Notes
A.
Performance and quality attributes and conditions not expressly stated in this specification document are intended to be excluded and do not form a part of this specification document.
B.
Electrical specifications and performance data contained in this specification document are based on Mini-Circuit’s applicable established test performance criteria and measurement instructions.
C.
The parts covered by this specification document are subject to Mini-Circuits standard limited warranty and terms and conditions (collectively, “Standard Terms”); Purchasers of this part are entitled
to the rights and benefits contained therein. For a full statement of the Standard Terms and the exclusive rights and remedies thereunder, please visit Mini-Circuits’ website at www.minicircuits.com/MCLStore/terms.jsp
Mini-Circuits®
www.minicircuits.com P.O. Box 35166, Brooklyn, NY 11235-0003 (718) 934-4500 sales@minicircuits.com Page 1 of 1
Typical Performance Data
Electrical Specications
Maximum Ratings
Operating Temperature -55°C to 100°C
Storage Temperature -55°C to 100°C**
Outline Drawing
Outline Dimensions ( )
BW-40N100W+
ATTENUATION
35
37
39
41
43
45
0 1000 2000 3000 4000
FREQUENCY(MHz)
ATTENUATION (dB)
inch
mm
BW-40N100W+
50 100W 40dB DC to 4000 MHz
N-Type Fixed Attenuator
REV. B
M98898
ED-10917
BW-40N100W+
TD/FL/CP
130918
Coaxial
BCDE FGwt.
3.46 3.46 6.36 -- 1.75 .23 grams
87.88 87.88 161.54 -- 44.45 5.84 1100.0
CASE STYLE: GH986
Connectors Model Price Qty.
N-Male-N-Fem BW-40N100W+ $249.00 ea. (1-9)
BW-40N100W+
VSWR
1.0
1.2
1.4
1.6
0 1000 2000 3000 4000
FREQUENCY (MHz)
VSWR
Temperature coefficient for attenuation .0004 dB/dB/°C typ.
1. Useable to 5 GHz
2. Average power at 25°C ambient, derate linearly to 50W at 100°C, bi-directional
Peak power 1kW max., 5µ sec pulse width, 100 Hz PRF
Features
• DC to 4000 MHz
• excellent VSWR, 1.20:1
• N-Male and N-Female connectors
bi-directional
Applications
• matching
• instrumentation
• test set-ups
FREQ.
RANGE1
(MHz)
ATTENUATION
(dB)
VSWR
(:1)
POWER2
(W)
DC-0.5 GHz 0.5-2 GHz 2-4 GHz
fL--fUNom. ACCURACY Max. Max. Max.
DC-4000 40 ±1.6 1.15 1.35 1.4 100
Frequency
(MHz)
Attenuation
(dB)
VSWR
(:1)
1.00 40.49 1.03
320.92 40.53 1.04
640.84 40.63 1.06
960.76 40.63 1.09
1280.68 40.61 1.11
1600.60 40.55 1.13
1920.52 40.46 1.14
2080.48 40.39 1.15
2560.36 40.14 1.16
2880.28 39.97 1.16
3200.20 39.89 1.16
3520.12 39.75 1.15
3680.08 39.69 1.14
3840.04 39.62 1.14
4000.00 39.56 1.14
**With mated connectors. Unmated, 85°C max.
Permanent damage may occur if any of these limits are exceeded.
+RoHS Compliant
The +Suffix identifies RoHS Compliance. See our web site
for RoHS Compliance methodologies and qualifications