measurements of non-linear signals
Three-year warranty
True
Ordering information
Models Included accessories
FLUKE-902 FC True-rms Wireless HVAC Clamp Meter Test leads, temperature probe, soft carrying case, users
manual, two AA alkaline batteries
Fluke 902
Ordering information
Models Included accessories
FLUKE-368 FC AC Leakage Current Clamp Meter Soft carrying case, users manual
FLUKE-369 FC AC Leakage Current Clamp Meter Soft carrying case, users manual
Fluke 902 Fluke 902 Fluke 902
CLAMP METERS
33
Ordering information
Models Included accessories
FLK-a3000 FC Wireless AC Current Clamp Meter Information pack
FLK-a3001 FC Wireless iFlex AC Current Meter iFlex current probe, information pack, magnetic hanger
FLK-a3002 FC Wireless AC/DC Current Meter Module Information pack, magnetic hanger
FLK-a3003 FC Wireless 2000 A DC Current Clamp Meter 2000 A DC Clamp, information pack, magnetic hanger
FLK-a3004 FC Wireless 4-20 mA DC Current Meter 4-20 mA DC current probe, information pack, hanging
strap
Clamp Meters
www.fluke.com/clamps
Wireless Fluke Connect® Current Meters
Take three-phase measurements in one-third of the time
Testing 3-phase is now faster and cheaper. When your cabinet is de-energized,
attach the 3000 FC Wireless Current Clamp to each phase. You can solve prob-
lems faster by seeing live measurements from multiple test points on a single
screen. Then, send data to your laptop and go from logging to analysis and
diagnosis using the Fluke Connect® app or Fluke Connect® Assets software.
Fluke a3000 FC Wireless AC Current Clamp Meter
A fully functional true-rms current clamp meter that wirelessly relays
measurements to other Fluke Connect® enabled master units.
Measure up to 400 A ac
Fluke a3001 FC Wireless iFlex AC Current Meter
A true-rms flexible current meter that wirelessly relays measurements to other
Fluke Connect enabled master units.
Record over time to monitor circuit load changes for an hour, a shift or a week
Measure up to 2500 A ac
Fluke a3002 FC Wireless AC/DC Current Meter Module
Measure up to 400 A ac or 400 A dc with i410 (sold separately)
Measure up to 600 A ac or 1000 A dc with i1010 (sold separately)
Use as a standalone meter or as part of the system
Fluke a3003 FC Wireless 2000 A DC Current Clamp Meter
Measure up to 2000 A DC
Large jaw size (64 mm) for measuring large, high current conductors
Use the logging function for the recording and saving up to 65,000 readings
Fluke a3004 FC Wireless 4-20 mA DC Current Meter
Measure 4 to 20 mA signals without “breaking the loop”
Detachable clamp with extension cable for measurements in tight locations
Use the logging function for the recording and saving up to 65,000 readings
Fluke a3004 FC Wireless
4-20 mA DC Current Meter
Fluke a3003 FC
Wireless 2000 A DC
Current Clamp Meter
CLAMP METERS
34
Fluke 350 Series
Ordering information
Models Included accessories
FLUKE-355 AC/DC True-rms Clamp Meter Soft carrying case, users manual
FLUKE-353 AC/DC True-rms Clamp Meter Soft carrying case, users manual
Fluke 350 Series Fluke 350 Series Fluke 350 Series
Fluke 353 and 355 AC/DC True-rms Clamp Meters
Versatile, professional, accurate
Confidently take reliable readings with the true-rms Fluke 355 and 353 Clamp Meters—the
tools of choice for high current clamp-on amp meter measurements up to 2000 A.
Reliably handle a wide range of high-current applications with 2000 A ac + dc true-rms,
1400 A ac, and 2000 A dc
High voltage measurement of 1000 V ac + dc true-rms, 600 V ac, and 1000 V dc (355 only)
Resistance to 400 kΩ (355 only)
Continuity beeper (355 only)
Frequency measurement to 1 kHz
Selectable low-pass filter mode
Min/Max/Avg
Recommended accessories
TL175 TwistGuard Test
Leads
80TK Thermocouple
Module C345 Large Soft Case C1600 Gear Tool Box
True
www.fluke.com/clamps
Clamp Meters
CLAMP METERS
35
Wireless Fluke Connect® Meters
Wirelessly relay measurements using Fluke Connect®
Eliminate data entry by wirelessly syncing measurements from your tool.
v3000 FC Wireless AC Voltage Meter (not shown)
Measure up to 1000 V true-rms AC
Use as a standalone meter or as part of the system
Logging function for recording and saving up to 65,000 readings
v3001 FC Wireless DC Voltage Meter
Measure up to 1000 V DC
Use as a standalone meter or as part of the system
Logging function for recording and saving up to 65,000 readings
t3000 FC Wireless K-type Temperature Meter
Use as a standalone meter (-200 °C to 1372 °C, 328 °F to 2501 °F) or as part of the system
Logging function for recording and saving up to 65,000 readings
ir3000 FC Connector
Supports 289 and 287 true-rms DMM; 189 DMM and 789 ProcessMeter
Fits over the IR port of your existing Fluke tools
Enables you to graph, save, and share readings with your team from
your smart phone
pc3000 FC Wireless PC Adapter
Collects up to 65,000 sets of time stamped min/max/avg readings
from FC remote modules
Display up to six simultaneous live readings via included Windows sw3000 FC Software
Fluke t3000 FC Wireless
K-type Temperature Meter
Fluke v3001 FC Wireless DC
Voltage Meter
Fluke ir3000 FC Connector
Fluke Connect Wireless PC
Adapter
The largest suite of
connected test tools
in the world
Ordering information
Models Included accessories
FLK-a3000 FC Wireless AC Current Clamp Meter Test leads, information pack, and alligator clips
FLK-a3001 FC Wireless iFlex® AC Current Meter iFlex current probe, information pack, and magnetic hanger
FLK-a3002 FC Wireless AC/DC Current Meter Magnetic hanger and information pack
FLK-a3003 FC Wireless 2000 A DC Current Clamp
Meter 2000 A DC Clamp, information pack, and magnetic hanger
FLK-a3004 FC Wireless 4-20 mA DC Current Meter 4-20 mA DC current probe, information pack, and hanging
strap
FLK-v3000 FC Wireless AC Voltage Meter Test leads, alligator clips, magnetic hanger, and information
pack
FLK-v3001 FC Wireless DC Voltage Meter Test leads, alligator clips, magnetic hanger, and information
pack
FLK-t3000 FC Wireless K-type Temperature Meter Temperature probe, magnetic hanger, and information pack
FLUKE-ir3000 FC Connector Compatible with: Fluke 789, 289, 287, 189
FLK-PC3000 Wireless PC Adapter
www.fluke.com/flukeconnecttools Wireless Tools
WIRELESS TOOLS
36
Fluke 8846A, 8845A and 8808A
Precision Bench Multimeters
Performs functions expected in multifunction digital multimeters
The Fluke 8846A/8845A 6.5 Digit Precision Multimeters measure volts, ohms and amps. Basic
V dc accuracy of up to 0.0024 %, 10 A current range, and a wide ohms range give you an
unbeatable combination of measurement capability.
Extend the meters utility even more with their graphical display modes, including Trendplot™
paperless recorder mode, statistics and histograms—features you won’t find on other multimeters
6.5 digit resolution
Up to 0.0024 % accuracy
Graphical analysis modes: TrendPlot, Histogram, and Statistics
Dual measurement inputs: front/rear
Wide measurement ranges
IEEE, LAN, RS-232 interfaces
USB memory device port (8846A)
TL2X4 wire measurement technique
Three-year warranty
Fluke 8808A 5.5 Digit Multimeter
The Fluke 8808A multimeter has a broad range of functions, measuring volts, ohms and
amps with a basic V dc accuracy of 0.015 %. The meter is easy to use and include innovative
functions to simplify routine testing and precision 4 wire resistance measurements.
5.5 digit resolution
Up to 0.015 % accuracy
Sensitive dc leakage current ranges
Front panel setup keys
TL2X4 wire measurement technique
Three-year warranty
Bench Multimeters www.uke.com/884X
Specifications
Fluke 8808A Fluke 8845A 8846A
Display dual dual, graphical
Resolution (No. of digits) 5.5 6.5
Measurements V ac, V dc, I dc, I ac, Ω,
Cont, Diode
V ac, V dc, I dc, I ac, Ω, Cont, Diode
Basic V dc accuracy
(% Reading + % Range)
0.015 + 0.003 0.0035 + 0.0005 0.0024 + 0.0005
Advanced measurements/
functions
2x4 wire ohms, freq,
i-Leakage
dedicated setup keys
2x4 wire ohms, freq,
period
2x4 wire ohms, freq,
period, capacitance,
temp (RTD)
Math Null, dBm, dB, Min, Max Null, dBm, dB, Min, Max, Ave, Std Deviation, MX+B
Analysis Limit Compare Limit Compare, TrendPlot, Histogram, Statistics
USB memory device port
Interfaces RS-232, USB via
optional adapter
RS-232, IEEE-488.2, LAN, USB via optional adapter
Safety rating CAT II 600 V CAT II 600 V
True
Histogram mode can reveal
stability or noise problems.
Make true 4-wire
measurements with
just two leads. Ordering information
Models Included accessories
FLUKE-8846A 6.5 Digit Precision Multimeter, 24 ppm
USB memory
Power cord, test lead set, programmers manual/users manual
on CD, FVF-BASIC, FlukeView Forms Software Basic Version
FLUKE-8845A 6.5 Digit Precision Multimeter, 35 ppm Power cord, test lead set, programmers manual/users manual
on CD, FVF-BASIC, FlukeView Forms Software Basic Version
FLUKE-8808A 5.5 Digit Multimeter Test leads, line cord, getting started guide, users manual
on CD
Built-in TrendPlot graphically
plots extent of drift and
intermittent events.
True
BENCH MULTIMETERS
37
www.fluke.com/distance Laser Distance Meters
Fluke 424D, 419D and 414D Laser Distance Meters
Measure farther, with greater accuracy, in more situations
The Fluke family of laser distance meters are essential tools in the tool bag. They provide,
instant and accurate measurements up to ± 1 mm with no scales to interpret or misread. Just
point, click, done. The 424D has an inclination sensor that helps with leveling, height tracking
and, measuring around obstacles. Find area and volume, easily add and subtract distances
and calculate height. Easily measure hard-to-access areas without climbing a ladder and
without the need for a helper.
Kits—buy more, save more
414D/62 MAX+ Kit 414D Laser
Distance Meter and 62MAX+ IR
Thermometer
Complies with EN 60825-1:2007 (Class II)
Ordering information
Models Included accessories
Fluke 424D Laser Distance Meter Two AAA batteries, users manual on CD, quick reference guide, vinyl carrying
pouch, and three-year warranty
Fluke 419D Laser Distance Meter Two AAA batteries, users manual on CD, quick reference guide, vinyl carrying
pouch, and three-year warranty
Fluke 414D Laser Distance Meter Two AAA batteries, users manual on CD, quick reference guide, vinyl carrying
pouch, and three-year warranty
Specifications
Fluke 424D Fluke 419D Fluke 414D
Maximum measurement
distance 100 m (330 ft) 80 m (260 ft) 50 m (165 ft)
Accuracy ± 1 mm (± 0.04 in) ± 1 mm (± 0.04 in) ± 2 mm (± 0.08 in)
Battery life (number of
measurements) 5000 5000 3000
Area measurement •••
Volume measurement •••
Pythagoras calculations Full Full 1+2
Plus and minus
calculations •••
Measurement storage 20 complete displays 20 complete displays 5 results
Min/Max Yes(Pyth)
Tripod mount
Corner angle measurement
Stake out
Inclination sensor
Display 4 line 3 line 2 line
Automated end-piece
correction
DISTANCE METERS
38 www.fluke.com/egt
Earth Ground Testers
Fluke 1625-2 and 1623-2 Geo Earth
Ground Testers
Simpler, faster testing
Grounding testers, like the Fluke 1623-2 and 1625-2, help maintain uptime and lower the risk
of electric shock to users while helping solve intermittent power quality problems. The Fluke
earth ground testers perform all four essential earth ground test methods that users demand:
3- and 4-pole Fall of Potential, earth resistance loop testing
4-pole soil resistivity testing
Selective earth ground testing using one clamp
Stakeless earth ground testing using two clamps
The 1623-2 and 1625-2 also make earth grounding tests faster and easier than previous
methods because of automatic data collection and storage and faster setup. Color coded wires
for easier identification and deploying of wire reels and stakes.
IP56 rated for outdoor use
USB data storage and transfer
Automatic Frequency Control (AFC)—identifies existing interference and chooses a
measurement frequency to minimize its effect, providing more accurate earth ground value
R* measurement—calculates earth ground impedance at 55 Hz to more accurately reflect the
earth ground resistance that a fault-to-earth ground would see
Adjustable limits —for quicker testing
These products are for unpowered installations measuring grounding connections.
Selection guide
1630 1621 1623-2 1625-2
2-Pole (ac) resistance measurement •••
3-Pole earth measurement •••
Measurement frequency—128 Hz
4-Pole earth ground and soil resistivity measurement
Selective testing
Stakeless testing (ground loop resistance)
Memory
USB port
Automatic Frequency Control (AFC) 94 Hz to 128 Hz
R* measurement
Adjustable limits
Ordering information
Models Included accessories
FLUKE-1625-2 Advanced GEO Earth Ground Tester Two test leads, USB cable, batteries, quick reference guide,
users manual
FLUKE-1623-2 Basic GEO Earth Ground Tester Two test leads, USB cable, batteries, quick reference guide,
users manual
FLUKE-1625-2 KIT Advanced GEO Earth Ground
Tester Kit Two test leads, USB cable, 2 clamps (1 source, 1 sensing),
carrying case, 4 earth ground stakes, 3 color coded cable
reels, batteries, quick reference guide, users manual
FLUKE-1623-2 KIT Basic GEO Earth Ground Tester Kit
Kits—buy more, save more Recommended accessories
Fluke 1625-2 Kit
ES-162P4-2 Stake/reel set for
4-pole measurement
EI-1625 Selective/
stakeless clamp set
for 1625-2
EI-162BN 320 mm
(12.6 in) Split Core
Transformer for use
with Fluke 1625-2
Clamp-on transformer
accessory for ground
loop measurements on
transmission pylons.
Faster setup, easier testing
and deployment of wire
reels and stakes.
EARTH GROUND TESTERS
39
Earth Ground Testers
www.fluke.com/egt
Fluke 1630 Earth Ground Clamp Meter
Safely measures ground loop resistance
The Fluke 1630 Earth Ground Clamp Meter is able to measure ground loop resistances—using
the stakeless testing method. This test technique eliminates the dangerous, and time consum-
ing activity, of disconnecting parallel grounds. You can also perform earth ground tests: inside
buildings, on power pylons or anywhere you don’t have access to soil.
With the stakeless testing method, no earth ground stakes are used at all. A known voltage is
induced by one half of the clamp and the current is measured by the other half. The tester auto-
matically determines the ground loop resistance at this grounding connection.
Quick and easy use—no earth ground stakes are necessary
Large, 35 mm (1.35 in) jaw opening
Measures ground resistance from 0.025 Ω to 1500 Ω
Measures ground leakage current from 0.2 mA to 30 A
High and low alarming
Automatic self calibration
Rugged carrying case and resistance check loop included
Two-year warranty
CAT III 300 V, CAT II 600
Fluke 1621 Basic Earth Ground Tester
Earth ground tester for resistance measurement
The Fluke 1621 Earth Ground Tester is a rugged, easy-to-use tester for three-pole ground
resistance measurements and two-pole ac resistance measurements.
Earth ground resistance is measured by installing earth ground test electrodes, and testing.
With a simple user interface and intuitive functionality, the large, clear LCD display provides
high visibility results in daylight or poor lighting conditions.
Three-pole earth resistance measurements
Two-pole AC resistance measurements
Large dual backlit display
Limit settings for automatic measurement evaluation
CAT II 600 V
Two-year warranty
Kits—buy more, save more Recommended accessories
Fluke 1621 Tester
Cable Reel 50 m
Ground/earth wire
(162.5 ft) for 1621
Cable Reel 25 m
Ground/earth wire
(81.25 ft) for 1621
ES-162P3 Stake/
reel set for 3-pole
measurements for
1621
Ordering information
Models Included accessories
FLUKE-1621 Basic Earth Ground Tester Two measuring leads with alligator clips, 2 m (6 ft), yellow protective
holster, 9 V alkaline battery (LR61), users manual, CD
Ordering information
Models Included accessories
FLUKE-1630 Earth Ground Clamp Meter Rugged carrying case with belt, resistance test loop, 9 V battery,
users manual
Take leakage current or
ground measurements on
grounding systems with
multiple parallel grounding
electrodes (transformers,
utility grounds, transmission
tower grounds, and
communication ground
systems).
EARTH GROUND TESTERS
40 Earth Ground Testers www.uke.com/electricaltesters
Fluke T5-1000
Specifications
T+PRO T+ T5-1000 T5-600
Measure ac/dc voltage Preset 12 V, 24 V, 48 V, 120 V, 208 V,
240 V, 277 V (Canada 347 V), 480 V, 600 V 1000 V 600 V
Measure ac current (avg) 100 A 100 A
Measure continuity < 25 Ω < 25 Ω
Measure resistance 9.99 k 1000 Ω 1000 Ω
DC polarity indicator
Detachable probe tips
w/optional tip styles
Digital display
Safety rating CAT IV 600 V/
CAT III 1000 V
CAT IV 600 V/
CAT III 1000 V
1000 V Overvoltage
CAT III
600 V Overvoltage
CAT III
Warranty Two-year Two-year Two-year Two-year
*Voltage levels will vary depending on country of intended use.
Fluke T5, T+PRO and T+ Electrical Testers
and VoltAlert
Fluke T+PRO and T+ Electrical Testers
Three forms of ac/dc voltage detection: Light, sound and vibration
Detects live voltage even when batteries are dead
Extra heavy-duty, replaceable test leads
Rotary field indicator for troubleshooting three-phase systems
Continuity beeper, LED flashlight and GFCI trip
Fluke T5-1000 and T5-600 Voltage, Continuity and
Current Testers
Excellent front-line troubleshooting and measurement tool
Available in 600 V and 1000 V models
OpenJaw current measurement
Rotary switch selects volts, amps and ohms functions
Heavy-duty test leads
Specifications
2AC 1AC-II 1LAC-II LVD2
Voltage range 90 V ac to 1000 V ac 90 V ac to 1000 V ac 20 V ac to 90 V ac 90 V ac to 600 V ac
Audible alert
Flashlight
On/Off Always on
Safety rating CAT IV 1000 V CAT IV 1000 V CAT IV 1000 V CAT IV 600 V
Fluke T+PRO
Fluke LVD2
Fluke 1AC-II Fluke 2AC Fluke VoltAlert Family
The next generation VoltAlert ac non-contact voltage testers from Fluke are easy to use.
Electricians, maintenance, service and safety personnel, and homeowners can quickly test for
energized circuits in the workplace or at home. Certified up to CAT IV 1000 V.
Ordering information
Models Included accessories
T+PRO and T+PRO CAN Electrical Tester Attached test probes, lead wrap, users manual
T+ and T+ CAN Electrical Tester Attached test probes, lead wrap, users manual
T5-1000 1000 V Voltage, Continuity and Current Tester Detachable probes and instruction sheet
T5-600 600 V Voltage, Continuity and Current Tester Detachable probes and instruction sheet
Ordering information
Models
2AC VoltAlert Voltage Detector
1AC-II VoltAlert Voltage Detector
1LAC-II VoltAlert Voltage Detector
LVD2 Volt Light
ELECTRICAL TESTERS
41
www.fluke.com/iaq Electrical Testers
Indoor Air Quality Tools
Tools to help you maintain good IAQ
Fluke 971 Temperature Humidity Meter
Temperature and humidity are two important factors in maintaining optimal comfort levels
and good indoor air quality. Quickly and conveniently take accurate humidity and temperature
readings with the Fluke 971. The Fluke 971 is invaluable for facility maintenance and utility
technicians, HVAC-service contractors, and specialists who assess indoor air quality (IAQ). The
Fluke 971 the perfect tool for monitoring problem areas. It is built to perform and made to last.
New and improved digital sensor for faster response times
Backlit dual display of humidity and temperature
Measures dew point and wet bulb temperatures
99 record storage capacity
Compact and lightweight at 188 g (6.6 oz)
Min/Max/Avg/Hold functions
Specifications
Functions Measurements
Temperature range -20 °C to 60 °C (-4 °F to 140 °F)
Relative humidity range 5 % to 95 %
Temperature update rate 500 ms
Temperature sensor type NTC
Response time (humidity) For 90 % of total range - 60 sec. with 1 m/s air movement
Humidity sensor Electronic capacitance polymer film sensor
Battery type 4 AAA alkaline batteries
Battery life 200 Hours
Safety approval Electromagnetic compatibility: Complies with EN 61326-1
Specifications
Functions Measurements
Flow rate 2.83 L/min (0.1 cfm)
Light source 775 nm to 795 nm, 90 mW class 3B laser
Count modes Raw counts, #/m3, #/ft3, #/liter in Cumulative or Differential mode
Counting efficiency 50 % @ 0.3 µm; 100 % for particles > 0.45 µm (per ISO 21501)
Zero count 1 count/5 minute (JIS B9921)
Concentration limits 10 % at 4,000,000 particles per ft3 (per ISO 21501)
Sample inlet Isokinetic probe
Operating environment 10 °C to 40 °C (50 °F to 104 °F)/< 95 % non-condensingrelative humidity
Warranty One-year
Fluke 985 Airborne Particle Counter
The Fluke 985 Particle Counter is ideal for troubleshooting and monitoring indoor air quality
issues and verifying HVAC filter performance in critical locations, and is the perfect tool for the
maintenance, HVAC, and IAQ professional.
Six channels and particle size range of 0.3 µm to 10.0 µm
Large 3.5 inch QVGA color display
10,000 record storage: Quick access to historical data
On-screen data presentation
Personalized setting and configurations
Download data to a PC using a USB memory stick, USB cable or Ethernet connection
USB/Ethernet charge cradle
Ordering information
Models Included accessories
FLUKE-985 Airborne
Particle Counter
Certificate of Calibration (NIST traceable), cradle for charging and convenient USB and
Ethernet communications, ethernet cable, USB cable, power supply, zero count inlet filter,
filter adapter, sample inlet protective cap, hard case, manual
FLUKE-971 Temperature
Humidity Meter Four AAA alkaline batteries, users manual
Monitor air humidity levels
throughout your facility with
the Fluke 971.
Find how-to videos, application notes and other resources on the indoor air quality product pages on
www.fluke.com
INDOOR AIR QUALITY TOOLS
42 www.fluke.com/iaq
Indoor Air Quality Tools
Fluke RLD2 UV Refrigerant Leak Detector Flashlight
Flashlight that uncovers refrigerant leaks instantly. Laser pointer to find exact leak location.
CO-220 Carbon Monoxide Meter
Check CO levels around furnaces and boilers. Tracks increasing frequency as CO levels rise.
CO-205 Aspirator Kit
A flue gas sampling accessory kit.
Ordering information
Models Included accessories
FLUKE-975V AirMeter with Velocity Calibration cap, air velocity probe (Fluke 975V only), FlukeView® Forms
software, power adapter, international power plugs, hard carrying case, three
AA alkaline batteries, users manual with safety information
FLUKE-975 AirMeter
FLUKE-922 Airflow Meter Two rubber hoses, soft carrying case, four AA alkaline batteries 1.5 V,
users manual
FLUKE-922/Kit Airflow Meter Kit 12 inch pitot tube, two rubber hoses, magnetic hanging strap, four AA alkaline
batteries, users manual, hard carrying case
FLUKE-RLD2 Refrigerant Leak Detector Flashlight
FLUKE-CO-220 Carbon Monoxide Meter
FLUKE-CO-205 Aspirator Kit
Specifications
Range Accuracy
Air pressure ± 4000 Pascals/± 16 in H2O/± 400 mm H2O/
± 40 mbar/± 0.6 PSI
± 1 % + 1 Pascal/± 1 % + 0.01 in H2O/
± 1 % + 0.1 mm H2O/± 1 % + 0.01 mbar/
± 1 % + 0.0001 PSI
Air velocity 250 fpm to 16,000 fpm (1 to 80 m/s) ± 2.5 % of reading at 2000 fpm (10.00 m/s)
Air flow
(volume)
0 to 99,999 cfm; 0 to 99,999 m 3/hr; 0 to
99,999 l/s
Accuracy is a function of velocity and duct
size
Temperature 0 °C to 50 °C (32 °F to 122 °F) 0.1 °C (0.1 °F)
Data storage 99 readings
Fluke 975 AirMeter
Simple, all-in-one air diagnostics
The Fluke 975 AirMeter combines five powerful air quality tools into one.
Simultaneously measures, logs and displays temperature, humidity, CO2 and CO
% of outside air calculation, one-touch air flow and velocity with available probe (975V)
Dew point and wet bulb temperature
CO2 and CO field calibration feature
Min/Max/Avg on all measured and calculated readings, audible and visual threshold alarms
Discrete or continuous data logging capacity, downloadable to PC via USB interface
Automatically compensates for barometric pressure changes
Two-year warranty
Fluke 922 Airflow Meter/Micromanometer
The Fluke 922 makes your job easier by combining differential pressure, airflow and velocity
into a single, rugged meter.
Measures differential and static pressure, air velocity and flow readings
User-defined duct shape and size for maximum airflow accuracy
Min/Max/Avg/Hold functions
Instrument CarePlan
INDOOR AIR QUALITY TOOLS
Specifications
Range Display resolution Accuracy
Temperature -20 °C to 50 °C
(-5 °F to 122 °F) 0.1 °C (0.1 °F) ± 0.9 °C/± 1.62 °F from 40 °C to 60 °C ± 0.5 °C/± 1.00 °F
from 5 °C to 40 °C ± 1.1 °C/± 1.98 °F from -20 °C to 5 °C
Relative
humidity
10 % to 90 % RH
non-condensing 1 % ± 2 % RH (10 % RH to 90 % RH)
Air velocity
50.0 fpm to
3000 fpm 0.25 m/s
to 15 m/s
1 fpm (0.005 m/s) ± 4 % or 4 fpm* ± 4 % or 0.02 m/s* whichever is greater
* Accuracy specification only valid for velocity readings above 0.25 m/s
CO2
0 ppm to
5000 ppm 1 ppm Warm up time 1 min (5 minutes for full specification)
2.75 % + 75 ppm
CO 0 ppm to 500 ppm 1 ppm ± 5 % or ± 3 ppm, whichever is greater, @ 20 °C and 50 % RH
43
Indoor Air Quality Tools
www.fluke.com/flt
Fluke 1000FLT Fluorescent Light Tester
Take the trial and error out of fluorescent light testing
Save time and reduce costs by using the only tester that performs all five essential lighting
tests in less than 30 seconds. The Fluke 1000FLT fluorescent light tester makes your job easier
by quickly pinpointing problems and verifying operation of fluorescent lights and fixtures.
It is easy to use and can survive on-the-job handling, including a two meter drop. Like all
Fluke products, the 1000FLT is built to last, easy to maintain and is backed by a three-year
warranty. Companies have made significant investments in fluorescent lighting; if your job
requires keeping large numbers of these fluorescent lights shining, the Fluke 1000FLT is an
indispensable tool.
Lamp test: Test bulb without removing from fixture
Ballast test: Easily determine if ballast is working
Non-contact voltage: Quickly check for voltage presence
Pin continuity test: Tests if filaments have continuity
Ballast-type test: Determine if ballast is electronic or magnetic without taking fixture
apart—identify energy wasting ballasts
Specifications
Functions Measurements
Lamp test max output 3000 V peak-to-peak
Ballast test 20 kHz
Ballast type discriminator ≤3 m (10 ft) distance
Pin continuity test < 1 kΩ
NCV (VoltAlert)
85 V ac to 277 V ac
45 Hz to 67 Hz
≤ 10 cm (4 in) distance
Operating temperature -10 °C to +50 °C (14 °F to +122 °F)
Storage temperature Storage -40 °C to +60 °C (-40 °F to +140 °F)
Safety rating IEC 61010-1, pollution degree 2
Warranty Three-year
Ordering information
Models Included accessories
FLUKE-1000FLT Fluorescent Light Tester Quick reference guide, 4 AA alkaline batteries, holster
Easily determine if ballast
is working.
Quickly check for voltage
presence without touching
a live conductor.
FLUORESCENT LIGHT TESTER
44 www.fluke.com/insulationtesters
Insulation Resistance Testers
Fluke 1587 FC/1577 Insulation Multimeters
The High-Performance 2-in-1 Insulation DMM
The Fluke 1587 FC and 1577 Insulation Multimeters combine a digital insulation tester with a
full-featured, true-rms digital multi meter in a single compact, handheld unit, which provides
maximum versatility for both troubleshooting and preventive maintenance.
The Fluke 1587 FC Insulation Multimeter adds four powerful new diagnostic functions through
the Fluke Connect® Measurements app:
PI/DAR timed ratio tests with TrendIt™ graphs identifies moisture and contaminated insula-
tion problems faster
Memory storage through Fluke Connect eliminates writing down results, reduces errors and
saves data for historical tracking over time
Temperature Compensation through app for establishing accu rate baselines and relevant
historical comparisons
Historical tracking and trending of assets identifies degradation over time, allows real-time
decisions to be made in the field with Fluke Connect® Assets (sold separately)
True
Instrument CarePlan
Ordering information
Models Included accessories
FLUKE-1587 FC Insulation Multimeter Remote probe, test leads, alligator clips, K-type
thermocouple, hard case, users documentation
FLUKE-1577 Insulation Multimeter Remote probe, test leads, alligator clips, hard case,
users documentation
Kits—buy more, save more Recommended accessories
Fluke 1587 KIT/62MAX+ FC
Advanced Electrical
Troubleshooting Kit
Fluke 1587/MDT FC
Advanced Motor and Drive
Troubleshooting Kit
TLK289 Industrial Master
Test Lead Set
i400 AC Current
Clamp
Specifications
1587 FC 1577
PI/DAR timed ratio measurements with TrendIt™ graphs
through Fluke Connect Measurements app
Memory storage through Fluke Connect Measurements app
Temperature Compensation through Fluke Connect
Measurements app
Insulation test voltages 50 V, 100 V, 250 V, 500 V, 1000 V
Insulation test voltages 500 V, 1000 V
Insulation resistance 0.01 MΩ to 2.0 GΩ 0.1 MΩ to 600 MΩ
Auto-discharge of capacitive voltage
Insulation test smoothing reading
Frequency
Capacitance
Diode test
Temperature
Min/Max
VFD low-pass filter for accurate motor drive measurements
AC/DC voltage
DC millivolts
AC/DC milliamps
Resistance 0.1 Ω to 50 MΩ 0.1 Ω to 50 MΩ
Continuity
Auto power off
Warranty (years) 3 3
INSULATION TESTERS
Troubleshooting efficiency
and maximum versatility
while testing motors and
VSDs accurately with
Low-Pass filter.
45
Insulation Resistance Testers
www.fluke.com/insulationtesters
Fluke 1507 and 1503 Insulation
Resistance Testers
The quality, durability, and convenience you need
These lightweight, affordable insulation testers are perfect for troubleshooting,
commissioning and preventive maintenance applications.
Automatic calculation of polarization index and dialectric absorption ratio (1507 only)
Multiple test voltages: 50 V, 100 V, 250 V, 500 V, 1000 V (1507 only)
Remote test probe for rapid testing
Insulation test range 0.01 MΩ to 10 GΩ (1507), 0.1 MΩ to 2 GΩ (1503)
Compare (Pass/Fail) function for repetitive tests (1507 only)
Live circuit detection prevents insulation test if voltage > 30 V is detected
Auto-discharge of capacitive voltage
AC/DC voltage: 0.1 V to 600 V
Lo ohms/Earth-bond continuity (200 mA) for checking connections and motor windings
Resistance: 0.01 Ω to 20.00 kΩ
Instrument CarePlan
Ordering information
Models Included accessories
FLUKE-1507 Insulation Tester Remote probe, silicone test leads, test probes, large
alligator clips, holster, users manual
FLUKE-1503 Insulation Tester Remote probe, silicone test leads, test probes, large
alligator clips, holster, users manual
Recommended accessories
TLK289 Industrial Master
Test Lead Set
TL27 Heavy Duty Test
Lead Set
C116 Soft Carrying
Case C101 Hard Case
Magnetic Meter Hanger
frees up both hands
to focus on making
measurements safely.
Check connections and
motor windings with
Lo ohms/earth-bond
continuity test.
Specifications
1507 1503
Insulation test voltages 50 V, 100 V, 250 V, 500 V, 1000 V
Insulation test voltages 500 V, 1000 V
Insulation resistance 0.01 MΩ to 10 GΩ 0.1 MΩ to
2 GΩ
Auto-discharge of capacitive voltage
Continuity function 200 mA acc. EN 61557-4
Resistance 0.1 Ω to 20.00 kΩ 0.1 Ω to 20.00 kΩ
Auto power off
Warranty (years) 1 1
INSULATION TESTERS
46
1555 and 1550C Insulation Resistance Testers
Powerful troubleshooting and predictive maintenance tools
The Fluke 1555 and Fluke 1550C Insulation Resistance Testers offer digital insulation testing
up to 10 kV, making them ideal for testing a wide range of high voltage equipment including
switchgear, motors, generators and cables.
Test voltages up to 5 kV (1550C) and 10 kV (1555) provide solutions for all applications
Warning function alerts the user that line voltage is present and gives a voltage reading up
to 600 V ac or dc for increased user safety
Measurements can be stored in up to 99 memory locations, and each location is assigned a
unique, user-defined label for easy recall
Automatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no
additional setup
Guard system eliminates the effect of surface leakage current on high-resistance
measurements
Capacitance and leakage current measurement
Ramp function for breakdown testing
Ordering information
Models Included accessories
FLUKE-1550C 5 kV Insulation Tester Test leads with alligator clips, infrared adapter with
interface cable, FlukeView Forms software, ac power cord,
soft carrying case, quick reference guide, users manual
FLUKE-1555 10 kV Insulation Tester
FLUKE-1550C KIT Test leads with ruggedized alligator clips, infrared
adapter with interface cable, FlukeView Forms software,
AC power cord, hard carrying case, quick reference guide,
users manual, NIST traceable certificate
FLUKE-1555 KIT
Specifications
Test voltage (dc) Range Accuracy (± reading)
250 V
< 250 kΩ
250 kΩ to 5 GΩ
5 GΩ to 50 GΩ
> 50 GΩ
unspecified
5 %
20 %
unspecified
500 V
< 500 kΩ
500 KΩ to 10 GΩ
10 GΩ to 100 GΩ
> 100 GΩ
unspecified
5 %
20 %
unspecified
1000 V
< 1 MΩ
1 MΩ to 20 GΩ
20 GΩ to 200 GΩ
> 200 GΩ
unspecified
5 %
20 %
unspecified
2500 V
< 2.5 MΩ
2.5 MΩ to 50 GΩ
50 GΩ to 500 GΩ
> 500 GΩ
unspecified
5 %
20 %
unspecified
5000 V
< 5 MΩ
5 MΩ to 100 GΩ
100 GΩ to 1 TΩ
> 1 TΩ
unspecified
5 %
20 %
unspecified
10000 V (1555 only)
< 10 MΩ
10 MΩ to 200 GΩ
200 GΩ to 2 TΩ
> 2 TΩ
unspecified
5 %
20 %
unspecified
Functions
Leakage current 1 nA to 2 mA ± (20 % + 2 nA)
Capacitance measurement 0.01 uF to 20.00 µF ± (15 % rdg + 0.03 µF)
Live circuit indicator 30 V to 1100 V ac/dc, 50/60 Hz ±(15 % + 2 V)
Selection guide
1555 1550C
Insulation test voltages: User selectable 250 V to 5000 V
Insulation test voltages: User selectable 250 V to 10,000 V
Insulation resistance 2 TΩ 1 TΩ
Auto-discharge of capacitive voltage
Warranty (years) 3 3
Instrument CarePlan
Flexibility for testing wide
range of high voltage
applications.
www.fluke.com/insulationtesters
Insulation Resistance Testers
INSULATION TESTERS
47
Power Quality Analyzers
www.fluke.com/pq
Basic measurements Application use
Single-Phase Three-Phase
VR1710 345 43B 1730 1736/38 1740 430-II 1750 1760
Energy studies
Measure V, I, kW, Cos/
DPF, kWhr Get detailed power and
energy consumption
profiles during energy
audits and pinpoint
savings opportunities
Measure MIN/MAX
and AVG values
10 day logging
Waste energy
monetization
Basic harmonics study
THD measurement
(V & I)
Discover the source
of distortion in your
installation, so that you
can filter those loads or
move them to separate
circuits
Harmonics 1 to 25 for
V & I
(V only)
Advanced harmonics study
Full harmonic
spectrum
If distorting loads are
causing problems in
your installation, you
need comprehensive
data to identify the
source and create a
solution
Power harmonics
Basic industrial PQ troubleshooting
Oscilloscope function When troubleshooting
in the field, graphical
data enables you to
trace the source of the
problem at hand
Voltage dips and
swells
Advanced industrial PQ troubleshooting
Comprehensive
logging capability
Complex installations
often require a deeper
dive into measurement
data. Multiple loads may
be interacting randomly
to cause a single
problem
Transient capture
Flicker
Motor analysis
Speed Perform dynamic motor
analysis by plotting of
motor de-rating
factor against load
according to
NEMA/IEC guidelines
on direct on-line
electric motors
Torque
Mechanical power
Efficiency
Features
Inrush
Flicker
Transients
Mains signaling
Power wave
Event waveform capture
400 Hz
Power inverter efficiency
Power quality and energy tools selection guide
Find how-to videos, application notes and other resources on the power quality and ower and energy loggers product pages on www.fluke.com
POWER QUALITY AND ENERGY TOOLS
48 www.fluke.com/pq
Power Quality Analyzers
Fluke 1730 Three-Phase Electrical Energy Logger
Find sources of energy waste
The Fluke 1730 Three-Phase Electrical Energy Logger introduces a new simplicity to
discovering sources of electrical energy waste. Profiling energy usage across your facility
helps you identify opportunities for energy savings and provides you with the easy-to-
understand data. The Fluke 1730 Energy Logger can be used for conducting energy surveys
that require both a voltage and current connection. Load studies that require a current
connection only for evaluating electrical demand capacity can also be performed.
Quickly understand specific points of energy loss, reduce energy bills more easily than ever
Optimized layout with specialized touch screen makes navigation easy—even with gloves on
Advanced auto-correct feature eliminates costly errors due to improper connections
Power directly from the measured voltage line (up to 500 V) or with conventional ac power cord
Fluke 430-II Series Three-Phase
Power Quality and Motor Analyzers
Locate, predict, prevent power quality problems
The Fluke 434-II, 435-II, 437-II and 438-II help troubleshoot power quality problems in three-
and single-phase power distribution systems. The Fluke patented energy loss algorithm, Unified
Power Measurement, measures, quantifies and monetizes energy losses due to harmonics and
unbalance issues, allowing the user to pinpoint the origin of energy waste within a system.
Capture fast rms data in real time with PowerWave data capture; show single cycle rms
value to characterize electrical system dynamics (generator start-ups, UPS switching etc.)
Measure key parameters on direct-on-line motors including torque, RPM, mechanical power
and motor efficiency (438-II, or with 430-II/MA upgrade option)
CAT IV 600 V/CAT III 1000 V rated for use at the service entrance
Automatic transient mode; capture 200 kHz waveform data on all phases simultaneously up
to 6 kV for 435-II and 437-II
Conduct tests according to the stringent international IEC 61000-4-30 Class-A standard
intervals for 435-II and 437-II
With included four iFlex flexible current probes, measure all three phases and neutral
Download data wirelessly with the Fluke Connect® SD Card (not included with the INTL)
Three-year warranty
Instrument CarePlan
Ordering information
Models Included accessories
FLUKE-434-II Three-Phase Energy Analyzer
Four thin flexible current probes, five test leads and clips, battery
charger, Power Log software, USB cable, color localization set, soft
carrying case, 8GB WiFi SD memory card, users manual on CD
FLUKE-435-II Three-Phase Power Quality
and Energy Analyzer
Fluke-438-II Three-Phase Power Quality
and Motor Analyzer
FLUKE-437-II 400 Hz Three-Phase Power
Quality and Energy Analyzer
Four thin flexible current probes, five test leads and clips, battery
charger, Power Log software, USB cable, color localization set, hard
carrying case with wheels, 8GB WiFi SD memory card, users manual
on CD
Fluke-430-II/MA 430-II Motor Analyzer
Upgrade Kit Firmware license code
Ordering information
Models Included accessories
1730/BASIC Three-Phase Electrical Energy Logger
(excludes current probes)
Power supply, voltage test lead, dolphin clip,
i1730-flex 1500 iFlex Flexible Current Probes,
color-coded wire clips, power cord, test lead set
with stackable plugs, dc power cable(s), USB cable
A, mini USB, soft storage bag, input connector
decal, information packet. Software included
Software included (FEA, Fluke Energy Analyze)
1730/US Portable Energy Logger US version
1730/EU Portable Energy Logger EU version
1730/INTL Portable Energy Logger ITNL version
FLUKE-1735 Three-Phase Power Logger
Four flexible current probes (15 A/150 A/3000 A),
Power Log software, voltage leads and clips, color
localization set, PC interface cable, international ac
adapter (115 V/230 V, 50 Hz/60 Hz), soft carrying
case, users manual, multi-language manual on CD
POWER QUALITY AND ENERGY TOOLS
49
Power Quality Analyzers
www.fluke.com/energylogger
Specifications
Accuracy
Parameter Range Resolution Intrinsic accuracy at reference conditions
(% of reading + % of full scale)
Voltage 1000 V 0.1 V ± (0.2 % + 0.01 %)
Current:
Direct input
i17xx-flex 1500
12
150 A 0.1 A ± (1 % + 0.02 %)
1500 A 1 A ± (1 % + 0.02 %)
i17xx-flex 3000
24”
300 A 1 A ± (1 % + 0.03 %)
3000 A 10 A ± (1 % + 0.03 %)
i17xx-flex 6000
36”
600 A 1 A ± (1.5 % + 0.03 %)
6000 A 10 A ± (1.5 % + 0.03 %)
i40s-EL clamp 4 A 1 mA ± (0.7 % + 0.02 %)
40 A 10 mA ± (0.7 % + 0.02 %)
Frequency 42.5 Hz to 69 Hz 0.01 Hz ± (0.1 %)
Aux input ± 10 V dc 0.1 mV ± (0.2 % + 0.02 %)
Fluke 1736 and 1738 Three-Phase
Power Loggers
More visibility, reduced uncertainty and better power quality and energy
consumption decisions
The Fluke 1736 and 1738 Three-Phase Power Loggers built with Fluke Connect® mobile
app and desktop software compatibility give you the data you need to make critical
power quality and energy decisions in real-time. The ideal test tools for conducting
energy studies and basic power quality logging, the 1736 and 1738 automatically
capture and log over 500 power quality parameters so you have more visibility into the
data you need to optimize system reliability and savings.
Measure all three phases and neutral with included four flexible current probes.
Comprehensive logging: More than 20 separate logging sessions can be stored on the
instruments. In fact, all measured values are automatically logged so you never loose
measurement trends.
Capture dips, swells, and inrush currents: includes event waveform (1738 only)
snapshot and high resolution RMS profile, along with date, timestamp and severity to
help pinpoint potential root causes of power quality issues.
Optimized user interface: Capture the right data every time with quick, guided,
graphical setup and reduce uncertainty about your connections with the intelligent
verification function.
Fluke Connect® Compatible: View data locally on the instrument, via Fluke Connect
mobile app and desktop software or through your facilities’ WiFi infrastructure
1Range = 1000 V x Irange
Instrument CarePlan
POWER QUALITY AND ENERGY TOOLS
Ordering information
Models Included accessories
FLUKE-1736 Three-Phase Power Logger
Instrument, power supply, voltage test leads,
alligator clips (4x), 12 in 1,500 A flexible current
probe (4x), soft case, Energy Analyze Plus
software, WiFi adapter**, line cords, color coding
set and documentation on USB flash drive
FLUKE-1738 Three-Phase Power Logger
Instrument, power supply, voltage test leads,
alligator clips (4x), 12 in 1,500 A flexible current
probe (4x), soft case, Energy Analyze Plus
software, magnetic hanging strap, magnetic
voltage probes (4x), WiFi/BLE adapter**, line cords,
color coding set and documentation on USB flash
drive
FLUKE-1738/Upgrade
Magnetic hanging strap, magnetic voltage probes
(4x), WiFi/BLE adapter, Firmware license: PQ
Health, Wave form Event Capture
**Not all models are available in all countries. Check with your local Fluke representative.
50
Fluke 345 Power Quality Clamp Meter
Troubleshoot modern electrical loads
The Fluke 345 is more than a power meter. Combining the functions of a clamp meter,
oscilloscope, data logger and digital power meter into one handy device. The Fluke 345 is
ideal for working with variable frequency motor drives, high efficiency lighting and other
loads using switching electronics.
Clamp-on measurement of ac current up to 1400 A rms and dc current up to 2000 A without
breaking the circuit
CAT IV 600 V power analyzer is rated for use at the service entrance
Clamp meter performs even in noisy environments with distorted waveforms present on
electronic loads with low-pass filter
Identify intermittent faults by logging any power quality parameter for minutes, or over a
month, including harmonics
Analyze, log and troubleshoot harmonics digitally or graphically
Capture and analyze inrush current and nuisance tripping from 3 seconds to 300 seconds
View graphs and generate reports using power analyzer with included Power Log software
Fluke 43B Power Quality Analyzer
Measurements to maintain power systems
The Fluke 43B Power Quality Analyzer troubleshoots power problems and diagnoses
equipment failures. The 43B has 20 storage locations and can store data as well as screens.
Voltage, current and power harmonics up to 51st, THD
View voltage and current waveforms with the oscilloscope function
Capture up to 40 voltage transients and waveform events
Cursors give time and date of sags and swells for detailed event capture
Analysis and reporting with FlukeView® software, supplied with USB connection lead
Three-year warranty for analyzer, one-year warranty for accessories
Fluke VR1710 Power Quality Recorder
Fast and easy recording of voltage trends, dropouts and power quality to easily pinpoint the
root cause of single phase voltage problems
Min, Max, and Average RMS values (1/4 cycle) with time stamp, transient display (>100 μs)
with time stamp
Identify problems with power quality or equipment related Flicker recording to
EN 61000-4-15, individual harmonic and THD values with trends
Includes PowerLog software for quick download, analysis and automatic reporting
Generate power quality reports automatically with pre-set templates
Ordering information
Models Included accessories
FLUKE-345 Clamp-On Power Meter
Test leads, alligator clips, test probes, Power Log software, USB cable,
international ac adapter/battery eliminator, soft carrying case, users
manual, multi-language manual on CD
FLUKE-43B Power Quality Analyzer
Voltage and current probes, FlukeView® software, power quality
instructional CD, USB interface cable, line voltage adapter/battery charger,
hard case, users manual
FLUKE-VR1710 Voltage Quality Recorder USB cable, Power Log software CD, universal power cord adapters
www.fluke.com/pq
Power Quality Analyzers
POWER QUALITY AND ENERGY TOOLS
51
Specifications
1743/1744 1745 1750
Measures common power parameters:
V, A, W, VA, VAR, PF, energy, flicker,
voltage events, and THD
•••
Measures voltage and current
harmonics to the 50th, unbalance,
and mains signaling
•••
Transient capture
PDA support
UPS ride through 3s > 5 hours 5 min per interruption,
60 min total
Dimensions
170 mm x 125 mm x
55 mm (6.9 in x 5.1 in
x 2.2 in)
282 mm x 216 mm x
74 mm (11.5 in x 8.8 in
x 3 in)
215 mm x 310 mm x
35 mm (8.5 in x 12.2 in
x 3.5 in)
Weight (approx.) 0.9 kg (2 lb) 1.4 kg (3 lb) 6.3 kg (14 lb)
Fluke 1745
Fluke 1744/1743
In the U.S., these power quality recorders are sold exclusively through power quality representatives. To request a
demonstration, or to order, call 1-888-257-9897 or email questions to fpqsupport@fluke.com.
Fluke Norma 4000
Fluke Norma 5000
Fluke Norma 4000 and 5000 Precision Power
Analyzers
For field and laboratory testing
Fluke Norma 4000 and 5000 Precision Power Analyzers offer easy and straight-forward
operation with unmatched price performance. Features include: 1 to 6 power phases, 144 mm
(5.7 in) color display, harmonic analysis, scope mode, vector diagram display, recorder
function, Fluke NormaView PC software and 4MB RAM data memory.
A variety of standard configurations allows users to choose the exact functionality required
for their unique application
Inputs are galvanically isolated to avoid short circuits in all applications, and simultaneous
parallel acquisition of all phases allows for accurate viewing of dynamic events dc to
3 MHz/10 MHz bandwidth for reliable measurement precision
Voltage, current and power harmonics FFT analysis to the 40th harmonic, vector diagram,
and Digital Oscilloscope (DSO) mode included in the base unit
PI1 process interface to measure torque and speed with external sensors, plus four analog
outputs for easy use on motor and drive applications
Data download, analysis and report writing with supplied Fluke NormaView PC software
Fluke 1740 Series Three-Phase PQ Loggers
Instruments to troubleshoot and analyze power distribution
The Fluke 1740 Series Three-Phase Power Quality Loggers include PQ Log software to quickly
assesses the quality of power at the service entrance, substation, or at the load, according to
the latest EN50160 standard.
Setup in minutes with automatic current probe detection and powering
Compact, fully-insulated housing and accessories fit easily in tight spaces, next to live
power
Included PQ Log software analyzes trends, creates statistical summaries, and generates
detailed graphs and tables
IEC61000-4-30 Class-A compliant voltage accuracy (0.1 %)
Ordering information
Models Included accessories
Norma 4000 High Precision Power Analyzer Power supply cable, NormaView PC software, test certificate,
calibration values, users manual
Norma 5000 High Precision Power Analyzer
FLUKE-1745 Power Quality Logger – Memobox Four flexible probes 15/150/1500/3000 A with 2 m cable, PQ Log
software, RS-232 interface cable and USB adapter, four dolphin
clips, test leads for voltages and power supply, color localization
kit, carrying bag, test certificate with measurement values, users
manual, multi-language manual CD
FLUKE-1744 Power Quality Logger – Memobox
FLUKE-1743 Power Quality Logger – Memobox
Power Quality Analyzers
www.fluke.com/pq
POWER QUALITY AND ENERGY TOOLS
52
In the U.S., these power quality recorders are sold exclusively through power quality representatives. To request a
demonstration, or to order, call 1-888-257-9897 or email questions to fpqsupport@fluke.com.
Fluke 1750 Three-Phase Power Recorder
Never miss capturing a disturbance
The Fluke 1750 Power Recorder and the Fluke Power Analyze software allows you to easily
record three-phase power quality and monitor for power quality disturbances. These power
meters automatically record every power quality parameter and event, on every cycleall
the time.
All measurements comply with IEC61000-4-30 standards for correct evaluation of all mea-
sured values including voltage, current, power, harmonics, flicker etc.
PDA wireless “front panel interface” provides a window into what the instrument is record-
ing, enabling quick and reliable configuration even in awkward test locations
Cross-channel and current triggering capture every measurement, on every channel,
every time
With intuitive PC software, easily analyze data and generate reports. Automated EN50160
reporting and compliance
Voltage and current measurements on three phases, neutral and ground
Fluke 1760 Three-Phase Power Quality Recorder
Captures the most comprehensive details
The Fluke 1760 Three-Phase Power Quality Recorder is fully compliant to IEC 61000-4-30
Class-A, for advanced power quality analysis and consistent compliance testing. Designed
for analysis of utility and industrial power distribution systems, in medium- and low-
voltage networks, this power quality monitor provides the flexibility to customize thresholds,
algorithms, and measurement selections.
Use GPS time synchronization to correlate data with events or datasets from other
instruments with precision
Using flexible and fully configurable thresholds and scale factors, pinpoint specific issues by
defining the detailed criteria for detection and recording of disturbances
10 MHz, 6000 Vpk waveform capture for a detailed picture of even the shortest event
2GB data memory enables detailed, simultaneous recording of numerous power parameters
for long periods of time
Comprehensive software provides trend diagrams for root cause analysis, statistical
summaries, report writing and real-time data monitoring in the online mode
Quick setup with automatic sensor detection; sensors are instrument powered, eliminating
the need for batteries
Ordering information
Models Included accessories
FLUKE-1750 Three-Phase Power Recorder Kit Acquisition unit, PDA and charger, power plug adapters, 4 x
400 A 3140-PR current probes (1750 only), 4 x 1000 A 3210-
PR-TF iFlex current probes (1750-TF only), five test leads and
clips, SD memory card, Fluke Power View and Fluke Power
Analyze software, power cord with international plug set,
ethernet cable, color localization set, users manual and CD
FLUKE-1750-B Three-Phase Power Recorder Basic Kit
FLUKE 1750-TF Three-Phase Power Recorder Kit
FLUKE-1760 Three-Phase Power Recorder Acquisition unit, voltage and current probes (1760, 1760TR),
GPS time sync receiver (1760TR, 1760TR Basic) Fluke PQ
Analyze software, power cord with international plug set,
ethernet cable, color localization set, users manual and CD
FLUKE-1760 Basic Three-Phase Power Recorder
FLUKE-1760TR Three-Phase Power Recorder
FLUKE-1760TR Basic Three-Phase Power Recorder
Specifications
1760TR 1760 1760TR
BASIC
1760
BASIC
Online mode (oscilloscope, transients and events) ••••
Fast transient analysis up to 10 MHz
Four 600 V voltage probes
Four dual-range flexible current probes (1000 A/200 A ac)
GPS time sync receiver
www.fluke.com/pq
Power Quality Analyzers
POWER QUALITY AND ENERGY TOOLS
53
BATTERY ANALYZERS
Fluke BT500 Series Battery Analyzers
Reduced testing complexity, a simplified workflow and an intuitive user
interface provide a new level of ease-of-use in battery testing
The new Fluke BT500 Series Battery Analyzer is ideal test tool for maintenance, trouble-
shooting and performance testing of individual stationary batteries and battery banks used
in critical battery back-up applications. Fluke BT500 Series Battery Analyzers cover a broad
range of battery test functions ranging from dc voltage and resistance tests to full condition
testing using an automated string function testing and the test probe integrated infrared tem-
perature measurement system. BT500 Series Battery Analyzers are designed for measurements
on stationary batteries of all types.
Key measurements: Battery resistance, dc and ac voltage, dc and ac current, ripple voltage,
frequency and battery temperature
Sequence measurement mode: Automatic or manual sequence testing of battery strings
with automatic measurement storage including voltage, resistance and temperature (with
BTL21 intelligent test probe)
Comprehensive logging: All measured values are automatically captured during testing and
can be reviewed on the instrument before downloading for on the-go analysis
Optimized user interface: Quick, guided setup ensures the right data is captured every
time, and the combined visual and audio feedback cues reduce the risk of measurement
confusion
Safety CAT III 600 V
Specifications
Functions Range Resolution Accuracy BT510 BT520 BT521
Battery resistance1
3 mΩ 0.001 mΩ 1 % + 8
30 mΩ 0.01 mΩ 0.8 % + 6
300 mΩ 0.1 mΩ 0.8 % + 6
3000 1 mΩ 0.8 % + 6
V dc
6 V 0.001 V 0.09 % + 5
60 V 0.01 V 0.09 % + 5
600 V 0.1 V 0.09 % + 5
1000 V 1 V 0.09 % + 5
V ac (45 Hz to 500 Hz with 800 Hz filter) 600 V 0.1 V 2 % + 10
Frequency (displayed with V ac and A ac)2500 Hz 0.1 Hz 0.5 % + 8
AC voltage ripple (20 KHz Max) 600 mV 0.1 mV 3 % + 20
6000 mV 1 mV 3 % + 10
A dc/A ac (with accessory Fluke i410) 400 A 1 A 3.5 % + 2
Temperature 0 °C to 60 °C 1 °C 2 °C (4 °F)
Meter mode 999 records for each measurement position with time stamp
Sequence mode Up to 100 profiles and 100 profile templates (Each profile stores up to
450 batteries) with time stamp
1The measurement is based on AC injection method. The injected sourcesignal is < 100 mA, 1 kHz.
2Trigger level V ac: 10 mV, A ac: 10 A.
Ordering information
Models Included accessories
FLUKE-BT521 Advanced Battery Analyzer
4-wire test pin (set), test lead (set), test leads with adapter, test probe set
with extender and temperature sensor, ac/dc current clamp, lithium-ion
battery, ac charger, mini-USB cable, shoulder strap, belt strap, magnetic
hanging strap, software, soft carrying case, spare fuses (2), battery tags,
and zero ohm calibration resistor
FLUKE-BT520 Battery Analyzer
4-wire test pin (set), test lead (set), test leads with adapter, test probe set
with extender (no temperature sensor), lithium-ion battery, ac charger,
mini-USB cable, shoulder strap, belt strap, magnetic hanging strap,
software, soft carrying case, spare fuses (2), battery tags, and zero ohm
calibration resistor
FLUKE-BT510 Battery Analyzer
4-wire test pin (set), est lead (set), test leads with adapter, lithium-ion
battery, ac charger, mini-USB cable, shoulder strap, belt strap, magnetic
hanging strap, software, soft carrying case, spare fuses (2), and zero ohm
calibration resistor
Measure impedance with
the Fluke BT521 Battery
Analyzer.
www.fluke.com/batteryanalyzers Battery Analyzers
54
PROCESS TOOLS SELECTION GUIDE
Models
Process mA
Clamp Meter
ProcessMeter®
Test Tool
Loop
Calibrator
Pressure
Calibrator
Temperature
Calibrator
Precision
Multifunction
Process
Calibrator
Intrinsically
Safe
Calibrator
Documenting
Process
Calibrator
773 789 709H 719/719PRO 724 726 725Ex 754
Measure
V dc 30 V 1000 V 30 V 30 V 30 V 30 V 300 V
V ac (true-rms) 1000 V 300 V
Resistance 40 M 3200 Ω 4000 3200 Ω 11 k
A dc max 20.99,
99.9 mA 30 mA, 1 A 24 mA 24 mA 24 mA 24 mA 24 mA 110 m A
A ac max
Frequency 20 kHz 15 kHz 10 kHz 50 kHz
Pressure 2 bar, 10 bar,
20 bar 131
Temperature: RTDs 719Pro
optional 7 types 8 types 7 types 8 types
Temperature: TCs 12 types 13 types 12 types 13 types
Source/Simulate
V dc 10 V 10 V 20 V 10 V 15 V
Resistance 3200 4000 Ω 3200 11 k
mA dc 24 mA 24 mA 24 mA 24 mA 24 mA 24 mA 22 mA
mA source; auto step,
auto ramp
Frequency 15 kHz 10 kHz 50 kHz
Temperature: RTDs 7 types 8 types 7 types 8 types
Temperature: TCs 12 types 13 types 12 types 13 types
Record
Min/Max
Hold 719
As found/As left results
Log data
Upload data to PC
Remote operation
Features
24 V loop supply 12 V 26 V
Non-contact mA
measurement
HART communication
Intrinsically safe (ATEX)
Traceable calibration
certification
Pressure enabled2 3
Warranty (years) 3 3 3 3 3 3 3 3
1Fluke 750P Pressure Modules required.
2Fluke Process Calibrators in this guide displaying the Pressure Enabled symbol display readings from the 750P Series Pressure Modules.
3Fluke 700PEx Pressure Module required.
Model
914X/
9190A P3000 152X
9103/
9140 418X 1620A P5500 3130 2700G 1586A
Range 95 °C to
660 °C
To 400
MPa
(60,000
psi)
–200 °C to
420 °C
–25 °C to
350 °C
15 °C to
500 °C
0 °C to
50 °C; 0 %
to 100 % RH
To 70 MPa
(20,000 psi)
Vacuum to
20 bar
-0.1 to 70
MPa (-15 to
10,000 psi)
Various
Measure
Temperature
Pressure
Humidity
DC volt/
current
Source
Temperature
Pressure
Thermocouple
55
Process Calibration Tools
www.fluke.com/773
PROCESS CALIBRATION TOOLS
General specifications
771 772 773
Battery Two 1.5 V, Alkaline, IEC
LR6 Four 1.5 V, Alkaline, IEC LR6
Working hours 20 hours typical 12 hours @ 12 mA source into 500 ohms
Size (HxWxL) 59 mm x 38 mm x 212 mm
(2.32 in x 1.5 in x 8.35 in)
41.3 mm x 76 mm x 248 mm
(1.625 in x 3 in x 9.75 in)
Weight 260 g (9.1 oz) 415 g (14 oz)
Operating temperature -10 °C to 50 ºC
IP rating IP 40
Warranty Three-year, one-year on mA clamp assembly and cable
Fluke 771, 772 and 773 mA Process Clamp Meters
Measure output signals without breaking the loop
The Fluke 771, 772 and 773 mA Process Clamp Meters pay for themselves. These meters save
time by measuring 4 to 20 mA signals (five) times faster than traditional DMMs without opera-
tor intervention, offering loop calibration, voltage testing and eliminate time wasting activities.
Use the Fluke 771, 772 and 773 to:
Measure 4-20 mA signals without ”breaking the loop,” save time and money troubleshooting
Use the Fluke 772 and 773 to:
Source 4-20 mA signals for testing control system I/O or I/Ps
Simulate 4-20 mA signals for testing control system I/O
Measure 4-20 mA signals with in-circuit measurement
Power a transmitter with the 24 V loop power supply
Automatically ramp and step change the 4-20 mA output for remote testing
Use the Fluke 773 to:
Measure dc voltage to verify 24 V power supplies or voltage I/O signals
Source dc voltage to test voltage input devices
Scaled mA output signal enables a logging DMM (289) or 709H Precision Loop Calibrator to
record 4-20 mA signal without breaking the loop
mA in/out: simultaneously source a mA signal while measuring a mA signal with the clamp
Features
mA
measure
w/jaw
mA
measure
In circuit
mA
source mA sim
Loop
power
24 V
DCV
source
0-10 V
DCV
measure
0-30 V
Scaled
mA output
to mA
input mA in/out
771
772
773 •••••••••
Specifications
Function
Resolution
and range Accuracy Notes
771, 772,
773 mA measurement 0 mA to 20.99 mA 0.2 % + 5 counts Measured by clamp
21.0 mA to 100.0 mA 1 % + 5 counts
772 and 773 mA measurement 0 mA to 24.00 mA 0.2 % + 2 counts Measured in series with test jacks
772 and 773 mA source 0 mA to 24.00 mA 0.2 % + 2 counts Maximum mA drive: 24 mA into
1,000 ohms
772 and 773 mA simulate 0 mA to 24.00 mA 0.2 % + 2 counts Maximum voltage 50 V dc
773 Voltage source 0 V dc to 10.00 V dc 0.2 % + 2 counts 2 mA maximum drive current
773 Voltage measure 0 V dc to 30.00 V dc 0.2 % + 2 counts
Ordering information
Models Included accessories
FLUKE-771 Milliamp Process Clamp Meter Soft carrying case, users manual
FLUKE-772 Milliamp Process Clamp Meter Test leads, alligator clips and hanging strap, soft carrying case,
users manual
FLUKE-773 Milliamp Process Clamp Meter
Measure process and
other automation 4 to
20 mA signals without
breaking the loop.
Instrument CarePlan
56 www.fluke.com/processmeters
Process Calibration Tools
PROCESS CALIBRATION TOOLS
Fluke 789 and 787 ProcessMeter Test Tools
Combine the functionality of a loop calibrator with the power of a digital
multimeter
Fluke 789 ProcessMeter
The Fluke 789 ProcessMeter is the ultimate troubleshooting tool for process technicians.
Add the wireless data logging capabilities of Fluke Connect® with ShareLive video call, and
process technicians can do a lot more while carrying a lot less.
Unique new wireless measurement logging capability
24 V loop power supply
HART mode setting with loop power (adds 250 ohm resistor)
20 mA drive into 1200 ohms
0 % to 100 % mA Span Check buttons to toggle between 4-20 mA
Infrared I/O serial port compatible with FlukeView® Forms Software
Fluke 787 ProcessMeter
Simultaneous mA and % of scale readout on mA output
25 % Manual Step plus Auto Step and Auto Ramp on mA output
Min/Max/Avg/Hold/Relative modes
Specifications
Measurement function Best accuracy range and resolution (% of reading + LSD)
V dc 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V 0.1 % + 1
V ac (true-rms) 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V 0.7 % + 2
mA dc 30.000 mA .05 % + 2
A dc 1.000 A (0.440 A continuous) 0.2 % + 2
A ac 1.000 A (0.440 A continuous) 1 % + 2
Resistance 400.0 Ω, 4.000 kΩ, 40.00 kΩ,
400.0 kΩ, 4.000 MΩ, 40.00 MΩ 0.2 % + 1
Frequency (0.5 Hz to 20 kHz) 199.99 Hz, 1999.9 Hz, 19.999 kHz 0.005 % + 1
Diode test 789: 2.000 V (shows diode voltage drop)
787: 2.400 V (shows diode voltage drop) 2 % + 1
Continuity Beeps for resistance < approx. 100 ohms
Output function Range and resolution Drive capability Accuracy
(% of span)
DC current output-source
mode (internal battery
operation)
0.000 mA to 20.000 mA or 4.000 mA to
20.000 mA (selectable at power-up)
Over-range to 24.000 mA
789: 24 V compliance
or, 1,200 ohms,
@ 20 mA 787: 12 V
compliance or,
500 ohms, @ 20 mA
0.05 %
DC current output-simulate
mode (external 24 V loop
supply, up to 48 V on 789
only)
0.000 mA to 20.000 mA or 4.000 mA to
20.000 mA, (selectable at power-up) Over-
range to 24.000 mA
1000 ohms, @ 20 mA 0.05 %
24 V loop supply 789: Minimum 24 V, 787: Not available 250 ohms @ 20 mA > 24 V
Current adjustment modes Manual: coarse, fine, 25 % and 100 % step (100 % step 789 only)
Automatic: slow ramp, fast ramp, 25 % step
General specifications
Temperature range 18 °C to 28 °C for one year after calibration
Maximum voltage 1000 V rms (applied between any jack and earth ground)
Temperature -40 °C to 60 °C (storage); -20 °C to 55 °C (operating)
Relative humidity 95 % up to 30 °C; 75 % up to 40 °C; 45 % up to 50 °C; 35 % up to 55 °C
Safety IEC 61010-1: 600 V CAT IV / 1000 V CAT III
Size (HxWxL)/weight (787 w/ holster) 52 mm x 98 mm x 201 mm (2.06 in x 3.86 in x 7.93 in)/638 g (1.4 lb)
Size (HxWxL)/weight (789) 50 mm x 100 mm x 203 mm (1.97 in x 3.94 in x 8.00 in)/600 g (1.3 lb)
Warranty Three-year
True
Instrument CarePlan
Ordering information
Models Included accessories
FLUKE-789 ProcessMeter Test leads, alligator clips, 4 AA alkaline batteries (installed), quick reference guide, users
manual, multi-language manual CD
FLUKE-787 ProcessMeter Test leads, alligator clips, holster with test lead storage, one 9 V alkaline battery
(installed), quick reference guide, users manual, multi-language manual CD
(789)(787)
Fluke 789 ProcessMeter is
two tools in one, a CAT IV
600V safety rated DMM
and a full functioning mA
loop calibrator. Perfect
for instrumentation and
I and E technicians.
(789 only)
57
Fluke 715, 707 and 705 Loop Calibrators
Delivers outstanding performance, durability and reliability
Fluke 715 Loop Calibrator
The Fluke 715 Volt/mA Calibrator can measure loop current as well as voltage output.
Source voltage to 200 mV or 20 V
Measure loop current (0-20 mA, 4-20 mA) signals with 0.01 % accuracy and 1 µA resolution
Measure voltage output process signals from PLCs, transmitters
Source or simulate 4-20 mA loop current
24 V loop supply with simultaneous current measurement
Ramp and Step Ramp output functions
Fluke 707 and 705 Loop Calibrators
With large displays and simple interface, the Fluke 707 and 705 provide easy to use,
one-hand operation.
Innovative output adjustment dial on 707 for 1 μA and 100 μA resolution
Simultaneous mA and % readout for quick, easy interpretation of readings
mA accuracy of 0.015 % on the Fluke 707 and 0.02 % on the 705
HART™ mode on 707 connects 250 ohm resistor in series with 24 V loop for compatibility
with HART communicators
Push button 25 % steps for fast, easy linearity checks
Span Check” for fast confirmation of zero and span
Selectable slow and fast linear step ramp provide ramping outputs for valve slewing, remote
testing and loop functional tests
24 V internal loop supply, so you can power and read a transmitter at the same time
without carrying a DMM
0-20 mA or 4-20 mA default start up modes
Specifications
Functions Fluke 705 and 707 Fluke 715
Voltage measurement
Range 0 V to 28 V 0 mV to 200 mV 0 V to 25 V
Resolution 1 mV 10 µV 1 mV
Accuracy 705: 0.025 % Rdg + 1 LSD 707,
707Ex: 0.015 % Rdg + 2 LSD 0.01 % Rdg + 2 LSD
Current measurement
Range 0 mA to 24 mA 0 mA to 24 mA
Resolution 0.001 mA 0.001 mA
Accuracy 705: 0.02 % Rdg + 2 LSD 707,
707Ex: 0.015 % Rdg + 2 LSD 0.01 % + 2 LSD
Current sourcing
Range 0 mA to 20 mA or 4 mA to 20 mA 0 mA to 20 mA or 4 mA to 20 mA
Accuracy 705: 0.025 % Rdg + 2 LSD 707,
707Ex: 0.015 % Rdg + 2 LSD 0.01 % Rdg + 2 LSD
Drive capability 705: 1000 W @ 24 mA 707: 1200 W
@ 24 mA 707Ex: 700 W @ 20 mA 1000 W @ 24 mA
Loop power while
measuring mA 24 V 24 V
Voltage sourcing 0 mV to 200 mV or 0 V to 20 V
Display current
and % of span mA or %
Auto step, auto ramp
Span Check
Battery life 18 hours typical at 12 mA 18 hours typical at 12 mA
Warranty Three-year
Instrument CarePlan
Ordering information
Models Included accessories
FLUKE-715 Volt/mA Calibrator
Test leads, alligator clips, holster, traceable calibration report and data, single 9 V
alkaline battery, instruction sheet (14 languages)
FLUKE-707 Loop Calibrator
FLUKE-705 Loop Calibrator
Fluke loop calibrators are
reliable and accurate. The
709H adds basic HART
communication (see page 58).
Process Calibration Tools
www.fluke.com/loop
PROCESS CALIBRATION TOOLS
58 www.fluke.com/754
Process Calibration Tools
PROCESS CALIBRATION TOOLS
75X Calibrator Specifications
Measure Sourcing
DC voltage 0.020 % reading +
0.005 % full scale
0.01 % output +
0.005 % full scale
DC current 0.01 % reading +
5 µA
0.01 % output +
0.003 mA
Resistance 0.05 % reading + 50 mΩ 0.01 % output + 240 mΩ
Frequency 0 to 50 KHz, ± 0.5 Hz to 1100 Hz 0 to 50 KHz, ± 0.1 Hz to 1099.9 Hz
Thermocouples 0.3 °C 0.2 °C
RTDs 0.3 °C 0.1 °C
Pressure To 0.025 % of full scale, per pressure
module specifications (Fluke 750P Series)
Battery life Typically over eight hours
Internal battery pack Li ion 4400 mAh
Size (HxWxD) 245 mm x 136 mm x 63 mm (9.6 in x 5.4 in x 2.5 in)
Weight 1.2 kg (2.7 lb)
Calibration cycles One- and two-year
Warranty Three-year
Fluke 753 and 754 Calibrators
Does the work of several tools for process systems
Calibrate temperature, pressure, voltage, current, resistance and frequency instruments
Built-in procedures for transmitters, square root transmitters, pressure and temperature
switches
Simultaneously measure and source
Automatically capture calibration results
Document procedures and results to meet ISO 9000, EPA, FDA, OSHA and other requirements
Measure/simulate 13 types of thermocouples and eight RTDs
754: Get HART-ability
The Fluke 754 offers all of the capabilities of the 753, plus the ability to calibrate, maintain
and troubleshoot HART instrumentation. Integrated HART communication functions permit
you to monitor, control and calibrate HART instrumentation. It handles fast pulsed instruments
such as RTD transmitters and PLCs responding to pulses within 1 ms.
753: A complete documenting calibrator
The 753 is a complete multifunction documenting calibrator and includes a PC interface that
lets you load procedures, lists and instructions created with softwareor unload data for
printing, archiving, and analysis. The 753 can hold a full week of calibrations and procedures.
Fluke 709/709H Precision Current Loop Calibrators
Best-in-class accuracy at 0.01 % reading
HART Communication (709H only) communicate with and test HART smart instruments
24 V dc loop power with mA measure mode
Built in selectable 250 Ω resistor for HART communications
Valve test (source and simulate defined mA values with % keys)
Upload logged mA measurements and HART device data using the 709H with optional
709H/TRACK software
HART is a registered trade mark of the HART Communications Foundation.
Instrument CarePlan
Ordering information
Models Included accessories
FLUKE-754 Documenting Process Calibrator-HART
Three sets of stackable test leads, three sets of test probes
with three sets of “extended tooth” alligator clips, two sets of
hook clips, li-ion battery pack, battery charger, field soft case,
USB communication cable, getting started guide, instruction
manual on CD, traceable certificate of calibration, DPC/TRACK2
sample software that enables upload and printing of calibration
records. HART communication cable (754 only)
FLUKE-753 Documenting Process Calibrator
FLUKE-709 Precision Current Loop Calibrator Test leads, test probes and alligator clips. Quick reference guide,
traceable certificate of calibration, manual on CD. Additional
hook clips (709H only) for HART communication
FLUKE-709H Precision Current Loop Calibrator-HART
Calibrate and document
the performance of HART
smart pressure transmitters
with the Fluke 754 and 750
Series Pressure Modules.
59
Process Calibration Tools
www.fluke.com/726
Fluke 726 and 725 Multifunction Process
Calibrators
Calibrate almost anything
The Fluke 726 and 725 measure and source nearly all process parameters. Interpret results
without the help of a calculator and store measurement data for later analysis.
Precise measurement and calibration source performance, accuracies of 0.01 % (726)
Transmitter error % calculation, source/simulate volts, mA, thermocouples, RTDs, frequency,
ohms and pressure to calibrate transmitters
Memory storage for up to eight calibration setups
Frequency totalizer and pulse train source mode for enhanced flowmeter testing (726)
HART mode inserts 250 ohm resistor in mA measure and source mode
Integrated pressure switch test to capture the set, reset and deadband of a switch (726)
RTD curves, add temperature calibration constants for certified RTD probes
Voltage input protection design for improved reliability
Measure/source pressure using any of 50 Fluke 750Pxx Pressure Modules
Source mA with simultaneous pressure measurement to conduct valve and I/P tests
Perform fast linearity tests with auto step and auto ramp features
Intrinsically safe version available (725)
Measure and source
Functions Range or type Resolution Accuracy Notes
Voltage dc
0 to 100 mV
0 to 10 V (source)
0 to 20 V (source)
0 to 30 V (measure)
0.001 mV
0.001 V
0.001 V
0.001 V
0.01 %,
0.02 %
Rdg + 2 LSD
Max load, 1 mA
mA 0 to 24 0.001 mA
0.01 %,
0.02 %
Rdg + 2 LSD
Max load, 1000 Ω
mV (TC
terminals)
-10.00 mV to
+75.00 mV .01 mV 0.01 %, 0.02 %
of range + 1 LSD
Ohms 15 Ω to 3,200 Ω
5 Ω to 4,000 Ω
0.01 Ω
to 0.1 Ω
0.10 Ω to 1.0 Ω
0.015 %
Hz - CPM
2.0 to 1,000 CPM
1 to 1000 Hz
1.0 to 10.0 kHz
10.0 to 15.0 kHz
0.1 CPM
1 Hz
0.1 kHz
0.1 kHz
± 0.05 %
± 0.05 %
± 0.25 %
± 0.05 %
Source;
5 V p-p
1 V to 20 V p-p
squarewave,
-0.1 V offset
Loop supply 24 V dc N/A 10 %
T/C J, K, T, E, L, N, U, XK 0.1 °C, 0.1 °F to 0.7 °C
to 0.2 °C
T/C B, R, S, BP 1 °C, 1 °F to 1.7 °C
to 1.2 °C
RTDs
Cu (10), Ni120 (672)
Pt 100, 200, 500,
1000 (385)
Pt 100 (3916),
Pt 100 (3926)
0.01 °C,
0.01 °F
0.1 °C, 0.1 °F
to 0.15 °C
to 0.2 °C
Instrument CarePlan
Ordering information
Models Included accessories
FLUKE-726 Precision Multifunction Process Calibrator Test leads, test clips, one pair of stackable test leads, traceable
certificate of calibration, product overview manual, users
manual in 14 languages on CD
FLUKE-725 Multifunction Process Calibrator
General specifications
Storage/operating temperature -20 °C to 71 °C/-10 °C to 55 °C (726: -10 °C to 50 °C)
Relative humidity 90 % (10 °C to 30 °C); 75 % (30 °C to 40 °C); 45 % (40 °C to 50 °C);
35 % (50 °C to 55 °C)
Shock 1 meter drop test
Battery life 25 hours typical (4 AA alkaline batteries)
Size (HxWxD) 200 mm x 96 mm x 47 mm (7.9 in x 3.8 in x 1.9 in)
Weight 650 g (23 oz)
Warranty Three-year
(725)
Add a 750P series pressure
module to the 725 or 725 to
make it a pressure calibrator.
Calibrate temperature
transmiters easily with Fluke
725 and 726 calibrators.
Unique 726 specifications are bold.
PROCESS CALIBRATION TOOLS
60 www.fluke.com/temperaturecal
Process Calibration Tools
PROCESS CALIBRATION TOOLS
Fluke 712B, 714B and 724 Temperature
Calibrators
Highly accurate single function temperature calibrator
For the temperature calibration professional that wants a highly accurate, easy-to-use, single
function temperature calibrator the 712B and 714B are ideal. For temperature calibration
professionals, these temperature calibrators deliver outstanding performance, durability and
reliability and each calibrator is EMI tolerant, dust- and splash-resistant, and features a remov-
able battery door for quick battery changes.
The 712B can measure and simulate (13) different RTD types and resistance
The 714B can measure and simulate (17) different thermocouple types and millivolts
Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal
The 724 specialty model will source/measure TCs, RTDs, volts and ohms as well as measure
mA while supplying loop power
Hanging tool designed in and included with every unit (712B and 714B)
Configurable 0 % and 100 % source settings for quick 25 % linearity checks
Linear ramp and 25 % step auto ramp based on 0 % and 100 % settings
Dual inputs and backlit display for easy interpretation of measurements
Power down settings remembered at power up for easy restart of tests
One-year and two-year specifications and traceable certificate of calibration (712B and 714B)
Specifications
Functions Range Resolution Accuracy Notes
712B
Measure/Simulate
RTD
-200 °C to 800 °C
(Pt 100-385)
0.1 °C,
0.1 °F
0.2 °C, 0.4 °F
(Pt 100-385)
13 types Pt; 100
200 500
1000 (385); Pt 100
(392); Pt 100 (392) JIS;
Ni 120 (672)
Measure/Simulate
Resistance
0.00 Ω to 400.00 Ω 0.01 Ω 0.015 % + 0.005 Ω
400.0 Ω to 4000.0 Ω 0.1 Ω 0.015 % + 0.05 Ω
714B
Measure/Simulate
Thermocouple
-200 °C to 1800 °C,
depending on type
(K, -200 °C to
1370 °C)
0.1 °C or °F
(1 °C or °F;
BRS)
0.5 °C, 0.8 °F (Type K)
17 TC types; J K T E R
S B per NIST 175 and
ITS-90 L U per DIN
43710 and PTS-68
Measure/Simulate
mV 10 mV to 75 mV 0.01 mV 0.015 % + 10 μV
General specifications (712B/714B)
Maximum voltage 30 V
Operating temperature -10 °C to 50 °C
Power 4 AA alkaline batteries/NEDA code: 15A, IEC code: LR6
Safety/EMC IEC 61010-1, Max 30 V to earth, Pollution Degree 2/IEC 61326-1, Portable
Size (HxWxD) 188.5 mm x 84 mm x 52 mm (7.42 in x 3.31 in x 2.04 in)
Weight 515 g (18.16 oz)
Warranty Three-year
Ordering information
Models Included accessories
FLUKE-724 Temperature Calibrator Test leads, test clips, one pair of stackable test leads, product
overview manual, users manual in 14 languages on CD
FLUKE-714B Themocouple Calibrator Test leads, alligator clips (excluding model 714), holster with
test lead storage, single 9 V alkaline battery and instruction
sheet (14 languages)
FLUKE-712B RTD Calibrator
714B is the ideal tool for
testing thermocouple input
temperature transmitters.
61
Process Calibration Tools
www.fluke.com/processtools
Fluke Calibration Temperature Sources
9142/9143/9144 Field Metrology Wells
Small dry wells for big field applications
Applications: Temperature instrument calibration, 4 to 20 mA loop test and calibration,
temperature switch testing.
Cool to -25 °C in 15 minutes (9142) and heat to 660 °C in 15 minutes (9144)
Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current
Stability to ± 0.01 °C
Accredited calibration
9103/9140 Field Dry-Well Calibrators
Portable instruments with great performance
Applications: Temperature instrument calibration, temperature switch tests.
Two models ranging from -25 °C to 350 °C
Accuracy to ± 0.25 °C
Stability to ± 0.02 °C
4180/4181 Precision Infrared Calibrators
Accredited performance for point-and-shoot calibrations
Applications: Infrared thermometer calibration.
Calibrated radiometrically for meaningful, consistent results
Accredited calibration accurate to ± 0.35 °C
Wide coverage -15 °C to 500 °C
Stability to ± 0.01 °C
9190A Ultra-Cool Field Metrology Well
Ultra-cool dry-block calibrator with best-in-class stability
Applications: Temperature instrument calibration, 4-20 mA loop test and calibration.
Wide temperature range: -95 °C to 140 °C
Accuracy to ± 0.05 °C
Fast cooling time from 23 °C to -95 °C: 90 minutes
Pair the Fluke 753 or 754
with a dry-well calibrator
to calibrate and document
both temperature
transmitter electronics
and sensor performance.
Ordering information
Models Select an insert Included accessories
9103 Field Dry-Well Calibrator,
–25 °C to 140 °C
Insert A: 1/16 in (1.6 mm), 1/8 in (3.2 mm),
3/16 in (4.8 mm), 1/4 in (6.35 mm), 3/8 in
(9.5 mm) and 1/2 in (12.7 mm) Insert, insert removal tool, software,
calibration certificate
9140 Field Dry-Well Calibrator,
35 °C to 350 °C Insert C: 6 at 1/4 in (6.35 mm)
9190A Field Metrology Well,
-95 °C to 140 °C 9190-INSA: imperial misc holes Insert, insert removal tool, manual,
software, USB cable, accredited
calibration certificate
9190A-P Field Metrology Well,
-95 °C to 140 °C, process version 9190-INSC: 6 x 0.25 in holes
9142 Field Metrology Well,
-25 °C to 150 °C 9142-INSA, imperial misc holes Insert, insert removal tool, test
lead kit (process version), software,
manual, accredited calibration
certificate
9142-P Field Metrology Well,
-25 °C to 150 °C, process version
9142-INSB, imperial comp holes
9142-INSC, 6 x 0.25 in holes
9143 Field Metrology Well,
33 °C to 350 °C 9143-INSA, imperial misc holes Insert, insert removal tool, test
lead kit (process version), software,
manual, accredited calibration
certificate
9143-P Field Metrology Well,
33 °C to 350 °C, process version
9143-INSB, imperial comp holes
9143-INSC, 6 x 0.25 in holes
9144 Field Metrology Well,
50 °C to 660 °C 9144-INSA, imperial misc holes Insert, insert removal tool, test
lead kit (process version), software,
manual, accredited calibration
certificate
9144-P Field Metrology Well,
50 °C to 660 °C, process version
9144-INSB, imperial comp holes
9144-INSC, 6 x 0.25 in holes
4180 Precision Infrared
Calibrator, –15 °C to 120 °C N/A
Report of Calibration (NVLAP
accredited), power cord, user’s guide,
documentation CD, target cover,
serial cable
4181 Precision Infrared
Calibrator, 35 °C to 500 °C
PROCESS CALIBRATION TOOLS
62 www.fluke.com/pressurecal
Process Calibration Tools
PROCESS CALIBRATION TOOLS
1523 and 1524 Reference Thermometers
Measure, graph and record three sensor types with one tool
Get plug and play measurement of PRTs, RTDs, Thermistors, and Thermocouples with high
accuracy. The model 1524 has two channels so you can do twice the work in half the time.
Both instruments are handheld and battery powered with the option of using an included
ac adapter.
1586A Super-DAQ Precision Temperature
Scanner
Use as a multi-channel data logger in the factory or as a precision reference
thermometer in the lab
The 1586A is the most accurate (± 0.002 °C), secure and flexible temperature data acquisi-
tion system on the market. The 1586A Super-DAQ scans and records temperature (PRTs,
Thermocouples, and Thermistors), dc voltage, dc current, and resistance for up to 40 input
channels and scan speeds as fast as 10 channels per second. The 20 channel High-
Capacity Modules are for data logging, and 20 channel DAQ-STAQ Multiplexer is for lab
applications.
7526A Precision Process Calibrator
The 7526A offers the best balance of economy and accuracy for bench top calibration of
temperature and pressure process instrumentation. Easily calibrate RTD and thermocouple
readouts, pressure gauges, temperature transmitters, digital process simulators, data
loggers, multimeters and more.
1551A Ex and 1552A Ex “Stik” Thermometers
The easiest to use precision thermometer
Intrinsically safe (ATEX and IECEx compliant) with user-configurable temperature Trend/
Stability indicator, 300-hour battery life, and optional data logging.
Ordering information
Models Included accessories
1523P1 1 channel thermometer readout bundle 5616 PRT, Smart connector for thermocouples,
TPAK, and case
1524-P1 2 channel thermometer readout bundle
1586A/1HC 120 Super-DAQ Precision Temperature Scanner, 120 V High-Capacity Module, software CD
1586A/1HC 120/C Super-DAQ Precision Temperature Scanner, 120 V High-Capacity Module, Accredited Calibration,
software CD
1586A/1DS 120 Super-DAQ Precision Temperature Scanner, 120 V DAQ-STAQ Multiplexer, software CD
1586A/1DS 120/C Super-DAQ Precision Temperature Scanner, 120 V DAQ-STAQ Multiplexer, Accredited Calibration,
software CD
1586A/2HC 120 Super-DAQ Precision Temperature Scanner, 120 V 2 High-Capacity Modules, software CD
1586A/2HC 120/C Super-DAQ Precision Temperature Scanner, 120 V 2 High-Capacity Modules, Accredited Calibration,
software CD
1586A/2DS 120 Super-DAQ Precision Temperature Scanner, 120 V 2 DAQ-STAQ Multiplexers, software CD
1586A/2DS 120/C Super-DAQ Precision Temperature Scanner, 120 V 2 DAQ-STAQ Multiplexers, Accredited
Calibration, software CD
1586-CASE 1586A Super-DAQ Carrying Case Carrying case
1586/DS-CASE 1586A Super-DAQ/DAQ-STAQ Carrying Case Carrying case
7526A Precision Process Calibrator USB to serial adapter cable, thermocouple
shorting jumper
7526A-CASE 7626A Carrying Case Carrying case
1551A-9 Digital Thermometer, 9 in, –50 °C to 160 °C (-58 °F to
320 °F) RS-232 cable, 3 AAA batteries
1551A-12 Digital Thermometer, 12 in, –50 °C to 160 °C (-58 °F to
320 °F) RS-232 cable, 3 AAA batteries
1552A-12 Digital Thermometer, 12 in, -80 °C to 300 °C ( -112 °F to
572 °F RS-232 cable, 3 AAA batteries
1551-CASE 1551/1552 Carrying Case Carrying case
63
Fluke Pressure Calibrators
Fluke 719 and 719PRO Electric Pressure Calibrators
Electric pump enables one-handed pressure pumping
Best in class 0.025 % pressure measurement accuracy
Programmable pump limit settings can eliminate over-pressurization
Precision vernier for fine pressure adjustment
Variable release rate bleed valve for controlled pressure release
Pressure switch test makes a difficult task easy, captures set, reset and deadband values of
a pressure switch
Measure mA with 0.015 % accuracy, while sourcing 24 V loop power
719: Two ranges, 30 psi and 100 psi
719PRO: Three ranges 30 psi, 150 psi and 300 psi
719PRO: Precision temperature measurement with optional 720RTD Probe
Fluke 718 Pressure Calibrators
1, 30, 100 and 300 psi ranges available
Pump to 300 psi, 20 bar with internal hand pump (718-300G)
718-1G includes special low volume pump and high measurement resolution for low
pressure calibration
Precision vernier for fine pressure adjustment
Variable release rate bleed valve for controlled pressure release
Pressure switch test makes a difficult task easy, captures set, reset and deadband values of
a pressure switch
Measure pressure to 0.025 % of full scale
Measure mA with 0.015 % accuracy, while sourcing 24 V loop power
Fluke 717 Pressure Calibrators
Measure up to 10,000 psi/690 bar sensor (10000G model)
Compatible with non-corrosive gases and liquids on 500 psi and higher ranges
Pressure switch test makes a difficult task easy, captures set, reset and deadband values of
a pressure switch
Measure pressure to 0.025 % of full scale
Measure mA with 0.015 % accuracy, while sourcing 24 V loop power
Fluke 750P Series Pressure Modules
50 pressure modules covers pressure calibrations from 0 to 1 in H20 to 10000 psi 2.5 mBar to
690 bar.
0.025 % reference uncertainty
6-month and 1-year specifications
Temperature compensated 0 °C to 50 °C
Digital communication to calibrators, no analog losses or errors
Gage, differential, dual range, absolute and vacuum measurement models
Ordering information
Models Included accessories
FLUKE-719PRO 30G Electric Pressure Calibrator FLUKE-717 15G Pressure Calibrator
Test leads, alligator clips,
holster, test hose (719),
one 9 V alkaline battery
(two 9 V batteries in 718
and 719), 8 AA batteries
in the 719PRO and safety
sheet.
FLUKE-719PRO 150G Electric Pressure Calibrator FLUKE-717 30G Pressure Calibrator
FLUKE-719PRO 300G Electric Pressure Calibrator FLUKE-717 100G Pressure Calibrator
FLUKE-719 30G Electric Pressure Calibrator FLUKE-717 300G Pressure Calibrator
FLUKE-719-100G Electric Pressure Calibrator FLUKE-717 500G Pressure Calibrator
FLUKE-718 1G Pressure Calibrator FLUKE-717 1000G Pressure Calibrator
FLUKE-718 30US Pressure Calibrator FLUKE-717 1500G Pressure Calibrator
FLUKE-718 100US Pressure Calibrator FLUKE-717 3000G Pressure Calibrator
FLUKE-718 300G Pressure Calibrator FLUKE-717 5000G Pressure Calibrator
FLUKE-717 1G Pressure Calibrator FLUKE-717 10000G Pressure Calibrator
For a full list of Fluke 750P Series Pressure Calibrators, visit www.fluke.com/pressure.
Instrument CarePlan
Process Calibration Tools
www.fluke.com/pressurecal
PROCESS CALIBRATION TOOLS
64 www.fluke.com/pressurecal
Process Calibration Tools
PROCESS CALIBRATION TOOLS
Fluke 700G Series Precision Pressure Test Gauges
Twenty three ranges to choose from
Seven Reference Class gauge ranges with ± .04 % of reading accuracy: 30 psi, 100 psi,
500 psi, 1000 psi, 3000 psi, 5000 psi, 10000 psi
Two Low pressure measurement ranges with ± .1 of reading accuracy: 10 inH2O, 1 psi
Fourteen precision test gauge ranges with ± .05% of reading accuracy: 15 psi, 30 psi,
100 psi, 300 psi, 500psi, 1000 psi, 2000 psi, 3000 psi, 5000 psi, 10000psi
Four Absolute pressure measurement ranges: 15 psia, 30 psia, 100 psia, 300 psia
CSA; Class 1, Div 2, Groups A-D rating
ATEX rating: II 3 G Ex nA IIB T6
Combine with the 700PTPK or 700HTPK pump kits for a complete pressure testing solution
for up to 600 psi (40 bar) with the 700PTP-1 pneumatic pump and up to 10,000 psi (690
bar) with the 700HTP-2 hydraulic pump
Log up to 8,493 pressure measurements to memory (requires 700G/TRACK software)
Three-year warranty
Fluke 721 Precision Pressure Calibrator
Features dual-range isolated pressure sensors
Ideal tool for gas custody transfer applications
Take simultaneous static and differential pressure measurements with a single tool
Best in class accuracy of 0.025 %, for gas measurement applications
Pt100 RTD input for precision temperature measurement (probe optional)
Measures 4 to 20 mA signals and provides 24 V loop power
Measure up to 30 V dc to check 24 V loop power supplies
Extend pressure measurement range with connection to external 750P Series Pressure
Modules (50 ranges)
I.S. rated models available. IS models do not have 24 V loop power, measure voltage or have
connectivity to pressure modules
Specifications
Low pressure sensor High pressure sensor
Model
Range
sensor 1
Resolution
sensor 1
Accuracy
sensor 1 Range Sensor 2
Resolution
sensor 2
Accuracy
sensor 2
Fluke-721-1601
-14 psi to
+16 p si
0.001 psi 0.025 % of
full scale
-12 psi to +100 psi 0.01 psi
0.025 % of
full scale
Fluke-721-1603 -12 psi to +300 psi 0.01 psi
Fluke-721-1605 -12 psi to +500 psi 0.01 psi
Fluke-721-1610 0 psi to +1000 psi 0.1 psi
Fluke-721-1615 0 psi to +1500 psi 0.1 psi
Fluke-721-1630 0 psi to +3000 psi 0.1 psi
Fluke-721-1650 0 psi to +5000 psi 0.1 psi 0.035 % of
full scale
Fluke-721-3601
-14 psi to
+36 psi
-12 to +100 psi 0.01 psi
0.025 % of
full scale
Fluke-721-3603 -12 psi to +300 psi 0.01 psi
Fluke-721-3605 -12 psi to +500 psi 0.01 psi
Fluke-721-3610 0 psi to +1000 psi 0.1 psi
Fluke-721-3615 0 psi to +1500 psi 0.1 psi
Fluke-721-3630 0 psi to +3000 psi 0.1 psi
Fluke-721-3650 0 psi to +5000 psi 0.1 psi 0.035 % of
full scale
Instrument CarePlan
Ordering information
Models Included accessories
FLUKE-721 Precision Pressure Calibrator (all models) Soft case, Four (4) AA batteries, manual, traceable calibration
certificate, test leads
FLUKE-700G/700RG Precision Pressure Test Gauges
(all models)
Manual on CD-ROM in 14 languages, traceable certificate of
calibration, 1/4 in NPT to 1/4 in ISO adapter
For a full list of Fluke 750P Series Pressure Modules, visit www.fluke.com/pressure.
65
2700G Series Reference Pressure Gauges
Best-in-class measurement performance
The 2700G Reference Pressure Gauges provide best-in-class measurement performance in a
rugged, easy-to-use, economical package. The 2700G is ideal for calibrating pressure gauges,
transmitters, transducers, and switches. In addition, it can be used for data logging.
Precision pressure measurement from 115 psi to 10,000 psi
Accuracy to 0.02 % of full scale
Combine with a Fluke PTP or HTP pump kit or P551X comparison test pump for a complete
pressure testing solution
Ordering information
Models Included accessories
2700G-BG100K Reference Pressure Gauge, -15 to 15 psi (-100 to 100 kPa)
Manual on CD-ROM in 14 languages,
calibration certificate, ¼ NPT female to
¼ BSP male adapter, ¼ NPT female to
M2OX1.5 adapter, universal ac power
supply, USB communication cable
2700G-BG200K Reference Pressure Gauge, -15 to 30 psi (-100 to 200 kPa)
2700G-BG700K Reference Pressure Gauge, -12 to 100 psi (-80 to 700 kPa)
2700G-BG2M Reference Pressure Gauge, -12 to 300 psi (-80 kPa to 2 MPa)
2700G-BG3.5M Reference Pressure Gauge, -12 to 500 psi (-80 kPa to 3.5 MPa)
2700G-BG7M Reference Pressure Gauge, -12 to 1000 psi (-80 kPa to 7 MPa)
2700G-G20M Reference Pressure Gauge, 0 to 3000 psi (0 to 20 MPa)
2700G-G35M Reference Pressure Gauge, 0 to 5000 psi (0 to 35 MPa)
2700G-G70M Reference Pressure Gauge, 0 to 10 000 psi (0 to 70 MPa)
P5500 Comparison Test Pumps
Designed for testing pressure measuring instruments against master test instruments
P5510: integrated pneumatic hand pump with pressure generation to 300 psi, vacuum to
-12 psi
P5513: pneumatic pressure adjustment to 3,000 psi with fine adjust inlet and outlet valves
and precise screw press
P5514: hydraulic pressure generation and adjustment to 10,000 psi with fine screw press
and reservoir
P5515: integrated hydraulic pressure generation and adjustment to 20,000 psi with high
volume priming pump and fine screw press
Process Calibration Tools
www.fluke.com/processtools
PROCESS CALIBRATION TOOLS
66 www.fluke.com/processtools
3130 Portable Pressure Calibrator
Internal pump can generate vacuum to -12 psi or pressure to 300 psi
Supply pressure connection allowing the use of external gas supply up to 300 psi
Measure or generate 4 to 20 mA
Ordering information
Base model Available ranges
P5510 Gas/Vacuum Comparison Test Pump Generation and control from vacuum to 300 psi (2 MPa)
P5513 High Pressure Gas Comparison Test Pump Ranges to 3000 psi (20 MPa)
P5514 Hydraulic Comparison Test Pump Generation and control to 10 k psi (70 MPa)
P5515 Hydraulic Comparison Test Pump Generation and control to 20 k psi (140 MPa)
3130-G2M Portable Pressure Calibrator -12 to 300 psi (-80 kPa to 2 MPa)
Base model Available ranges
P301X and P302X Deadweight Tester, gas/vacuum, 1 or 2 pistons Ranges from vacuum to 500 psi (3.5 MPa)
P303X Deadweight Tester, liquid lubricated gas, single piston Ranges to 2000 psi (14 MPa)
P31XX Deadweight Tester, oil, 1 or 2 pistons Ranges to 20,000 psi (140 MPa)
P32XX Deadweight Tester, water-operated, 1 or 2 pistons Ranges to 10,000 psi (70 MPa)
P38XX Deadweight Tester, oil, single piston Ranges to 60,000 psi (400 MPa)
P3000 Deadweight Testers
Piston/cylinder design provides stability and repeatability
Built-in pressure generation and control options for vacuum, gas and hydraulic models
Test station design with O-rings eliminates the need for PTFE tape or wrenches
PROCESS CALIBRATION TOOLS
Process Calibration Tools
67
Fluke products designed to intrinsic safety standards
A protection method employed in potentially explosive atmospheres, intrinsically safe devices
are designed to be unable to release sufficient energy, by either thermal or electrical means,
to cause ignition of flammable material (gas or dust/particulates).
Fluke products ATEX certified North American Certification
28 II Ex: Intrinsically
Safe True-rms Multimeter II 2G Ex ia IIC T4 Gb
II 2D Ex ia IIIC T130 °C Db
I M1 Ex ia I Ma
Class I Zone 1 AEx ia IIC T4
Class II Zone 21 AEx iaD T130C
USA and Canada
Class 1 Div 1 Groups ABCD
Class 1 Div 2 Groups ABCD
Class 2 Div 1 Groups EFG
Class III
Ex ia IIC
707Ex: Intrinsically
Safe mA Calibrator II 2 G Ex ia IIC T4
Class I, Div 2, Groups A-D
718Ex: Intrinsically Safe
Pressure Calibrator II 1 G Ex ia IIC T4
I.S. Class I, Div 1, Groups A-D T4
721Ex: Intrinsically Safe
Precision Pressure Calibrator
ATEX: II 2G Ex ia IIB T3 Gb
IECEx II 2 G
725Ex: Intrinsically Safe
Multifunction Calibrator II 1 G Ex ia IIB 171 °C
I.S. Class I, Div 1, Groups B-D, 171 °C
700PEx: Intrinsically
Safe Pressure Modules II 1 G Ex ia IIC T4
I.S. Class I, Div 1, Groups A-D T4
568Ex: Intrinsically Safe
Infrared Thermometer ATEX/IECEx Zone 1 and 2
NEC-500/NEC-505
Class I Division 1 and 2
700G Series Intrinsically Safe
Pressure Gauges II 3 G Ex ia IIB T6
CSA Class I, Div. 2 Groups A-D rating
1551A/1552A: Intrinsically
Safe “Stik” Thermometer ATEX/IECEx Zone 1 and 2
NEC-500/NEC-505
Class I Division 1 and 2
There are no global
intrinsically safe stan-
dards or certifications,
but there are organiza-
tions that influence
directives in certain
world geographies.
Factory Mutual
In the United States,
Factory Mutual
Research, managed by
Factory Mutual (FM)
Global, is a non-profit
scientific and testing
organization that has
tested and certified
over 40,000 products
in the last 165 years.
FM Research has set
certification guidelines
for equipment used in
potentially explosive
atmospheres.
Canadian Standards
Association (CSA)
Accreditation body for
North American regula-
tions, based in Toronto,
Canada.
ATEX
The primary intrinsi-
cally safe standard,
which has been set in
the European Union
with the Directive
2014/34/EU (replac-
ing the 94/9/EC), and
commonly called ATEX
114 (Atmo sphères
Explosibles), French for
explosive atmospheres.
ETL
Accreditation body
for North American
regulations, NEC-500/
NEC-505.
Ordering information
Models
FLUKE-28 II Ex IS True-rms Multimeter
FLUKE-568 Ex Intrinsically Safe Infrared Thermometer
FLUKE-700G Pressure test Gauge, 23 pressure ranges from 0 to 10 inH20 up to 10,000 psi
FLUKE-700PEx Pressure Modules (700P: 01, 05, 06, 09, 24, 27, 29, A4Ex)
FLUKE-707Ex IS Loop Calibrator
FLUKE-718Ex IS Pressure Calibrator
FLUKE-721Ex Precision Pressure Calibrator
FLUKE-725Ex IS Multifuction Process Calibrator
1551A Ex “Stik” Thermometer –50 °C to 160 °C (-58 °F to 320 °F)
1552A ExStik” Thermometer -80 °C to 300 °C ( -112 °F to 572 °F)
Process Calibration Tools
www.fluke.com/intrinsicallysafe
INTRINSICALLY SAFE PRODUCTS
68
120B Series 190 Series II
123B 124B 125B 190-062 190 -102 190-202 190-104 190-204 190-502 190-504
Bandwidth
20 MHz
40 MHz
60 MHz
100 MHz
200 MHz
500 MHz
Input channels
2Ch + 2 DMM
2Ch + DMM
4Ch
Isolated inputs
Triggering
Connect-and-View
IntellaSet Technology
Advanced triggering
Advanced measurement function
Cursors
TrendPlot
ScopeRecord •••••••
100 screen replay
Industrial BusHealth
Harmonics
FFT
Power measurements
Waveform
mathematics
EN61010-1 safety
CAT II 1000 V
CAT III 600 V •••••••
CAT III 1000 V
CAT IV 600 V •••••••
Interface
Optical RS-232
USB PC interface Opt Opt Opt •••••••
Optional WiFi adapter
USB memory port •••••••
Power
Li-Ion •••••••
Battery (hours) 7 7 7 4 (opt 8) 4 (opt 8) 4 (opt 8) 7 7 7 7
General specifications
Size (HxWxD) 259 mm x 132 mm x 55 mm
(10.2 in x 5.2 in x 2.15 in) 270 mm x 190 mm x 70 mm (10.5 in x 7.5 in x 2.8 in)
Weight 1.4 kg (3.2 lb) 2.2 kg (4.8 lb)
Fluke Connect©
Fluke Connect® app
www.fluke.com/scopemeter
ScopeMeter Test Tools
ScopeMeter® Test Tool selection guide
Handheld oscilloscopes for industrial, instrumentation and electronic applications
These handheld battery-powered oscilloscopes are easy to use, with a built-in multimeter, paperless
recording and analysis capabilities. They are rugged and IP51 dust and drip-proof rated to IEC529
standards to withstand harsh environments.
Find how-to videos, application notes and other resources on the scopemeter product pages on www.fluke.com
ScopeMeter® TEST TOOLS
69
ScopeMeter Test Tools
www.fluke.com/scopemeter
Kits—buy more, save more Recommended accessories
SCC120B Accessory Kit
AC120 Alligator
Clip Set
Fluke 120B Series Industrial
ScopeMeter® Test Tools
Three-in-one simplicity
The compact ScopeMeter® 120B Series, is the rugged oscilloscope
solution for industrial electrical and electro-mechanical equip-
ment troubleshooting and maintenance applications. Its a truly
integrated test tool, with oscilloscope, multimeter and high-speed
recorder in one easy-to-use instrument. The ScopeMeter 120B
Series also integrates with Fluke Connect® mobile app and
FlukeView® for ScopeMeter software to enable further collabora-
tion, data analysis and archiving of critical test information.
Dual-input digital oscilloscope and multimeter
40 MHz or 20 MHz oscilloscope bandwidth
Two 5,000-count true-rms digital multimeters
Dual-input waveform and meter reading recorder for trending
data over extended periods
Recorder Event Detect captures elusive intermittent signals on
repetitive waveforms up to 4 kHz
Connect-and-View triggering for an instant, stable display
Fluke’s unique Connect-and-View recognizes signal patterns and
automatically and continuously sets up correct triggering. It provides
a stable, reliable and repeatable display of virtually any signal.
IntellaSet™/AutoReading technology displays critical
measurement data
The Auto Readings function with Fluke IntellaSet technology uses
proprietary algorithms to intelligently analyze the measured wave-
form and automatically displays the most appropriate numerical
measurements on screen, so you can get the data you need easier
than ever before. As an example, when the measured waveform is a
line voltage signal, the Vrms and Hz readings are automatically dis-
played, whereas if the measured waveform is a square wave, the Vpeak-peak and Hz readings
are automatically displayed.
Fluke Connect mobile app compatibility
The Fluke Connect® Assets wireless system of software and wireless test tools enables tech-
nicians to reduce maintenance costs and increase uptime with accurate equipment records
and maintenance data that is easy to interpret, and share. Compare and contrast test point
measurement data and trends so you can better understand signal characteristics and changes
over time.
Fluke Connect-and-View
triggering with Auto Reading
function using Fluke
IntellaSet technology gives
you quick access to the data
you need.
Dual input oscilloscope, meter
and paperless recorder.
Instrument CarePlan
ScopeMeter® TEST TOOLS
Ordering information
Models Included accessories
FLUKE-125/B Industrial ScopeMeter®
Hand Held Oscilloscope (40 MHz) Li-Ion battery pack, charger/power adapter, 2 shielded
test leads with ground leads, black test lead, red and
blue hook clips, banana to BNC adapter, and WiFi USB
adapter**
FLUKE-124/B Industrial ScopeMeter® Hand Held
Oscilloscope (40 MHz)
FLUKE-123/B Industrial ScopeMeter® Hand Held
Oscilloscope (20 MHz)
**WiFi USB adapter NOT available in all countries. Check with your local Fluke representative.
70
Kits—buy more, save more Recommended accessories
SCC290 Kit
AS400 Probe
Accessory
Extension Set
BP291 4800 mAh
High Capacity
Battery
HH290 Hanging
Hook
Fluke 190 Series II ScopeMeter® Test Tools
Faster sample rates. More detail. Greater accuracy.
Safety rated for industrial applications, the 190 Series ScopeMeter portable oscilloscopes are
the first high-performance four-channel scopes built for harsh industrial environments and
can go where ordinary scopes can‘t. They combine rugged portability with high performance
to take you all the way from troubleshooting microelectronics to power electronic applications.
For the first time, plant maintenance engineers and technicians can take a high-performance
four-channel scope into the harsh world of industrial electronics. The new Fluke 190 Series II
is the only portable oscilloscope with two or four independent isolated input channels, a CAT III
1000 V/CAT IV 600 V safety rating, and sealed case IP51 dust-proof and drip-proof rated.
60 MHz, 100 MHz, 200 MHz or 500 MHz bandwidth
2 or 4 independent isolated inputs, up to 1000 V
High-speed sampling: Up to 5 GS/sec
Deep memory: 10,000 points per trace waveform capture (scope mode)
CAT III 1000 V/CAT IV 600 V safety rated for high voltage environments
5,000 count multimeter 2 channel models or 999 count volt meter 4 channel models
Li-ion battery and easy-access battery door for extended usage
Automatic capture and replay of 100 screens
ScopeMeter Portable Oscilloscope users know how frustrating it is to see a one-time anomaly
flash by—never to be seen again. With the ScopeMeter 190 Series II, you can look back in
time with a touch of the replay button. The instrument continuously memorizes the last 100
screens, on a first in-first out basis. At any moment you can “freeze” the last 100 screens and
scroll through picture-by-picture or replay as a “live” animation.
ScopeRecord mode for high-resolution waveform recording up to 48 hours
ScopeRecord memory stores up to 30,000 data points per channel, capturing fast intermittents
and glitches as short as 8ns. Stores events like motion profiles, UPS, power supply and motor
start-ups
The Envelope Trigger mode automatically recognizes a power failure and store the waveform
data. With the waveform zoom (up to 100x) you can look at the smallest details.
TrendPlot Paperless Recorder
Find intermittent faults. Any number of factors like bad connections, dust, dirt, corrosion or
broken wiring or connectors, line outages, sags, or starting and stopping of a motor can cause
a machine to stop intermittently. You may not be around when it happens. Plot the minimum
and maximum peak values and average over timeup to 22 days. Plot any combination of
voltages, amps, temperature, frequency and phase for all four inputs, all with time and date
stamp to pinpoint faults.
Use the 27,000 points
memory of ScopeRecord and
zoom in for maximum detail.
Cursors and zoom features of
the Fluke 190 Series II help
you to analyze the captured
TrendPlot.
Ordering information
Models Included accessories
FLUKE-190-502 Color ScopeMeter, 500 MHz, 2 channels plus DMM/Ext. input
Battery charger/mains adapter,
Li-Ion battery pack, voltage probe
sets, test leads, handstrap affixed
to instrument, hangstrap (user
selectable for left- or righthand use),
multi-language users manuals on
CD, FlukeView® demo package (with
restricted functionality), USB interface
cable for PC connectivity
FLUKE-190-504 Color ScopeMeter, 500 MHz, 4 channels
FLUKE-190-204 Color ScopeMeter, 200 MHz, 4 channels
FLUKE-190-104 Color ScopeMeter, 100 MHz, 4 channels
FLUKE-190-202 Color ScopeMeter, 200 MHz, 2 channels plus DMM/Ext.input
FLUKE-190-102 Color ScopeMeter, 100 MHz, 2 channels plus DMM/Ext.input
FLUKE-190-062 Color ScopeMeter, 60 MHz, 2 channels plus DMM/Ext.input
Instrument CarePlan
www.fluke.com/scopemeter
ScopeMeter Test Tools
ScopeMeter® TEST TOOLS
71
Fluke 190-504 ScopeMeter® Test Tool
The worlds fastest handheld oscilloscope
Now with 500 MHz bandwidth, four channels and 5 GS/s sampling speed. The powerful
Fluke 190-504 Scopemeter extends your troubleshooting arsenal, showing you waveform
shape, timing, distortion and disturbance in greater detail than ever before.
Four independent isolated inputs, up to 1000 V
Deep memory: 10,000 points per trace waveform capture
CAT III 1000 V/CAT IV 600 V safety rated for high voltage environments
999 count multimeter
Li-Ion battery and easy-access battery door for extended usage
Isolated USB host port for direct data storage to a USB memory
USB-B-device port for PC connectivity
The 190-504 ScopeMeter will capture and display unknown waveform shapes, amplitudes
and any disturbances. To display at least the fifth harmonic component of a signal, select a
scope with a bandwidth of at least five times the maximum clock rate of the device under test.
The faster the sample interval, the more accurate and detailed the information the scope will
display a signal edge (dV/dt) and peaks of any reflections or transients.
Rise time response accurately captures signals
with fast edges with signs of reflections.
Accurately capture noise, distortion and other
signal characteristics with 500 MHz bandwidth
and 5 GS/sec sampling rate.
Instrument CarePlan
Ordering information
Models Included accessories
FLUKE-190-504 Color
ScopeMeter, 500 MHz,
4 channels
Battery charger/mains adapter, li-ion battery pack, voltage probe sets, 50 Ohm terminator,
test leads, and strap affixed to instrument, hangstrap (user selectable for left- or righthand
use), multilanguage users manuals on CD, FlukeView® demo package (with restricted
functionality), USB interface cable for PC connectivity
Kits—buy more, save more Recommended accessories
190-504S Kit
VPS510 Red, Green,
Blue and Grey
Voltage Probes
TRM50 50 Ohm
Termination
VPS420 100:1
Voltage Probe
ScopeMeter Test Tools
www.fluke.com/scopemeter
ScopeMeter® TEST TOOLS
Expert Series IR Cameras Professional Series IR Cameras
TiX1000 TiX660 TiX640 TiX560 TiX520 TiX500 Ti450 Ti400 Ti300
Detector resolution
1024 x 768,
2048 x 1536
Super Res.
640 x 480,
1280 x 960
Super Res.
640 x 480 320 x 240
Super Resolution mode: 640 x 480 320 x 240 240 x 180
Field of view 32.4° H x
24.7° V 30.9 °H x 23.1 °V 24 °H x 17 °V
Optional lenses
Capture spectacular images close up or from
a distance with: 2 wide angle, 2 telephoto, 3
macro and 1 standard
Capture spectacular images close up or from
a distance with pre-calibrated smart lenses: wide
angle, 2x and 4x telephoto,
25 micron macro
2x and 4x telephoto and wide angle pre-calibrated
smart lenses
Wireless
connectivity1-Fluke Connect® app compatible. Wireless connectivity to PC, iPhone® and iPad® (iOS 4s and later),
Android 4.3 and up, and WiFi to LAN1
Focus system
LaserSharp® Auto Focus,
autofocus, manual focus, and
EverSharp multifocal recording
Autofocus,
manual focus,
and EverSharp
multifocal
recording
MultiSharp Focus, LaserSharp® Auto Focus with built-in laser distance meter
and advanced manual focus
IR-Fusion®
technology/
visible context
IR-Fusion® AutoBlend mode and
Picture-in-Picture, continuous blending IR-Fusion® AutoBlend mode and Picture-in-Picture
Display 5.6 inch color TFT display, 1280 × 800 pixel
resolution, suitable for daylight operation
5.7 inch touchscreen LCD,
640 x 480 pixel resolution
3.5 inch touchscreen LCD,
640 x 480 pixel resolution
Design
Camcorder with handle, tiltable
LCoS color viewnder display,
800 × 600 pixel resolution
Camcorder Ergonomic FlexCam
design with a 240 degree rotating lens Rugged, ergonomic design for one-handed use
Thermal sensitivity
≤ 0.05 °C at 30
°C target temp
(50 mK)
≤ 0.03 °C at 30 °C target temp
(30 mK)
≤ 0.045 °C at
30 °C target
temp (45 mK);
Filter mode
≤ 0.03 °C
(30 mK)
≤ 0.05 °C at 30
°C target temp
(50 mK); Filter
mode
≤ 0.04 °C
(40 mK)
≤ 0.05 °C at 30
°C target temp
(50 mK)
≤ 0.05 °C at 30
°C target temp
(50 mK); Filter
mode
≤ 0.03 °C
(30 mK)
≤ 0.05 °C at 30 °C target temp
(50 mK)
Temperature
measurement
range
-40 °C to +1200 °C
(-4 °F to 2192 °F)
High temperature option–request
at time of order: up to 2000 °C
(3632 °F)
-40 °C to
+120 0 °C
(-4 °F to
2192 °F)
-20 °C to
+1200 °C
(-4 °F to
+2192 °F)
-20 °C to
+850 °C
(-4 °F to
+1562 °F)
-20 °C to
+650 °C
(-4 °F to
+1202 °F)
-20 °C to +1200 °C
(-4 °F to +2192 °F)
-20 °C to
+650 °C
(-4 °F to
+1202 °F )
Frame rate
30 Hz (Sub-
windowing
options
available up to
240 fps)
60 Hz (Subwindowing options
available up to 240 fps) 60 Hz or 9 Hz
Software SmartView® software and Fluke Connect®1
Documentation
features Voice annotation and text annotation IR-PhotoNotes, voice annotation, and text annotation
Video recording Standard and radiometric
Streaming video
(remote display)
Via HDMI; GigE Ethernet available
in SmartView® software Via USB or WiFi hot spot to PC or via HDMI to HDMI compatible screen
Remote control
Yes, through
SmartView®
software or
Fluke Connect®
mobile app
-Yes, through SmartView® software
or Fluke Connect® mobile app -
Alarms High temperature, low temperature, time lapse - auto image capture, and isotherms (within range)
1Within your providers wireless service area; Fluke Connect is not available in all countries.
Infrared camera and visual IR thermometer selection guide
www.fluke.com/infraredcameras
Infrared Cameras and Thermometers
Performance Series IR Cameras Visual IR
Thermometers
TiS75 TiS65/TiS60 TiS55/TiS50 TiS45/TiS40 TiS20 TiS10 VT04/VT04A
Detector resolution 320 x 240 260 x 195 220 x 165 160 x 120 120 x 90 80 x 60 31 x 31
Field of view 35.7 °H x 26.8 °V 28 °H x 28 °V
Optional lenses -
Wireless
connectivity1Fluke Connect® app compatible. Wireless connectivity to PC, iPhone® and iPad® (iOS 4s and later),
Android 4.3 and up, and WiFi to LAN
Focus system Manual focus TiS65 (Manual focus)
TiS60 (Fixed focus)
TiS55 (Manual focus)
TiS50 (Fixed focus)
TiS45 (Manual focus)
TiS40 (Fixed focus) Fixed focus
IR-Fusion®
technology/
visible context
5 presets (0 %, 25 %, 50 %, 75 %, 100 %) 3 presets
(0 %, 50 %, 100 %) -
Infrared heat map
and visual image
blending in 25 %
increments; center
box to outline
the temperature
measurement area
Display 3.5 inch (landscape) 320 x 240 LCD 2.2 inch portrait
standard TFT LCD
Design Rugged, lightweight, ergonomic design for one-handed use Slim, pocket-sized
design
Thermal sensitivity ≤ 0.08 °C at 30 °C target temp (80 mK) ≤ 0.09 °C at 30 °C
target temp (90 mK)
≤ 0.10 °C at 30 °C
target temp
(100 mK)
≤ 0.15 °C at 30 °C
target temp
(150 mK)
250 mK
Temperature
measurement
range
-20 °C to +550 °C (–4 °F to 1022 °F) -20 °C to +450 °C
(–4 °F to 842 °F) -20 °C to +350 °C (–4 °F to 662 °F) -20 °C to +250 °C
(–4 °F to 482 °F)
-10 °C to +250 °C
(+14°F to +482 °F)
Frame rate 30 Hz or 9 Hz TiS65 (30 Hz or 9 Hz)
TiS60 (9 Hz)
TiS55 (30 Hz or 9 Hz)
TiS50 (9 Hz)
TiS45 (30 Hz or 9 Hz)
TiS40 (9 Hz) 9 Hz 8 Hz
Software SmartView® software and Fluke Connect®1SmartView®
software
Documentation
features
IR-PhotoNotes
(3 images), voice annotation
IR-PhotoNotes
(1 image), voice
annotation
Voice annotation -
Video recording Standard and radiometric -
Streaming video
(remote display)
Yes, to SmartView® software on a PC or to
the Fluke Connect® app on a smartphone -
Remote control -
Alarms High temperature, low temperature, time lapse - auto image capture,
and isotherms (within range)
High temperature,
low temperature,
time lapse - auto
image capture
-
High/low
temperature alarms,
time-lapse image
capture, auto-
monitor alarm
1Within your providers wireless service area; Fluke Connect is not available in all countries.
Infrared Cameras and Thermometers
www.fluke.com/infraredcameras
74
Fluke Expert Series:
TiX1000/660/640 and TiX560/520/500
Stunning HD and industrys largest screen
See incredible detail in your target with SuperResolution and up to 3.1 million pixels.
Navigate over, under and around hard-to-reach objects with a full 240 degree rotating
lens. Easily view, annotate, edit and analyze images on the large tablet-like screen. Get
advanced analytics such as streaming IR data and trend analysis.
Easily navigate over, under and around objects with the 240° articulating lens
(TiX560/520/500) or the articulating LCD display (TiX1000/660/640)
MultiSharp™ Focus (TiX560/520/500) and EverSharp multifocal recording
(TiX1000/660/640) give you clear, accurate focus throughout the field of view in one
image, by capturing multiple images from varying focal distances
LaserSharp® Auto Focus gives you the fastest way to precisely focused images by
calculating the distance to your target with a laser distance meter1
Capture spectacular images close up or from a distance with seven optional
lenses including telephoto, wide angle, and macro (TiX1000/660/640) or inter-
changeable smart lenses—2x and 4x telephoto, wide angle, and 25 micron macro
(TiX560/520/500)
Get premium in-field viewing with the 5.7 inch touchscreen LCD, the largest in its
class (TiX560/520/500) or the 5.6 inch articulating display (TiX1000/660/640) along
with a viewfinder that reduces outdoor glare (TiX1000/660)
1Compared to industrial infrared cameras without a user-designated laser-focus feature.
Apparent hot spots in
electrical equipment.
Get tough shots from any
angle with a 240° degree
rotating lens and the only
5.7 inch LCD in its class
(TiX560/520/500).
Ordering information
Models Included accessories
FLK-TiX1000 30Hz Infrared Camera; 1024 x 768 Rechargeable battery (2 for TiX1000 and TiX660; 1 for
TiX640), battery charger and adapter, ac adapter, SD card
reader, FC SD card for Fluke Connect, protective lens cap,
hand strap, neck strap, carrying case, warranty card, safety
instructions, calibration certificate, printed manual in English
and Chinese, multi-lingual manual CD, SmartView® software
FLK-TiX660 60Hz Infrared Camera; 640 x 480
FLK-TiX640 60Hz Infrared Camera; 640 x 480
FLK-TiX560 9Hz or 60Hz Infrared Camera; 320 x 240 AC power supply; battery pack charger (including universal
AC adapters); two rugged lithium ion smart battery pack; USB
cable; HDMI video cable; micro SD card; rugged, hard carrying
case; adjustable neck and hand straps and quick start guide;
Bluetooth headset (where available)
FLK-TiX520 9Hz or 60Hz Infrared Camera; 320 x 240
FLK-TiX500 9Hz or 60Hz Infrared Camera; 320 x 240
Lens compatibility
Models Lenses
TiX1000/660/640 FLK-XLENS/TELE; FLK-XLENS/SUPTELE; FLK-XLENS/WIDE; FLX-XLENS/SUPWIDE;
FLX-XLENS/MACRO1; FLK-XLENS/MACRO2; FLK-XLENS/MACRO3
TiX560/520/500 FLK-LENS/TELE2; FLK-LENS/4XTELE2; FLK-LENS/WIDE2; FLK-LENS/25MAC2
TiX1000/660/640
TiX560/520/500
www.fluke.com/infraredcameras
Infrared Cameras and Thermometers
INFRARED TOOLS
75
Lens compatibility
Models Lenses
Ti450/400/300 FLK-LENS/TELE2; FLK-LENS/4XTELE2; FLK-LENS/WIDE2
Fluke Professional Series: Ti450/400/300
100 % Focused. Every object.
Get clear, accurate focus on objects near and far with MultiSharp focus, or focus with laser
speed and accuracy on your designated target with LaserSharp® Auto Focus. Easily navigate
the menu and view images on a 3.5 inch, 640 x 480 touchscreen.
Get 4x the pixel data with SuperResolution, which captures multiple images and combines
them to create a 640 x 480 image (Ti450)
Inspect high-temperature components, up to 1200 °C (2192 °F)1
Digitally document critical information with your infrared image using IR-PhotoNotes™, voice
annotation, or text annotation
Monitor processes with video recording, live video streaming, remote control1, or auto
capture
1Features vary by model.
Ordering information
Models Included accessories
FLK-Ti450 9Hz or 60Hz Infrared Camera Infrared camera with standard infrared lens; ac power supply and
battery pack charger (including universal ac adapters); two rugged
lithium ion smart battery packs; USB cable; HDMI video cable; 4GB
micro SD card; rugged, hard carrying case; soft transport bag and
adjustable hand strap and quick start guide
FLK-Ti400 9Hz or 60Hz Infrared Camera
FLK-Ti300 9Hz or 60Hz Infrared Camera
Expand the capabilities of your infrared camera
Software for Fluke Infrared Cameras
Analyze images, adjust blending and palette, export to multiple file formats, and create profes-
sional reports with Fluke SmartView® desktop software, downloadable for free from the Fluke
website, or the Fluke Connect® mobile app for your smartphone. The Fluke Connect® app also
enables you to wirelessly sync images directly from your camera to your smartphone, where
you can email images to colleagues and attach them to an asset record or work order.
Lenses and other accessories
Capture images close up or from a distance with optional lenses, available for the Expert and
Professional Series cameras.
All Fluke Professional and Performance Series cameras feature interchangeable batteries.
Expand your powering capabilities with a car charger, extra battery, or charging base.
Infrared Cameras and Thermometers
www.fluke.com/infraredcameras
Built-in laster distance
meter instantly calculates
and displays the distance
to your target.
Save time and instantly
email images from
the field with the
Fluke Connect® app.
INFRARED TOOLS
Go from being completely out of focus to: 100 % in focus with MultiSharp Focus,
available on the Ti450.
100% Focused–Every object. MultiSharp
76
Ordering information
Models Included accessories
FLK-TiS75 30HZ Industrial Commercial Infrared Camera
Universal AC power adapter, lithium ion smart battery
(TiS75, TiS65/60 includes 2 each—other models 1 each),
USB cable, Micro SD card (TiS75, TiS65/60, TiS55/TiS50,
TiS45), hard carrying case (TiS75, TiS65/60, TiS55/50,
TiS45/40), soft transport bag, adjustable hand strap
(TiS75, TiS65/60, TiS55/50, TiS45/40) and quick start
guide. TiS75, TiS65/60 models include a two-bay battery
charger.
FLK-TiS75 9HZ Industrial Commercial Infrared Camera
FLK-TiS65 30HZ Industrial Commercial Infrared Camera
FLK-TiS65 9HZ Industrial Commercial Infrared Camera
FLK-TiS60 9HZ Industrial Commercial Infrared Camera
FLK-TiS55 30HZ Industrial Commercial Infrared Camera
FLK-TiS55 9HZ Industrial Commercial Infrared Camera
FLK-TiS50 9HZ Industrial Commercial Infrared Camera
FLK-TiS45 30HZ Industrial Commercial Infrared Camera
FLK-TiS45 9HZ Industrial Commercial Infrared Camera
FLK-TiS40 9HZ Industrial Commercial Infrared Camera
FLK-TiS20 9HZ Industrial Commercial Infrared Camera
FLK-TiS10 9HZ Industrial Commercial Infrared Camera
Picture-in-Picture.50 % blending, picture-in-picture modeFull infrared.
Inspect industrial
components.
Designed for your
environment.
www.fluke.com/infraredcameras
Infrared Cameras and Thermometers
INFRARED TOOLS
Fluke Performance Series:
TiS75/65/60/55/50/45/40/20/10
Easy-to-use frontline troubleshooting
Easily see potential problems with precisely blended IR and visual images–with a 5MP visual
camera, up to 320 x 240 resolution, and a large 3.5 inch LCD. Get precise focus as close as 15
cm (6 in) with manual focus.
With up to 320 x 240 resolution, you can see more detail in every image, even from a
distancedetail that could indicate a potential issue
Get the context of the visual and infrared details all in one precisely blended or picture-in-
picture image with IR-Fusion® technology1
Reduce the amount of time it takes to get an in focus image with manual or fixed focus
options
Make decisions in real time—wirelessly sync images from your camera, create and email
reports all with your smart phone and the Fluke Connect® App.
Wirelessly connect to other Fluke Connect tools and pull in other measurements types like
electrical and vibration into your thermal image.
Removable 4GB micro SD card
Digitally document critical information with your infrared image using IR-PhotoNotes or
voice annotation3
Monitor battery charge and avoid unexpected loss of power with the smart battery with LED
charge indicator
1IR-Fusion® and picture-in-picture mode execution varies by model
2Within your provider’s wireless service area; Fluke Connect® is not
available in all countries. Subscription to Fluke Connect® Assets is
required in order to use the asset management and work order function
3Varies by model; see page 73 for model specifications
77
Fluke IR Windows enable
you to inspect electrical
equipment without
opening panel doors.
50 % blended heat map.
Ordering information
Models Included accessories
FLK-VT04A Visual IR Thermometer Soft case, micro-SD card, micro-SD conversion adapter to standard, AA batteries
(4), quick reference guide
FLK-VT04 Visual IR Thermometer
Hard case, micro-SD card, micro-SD conversion adapter to standard, lithium-ion
rechargeable battery, micro USB charger/power supply (including worldwide
adapters), quick reference guide
Ordering information
Models Included accessories
CV400 4 in (95 mm) IR Window, Hand Turn Door Latch
Fluke IR Windows are supplied complete, assembled and
ready for installation. In addition to the IR Window, each
carton contains warranty statement and security key if that
option is ordered.
CV401 4 in (95 mm) IR Window, Security Key Door Latch
CV300 3 in (75 mm) IR Window, Hand Turn Door Latch
CV301 3 in (75 mm) IR Window, Security Key Door Latch
CV200 2 in (50 mm) IR Window, Hand Turn Door Latch
FLK-100-CLKT 4 in (100mm) C-Range IR Window, Kwik
Twist Fluke IR Windows are supplied complete, assembled and
ready for installation. In addition to the IR Window, each
carton contains warranty statement
FLK-075-CLKT 3 in (75mm) C-Range IR Window, Kwik
Twist
FLK-050-CLKT 2 in (50mm) C-Range IR Window, Kwik
Twist
Infrared Cameras and Thermometers
www.fluke.com/vtir
VISUAL IR THERMOMETERS
Fluke VT04/VT04A Visual IR Thermometer
Designed to see it all
See issues in context by blending the infrared heat map with a visual image, and get the
detail you need by choosing one of five on-screen blending modes. See aligned images from
as close as 15 cm (6 in) in near mode or from a distance in far mode. Plus, obtain accurate
temperature readings without taking your eyes off the screen. The center measurement box
shows the exact area of temperature measurement. Fill that center box with your target and
rest assured you're not measuring the background.
Identify intermittent problems by monitoring equipment over time or get alerts when a tem-
perature is outside the expected range with temperature alarms and automated monitoring
features
Instantly identify the hottest and coldest spots within the field of view with hot and cold
markers
Handy when you need it; easily fits in your tool bag or pocket
Intuitive enough to use right out of the box
Easily access saved images with the removable SD card
Save in .bmp format when you only want the image, or choose .is2 format so you can
optimize images and create reports with Fluke SmartView® software, available by free
download from Fluke.com
Fluke IR Windows
CV400/401/300/301/200
CLKT100/75/50
Increase the safety and speed of your electrical infrared inspections
A companys greatest investment is not the equipment that's behind the panel door. It's the
electricians, engineers and inspectors who risk their lives every day doing their jobs.
Highest arc blast safety rating available63 kA*
Under 5 minute installation with 1 person; no need to remove panel door
Clearly view equipment both visually and thermally with ClirVu® coating that protects
the optic from the elements
Corrosion and UV resistant for challenging outdoor environmentsIP67 rugged*
* CV Series only
78 www.fluke.com/thermometers
Thermometers
Fluke infrared thermometers:
62 MAX+, 62 MAX, 59 MAX and 572-2
Take measurements from a safe distance
Fluke has built infrared thermometers with the durability and accuracy you need to do your
job, and all within your budget. These IR Thermometers offer precise laser technology for
accurate and repeatable measurements.
Fluke 62 MAX+ highlights:
Three-meter drop tested
12:1 distance to spot ratio
Min/Max/Avg/Dif, Hi and Lo alarms
Dual lasers for superior targeting
Fluke 62 MAX highlights:
Single laser targeting
10:1 distance to spot ratio
Specifications
62 MAX+ 62 MAX 59 M AX+ 59 MAX
Temperature
range
-30 °C to 650 °C
(-22 °F to 1202 °F)
-30 °C to 500 °C
(-22 °F to 932 °F)
-30 °C to 500 °C
(-22 °F to 932 °F)
-30 °C to 350 °C
(-22 °F to 662 °F)
Accuracy
± 1.0 °C or ± 1.0 % of
reading, whichever is
greater -10 °C to 0 °C:
± 2.0 -30 °C to -10 °C:
± 3.0
± 1.5 °C or ± 1.5 % of
reading, whichever is
greater
-10 °C to 0 °C: ± 2.0
-30 °C to -10 °C: ± 3.0
0° C: ± 1.5 °C or
± 1.5 % of reading,
whichever is greater
≥ 0 °C: ± 2.0 °C or
± 2.0 % of reading,
whichever is greater
Emissivity 0.10 to 1.00 0.10 to 1.00
Power AA battery
Compliance EN/IEC 61010-1: 2001
Laser safety FDA and EN 60825-1 Class II
Fluke 50 Series II Thermometers
Fluke 572-2 Thermometer
Extremely wide measurement range from -30 °C to 900 °C (-22 °F to 1652 °F)
60:1 distance to spot ratio with dual laser sighting
Fluke 59 MAX highlights:
8:1 distance to spot ratio
Min/Max/Avg/Dif, Hi and Lo alarms
Fluke 59 Max+ highlights:
10:1 distance to spot ratio
Min/Max/Avg/Dif, Hi/Lo alarms
Ordering information
Models Included accessories
FLUKE-62 MAX+ Infrared Thermometer, Dual Lasers
Instruction sheet, batteryFLUKE-62 MAX Infrared Thermometer, Single Laser
FLUKE-59 MAX Infrared Thermometer
FLUKE 572-2 High Temperature Infrared Thermometer K-type thermocouple bead probe, durable hard
case, USB 2.0 computer interface cable
FLUKE-54-2-B Datalogging Thermometer, Dual Input Bead thermocouple(s), batteries, overview manual,
instructional guide on CD
FLUKE-53-2-B Datalogging Thermometer, Single Input Bead thermocouple(s), batteries, overview manual,
instructional guide on CD
FLUKE-52-2 Digital Thermometer, Dual Input
FLUKE-51-2 Digital Thermometer, Single Input
VISUAL IR THERMOMETERS
Lab accuracy in a field thermometer
Laboratory accuracy: ± (0.05 % + 0.3 °C)
Large backlit dual display, in °C, °F, or
Kelvin (K)
Min/Max/Avg
Supports a wide range of thermocouple
types
Powerful data logging capabilities
The Fluke 53 II B and 54 II B can log up to
500 points of data to internal memory.
User-adjustable recording intervals
Real-time clock captures the exact event
time
Download data to optional FlukeView®
PC software
79
Thermometers
www.fluke.com/thermometers
Fluke 560 Series Infrared Thermometers
Stand up to tough industrial, electrical, HVAC, and mechanical environments
With a straight-forward user interface and soft-key menus, the Fluke 560 Series IR
Thermometers make even complex measurements easy. With just a few pushes of a button you
can easily adjust emissivity, record data, or turn on and off alarms.
Measure up to 800 °C (1470 °F)
Easily access advanced features with the soft-key buttons and graphical display
Scan large areas or small objects; measure smaller objects from further away
Compatibility with most type K thermocouples
Confidently measure more surfaces, with adjustable emissivity and built-in materials table
Log and download measurements for reporting (568)
Audible and visual alarms alert you to measurements outside of set limits
Pipe probe for superheat and sub-cooling; other contact and ambient measurements (561)
Min/Max/Avg/Dif functions
Includes KTC bead probe
1 % measurement accuracy
Specifications
Fluke 561 Fluke 566 Fluke 568
Infrared temperature
range
-40 °C to 535 °C
(-40 °F to 995 °F)
-40 °C to 650 °C
(-40 °F to 1202 °F)
-40 °C to 800 °C
(-40 °F to 1472 °F)
Accuracy Greater of ± 1 % or ± 1 °C (2 °F)
Distance to Spot (D:S) 12:1 30:1 50:1
Sighting Laser point
Typical distance to target Up to 2.5 m (7 ft) Up to 4.5 m (15 ft) Up to 7.5 m (25 ft)
Probe type Thermocouple K
Contact temperature
range
-40 °C to 550 °C
(-40 °F to 1022 °F)
-270 °C to 1372 °C
(-454 °F to 2501 °F)
Number of on-board
memory locations 20 99
PC download and
software Yes,
with FlukeView® Forms
Soft-key feature menu
navigation
Min/Max/Avg/Dif Min/Max/Dif Min/Max/Avg/Dif
Material type adjustment
(emissivity) Hi/Med/Lo Material table or 0.1 to 1.00 by 0.01
High and low alarms High and low alarms
Hands-free logging
Battery 2 AA
Warranty Two-year
Ordering information
Models Included accessories
FLUKE-568 Infrared Thermometer USB cable, FlukeView® Forms software, thermocouple type K bead probe,
carrying case, two AA batteries, users manual, quickstart guide
FLUKE-566 Infrared Thermometer Thermocouple type K bead probe, carrying case, two AA batteries, users
manual and quickstart guide
FLUKE-561 Infrared Thermometer Thermocouple type K pipe probe, carrying case, two AA batteries, users
manual
FLUKE-61 Infrared Thermometer 9 V battery, instruction sheet
FLUKE-63 Infrared Thermometer Wrist strap, carrying case, 9 V battery, users manual
The 568 allows for
temperature measurement
of small components.
VISUAL IR THERMOMETERS
80 www.uke.com/830
Alignment
Fluke 830 Laser Shaft Alignment Tool
The ideal test tool to precision-align rotating shafts in your facility
The Fluke 830 Laser Shaft Alignment tool is easy-to-use, giving you fast, accurate and
actionable answers that will keep your plant up and running. When it comes to laser shaft
alignment, data is good but answers are better.
Unlike using the straightedge method or dial indicators, the Fluke 830 performs the complicated
alignment calculations for you, meaning you’ll have the answers you need to quickly align your
machine and get your plant up and running fast. An enhanced user interface provides easy to
understand results that don’t require extensive alignment knowledge, and the unique All-in-
One” result screen shows you both coupling results and feet corrections (vertical and horizontal)
in real terms making it easy to take corrective action.
Single laser measurement technology means reduced errors from backlash resulting in
better data accuracy
Intuitive guided user interface quickly and easily complete machine alignments
Compass measurement mode enables flexible, reliable and repeatable measurements using
an active electronic inclinometer
Dynamic machine tolerance check provides continuous evaluation of alignment adjustments
so you know when your machine is in the acceptable range
Unique extend mode handles gross misalignment by virtually increasing laser detector size
Data protection ensures your data is there when you need it with auto save and resume
capability
Specifications
Computer
CPU Intel XScale PXA270 running at 312 MHz
Memory 64 MB RAM, 64 MB flash
Display TFT, transmissive (sunlight-readable), 65,535 colors, backlit LED
Resolution: 320 x 240 pixel; Dimensions: 89 mm (3.5 in) diagonal
LED indicators Multicolor LED for laser status, alignment condition and battery status
Power supply Integrated lithium-ion polymer rechargeable battery: 7.4 V/2.6 Ah
External interface USB host and USB device (slave), integrated wireless communication, Class 1,
transmitting power 100 mW, RS-232 (serial) for sensor, AC adapter/charger socket
Environmental protection IP65 (dustproof, water spray resistant), shockproof, relative humidity 10 % to 90 %
Sensor
Measurement principle Coaxial, reflected laser beam
Laser
Type: Ga-Al-As semiconductor laser
Wavelength (typical) 675 nm (red, visible)
Safety class: Class 2, FDA 21 CFR 1000 and 1040
Beam power: < 1 mW
Detector Measurement area: unlimited, dynamically extendible (U.S. Patent 6,040,903)
Resolution: 1 μm; Accuracy (avg): > 98 %
Inclinometer Measurement range: 0° to 360°; Resolution: <
Environmental protection IP67 (submersible, dustproof)
Prism
Type 90° roof prism; Accuracy (avg): > 99 %
Environmental protection IP67 (submersible, dustproof)
Ordering information
Models Included accessories
FLUKE-830 Laser Shaft
Alignment Tool
Laser sensor, laser prism, chain-type mounting bracket with 150 mm support posts 2x,
300 mm support post 4x, micro fiber cleaning cloth, sensor cable, PC cable, USB drive,
USB drive cable, tape measure, wireless Bluetooth® module, power adapter, instruction
kit, and carrying case
Rotate the shaft and receive
instant measurement
verification.
ALIGNMENT TOOLS
81
Stroboscope
www.uke.com/820-2
Fluke 820-2 LED Stroboscope
Ideal for stop motion diagnostics and frontline mechanical troubleshooting
The Fluke 820-2 LED Stroboscope lets you confidently investigate and observe potential
mechanism failure on a variety of machinery, in a wide range of industries, without making
physical contact with the machine, or shutting the machine down. The Fluke 820-2 is rugged,
compact and easy-to-use making it the ideal portable strobe for stop motion diagnostics,
mechanical troubleshooting and process or product research. Use stop motion diagnostics to
identify the running speed of rotating equipment, identify part numbers or other markings,
measure the speed of rotation or frequency of a rotating shaft, speaker, or mechanical part,
troubleshoot belt drive machines and much more!
High intensity 7-LED array—4,800 Lux @ 6,000 FPM/30 cm
High efficiency LED solid-state light source with uniform flash characteristics allow for
higher flash rates—30 FPM to 300,000 FPM (flashes per minute)
Digital pulse width modulation for exceptionally sharp images at high speeds
Rugged, durable design utilizes solid-state LEDs with no filaments, gases, hollow cavities, or
glass—(one meter drop)
Quartz-accuracy control system provides high accuracy—0.02 % (± 1 digit)
Multi-line LCD display
Check the rotating speed of machinery without physical contact or need for reflective tape
Advance or retard flash timing for viewing gear teeth, cutting surfaces, repeats, or “drifting
equipment
Simple push button operation with 2x and ÷2 buttons for easy adjustment
Specifications
Flash frequency
Range 30 to 300,000 FPM
0.5 to 5000 Hz
Accuracy 0.02 %
Resolution
30 to 999 FPM = 0.1
1000 to 300,000 = 1
0.5 Hz to 999 Hz = 0.1
1000 Hz to 5000 Hz = 1
Frequency setting FPM or Hz
External trigger
Method Connector to externally control trigger
High level 3 V to 32 V
Low level < 1 V
Minimum pulse width 50 μs connection
Safety compliance
Agency approvals CE
Class III (SELV) Pollution Degree 2
Impact resistance 1 m drop
Mechanical specifications
Size (HxWxL) 5.71 cm x 6.09 cm x 19.05 cm
(2.25 in x 2.4 in x 7.5 in)
Weight 0.24 kg (0.53 lb)
Ordering information
Models Included accessories
FLUKE-820 LED
Stroboscope Protective case and external trigger connector
Identify running speeds
using stop motion
diagnostics.
STROBOSCOPES
82 www.fluke.com/vibration
Vibration
Fluke 810 Vibration Tester
Get mechanical maintenance answers now!
The Fluke 810 Vibration Tester is the most advanced diagnostic tool for mechanical
maintenance teams who need to keep machines up and running. The Fluke 810 is
engineered to provide machine condition answers and evaluate the most common
mechanical problems.
The Fluke 810 Vibration Tester uses a simple 3-step process to report on machine faults
the first time measurements are taken, without prior machine history. To locate and
diagnose common mechanical problems and prioritize repair actions, use these three
simple steps: set-up with basic machine information; measure to quickly troubleshoot
problems or monitor machine condition; and diagnose and identify the root cause, loca-
tion and severity.
Use the Fluke 810 to:
Easily determine the root cause, location and severity of common mechanical faults
Efficiently prioritize and plan equipment repair or replacement
Effectively deploy maintenance resources at the point of greatest impact
Viewer PC
Software
Store and track
your data
Generate diag-
nostic reports and
track the severity
of your machine’s
condition
Import and store
JPEG images
Specifications
Diagnostic specifications
Analysis for
Motors, fans, blowers, belts and chain drives, gearboxes, couplings, centrifugal
pumps, piston pumps, sliding vane pumps, propeller pumps, screw pumps, rotary
thread/gear/lobe pumps, piston compressors, centrifugal compressors, screw
compressors, closed coupled machines, spindles
Standard faults Unbalance, looseness, misalignment and bearing failures
Motor rotational speed range 200 rpm to 12000 rpm
Diagnosis details Plain-text diagnosis, fault severity (slight, moderate, serious, extreme), repair
details, cited peaks, spectra
Tester specifications
IP rating IP54
A/D converter 4 channel, 24 bit
Dynamic range 128 dB
FFT resolution 800 lines
Battery Lithium-ion, rechargeable, 8 hours operating life
Onboard storage capacity 2 GB internal + user accessible slot for additional storage
Warranty Three-year (tester), One-year (sensor and tachometer)
Sensor specifications
Sensor type Tri-axial accelerometer , 100 mV/g (± 5 %, 25 °C)
Tachometer specifications
Tachometer type Laser Diode Class 2
Instrument CarePlan
Ordering information
Models Included accessories
FLUKE-810 Vibration Tester
Tri-axial accelerometer, magnet mount, mounting pad kit with adhesive, quick-
disconnect accelerometer cable, laser tachometer with storage pouch, battery pack with
cable and adapters, shoulder strap, adjustable hand strap, Viewer PC software, mini USB
to USB cable, carrying case, training DVD, getting started guide, quick reference guide,
and users manual on DVD
VIBRATION TOOLS
1. Setup 2. Measure 3. Diagnose
83
Vibration
www.fluke.com/vibration
Fluke 805 FC Vibration Meter
Forget the pens. Think METER.
The Fluke 805 FC Vibration Meter is the most reliable vibration screening device available for
frontline mechanical troubleshooting teams who need repeatable, severity-scaled readings of
overall vibration and bearing condition.
5 tools in 1: Overall vibration, bearing impacting,
temperature, machine health severity, and
bearing health severity
Get authorization to take next steps in an instant
if machine health is at risk via Fluke Connect®
Four-level severity scale assesses urgency of
vibration problems
Vibration measurement for acceleration, velocity,
and displacement units of measurement
Colored lighting system (green, red) and on-
screen comments indicate how much pressure
needs to be applied to take measurements
Non-contact temperature measurement increases
machine health screening capabilities
External accelerometer support for hard to reach locations
Specifications
Vibration meter
Low frequency range (overall measurement) 10 Hz to 1,000 Hz
High frequency range (CF+ measurement) 4,000 Hz to 20,000 Hz
Severity levels Good, Satisfactory, Unsatisfactory, Unacceptable
Vibration limit 50 g peak (100 g peak-peak)
A/D converter 16-bit
Sampling rate Low frequency: 20,000 Hz; high frequency: 80,000 Hz
Sensor
Sensitivity 100 mV/g ± 10 %
Measurement range 0.01 g to 50 g
Low frequency range (overall measurement) 10 Hz to 1,000 Hz
High frequency range (CF+ measurement) 4,000 Hz to 20,000 Hz
Resolution 0.01 g
Accuracy At 100 Hz ± 5 % of measured value
Amplitude units
Acceleration g, m/sec2
Velocity in/sec, mm/sec
Displacement mils, mm
Infrared thermometer (temperature measurement)
Range -20 °C to 200 °C (-4 °F to 392 °F)
Accuracy ± 2 °C (4 °F)
Focal length Fixed, at ~3.8 cm (1.5 in)
Environmental
IP rating IP54
Drop test 1 meter
What is Crest
Factor+?
Crest Factor (CF)
is used to identify
bearing faults and is
the ratio of the peak
value/RMS value of a
time domain vibration
signal. As the bearing
condition worsens, the
CF+ value increases.
Fluke has also
included a four-level
severity scale that
identifies the bearing
health.
More than an overall
vibration meter
5 tools in 1
1. Low frequency
vibration meter
2. High frequency
vibration meter
(bearings)
3. IR temperature
meter
4. Machine health
screening tool (37
machine categories)
5. Bearing health
screening tool
Ordering information
Models Includes
FLUKE-805 FC Vibration Meter USB cable, storage case, belt holster, quick reference guide, (includes MS Excel
template and documentation), and two AA batteries
FLUKE-805ES External Sensor External vibration sensor with threaded mounting bolt, removable “U” shaped
magnet mount, and 2.1336 m (7 ft) coiled cable
VIBRATION TOOLS
www.fluke.com/accessory
84 Accessories
Fluke cases and holsters
A premium meter deserves a premium case
C23 Soft Carrying Case
Case with inside
pocket and belt loop
Dimensions
(HxWxD): 22.5 x
9.5 x 5.8 cm (8.9 x
3.75 x 2.3 in)
C280 Soft Case
Made of durable
polyester 600D
Dimensions
(HxWxD): 23 x 18.5
x 6.5 cm (9 x 7.3 x
2.6 in)
C115 Soft Carrying
Case
Made of durable
polyester 600D
Dimensions
(HxWxD): 24 x
20.5 x 7.5 cm
(9.5 x 8 x 3 in)
C116 Soft
Carrying Case
Made of durable
polyester 600D
Dimensions
(HxWxD): 24 x
23 x 6.5 cm (9.5
x 9 x 2.6 in)
C150 Soft
Carrying Case
High quality
1000D fabric
Dimensions
(HxWxD): 29.8
x 11.4 x 5.6 cm
(11.75 x 4.5 x
2.2 in)
C781 Meter
Case
Made of
durable polyester
600D
Dimensions
(HxWxD): 26.9
x 14.1 x 9 cm
(10.6 x 5.6 x
3.5 in)
C33 Soft
Carrying Case
Case with inside
pocket and belt
loop
Dimensions
(HxWxD): 28 x
11.5 x 5.5 cm
(11 x 4.5 x 2.2 in)
Soft cases
CAMO-C25
Camouflage
Carrying Case
High quality 1000D
fabric
Dimensions
(HxWxD): 20.3 x 12.1
x 4.6 cm (8 x 4.8 x
1.8 in)
CAMO-C37
Camouflage Carrying
Case
High quality 1000D
fabric
Dimensions
(HxWxD): 26.5 x 9
x 3 cm (10.5 x 3.5 x
1.2 in)
C75 Accessory
Case
Zippered carrying
case
Dimensions
(HxWxD): 17.9 x
10.3 x 2.6 cm
(7 x 4 x 1 in)
C50 Meter Case
Case with inside
pocket, belt loop and
inside meter strap
Dimensions (HxWxD):
19.2 x 9 x 3.8 cm
(7.56 x 3.5 x 1.5 in)
C25 Large Soft Case
for DMMs
Case with padding
and inside pocket
Dimensions (HxWxD):
21.8 x 12.8 x 6.4 cm
(8.6 x 5 x 2.52 in)
C90 Soft Case for
DMMs
Case with inside
pocket and belt
loop
Dimensions
(HxWxD): 20.5 x 9
x 7.2 cm (8 x 3.5 x
2.8 in)
C35 Soft
Carrying Case
Made of durable
polyester 600D
Dimensions (HxWxD):
22 x 14 x 6.5 cm
(8.7 x 5.5 x 2.6 in)
C789 Meter and
Accessory Case
Made of durable
polyester 600D
Dimensions
(HxWxD): 30.8 x
25.6 x 7.7 cm (12
x 10 x 3 in)
C43 Soft
Carrying Case
Made of durable
polyester 600D
Dimensions
(HxWxD): 31.8 x
23 x 9 cm (12.5 x
9.1 x 3.5 in)
C550 Tool Bag
Made of bal-
listic cloth with
heavy-duty
hardware
Dimensions
(HxWxD): 33.3
x 51.3 x 23.1
cm (13 x 20.2 x
9.1 in)
C345 Soft Case
Made of durable
polyester 600D
Dimensions
(HxWxD): 36 x 20 x
24 cm (14 x 8 x
9.5 in)
www.fluke.com/accessory 85
Accessories
Fluke cases and holsters
A premium meter deserves a premium case
Hard cases
CXT Series
Extreme Cases
Models CXT80,
CXT170, and
CXT280 for
various meter
compatibility
Unbreakable,
watertight,
airtight, chem-
ical resistant
and corrosion
proof
C101 Hard Case
Dimensions
(HxWxD): 30.5
x 36 x 10.5 cm
(12 x 14.2 x
4.1 in)
C100 Universal
Carrying Case
Dimensions
(HxWxD): 39.7 x
34.6 x 12.2 cm
(15.7 x 13.6 x
4.8 in)
C1600 Gear Box
Includes five hook
and loop straps
to wrap cords
and test leads
Dimensions
(HxWxD): 26 x
39 x 20 cm
(10 x 15 x
7.8 in)
CXT1000
Extreme Hard
Case - New
Rugged hard
case that allows
you to configure
the diced foam
interior and
offers maximum
protection
Waterproof to a
depth of 3 feet,
airtight, and
O-ring sealed
for automatic pressure
equalization
Dimensions (HxWxD):
34.3 x 46.5 x 17.8 cm
(13.5 x 18.3 x 7 in)
Leather cases
C520A Leather
Tester Case
Dimensions
(HxWxD): 25.6
x 15.4 x 10.6
cm (10 x 6 x
4 in)
C510 Leather
Meter Case
Dimensions
(HxWxD): 28.7 x
17.9 x 10.6 cm
(11 x 7 x 4 in)
Holsters
H15 Electrical
Tester Holster
High quality
1000D fabric
Dimensions
(HxWxD): 27.9 x
9.2 x 5.1 cm (11 x
3.6 x 2 in)
H80M Protective
Holster
Includes a
hanging
magnet, gen-
eral purpose
hanger, and
hook and
loop straps
Dimensions
(HxWxD): 19 x 9.5 x
4.3 cm (7.5 x 3.7 x 1.7 in)
H5 Electrical
Tester Holster
Dimensions
(HxWxD): 19.2 x
9 x 3.8 cm (7.5
x 3.5 x 1.5 in)
H3 Clamp Meter
Holster
Dimensions
(HxWxD): 23.1 x
9 x 6.4 cm (9 x
3.5 x 2.5 in)
H6 IR
Thermometer
Holster
Dimensions
(HxWxD): 30.2 x
17.8 x 5.7 cm
(11.9 x 7 x 2 in)
www.fluke.com/accessory
86 Accessories
Fluke cases and holsters
A premium meter deserves a premium case
Cases and holsters selection guide
113/114/115 /116/117
27 II/28 II
77- 4/175/177/179
83V/87V
233
287/289
8845A/8846A/8808A
120/190/22X Series
51-II/52-II/53-II B/54-II B
561/566/568
63/66/68
323/324/325
355
365/373/902
374 FC/375FC /376 FC/
381
705/707
712/714/715/717/72X
Series
718/719
753/754
787/789
T+/T+PRO
T5-600/T5-1000
1503/1507/1577/1587 FC
C12A
C23
Camo-C25
C25
C33
C35
Camo-C37 365
C43
C50
C75 The C75 is designed to hold test leads, probes, clips and other required accessories
C90
C100 71X 787
C101
C115/ C116 365
C125 83V
C150
C280
C345 The perfect case for carrying a wide range of Fluke handheld test tools and accessories
C510 787
C520A
C550/C1600 The C550 and C1600 are large enough to hold accessories and multiple test tools
C781 72X 789
C789 365
C799
C800 71X 787
CXT80 72X
CXT170 71X
CXT280
CXT1000 The CXT1000 is designed to store, carry, and protect a wide range of Fluke test tools and accessories
H15
www.fluke.com/accessory 87
Accessories
TLK289 Industrial Master Test Lead Set
and Case
Designed for electrical and electronics test
in today’s industrial environment.
SureGrip alligator clips, grabbers and
hook clips for dependable contact with a
variety of test points
TP175 Twi stGuard Test Probes
Magnetic hanger for suspension of your
DMM
Temperature adapter with type K
thermocouple for direct temperature
measurement with your DMMs
TLK-225 SureGrip Master
Accessory Kit
TP175 Twi stGuard Test Probes
Plunger style alligator clips
Plunger style hook clips
Plunger style pincer clips
Large jaw alligator clips
Right to straight test leads
Six-pocket storage pouch, keeps the
entire set together
Fluke accessory sets and kits
Get an outstanding value with our most popular accessories
T5-Kit, Tester Starter Kit
Getting started kit for electricians who
already own a Fluke T5 Tester.
Test probes
Large jaw alligator clips
Zippered soft case
TL220 Industrial Test Lead Set
Starter kit for industrial applications
Includes 1 pair: AC220, TP220, TL224
CAT II 1000 V, 10 A (TP220 only)
CAT III 1000 V, CAT IV 600 V with
protective cap
TL223 Electrical Test Lead Set
Starter kit for electrical applications
TP1 has flat blades for wall sockets
Includes 1 pair: AC220, TP1, TL224
CAT II 1000 V, 10 A (TP1 only)
CAT III 1000 V, CAT IV 600 V with
protective cap
TLK287 Electronics Master Test
Lead Set
The perfect test lead kit for today’s elec-
tronics test and design.
Precision electronic probes with multiple
spring-loaded sharp tips to maximize
contact with SMD test points
Micro-grabbers and leads to enable fine
SMD test
Modular mini-alligator clips, grabbers,
leads, probes, and couplers for virtually
every electronics need
Test lead kits selection guide
113/114/115/116/117
27 II/28 II/27
77 IV
175/177/179
83V/87V/233
287/289
434/435
8845A/8846A/8808A
120 Series
190 Series
225C
323/324/325
355
365/373
374 FC/375 FC/376 FC/
381
902 FC
705/707
71X Series
724/725/726
753/754
787/789
T+/T+Pro
T5-600/T5-1000
1503/1507/1577/1587 FC
TLK287 ••••••••••••• •••••
TLK289 116
TL220 •••••••••••••• •••••
TL223
TL225 ••••••••••••• •••••
TL238 ••••••••••••• •••••
TL80A ••••••••••••• •••••
TL81A ••••••••••••• •••••
80K-8, 80K-15,
80K-40
dc
only
TLK-220 SureGrip Accessory Kit
with Meter Carrying Case
Plunger style alligator clips
Large jaw alligator clips
Sharp test probes
Right to straight test leads
Zippered vinyl carry case with
moveable divider
Holds large DMMs
www.fluke.com/accessory
88 Accessories
Fluke test leads, probes and clips
The best leads for all your measurement needs
For electronic applications For automotive applications
TL80A Basic Electronic Test Lead Set
Six piece set with zippered case
Probes, alligator clips and tip extenders
for electronic applications
CAT II 300 V
CAT III 1000 V, CAT IV 600 V with
protective cap
TL910 Electronic Test Probes with
Replacement Tips
Small profile pro-
vides accessibility
Comes with five
sets of replaceable
tips
Replacement tips:
TP912
CAT II 1000 V, 3 A
TP80 Electronic Test
Probes
Tapered tip ideal for
probing electronic com-
ponents or boards
Removable guard for IC
probing
CAT III 1000 V, 10 A
TP920 Test Probe
Adapter Kit
IC test tip adapt-
ers, extended tips,
medium alligator clips
fit over TL71 and
TL75 test lead sets
IC test tip Adapter, 3 A
Extended probe tip, 3 A
Med. alligator clip, 5 A
CAT II 300 V
TL40 Retractable Probe
Assembly
Retractable, insulated
sharp probe tip
CAT II 600 V, 3 A
TL26A Telecom Test
Lead Set
Five-way multipoint
test clips for telecom-
munications applications
Flexible silicone insulated
leads are heat and cold resistant
Rated 30 V, 8 A
TP81 and TP82
Stainless steel probe
pierces insulation
on 0.75 mm² to
2.00 mm² wire
Design provides complete
insulation while working on fuel
injectors or sensors
TP81 for use with modular test leads
(Fluke TL224)
TP82 slips over probe tips (Fluke TL71)
Rated to 60 V dc
TP88 Rigid
Backprobe Pin Set
51 mm (2 inch)
long pins pass
between the
weather pack seal and wire
Use with Fluke TL71 or TL75 test
lead sets
Rated to 60 V dc
TLK281 Automotive Test Lead Kit
Insulation piercing probes
SureGrip silicone test leads
SureGrip test probes
SureGrip plunger style alligator clips
SureGrip alligator clips
Carrying case
TLK282 Deluxe Automotive Test Lead Kit
Insulation piercing probes
Set of five automotive back probe pins
SureGrip silicone test leads
SureGrip test probes
SureGrip plunger style alligator clips
SureGrip alligator clips
SureGrip hook clips
Carrying case
80K-6, 80K-15, 80K-40 High Voltage Probes
Allows a digital multimeter to measure up
to 6,000 volts peak, 15,000 volts peak and
40,000 volts peak respectively
1000:1 division ratio output when connected
to 10 MΩ multimeter
Ground clip included
Intended for low energy applications that are
referenced to ground
80K-15 (not available in Europe)
Note: intended for low energy applications only
High-voltage probes
TP40 Automotive
Back Probe Pin Set
Set of five 38 mm
(1.5 inch) pins
Rated to 60 V dc
Provide an easy
connection past
weather pack seals to
connector conductors
Use with Fluke TL71 or TL75 test
lead sets
TL82 Automotive
Pin & Socket
Adapter Set
Collection of male
and female
adapters allows
you to make firm
connection to pin
and socket connectors
Adapters with flexible tips come
in the following sizes: 0.3 mm² to
3.3 m
Rated to 60 V dc
www.fluke.com/accessory 89
Accessories
TP175, TwistGuard Test Probes
Converts probe tip length between
4 mm, a CAT III 1000 V, CAT IV
600 V measurement and
19 mm, a CAT II 1000 V
measurement
Fits standard modular
test leads
FTPL-1 SureGrip Fused Test
Probes with Leads
FTP-1 Fused Test Probes
with built-in fuses for
added protection
TL224 Silicone Insu-
lated Test Leads
CAT III 1000 V, CAT IV
600 V, 10 A
TL221 SureGrip
Silicone Test Lead
Extension Kit
Superior strain relief
Includes two adapters
to extend leads 1.5 m
CAT III 1000 V,
CAT IV 600 V, 10 A
TL222 SureGrip
Silicone Insulated
Test Leads
Superior strain relief
Recommended for use
with AC220, AC280,
AC283 test clips
CAT III 1000 V,
CAT IV 600 V, 10 A
AC175 Threaded Alligator Clips
Threads securely onto
TL175 or TP175 probes
Insulated alligator clips
with flexible boots
Jaw opening: 7 mm
(0.275 in), jaw contact
material: nickel-plated steel
CAT III 1000 V, CAT IV 600 V
AC173 Extended Tooth Alligator Clips
Extended tooth jaw with
front placement for
attaching to screw heads
Accepts standard 4 mm
modular test leads
Jaw opening: 8 mm (0.31 in), jaw contact
material: nickel-plated steel
CAT III 1000 V, CAT IV 600 V
Fluke SureGrip accessories
As tough as your meter
Modular test leads and test probes (use test probes with test leads) The new standard for safety
Modular clips (use with test leads,
includes one red, one black)
TL71 Premium DMM Test Lead Set
Flexible silicone
insulated leads
are heat and cold
resistant
Distinctive comfort
grip probes
Recommended for
µV measurements
CAT II 1000 V, 10 A
CAT III 1000 V, CAT IV 600 V with
protective cap
TL75 Hard Point Test Lead Set
Extremely hard alloy tips
resist wear
Distinctive comfort
grip probes
1.5 m PVC leads
CAT II 1000 V, 10 A
CAT III 1000 V,
CAT IV 600 V with protective cap
AC220 SureGrip Alligator Clips
Insulated, nickel plated jaws grip
objects up to 10 mm (.375 in)
Blunt tip grabs round screw heads
CAT III 1000 V, CAT IV 600 V, 10 A
AC280 SureGrip Hook Clips
Profile narrows to 5.5 mm
(.22 inch) at tip
Hook opening 5 mm (.20 inch)
at front, 2 mm (.08 inch) at base
CAT III 1000 V, CAT IV 600 V, 3 A
AC283 SureGrip Pincer Clips
11.4 cm (4.5 inch) flexible,
insulated shaft
Nickel plated pincers open
to 5 mm (.20 in)
CAT III 1000 V, CAT IV 600 V, 1 A
AC285 SureGrip Alligator Clips
Multi-purpose tooth pattern
grips anything from fine
gauge wire to a 19 mm
(.75 in) nut
Nickel-plated steel jaws
Accepts standard modular 4 mm test leads
CAT III 1000 V, CAT IV 600 V, 10 A
TL175 TwistGuard™ Test Leads
Probes meet new EN 61010-031
requirements
for safety
Patented
extendable
tip guard meets
new CAT III 1000 V, CAT IV 600 V
requirements while providing the
flexibility you need for CAT II
measurements
New Wear-
Guard test lead
wear indicator
that changes
color when leads
are damaged
and in need of
replacement
Probes always
show correct category rating for tip
being used
Advanced strain relief exceeds
5,000 bend life
TP175 probes fit modular test leads
TL238 SureGrip Test Lead Set for
high energy environments
Insulated tip
probes help
lessen risk
of arc flash
explosion
Probe extenders
keep hands
away from
live current
Includes one pair each,
insulated test tip probes, probe
extenders and TL224 Test Leads
Probes and leads CAT III 1000 V,
CAT IV 600 V, 10 A, extenders
CAT III 1000 V 10 A
TL224 SureGrip Silicone Insulated
Test Leads
Superior strain relief
1.5 m silicone-
insulated wire resists
heat and cold
CAT III 1000 V, CAT IV
600 V, 10 A
FTP-1 SureGrip
Fused Test Probes
Built-in fuses for
added protection
2 mm threaded probe
tips include removable
4 mm lantern-style
spring contacts
Removable GS38 insulated caps
CAT III 1000 V, CAT IV 600 V, 10 A
TP1, TP2, TP4 and TP38
Slim Reach Test Probes
Slender probe bodies for
probing closely spaced or
recessed points
TP1 has a flat blade
TP2 has 2 mm
diameter tip
TP4 has 4 mm
diameter tip
TP38 has stainless steel
insulated probe to help
lessen the risk of arc flash explosion
CAT II 1000 V, 10 A
CAT III 1000 V, CAT IV 600 V with
protective cap (TP1 and TP2 only)
CAT III 1000 V, CAT IV 600 V
(TP38 only)
TP220 SureGrip
Industrial Test Probes
Sharp, 13 mm (.5 inch)
stainless steel tip
provides reliable contact
Flexible finger barrier improves grip
CAT II 1000 V, 10 A
CAT III 1000 V, CAT IV 600 V with
protective cap
www.fluke.com/accessory
90 Accessories
Specifications
Bead Bead HVAC Immersion Surface Air Piercing General
purpose
Industrial
surface
80BK-A 80PK-1
80PJ-1 80PK-11 80PK-22 80PK-3A 80PK-24 80PK-25
80PT-25 80PK-26 80PK-27
Lowest temperature -40 °C
(-40 °F) -30 °C
(-22 °F) -40 °C
(-40 °F) 0 °C
(32 °F) -40 °C
(-40 °F)
K Type: -40 °C
(-40 °F) T Type:
-196 °C (-321 °F)
-40 °C
(-40 °F) -127 °C
(-196 °F)
Highest temperature 260 °C
(500 °F) 105 °C
(221 °F) 1090 °C
(1994 °F) 260 °C
(500 °F) 816 °C
(1500 °F) 350 °C
(662 °F) 816 °C
(1500 °F) 600 °C
(1112 °F)
Probe material Type K wire with
teflon insulation Velcro Inconel 600 Type K sensor
with teflon body Inconel 316 Stainless
Steel 304 Stainless Steel
Probe length 1 m lead wire 19 in Velcro cuff 21.27 cm
(8.375 in) 9.525 cm
(3.75 in) 21.59 cm
(8.5 in) 10.16 cm
(4 in) 21.57 cm
(8.5 in) 20.32 cm
(8 in)
Cable length 1 m (3.3 ft) 1.3 m (4 ft) 1 m (3.3 ft)
Connection Standard
banana jack Molded thermocouple plug
SureGrip handle
Key feature Ideal for initial troubleshooting. Can
be secured in place with a magnet.
Velcro probe
allows hands
free temperature
measurement.
For use in
liquids or in gels.
Exposed junction
for direct contact
with flat or
slightly convex
surfaces.
Perforated baffle
for air and
non-caustic gas
measurements.
Probe material
safe for use in
foods. Sharp tip
pierces solid
surfaces.
Use for general
purpose air
or surface
measurements.
Low conductivity
stainless steel
minimizes ther-
mal shunting.
Extra rugged.
Thermocouple types K K, J K K K, T K
Typical use
General purpose •••••••••
HVAC •••••
Food service
Industrial
Residential
Commercial •••••••••
Fluke temperature accessories
Hot probes with cool designs
The 80TK enables your meter to read temperature using mV.
For the Fluke Thermometer, 51, 52, 53, and 54 III, no adapter is necessary for thermocouple types K, J, T and E.
SureGrip temperature accessories
The innovative SureGrip design from Fluke
is now available in select temperature probes.
The soft rubber handle combined with a new
ergonomic shape is so comfortable to hold
that you’ll forget about the probe and focus on
the measurement. All SureGrip probes have
an improved, more flexible strain relief for a
long life.
Cleans up with
soap and water
Soft rubber
handle provides a
secure grip
Temperature accessories selection guide
113/114/115/116/117
175/177
179
233
3000 FC DMM
287/289
27-II/28-II
8845A/8846A/8808A
77 IV
83 V
87 V/88V
43B
120 Series
190 Series II
1577
1587 FC
51/52/53/54-II
561
566/568/572-2
705/707
714
715
724/725
753/754
787/789
Contact Probes
80PK-1/80PK-27 1122222111211112 11 1
80PJ-1/80PJ-9
80PT-25
DMM Probes
80AK-A 3 5
80BK-A 3 5
80TK 6
80T-150UA •••••••••••••
Miscellaneous
80CK-M 1122222111211112•••11 1
80CJ-M
80PK-EXT (4) 1122222111211112•••11 1
80PJ-EXT
80PT-EXT
80PT-EXT
1-Requires 80TK 2-Requires 80AK 3-Fluke 116 Only 4-Also requires 80CK-M 5-28 II only 6-27 II only
www.fluke.com/accessory 91
Accessories
80TK Thermocouple Module
Converts type K
thermocouple
signals into mV
output
Connects to DMM
via standard
banana plugs
Switch selectable
°C or °F
Range: -50 °C to 1000 °C
(-58 °F to 1832 °F)
Includes 80PK-1 probe
80T-150UA Universal Solid State
Temperature Probe
For measurement
of air, surface and
non-corrosive
materials
Measurement
range:
-50 °C to 150 °C
(-58 °F to 302 °F)
Output: 1 mVC or 1 mV/°F (switch
selectable)
Connects to DMM via standard banana
plugs
80PK-8, 80PK-10, Pipe Clamp
Temperature Probes
Type K thermo-
couples clamp
securely onto pipes
for fast tempera-
ture and superheat
measurements
Durable ribbon
sensors
1 m (39 in) lead
Measure from -29 °C to 149 °C
80PK-8 for 6.4 mm to 34.9 mm
(0.25 in to 1.375 in)
80PK-10 for 32 mm to 64 mm
(1.25 in to 2.5 in)
Fluke temperature accessories
Turn your digital multimeter into a thermometer
BP7240
Li-ion rechargeable
battery; nominal
7.2 volt,
4400 mA hr
Use with 750 Series
Calibrators
BP7235
NiMH rechargeable
battery; nominal
7.2 volt, 3500 mA hr
Use in 700 and 740
Series Calibrators
700LTP-1 Low Pressure Test Pump
Hand operated pressure
pump designed to generate
either vacuum to -13 psi/
-.90 bar or pressures to
100 psi/6.9 bar. Ideal for
low pressure applications
requiring accurate low
pressure testing.
700ILF In-line Filter
The Fluke 700ILF can
be used to isolate
the calibrator from
incidental contact with
fluids. Particularly
useful with the 718 calibrator to help
keep moisture or oils from contami-
nating the on-board pump.
700PTP-1 Pneumatic
Test Pump
The Fluke 700PTP is a hand-
held pressure pump designed
to generate either vacuum to
-11.6 psi/-0.8 bar or pressure
to 600 psi/40 bar.
Thermocouple Plug Kits
700TC1
A kit of ten mini-plug
connectors. One each of
the following:
Type J (black)
Type K (yellow)
Type T (blue)
Type E (purple)
Type R/S (green)
Type B or Cu (white)
Type L (J-DIN) (blue)
Type U (T-DIN) (brown)
Type C (red)
Type N (orange)
700TC2
A kit of seven mini-plug
connectors.
Type J (black), two
Type K (yellow), two
Type E (purple), one
Type T (blue), one
Type R/S (green), one
Other temperature accessories
80PK-18,
Pipe Clamp
Temperature
Probe Kit
Includes both
80PK-8 and
80PK-10
Type K clamps
Provides full range of pipe measurement
sizes
Includes soft carrying case to conve-
niently keep both clamps handy for any
situation
80CK-M and 80CJ-M
Type K and J Male
Mini-Connectors
Isothermal screw ter-
minal for K or J wire
Suitable for up to 20
gauge thermocouple
wire
Color coded to industry
standards (K-yellow,
J-black)
Two per package
80PJ-EXT, 80PK-EXT, 80PT-EXT
Thermocouple Wire
Extension Kits
For extending and
repairing type J, K or
T thermocouple wires.
Kit includes
3 m (9 ft) of thermo-
couple wire and 1
pair of male/female
mini-connectors
Maximum con-
tinuous exposure
temperature: 260 °C
(500 °F)
80PK-EXT is compat-
ible with type K
thermometers; 80PJ-
EXT is designed for
type J thermometers,
and 80PT-EXT is
designed for type T
thermometers
Process tools accessories
700HTP-2 Hydraulic
Test Pump
The Fluke 700HTP is
designed to generate pres-
sures up to 10,000 psi/
700 bar. Use the Fluke
700PRV adjustable relief
valves to limit pressures from
94 bar (1360 psi) to 376 bar
(5450 psi)
700HTH-1
Hydraulic Test
Hose
The 700HTH is
a 10,000 psi,
700 bar test hose
that connects to a calibration
unit under test from a Fluke
700HTP hydraulic test pump.
700PMP Pressure
Pump
The 700PMP is a hand-
operated pressure pump
to provide pressures up
to 150 psi/1000 kPa.
Output fitting is 1/8
FNPT.
Fluke 700-IV
Current Shunt
Conversion factor:
10 mV = 1 mA
Accuracy (% of
input, one-year): 0.025 %
Input current: 0 mA to 55 mA
Input resistance: 250 Ω nominal
Output resistance: 10 Ω nominal
Accuracy specification applies
from +18 °C and 28 °C to 50 °C
Maximum input voltage: 30 V dc
www.fluke.com/accessory
92 Accessories
Fluke ac current clamps
i200s i400s
i800
i1000s
i200 i200s i400 i400s i800 i1000s i3000s i2000 Flex i3000s Flex i6000s
AC current range 1 A to 200 A 1 A to 200 A 1 A to 400 A 0.5 A to 400 A 1 A to 800 A 0.2 A to 1000 A 1 A to 3000 A 2 A to 2000 A 3 A to 3000 A 60 A to 6000 A
Accuracy < 3 % + 0.5 A
48 Hz to 65 Hz
< 1 % + 0.5 A
48 Hz to 65 Hz
2 % + 0.06 A
45 Hz to 400 Hz
.5 A to 40 A,
2 % + .015 A, 5 A
to 400 A,
2 % + .04 A,
45 Hz to 400 Hz
0.1 A to 10 A
± 3 % + .01 A,
10 A to 200 A
± 2 %,
200 A to 800 A
± 1 %
0.2 to 10 A:
3 % + 0.1 A
10 A to 100 A:
2 % + 0.5 A
100 A to 1000 A:
1 % + 1 A
48 Hz to 65 Hz
1 to 30 A:
2 % + 0.1 A
1 to 300 A:
2 % + 0.5 A
1 to 3000 A:
2 % + 2 A
48 Hz to 65 Hz
± 1 % of range
45 Hz to 65 Hz
Ranges:
20 A, 200 A,
2000 A
± 1 % of range,
45 Hz to 65 Hz
Ranges:
30 A, 300 A,
3000 A
± 1 % of range
45 Hz to 65 Hz
Bandwidth (-3 dB) 40 Hz to 40 kHz 40 Hz to 40 kHz 5 kHz to 20 kHz 5 Hz to 10 kHz 30 Hz to 10 kHz
(typical) 5 Hz to 100 kHz 10 Hz to 100 kHz 10 Hz to 20 kHz 10 Hz to 50 kHz 10 Hz to 50 kHz,
(- 3 dB)
Maximum
conductor diameter 20 mm (0.8 in) 20 mm (0.8 in) 32 mm (1.25 in) 32 mm (1.25 in) 54 mm (2.13 in) 54 mm (2.13 in) 64 x 100 mm
(2.52 x 3.94 in) 177 mm (7 in) 177 mm (7 in) or
265 mm (10.4 in)
193 mm (7.6 in) or
289 mm (11.4 in)
Maximum
conductor size 150 mm2150 mm2400 mm2 400 mm22x 240 mm² or
1x 500 mm²
2x 240 mm² or
1x 500 mm²
64 mm
(2.52 in)
610 mm
(24 in)
circumference
610 mm or 915 mm
circumference
610 mm (24 in) or
915mm (36 in)
Output levels 1 mA/A 10 mV/A
100 mV/A 1 mA/A 10 mV/A
1 m V/A
1 mA/A 1 m V/A
10 mV/A
100 mV/A
10 mV/A
1 m V/A
0.1 mV/A
100 mV/A
10 mV/A
1 m V/A
100 mV/A
10 mV/A
1 m V/A
50 mV/A
5 m V/A
0.5 mV/A
Output cable 1.5 m shrouded
banana plugs
2 m to BNC
termination
1.5 m shrouded
banana plugs
2.5 m to BNC
termination
1.6 m shrouded
banana plugs
1.6 m to BNC
termination
2.1 m to BNC
termination
2 m with double
shrouded banana
plugs
2.1 m to BNC
termination
2 m to BNC,
4 mm plug
adapter supplied
Warranty One-year One-year One-year One-year One-year One-year One-year One-year One-year One-year
Safety rating CAT III 600 V CAT III 600 V CAT III 1000 V
CAT IV 600 V
CAT III 1000 V
CAT IV 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V
i2000/i3000s/i6000s
Flex
i3000s
i200 i200s i400 i400s i800 i1000s i3000s i2000 Flex1i3000s Flex
114/116 1 A to 200 A 0.6 A to 400 A* 0.6 A to 1000 A* 1 A to 3000 A 2 A to 2000 A 3 A to 3000 A
115/117 60 A to 200 A 1 A to 200 A 60 A to 400 A 0.6 A to
400 A* 60 A to 800 A 0.6 A to 1000 A* 1 A to 3000 A 2 A to 2000 A 3 A to 3000 A
233 60 A to 200 A 1 A to 200 A 60 A to 400 A 0.6 A to
400 A* 60 A to 800 A 0.6 A to 1000 A* 1 A to 3000 A 2 A to 2000 A 3 A to 3000 A
27II 2 A to 200 A 1 A to 200 A 2 A to 400 A 1 A to 400 A* 2 A to 800 A 0.1 A to 1000 A* 1 A to 3000 A 2 A to 2000 A 3 A to 3000 A
28II 1.8 A to 200 A 1 A to 200 A 1.8 A to 400 A 1.8 A to 400 A 1.8 A to 800 A 0.2 A to 1000 A* 2 A to 3000 A 2 A to 2000 A 3 A to 3000 A
77 IV 1 A to 200 A 1 A to 400 A* 0.1 A to 1000 A* 1 A to 3000 A 2 A to 2000 A 3 A to 3000 A
175/177/179 3 A to 200 A 1 A to 200 A 3 A to 400 A 1 A to 400 A* 3 A to 800 A 0.3 A to 1000 A* 3 A to 3000 A 2 A to 2000 A 3 A to 3000 A
1577/1587
Insulation Meter 3 A to 200 A 1 A to 200 A 3 A to 400 A 3 A to 400 A* 3 A to 400 A 0.3 A to 1000 A* 3 A to 3000 A 2 A to 2000 A 3 A to 3000 A
83V/88V 2 A to 200 A 1 A to 200 A 2 A to 400 A 1 A to 400 A* 2 A to 800 A 0.1 A to 1000 A* 1 A to 3000 A 2 A to 2000 A 3 A to 3000 A
87V 2 A to 200 A 1 A to 200 A 2 A to 400 A 2 A to 400 A* 2 A to 800 A 0.2 A to 1000 A* 2 A to 3000 A 2 A to 2000 A 3 A to 3000 A
287/289 1 A to 200 A 1 A to 200 A 1 A to 400 A 0.5 A to 400 A* 1 A to 800 A 0.2 A to 1000 A* 1 A to 3000 A 2 A to 2000 A 3 A to 3000 A
43B Power Quality
Analyzer 1 A to 200 A 0.35 A to 400 A 0.1 A to 1000 A 1 A to 3000 A 2 A to 2000 A 3 A to 3000 A
434/435 Power
Quality Analyzer 1 A to 200 A 1.2 A to 400 A 0.3 A to 1000 A 1.2 A to 3000 A i430Flex-TF-II i430Flex-TF-II
120 Series
ScopeMeters 1 A to 200 A 2.5 A to 400 A 0.25 A to 1000 A 2.5 A to 3000 A 2 A to 2000 A 3 A to 3000 A
190 Series
ScopeMeters 1 A to 200 A 1 A to 400 A 0.1 A to 1000 A 1 A to 3000 A 2 A to 2000 A 3 A to 3000 A
8808A 1 A to 200 A 1 A to 200 A 1 A to 400 A 0.5 A to 400 A* 1 A to 800 A 0.1 A to 1000 A* 1 A to 3000 A 2 A to 2000 A* 3 A to 3000 A*
8845A/8846A 1 A to 200 A 1 A to 200 A 1 A to 400 A 1 A to 400 A* 1 A to 800 A 0.2 A to 1000 A* 1 A to 3000 A 2 A to 2000 A* 3 A to 3000 A*
787/789 Process
Meters 50 A to 200 A 1 A to 200 A 50 A to 400 A 2 A to 400 A* 50 A to 440 A 0.2 A to 1000 A* 2 A to 3000 A 2 A to 2000 A 3 A to 3000 A
* Requires PM9081/001 Adapters.
1 Three range version.
2 Current and watt readings will be multiples of 10 higher or lower than actual on some ranges.
AC current clamp specifications
AC current clamp selection guide
i200 i400
i2000 Flex, i3000s Flex-24 (24 in
dia), i3000s Flex-36 (36 in dia),
i6000s Flex-24 (24 in dia), i6000s
Flex-36 (36 in dia)
www.fluke.com/accessory 93
Accessories
i410 i310s
i30s
i30
Fluke ac/dc current clamps
80i-110s i410 i1010 i30 i30s i310s
DC range 0.1 A to 100 A 1 A to 400 A 1 A to 1000 A 30 mA to 30 A 30 mA to 30 A 0.1 A to 450 A
AC range 0.1 A to 70 A 1 A to 400 A 1 A to 600 A 30 mA to 20 A rms 30 mA to 20 A rms 0.1 A to 300 A
Accuracy
0.1 A to 10 A; dc to
1 kHz: ± 3 % + 50 mA;
up to 100 A add 15 %;
up to 20 kHz add 12 %
3.5 % + 0.5 A for dc or ac
(45 to 400 Hz)
2 % + 0.5 A for dc or ac
(45 to 400 Hz) ± 1 % of reading, ± 2 mA ± 1 % of reading,
± 2 mA
30 A range:
1 % + 50 mA
300 A range:
1 % + 300 mA
Bandwidth (-3 dB) 100 kHZ 3 kHz 10 kHz dc to 20 kHz (-0.5 dB) dc to 100 kHz (-0.5 dB) dc to 20 kHz
Zero error adjustment
Maximum conductor
diameter 11.8 mm (0.46 in) 30 mm (1.18 in) 30 mm (1.18 in) 19 mm (0.75 in) 19 mm (0.75 in) 19 mm (0.75 in)
Maximum conductor size 35 mm21x 400 mm² or 2x 240 mm² 1x 400 mm² or 2x 240 mm² 120 mm² 120 mm² 120 mm²
Output levels 10 mV/A, 100 mV/A 1 mV/A 1 mV/A 100 mV/A 100 mV/A 1 mV/A, 10 mV/A
Output cable 1.6 meter with BNC
termination
1.2 meter with
shrouded banana
plugs
1.2 meter with
shrouded banana
plugs
1.5 meter with
shrouded dual
banana plugs
2 meter with BNC
termination
2 meters with BNC termination
and a BNC to safety shrouded
banana adapter
Battery life 40 hours 60 hours 60 hours 30 hours 30 hours 30 hours
Warranty One-year One-year One-year One-year One-year One-year
Safety CAT II 600 V;
CAT III 300 V CAT III 600 V CAT III 600 V CAT III 300 V CAT III 300 V CAT III 300 V
80i-110s i410 i1010 i30 i30s i310s
114/115/116/117 0.1 A to 100 A dc/
0.1 A to 70 A ac*
1.4 A to 400 A dc/
6 A to 400 A ac
1.4 A to 1000 A dc/
6 A to 600 A ac
30 mA to 30 A dc/
60 mA to 20 A ac
30 mA to 30 A dc/
60 mA to 20 A ac
0.1 A to 450 A dc/
0.6 A to 300 A ac
233 0.1 A to 100 A dc/
0.1 A to 70 A ac*
1.4 A to 400 A dc/
6 A to 400 A ac
1.4 A to 1000 A dc/
6 A to 600 A ac
30 mA to 30 A dc/
60 mA to 20 A ac
30 mA to 30 A dc/
60 mA to 20 A ac
0.1 A to 450 A dc/
0.6 A to 300 A ac
27II 0.1 A to 100 A dc/
0.1 A to 70 A ac*
1 A to 400 A dc/
1 A to 400 A ac
1 A to 1000 A dc/
1 A to 600 A ac
30 mA to 30 A dc/
30 mA to 20 A ac
30 mA to 30 A dc/
30 mA to 20 A ac
0.1 A to 450 A dc/
0.1 A to 300 A ac
28II 0.1 A to 100 A dc/
0.2 A to 70 A ac*
1 A to 400 A dc/
6 A to 400 A ac
1 A to 1000 A dc/
6 A to 600 A ac
30 mA to 30 A dc/
60 mA to 20 A ac
30 mA to 30 A dc/
60 mA to 20 A ac
0.1 A to 450 A dc/
2 A to 300 A ac
77-IV 0.1 A to 100 A dc/
0.1 A to 70 A ac*
1 A to 400 A dc/
5 A to 400 A ac
1 A to 1000 A dc/
5 A to 600 A ac
30 mA to 30 A dc/
40 mA to 20 A ac
30 mA to 30 A dc/
40 mA to 20 A ac
0.1 A to 450 A dc/
0.4 A to 300 A ac
175/177/179 0.11 A to 100 A dc/
0.3 A to 70 A ac*
1.6 A to 400 A dc/
30 A to 400 A ac
1.6 A to 1000 A dc/
30 A to 600 A ac
30 mA to 30 A dc/
300 mA to 20 A ac
30 mA to 30 A dc/
300 mA to 20 A ac
0.1 A to 450 A dc/
3 A to 300 A ac
1577/1587 FC
Insulation Meter
0.1 A to 100 A dc/
0.3 A to 70 A ac*
1.2 A to 400 A dc/
30 A to 400 A ac
1.2 A to 1000 A dc/
30 A to 600 A ac
30 mA to 30 A dc/
300 mA to 20 A ac
30 mA to 30 A dc/
300 mA to 20 A ac
0.1 A to 450 A dc/
3 A to 300 A ac
83V/88V 0.1 A to 100 A dc/
0.1 A to 70 A ac*
1 A to 400 A dc/
1 A to 400 A ac
1 A to 1000 A dc/
1 A to 600 A ac
30 mA to 30 A dc/
30 mA to 20 A ac
30 mA to 30 A dc/
30 mA to 20 A ac
0.1 A to 450 A dc/
0.1 A to 300 A ac
87V 0.1 A to 100 A dc/
0.2 A to 70 A ac*
1 A to 400 A dc/
20 A to 400 A ac
1 A to 1000 A dc/
20 A to 600 A ac
30 mA to 30 A dc/
200 mA to 20 A ac
30 mA to 30 A dc/
200 mA to 20 A ac
0.1 A to 450 A dc/
2 A to 300 A ac
287/289 0.1 A to 100 A dc/
0.1 A to 70 A ac*
1 A to 400 A dc/
1 A to 400 A ac
1 A to 1000 A dc/
1 A to 600 A ac
30 mA to 30 A dc/
30 mA to 20 A ac
30 mA to 30 A dc/
30 mA to 20 A ac
0.1 A to 450 A dc/
0.1 A to 300 A ac
123/124 ScopeMeters 0.1 A to 100 A dc/
0.25 A to 70 A ac
1 A to 400 A dc/
25 A to 400 A ac**
1 A to 1000 A dc/
25 A to 600 A ac**
30 mA to 30 A dc/
250 mA to 20 A ac
0.1 A to 450 A dc/
2.5 A to 300 A ac
190 Series ScopeMeters 0.1 A to 100 A dc/
0.1 A to 70 A ac
1 A to 400 A dc/
5 A to 400 A ac**
1 A to 1000 A dc/
5 A to 600 A ac**
30 mA to 30 A dc/
50 mA to 20 A ac**
30 mA to 30 A dc/
50 mA to 20 A ac
0.1 A to 450 A dc/
0.5 A to 300 A ac
8808A 0.1 A to 100 A dc/
0.1 A to 70 A ac*
1 A to 400 A dc/
2 A to 400 A ac
1 A to 1000 A dc/
2 A to 600 A ac
30 mA to 30 A dc/
30 mA to 20 A ac
30 mA to 30 A dc/
30 mA to 20 A ac
0.1 A to 450 A dc/
0.2 A to 300 A ac
8845A/8846A 0.1 A to 100 A dc/
0.1 A to 70 A ac*
1 A to 400 A dc/
1 A to 400 A ac
1 A to 1000 A dc/
1 A to 600 A ac
30 mA to 30 A dc/
30 mA to 20 A ac
30 mA to 30 A dc/
30 mA to 20 A ac
0.1 A to 450 A dc/
0.1 A to 300 A ac
705/707 0.1 A to 100 A dc, no ac* 4 A to 400 A dc, no ac 4 A to 1000 A dc, No ac 40 mA to 30 A dc, no ac 40 mA to 30 A dc, no ac 0.4 A to 450 A dc, no ac
715 0.1 A to 100 A dc, no ac* 4 A to 400 A dc, no ac 4 A to 1000 A dc, No ac 40 mA to 30 A dc, no ac 40 mA to 30 A dc, no ac 0.1 A to 450 A dc, no ac
787/789 Process Meters 0.1 A to 100 A dc/
0.2 A to 70 A ac*
1 A to 400 A dc/
20 A to 400 A ac
1 A to 1000 A dc/
20 A to 600 A ac
30 mA to 30 A dc/
200 mA to 20 A ac
3 mA to 30 A dc/
200 mA to 20 A ac
0.1 A to 450 A dc/
2 A to 300 A ac
* Requires PM9081 Adapter
** Requires PM9082/001 Adapter
AC/DC current clamp specifications
AC/DC current clamp selection guide
8 0 i-110 s i1010
i310s, i30s and i30
Hall Effect AC/DC
Current Clamps
Especially useful for low
current measurements
down to 30 milliamps.
www.fluke.com/accessory
94 Accessories
LVD1 Volt Light
Exclusive dual-sensitivity
Detects voltages from 40 V ac to
300 V ac
Voltage detector glows blue at 50 Hz to
60 Hz or 2.5 cm to 38 cm (1 in to 5 in)
away from source
Ultra-bright white LED with 100,000
hour bulb life
AAA battery included
LVD2 Volt Light
Non-contact ac voltage detector and
bright white LED flashlight
Detects voltage from 90 V to 600 V ac
from one to 12.7 cm (5 inches) away
CAT IV rated, one-year warranty
L205 Mini Hat Light
Rugged, high-intensity Xenon worklight.
Attaches to a baseball cap
Includes a hat clip
Includes two AAA batteries
Waterproof
L206 Deluxe LED Hat Light
(hard hat not included)
Attach it to a hard hat, a baseball cap,
or even a panel door.
Three super bright white LEDs never
burn out
Special hard-hat attachment included
40-hour battery life
Includes three AAA batteries
Fluke lights and hangers
Free your hands and shed light on the contact point
L215 SureGrip Kit with Probe Light
and Probe Extenders
L200 probe light
TP220 SureGrip test probes
TL224 SureGrip test leads
TP280 test probe extenders
Soft foldable pouch, keeps the entire
set together
L210 Probe Light and Probe
Extenders
20.3 cm (8 in) probe extenders
fit modular test probes
Probe extender complies with
EN 61010-031
Bright white LED illuminates
contact area
Probe light fits on extender or
test probe
TPAK ToolPak
Magnetic Meter
Hanger
Free both hands to
make measurements
Hang your meter
from metallic
surfaces like panels
and pipes
Kit includes universal
hanger clips (two),
hook and loop
straps (two lengths),
adapter and strong
magnet
Attaches to back of
many Fluke meters,
including 110, 170,
180, 280 Series,
87V and 83V DMMs,
724, 725 and 789
Process Calibrators,
70 Series III DMMs,
1503, 1507, 1577
and 1587 Insula-
tion Multimeters and
50 Series II Digital
Thermometers
LeadWrap Test Lead
Fasteners
Keep your favorite
leads together
Hook and loop
fasteners
Three per package
www.fluke.com/accessory 95
Accessories
Stray voltage
SV225
Eliminates stray voltage
due to capacitance
between wires in
electrical installations
Compatible with all
instruments and test leads
that accept standard 4 mm shrouded
banana connectors
Pressure and vacuum
PV350 Pressure
Vacuum Module
Digital pressure
and vacuum
measurements in
a single module
Measures
HVAC/R, hydraulic
and pneumatic pressures to
350 psig/2413 kPa
(usable to 500 psig)
Measures to 760 mmHg (29.9 in Hg)
vacuum (not intended for measuring
microns of vacuum)
Compatible with most digital multimeters
Specialty accessories and software
Get more out of your test tool
Fuse selection guide
Replacement fuses for Fluke DMMs are available from your distributor. To order direct from Fluke call
1-800-44-FLUKE (U.S.) or email fluke-info@fluke.com.
Model Fuse Requirements
21-III/75-III/73-III P/N 871173 630 mA 250 V fuse
P/N 803293 11 A 1000 V fuse
27 (S/N<7247001)
P/N 871173 630 mA 250 V fuse
P/N 871202 3 A 600 V fuse
P/N 892583 15 A 600 V fuse
27 (S/N>7247001 P/N 943121 440 mA 1000 V fuse
P/N 803293 11 A 1000 V fuse
83/85/87 (S/N>6565000) P/N 943121 440 mA 1000 V fuse
P/N 803293 11 A 1000 V fuse
83-III/85-III/87-III 87-IV/89-IV/187/189/287/289/
77-III/79-III/23-III/26-III/175/177/179/77-IV/27-II/28-II
P/N 943121 440 mA 1000 V fuse
P/N 803293 11 A 1000 V fuse
111/112/115/117/233 P/N 803293 11 A 1000 V fuse
1577/1587 P/N 943121 440 mA 1000 V fuse
1503/1507 P/N 2279339 315 mA 1000 V fuse
787/789 P/N 943121 440 mA 1000 V fuse (Qty 2)
FlukeView® Forms
Harness the power of the data logging
function on your Fluke Digital Multimeter,
Thermometer or ProcessMeter. Log live
readings while connected to a PC, or leave
your Fluke 289, 789 or 54-II in place to
capture up to 1,000 readings for download
to a PC.
Choose the model that’s right for you:
FVF-SC2: Includes software and
cable used with 280 Series DMMs and
789 ProcessMeters, and the 1550 and
C/1555 Insulation Tester
FVF-SC3: Includes software and cable
used with 45 Bench Meters
FVF-SC4: Includes software and
cable used with 8845A and 8846A
Multimeters
Go to www.fluke.com/flukeviewforms to
download the demo.
FlukeView® Forms Basic
An abridged version of FlukeView Forms.
Available for use with 280 Series DMMs
and 789 ProcessMeters, only
Upgrade to the full FlukeView Forms
with FVF-UG
Compatible with the 280 and 789 series
only
Choose the model that’s right for you:
FVF-Basic: FlukeView Forms Basic
transfers data from Fluke test tool to a
PC. Displays readings in table or graphi-
cal format
FVF-SC2, -SC4: FlukeView Forms Full
provides Basic software functions plus
customizable documents and templates
FVF-UG: FlukeView Forms Upgrade,
compatible with all forms of
FlukeView Forms (Basic and Full)
Selection
Guide
110/111/112
114/115/116/117
27 II/28 II/27
175/177
179
80 Series III/83V
87/89 IV
87V
233
287/289/187/189
43B
120 Series
190 Series
51/52/53/54 II
705/707
715
725/726
741/743
744
787/789
1587 FC
1577
TPAK 83V 789
PV350
(pressure) •••••••••
FOM (fiber
optic) •••••••••
Fluke Connect®
ir3000 FC Connector
Get all the benefits of the Fluke
Connect app, and be on the same
page, even while in different places
Wirelessly share measurements with
your team anywhere, anytime
Connect the Fluke 289/287 True-rms
Logging Multimeter and the 789
ProcessMeter with the ir3000 FC
Connector
Fluke Connect® Wireless
SD Card
Wirelessly enable your Fluke
TiX1000, TiX660, or TiX640
infrared camera with the
Fluke Connect wireless SD
card. Instantly upload, share
and analyze data with anyone on your
team. The Fluke Connect WiFi SD Card
is included with compatible models, but
is shipped separately due to country
restrictions.
Model Instrument compatibility Cable
FVF-BASIC Fluke 280 Series, 789, 1550B, 1653, 180 Series USB/IR
FVF-SC2 Fluke 280 Series, 789, 1550B, 1653, 180 Series USB/IR
FVF-SC4 Fluke 8808A, 8845A, 8846A, 45* USB/Serial
IR189USB USB cable for Fluke-18X, 28X DMMs USB/IR
96
Applications/videos
www.fluke.com/training
You can depend on www.fluke.com to find the information you need to help you on the
job—and, its all formatted for your smart phone. Besides in-depth product information and
specifications, learn best practices for using Fluke tools, watch expert how-to videos, register
for webinars and more.
In the training section, you’ll find our library of excellent content plus measurement and test
tool basics that cover our core product features: what they’re for and how to use them. In the
community section, look at Fluke News Plus for information from industry professionals that
can further help you take full advantage of your Fluke tools. Some of the materials available
include:
Expert resources and advice
RECORD
15
14
131211109
8
7
6
5
4
3
219
118 17
16
Online fundamentals
www.fluke.com/measurebasics www.fluke.com/dmmbasics
How-to videos
Product videos
Application notes
White papers
Case studies
Webinars
Training library
Hands-on workshops
Users manuals
Resources
Online training