Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 Compact IPM Series
Dual Module
200 Amperes/1200 Volts
MIG200Q2CSB1X
1Rev. 8/05
Description:
Powerex Dual Compact IPM
Series Modules are designed for
use in switching applications. Each
module consists of two IGBT
Transistors in a half-bridge confi gu-
ration, with each transistor having
a reverse-connected super-fast
recovery free-wheel diode. All
components and interconnects
are isolated from the heat sinking
baseplate, offering simplifi ed
system assembly and thermal
management.
Features:
£ Over-Current and
Over-Temperature Protection
£ Low VCE(sat)
£ Isolated Baseplate for Easy
Heat Sinking
Applications:
£ AC Motor Control
£ Motion/Servo Control
£ UPS
£ Welding Power Supplies
£ Laser Power Supplies
Ordering Information:
MIG200Q2CSB1X is a
1200V (VCES), 200 Ampere
Compact IPM Series Dual Module.
Outline Drawing and Circuit Diagram
Dimensions Inches Millimeters
A 4.21±0.04 107.0±1.0
B 2.16±0.04 55.0±1.0
C 1.42±0.03 36.0±0.8
D 3.66±0.01 93.0±0.3
E 0.37±0.03 9.5±0.8
F 2.05±0.02 52.0±0.5
G 4.09±0.02 104.0±0.5
H 0.29±0.03 7.5±0.8
J 0.47 12.0
K 0.35 9.0
L 0.87±0.03 22.0±0.8
M 1.15±0.03 29.24±0.8
N 0.28 7.0
P 1.32+0.04/-0.02 33.5+1.0/-0.5
Dimensions Inches Millimeters
Q 1.24±0.03 31.5±0.8
R 0.22 Dia. 5.5 Dia.
S 0.6 15.24
T 0.87+0.04/-0.01 22.0+1.0/-0.3
U 0.73±0.03 18.5±0.8
V 0.89+0.04/-0.024 22.0+1.0/-0.6
W 0.55 13.9
X M5 Metric M5
Y 0.12 Dia. 3.0 Dia.
Z 0.025 Sq. 0.64 Sq.
AA 0.28 7.0
BB 1.0±0.024 25.4±0.6
CC 0.1 2.54
R
7
5
3
1
DETAIL "A"
A
N
B
C
D
F
G
BB
CC
CC
CC
AA
UV
S
T
JK
E2 C1
C2E1
DETAIL "A"
8
6
4
2
E
E
YZ
X
W
Q
P
L
HL M
1 FO(L)
2 GND(L)
3 IN(L)
4 VD(L)
5 FO(H)
6 GND(H)
7 IN(H)
8 VD(H)
SIGNAL TERMINAL
VD
VS
GND
GND
IN
VD
VS
GND
GND
FO
FO
IN
OUT
C1C2/E1E2
OUT
1 2 3 4 5 6 7 8
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
MIG200Q2CSB1X
Compact IPM Series Dual Module
200 Amperes/1200 Volts
2 Rev. 8/05
Absolute Maximum Ratings, Tj = 25°C unless otherwise specified
Characteristics Symbol MIG200Q2CSB1X Units
Power Device Junction Temperature Tj -20 to 150 °C
Storage Temperature Tstg -40 to 125 °C
Operating Temperature TC -20 to 100 °C
Mounting Torque, M5 Mounting Screws 31 in-lb
Module Weight (Typical) 278 Grams
Isolation Voltage, AC 1 minute, 60Hz Sinusoidal VISO 2500 Volts
IGBT Inverter Sector
Supply Voltage (P-N Power Terminal) VCC 900 Volts
Collector-Emitter Voltage VCES 1200 Volts
Collector Current (TC = 25°C, DC) IC 200 Amperes
Forward Current (TC = 25°C, DC) IF 200 Amperes
Collector Power Dissipation (TC = 25°C) PC 2200 Watts
IGBT Control Sector
Control Supply Voltage (VD-GND Terminal) VD 20 Volts
Input Voltage (IN-GND Terminal) VIN 20 Volts
Fault Output Voltage (FO-GND (L) Terminal) VFO 20 Volts
Fault Output Current (FO Sink Current) IFO 14 mA
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
MIG200Q2CSB1X
Compact IPM Series Dual Module
200 Amperes/1200 Volts
3Rev. 8/05
Electrical and Mechanical Characteristics, Tj = 25°C unless otherwise specified
Characteristics Symbol Test Conditions Min. Typ. Max. Units
IGBT Inverter Sector
Collector Cut-off Current ICEX VCE = 1200V, Tj = 25°C 1 mA
VCE = 1200V, Tj = 125°C 10 mA
Collector-Emitter VCE(sat) VD = 15V, IC = 200A, VIN = 15V to 0V, Tj = 25°C 2.2 2.6 Volts
Saturation Voltage VD = 15V, IC = 200A, VIN = 15V to 0V, Tj = 125°C 3.0 Volts
Forward Voltage VF IF = 200A, Tj = 25°C 2.4 2.8 Volts
ton 2.0 3.0 µs
Switching tc(on) VCC = 600V, IC = 200A, 0.3 µs
Time trr VD = 15V, VIN = 15V to 0V, 0.3 µs
toff Tj = 25°C, Inductive Load 1.5 2.5 µs
tc(off) 0.3 µs
Control Sector
Control Circuit Current ID(H) High Side, VD = 15V 13 17 mA
ID(L) Low Side, VD = 15V 13 17 mA
Input-ON Signal Voltage VIN(on) VD = 15V 1.4 1.6 1.8 Volts
Input-OFF Signal Voltage VIN(off) VD = 15V 2.2 2.5 2.8 Volts
Fault Output Current IFO(on) Protection Current, VD = 15V 8 10 12 mA
IFO(off) Normal Current, VD = 15V 0.1 mA
Over-Current Protection Trip Level OC VD = 15V, Tj 125°C 320 Amperes
Short-Circuit Current SC VD = 15V, Tj 125°C 320 Amperes
Protection Trip Level
Over-Current Cut-off Time toff(OC) 5 µs
Over-Temperature OT Trip Level Case Temperature 110 118 125 °C
Protection OTr Reset Level Case Temperature 98 °C
Control Supply Under UV Trip Level 11.0 12.0 12.5 Volts
Voltage Protection UVr Reset Level 12.0 12.5 13.0 Volts
Fault Output Pulse Width td(FO) VD = 15V 1 2 3 ms
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
MIG200Q2CSB1X
Compact IPM Series Dual Module
200 Amperes/1200 Volts
4 Rev. 8/05
Thermal Characteristics
Characteristic Symbol Condition Min. Typ. Max. Units
Junction to Case Rth(j-c)Q IGBT (Per 1/2 Module) 0.062 °C/Watt
Thermal Resistance Rth(j-c)D
FWDi (Per 1/2 Module) 0.136 °C/Watt
Contact Thermal Resistance Rth(c-f) 0.017 °C/Watt
Recommended Conditions for Use
Characteristic Symbol Condition Min. Typ. Max. Units
Supply Voltage VCC P-N Power Terminals 600 800 Volts
Control Supply Voltage VD VD-GND Signal terminal 13.5 15 16.5 Volts
Switching Frequency fC PMW Control 20 kHz
Dead Time* tDEAD 5 µs
*The table lists Dead Time requirements for the module input, excluding photocoupler delays. When specifying Dead Time requirements for the photocoupler input, please add photocoupler
delays to the Dead Time given above.
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
MIG200Q2CSB1X
Compact IPM Series Dual Module
200 Amperes/1200 Volts
5Rev. 8/05
COLLECTOR CURRENT, IC, (AMPERES)
OUTPUT CHARACTERISTICS
(TYPICAL)
100
200
300
0
400
100
200
300
0
400
100
200
300
0
400
0 53 41 2
COLLECTOR-EMITTER VOLTAGE, VCE(sat), (VOLTS)
Tj = 25°C
FORWARD CURRENT, IF, (AMPERES)
FREE-WHEEL CHARACTERISTICS
(TYPICAL)
0 542 31
FORWARD VOLTAGE, VF, (VOLTS)
Tj = 25°C
Tj = 125°C
VD = 17V
15V
13V
COLLECTOR CURRENT, IC, (AMPERES)
OUTPUT CHARACTERISTICS
(TYPICAL)
0 53 41 2
COLLECTOR-EMITTER VOLTAGE, VCE(sat), (VOLTS)
Tj = 125°C
VD = 17V
15V
13V
101
100
10-1
SWITCHING TIME, tc(off), (µs)
TURN-OFF DELAY TIME VS.
COLLECTOR CURRENT
(TYPICAL)
101
100
10-1
SWITCHING TIME, tc(on), (µs)
TURN-ON DELAY TIME VS.
COLLECTOR CURRENT
(TYPICAL)
101
100
10-1
SWITCHING TIME, toff, (µs)
TURN-OFF TIME VS.
COLLECTOR CURRENT
(TYPICAL)
101
100
10-1
SWITCHING TIME, ton, (µs)
TURN-ON TIME VS.
COLLECTOR CURRENT
(TYPICAL)
0 25020015010050
COLLECTOR CURRENT, IC, (AMPERES)
COLLECTOR CURRENT, IC, (AMPERES)
0 25020015050 100 0 25020015050 100
COLLECTOR CURRENT, IC, (AMPERES) COLLECTOR CURRENT, IC, (AMPERES)
VCC = 600V
VD = 15V
Tj = 25°C
Tj = 125°C
VCC = 600V
VD = 15V
Tj = 25°C
Tj = 125°C
VCC = 600V
VD = 15V
Tj = 25°C
Tj = 125°C
VCC = 600V
VD = 15V
Tj = 25°C
Tj = 125°C
102
101
100
0 250150 20010050
COLLECTOR CURRENT, IC, (AMPERES)
SWITCHING LOSS, Eoff, (mJ/PULSE)
SWITCHING LOSS (OFF) VS.
COLLECTOR CURRENT
(TYPICAL)
VCC = 600V
VD = 15V
Tj = 25°C
Tj = 125°C
VCC = 600V
VD = 15V
Tj = 25°C
Tj = 125°C
0 250150 20010050
COLLECTOR CURRENT, IC, (AMPERES)
102
101
100
SWITCHING LOSS, Eon, (mJ/PULSE)
SWITCHING LOSS (ON) VS.
COLLECTOR CURRENT
(TYPICAL)
0 25020015050 100
Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
MIG200Q2CSB1X
Compact IPM Series Dual Module
200 Amperes/1200 Volts
6 Rev. 8/05
CONTROL CIRCUIT CURRENT, ID(H), (mAMPERES)
0
CARRIER FREQUENCY, fC, (kHz)
HIGH SIDE CONTROL CIRCUIT CURRENT
VS. CARRIER FREQUENCY
(TYPICAL)
0
20
10
30
40
50
5 10 2515 20
OVER CURRENT PROTECTION TRIP LEVEL, OC, (AMPERES)
0
CASE TEMPERATURE, TC, (°C)
OVER CURRENT PROTECTION TRIP LEVEL
VS. CASE TEMPERATURE
(TYPICAL)
0
100
200
300
400
500
600
100 1505025 75 125
VD = 15V
VD = 15V
Tj = 25°C
CONTROL CIRCUIT CURRENT, ID(L), (mAMPERES)
0
CARRIER FREQUENCY, fC, (kHz)
LOW SIDE CONTROL CIRCUIT CURRENT
VS. CARRIER FREQUENCY
(TYPICAL)
0
20
10
30
40
50
5 10 2515 20
VD = 15V
Tj = 25°C
TIME, (s)
TRANSIENT IMPEDANCE, Rth(j-c)
10-3 10-2 10-1 100101
TRANSIENT THERMAL
IMPEDANCE CHARACTERISTICS
(IGBT)
100
10-2
10-4
10-3
10-1
TIME, (s)
TRANSIENT IMPEDANCE, Rth(j-c)
10-3 10-2 10-1 100101
TRANSIENT THERMAL
IMPEDANCE CHARACTERISTICS
(FWDi)
100
10-2
10-4
10-3
10-1
SINGLE PULSE
STANDARD VALUE = Rth(j-c)Q = 0.062°C/W
SINGLE PULSE
STANDARD VALUE = Rth(j-c)D = 0.136°C/W
TC = 25°C TC = 25°C
103
102
101
0 250100 150 20050 0 250100 150 20050
FORWARD CURRENT, IF, (AMPERES)
PEAK REVERSE RECOVERY CURRENT, Irr, (AMPERES)
REVERSE RECOVERY CURRENT
(TYPICAL )
Tj = 25°C
Tj = 125°C
103
102
101
FORWARD CURRENT, IF, (AMPERES)
REVERSE RECOVERY TIME, trr, (ns)
REVERSE RECOVERY TIME
(TYPICAL )
Tj = 25°C
Tj = 125°C
COLLECTOR CURRENT, IC, (AMPERES)
0
COLLECTOR-EMITTER VOLTAGE, VCE, (VOLTS)
REVERSE BIAS
SAFE OPERATION AREA
(TYPICAL)
0
200
400
300
100
400 800 16001200
VD = 15V
Tj 125°C
OC