1
CSM_E2FQ_DS_E_3_1
Chemical-resistant Proximity Sensor
E2FQ
Inductive Proximity Sensor with
Chemical-resistant Fluororesin Case
Housing and mounting are made of Fluororesin resistant to
chemicals.
Maximum sensing distance: 10 mm.
Be sure to read Safety Precautions on
page 5.
Note: The cable is made of vinyl chloride and requires separate protection.
Ordering Information
Sensors [Refer to Dimensions on page 6.]
Appearance Sensing distance Output configuration Operation mode Model
M12 DC 2-wire
NO
E2FQ-X2D1 2M
DC 3-wire, NPN E2FQ-X2E1 2M
M18
DC 2-wire E2FQ-X5D1 2M
DC 3-wire, NPN E2FQ-X5E1 2M
AC 2-wire E2FQ-X5Y1 2M
M30
DC 2-wire E2FQ-X10D1 2M
DC 3-wire, NPN E2FQ-X10E1 2M
AC 2-wire E2FQ-X10Y1 2M
Shielded
2 mm
5 mm
10 mm
E2FQ
2
Ratings and Specifications
* The response frequency is an average value.
Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
Model E2FQ-X2E1
E2FQ-X2D1
E2FQ-X5E1
E2FQ-X5D1, E2FQ-X5Y1
E2FQ-X10E1
E2FQ-X10D1, E2FQ-X10Y1
Item
Sensing distance 2 mm ±10% 5 mm ±10% 10 mm ±10%
Set distance 0 to 1.6 mm 0 to 4 mm 0 to 8 mm
Differential travel E1/Y1 Models: 10% max. of sensing distance, D1 Models: 20% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 3.)
Standard sensing object Iron, 12 × 12 × 1 mm Iron, 18 × 18 × 1 mm Iron, 30 × 30 × 1 mm
Response frequency *E1 Models: 1.5 kHz
D1 Models: 800 Hz
E1 Models: 600 Hz
D1 Models: 500 Hz
E1 Models: 400 Hz
D1 Models: 300 Hz
Y1 Models: 25 Hz
Power supply voltage
(operating voltage
range)
E1 Models: 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
Y1 Models: 24 to 240 VAC (20 to 264 VAC), 50/60 Hz
D1 Models: 12 to 24 VDC (10 to 36 VDC), ripple (p-p): 20% max.
Current consumption E1 Models: 17 mA max.
Leakage current D1 Models: 0.8 mA max., Y1 Models: 1.7 mA max. (at 200 VAC)
Control
output
Load
current E1 Models: 200 mA max., D1 Models: 5 to 100 mA, Y1 Models: 5 to 300 mA
Residual
voltage
E1 Models: 2 V max. (Load current: 200 mA, Cable length: 2 m)
Y1 Models: Refer to Engineering Data on page 3.
D1 Models: 4 V max. (Load current: 100 mA, Cable length: 2 m)
Indicators E/D Models: Detection indicator (red), Y Models: Operation indicator (red)
Operation mode
(with sensing object
approaching)
E1/D1/Y1 Models: NO (Refer to the timing charts under I/O Circuit Diagrams on page 5 for details.)
Protection circuits E1 Models: Load short-circuit protection, Reverse polarity protection, Surge suppressor, D1/Y1 Models: Surge sup-
pressor
Ambient temperature
range Operating/Storage: 25 to 70°C (with no icing or condensation)
Ambient humidity range Operating/Storage: 35% to 95% (with no condensation)
Temperature influence ±10% max. of sensing distance at 23°C in the temperature range of 25 to 70°C
Voltage influence
E1 Models: ±2.5% max. of sensing distance at rated voltage in the rated voltage ±15% range
D1 Models: ±2.5% max. of sensing distance at rated voltage in the rated voltage ±20% range
Y1 Models: ±1% max. of sensing distance at rated voltage in the rated voltage ±10% range
Insulation resistance 50 M min. (at 500 VDC) between current-carrying parts and case
Dielectric strength E1/D1 Models: 1,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Y Models: 4,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 500 m/s2 10 times each
in X, Y, and Z directions Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions
Degree of protection IEC 60529 IP67, in-house standards: oil-resistant
Connection method Pre-wired Models (Cable length: 2 m)
Weight (packed state) Approx. 70 g Approx. 130 g Approx. 170 g
Materials
Case
Fluororesin
Sensing
surface
Clamping
nuts
Toothed
washer Zinc-plated iron
Cable Vinyl chloride
Accessories Instruction manual
E2FQ
3
Engineering Data (Typical)
Sensing Area
E2FQ-X@
Influence of Sensing Object Size and Material
E2FQ-X2@E2FQ-X5@E2FQ-X10@
Residual Output Voltage
E2FQ-X@E2FQ-X@Y1 at 24 VAC
Y
X
8
4
2
6
10
-20 -16 -12 -8 -4 0 4 8 12 16
E2FQ-X10
E2FQ-X5
E2FQ-X2
Distance Y
(mm)
Distance X (mm)
E2FQ-X2 Sensing Head
E2FQ-X5 Sensing Head
E2FQ-X10 Sensing Head
2.4
2.2
2
1.8
1.6
1.4
1.2
1
0.8
0.6
0.4
0.2
0 5 10 15 20 25
X
d ×
d t = 1
mm
Side length of sensing object: d (mm)
Distance X (mm)
Aluminum
Stainless steel
(SUS304)
Iron
Brass
7
6
5
4
3
2
1
0 5 10 15 20 25 30 35 40 50
X
d ×
d t = 1 mm
Side length of sensing object: d (mm)
Distance X (mm)
Aluminum
Stainless
steel
(SUS304)
Iron
Brass
12
11
10
9
8
7
6
5
4
3
2
1
100
X
403020 6050
d ×
d t = 1 mm
Side length of sensing object: d (mm)
Distance X (mm)
Aluminum
Stainless
steel
(SUS304)
Iron
Brass
5
4
3
2
1
0
1 3 5 10 30 50 100 300 500 1,000
Load current (mA)
Residual output voltage (V)
24 VAC
VL
V
~
~
A
30
20
10
0
OFF
ON
1 3 5 10 30 50 100 300 500 1,000
24 VAC
Load current (mA)
Residual
Load
Voltage
Residual output
voltage
Load voltage VL (V)
E2FQ
4
E2FQ-X@Y1 at 100 VAC E2FQ-X@Y1 at 200 VAC
Leakage Current
E2FQ-X@DE2FQ-X@Y
100 VAC
VL
V
~
~
A
120
100
80
60
40
20
0
OFF
ON
1 3 5 10 30 50 100 300
Load current (mA)
Residual
output voltage
Residual
load
voltage
Load voltage VL (V)
200 VAC
VL
V
~
~
A
240
200
160
120
80
40
0
OFF
ON
1 3 5 10 30 50 100 300
Load current (mA)
Residual
output voltage
Residual
load
voltage
Load voltage VL (V)
0 10 20 30 40
1.0
0.8
0.6
0.4
0.2
Power supply voltage (V)
Leakage current (mA)
2.0
1.5
1.0
0 50 100 150 200 250
V
~
mA
~
Power supply voltage (V)
AC
power,
50/60Hz
Protective resistance
Proximity
Sensor
(OFF)
Leakage current (mA)
E2FQ
5
I/O Circuit Diagrams
Safety Precautions
Refer to Warranty and Limitations of Liability.
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
Do not use this product under ambient conditions that exceed the
ratings.
Design
Influence of Surrounding Metal
When mounting the Sensor within a metal panel, ensure that the
clearances given in the following table are maintained. Failure to
maintain these distances may cause deterioration in the performance
of the Sensor.
Influence of Surrounding Metal (Unit: mm)
Mutual Interference
When installing two or more Sensors face-to-face or side-by-side,
ensure that the minimum distances given in the following table are
maintained.
Mounting
Do not tighten the nut with excessive force. A washer must be used
with the nut.
Note: The following torque assume washers are being used.
Miscellaneous
Chemical Resistance
Refer to Chemical Resistance for details.
Operation
mode
Output con-
figuration Model Timing chart Output circuit
NO
NPN
E2FQ-X2E1
E2FQ-X5E1
E2FQ-X10E1
DC 2-wire
E2FQ-X2D1
E2FQ-X5D1
E2FQ-X10D1
AC 2-wire E2FQ-X5Y1
E2FQ-X10Y1
WARNING
H
L
Present
Not present
Operate
Reset
Load
(between brown
and black leads)
(between black and
blue leads)
Output voltage
Sensing object
ON
OFF
Detection indicator
(red)
2.2
4.7 k
100
Tr
0 V
+
V
*1
*2
Brown
Black
Output
Blue
Proximity
Sensor
main
circuit
*1. 200 mA max. (load current).
*2. When a transistor is connected.
Load
Detection indicator
(red)
Operate
Reset
ON
OFF
Load
Sensing object Present
Not present
0 V
+V
Load
Brown
Blue
Proximity
Sensor
main
circuit
Note: The load can be connected to either
the +V or 0 V side.
Operation
indicator (red)
Operate
Reset
ON
OFF
Load
Sensing object
Present
Not present
Load
Brown
Blue
Proximity
Sensor
main
circuit
Precautions for Correct Use
Model Item l d D m n
E2FQ-X2@
0
12
0
818
E2FQ-X5@18 20 27
E2FQ-X10@30 40 45
l
m
n
l
mD
d dia. Model Torque
E2FQ-X2@0.98 N·m
E2FQ-X5@
2 N·m
E2FQ-X10@
Mutual Interference (Unit: mm)
Model Item A B
E2FQ-X2@30 20
E2FQ-X5@50 35
E2FQ-X10@100 70
A
B
E2FQ
6
Dimensions (Unit: mm)
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
E2FQ-X2E1
24
27
38
17
21 dia.
6
M12 × 1
*
Two toothed washers
Two clamping nuts
Detection indicator (red)
* 6-dia. vinyl-insulated round cable with 3 conductors (Flame
resistant, Conductor cross section: 0.5 mm2, Insulator diameter:
1.9 mm), Standard length: 2 m
The cable can be extended up to 200 m (separate metal conduit).
E2FQ-X2D1
24
27
38
17
21 dia.
M12 × 16
*
Two toothed washers
Two clamping nuts
Detection indicator (red)
* 6-dia. vinyl-insulated round cable with 2 conductors (Flame
resistant, Conductor cross section: 0.5 mm2, Insulator diameter:
1.9 mm), Standard length: 2 m
The cable can be extended up to 200 m (separate metal conduit).
E2FQ-X5E1
24 29
32
47
40
29 dia.
M18 × 18
*
Two toothed washers
Two clamping nuts
Detection indicator (red)
* 6-dia. vinyl-insulated round cable with 3 conductors (Flame
resistant, Conductor cross section: 0.5 mm2, Insulator diameter:
1.9 mm), Standard length: 2 m
The cable can be extended up to 200 m (separate metal conduit).
E2FQ-X5D1
E2FQ-X5Y1
24 29
32
47
40
29 dia.
M18 × 18
*1
Two toothed washers
Two clamping nuts
Indicator (red) *2
*1. 6-dia. vinyl-insulated round cable with 2 conductors (Flame-
resistant, Conductor cross section: 0.5 mm2, Insulator diameter:
1.9 mm), Standard length: 2 m
The cable can be extended up to 200 m (separate metal conduit).
*2. D Models: Detection indicator, Y Models: Operation indicator
38
41
50
57
36
42 dia.
M30 × 1.5 8
*
Two toothed washers
Two clamping nuts
Detection indicator (red)
* 6-dia. vinyl-insulated round cable with 3 conductors (Flame
resistant, Conductor cross section: 0.5 mm2, Insulator diameter:
1.9 mm), Standard length: 2 m
The cable can be extended up to 200 m (separate metal conduit).
E2FQ-X10E1
38
41
50
57
36
42 dia.
M30 × 1.5 8
*1
Two toothed washers
Two clamping nuts
Indicator (red) *2
*1. 6-dia. vinyl-insulated round cable with 2 conductors (Flame-resistant,
Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm),
Standard length: 2 m
The cable can be extended up to 200 m (separate metal conduit).
*2. D Models: Detection indicator, Y Models: Operation indicator
E2FQ-X10D1
E2FQ-X10Y1
Mounting Hole Dimensions
Model F (mm)
E2FQ-X2@12.5 dia.
E2FQ-X5@18.5 dia.
E2FQ-X10@30.5 dia.
+0.5
0
+0.5
0
+0.5
0
F
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2008.11
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2008 All Right Reserved.