Chemical-resistant Proximity Sensor E2FQ CSM_E2FQ_DS_E_3_1 Inductive Proximity Sensor with Chemical-resistant Fluororesin Case * Housing and mounting are made of Fluororesin resistant to chemicals. * Maximum sensing distance: 10 mm. Be sure to read Safety Precautions on page 5. Note: The cable is made of vinyl chloride and requires separate protection. Ordering Information Sensors [Refer to Dimensions on page 6.] Appearance M12 Shielded M18 M30 Sensing distance 2 mm 5 mm 10 mm Output configuration Operation mode DC 2-wire DC 3-wire, NPN DC 2-wire DC 3-wire, NPN NO AC 2-wire DC 2-wire DC 3-wire, NPN AC 2-wire Model E2FQ-X2D1 2M E2FQ-X2E1 2M E2FQ-X5D1 2M E2FQ-X5E1 2M E2FQ-X5Y1 2M E2FQ-X10D1 2M E2FQ-X10E1 2M E2FQ-X10Y1 2M 1 E2FQ Ratings and Specifications Model E2FQ-X2E1 E2FQ-X2D1 Item E2FQ-X5E1 E2FQ-X5D1, E2FQ-X5Y1 E2FQ-X10E1 E2FQ-X10D1, E2FQ-X10Y1 Sensing distance 2 mm 10% 5 mm 10% 10 mm 10% Set distance 0 to 1.6 mm 0 to 4 mm 0 to 8 mm Differential travel E1/Y1 Models: 10% max. of sensing distance, D1 Models: 20% max. of sensing distance Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 3.) Standard sensing object Iron, 12 x 12 x 1 mm Iron, 18 x 18 x 1 mm Iron, 30 x 30 x 1 mm E1 Models: 600 Hz D1 Models: 500 Hz E1 Models: 400 Hz D1 Models: 300 Hz Response frequency * E1 Models: 1.5 kHz D1 Models: 800 Hz Power supply voltage (operating voltage range) E1 Models: 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. Y1 Models: 24 to 240 VAC (20 to 264 VAC), 50/60 Hz D1 Models: 12 to 24 VDC (10 to 36 VDC), ripple (p-p): 20% max. Current consumption E1 Models: 17 mA max. Leakage current D1 Models: 0.8 mA max., Y1 Models: 1.7 mA max. (at 200 VAC) Control output Y1 Models: 25 Hz Load current E1 Models: 200 mA max., D1 Models: 5 to 100 mA, Y1 Models: 5 to 300 mA Residual voltage E1 Models: 2 V max. (Load current: 200 mA, Cable length: 2 m) Y1 Models: Refer to Engineering Data on page 3. D1 Models: 4 V max. (Load current: 100 mA, Cable length: 2 m) Indicators E/D Models: Detection indicator (red), Y Models: Operation indicator (red) Operation mode (with sensing object approaching) E1/D1/Y1 Models: NO (Refer to the timing charts under I/O Circuit Diagrams on page 5 for details.) Protection circuits E1 Models: Load short-circuit protection, Reverse polarity protection, Surge suppressor, D1/Y1 Models: Surge suppressor Ambient temperature range Operating/Storage: -25 to 70C (with no icing or condensation) Ambient humidity range Operating/Storage: 35% to 95% (with no condensation) Temperature influence 10% max. of sensing distance at 23C in the temperature range of -25 to 70C Voltage influence E1 Models: 2.5% max. of sensing distance at rated voltage in the rated voltage 15% range D1 Models: 2.5% max. of sensing distance at rated voltage in the rated voltage 20% range Y1 Models: 1% max. of sensing distance at rated voltage in the rated voltage 10% range Insulation resistance 50 M min. (at 500 VDC) between current-carrying parts and case Dielectric strength E1/D1 Models: 1,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case Y Models: 4,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions Shock resistance Destruction: 500 m/s2 10 times each in X, Y, and Z directions Degree of protection IEC 60529 IP67, in-house standards: oil-resistant Connection method Pre-wired Models (Cable length: 2 m) Weight (packed state) Approx. 70 g Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions Approx. 130 g Approx. 170 g Case Sensing surface Materials Fluororesin Clamping nuts Toothed washer Cable Accessories Zinc-plated iron Vinyl chloride Instruction manual * The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance. 2 E2FQ Engineering Data (Typical) Sensing Area Distance X (mm) E2FQ-X@ E2FQ-X10 10 Y 8 X 6 E2FQ-X5 4 E2FQ-X2 2 -20 -16 -12 -8 -4 0 4 8 E2FQ-X2 Sensing Head 12 16 Distance Y (mm) E2FQ-X5 Sensing Head E2FQ-X10 Sensing Head Influence of Sensing Object Size and Material 2.4 dx d 2.2 t = 1 mm Iron X 2 1.8 Stainless steel (SUS304) 1.6 1.4 E2FQ-X10@ 7 dx d t = 1 mm X 6 Iron 5 Stainless steel (SUS304) 4 1.2 Distance X (mm) E2FQ-X5@ Distance X (mm) Distance X (mm) E2FQ-X2@ 12 11 dx d 3 1 8 7 Stainless steel (SUS304) 5 Brass Brass 2 0.6 Aluminum Aluminum 0.4 Iron 9 6 0.8 t = 1 mm X 10 Brass 4 3 Aluminum 2 1 1 0.2 0 5 0 10 15 20 25 Side length of sensing object: d (mm) 5 10 15 20 25 30 35 40 50 Side length of sensing object: d (mm) 0 10 20 30 40 50 60 Side length of sensing object: d (mm) Residual Output Voltage E2FQ-X@Y1 at 24 VAC 5 Load voltage VL (V) Residual output voltage (V) E2FQ-X@ 4 30 24 VAC 20 Residual output voltage ON 3 V ~ 2 10 VL ~ 1 0 24 VAC A Residual Load Voltage 1 3 5 10 30 50 100 300 500 1,000 Load current (mA) 01 3 OFF 5 10 30 50 100 300 500 1,000 Load current (mA) 3 E2FQ 120 E2FQ-X@Y1 at 200 VAC Residual output voltage Load voltage VL (V) Load voltage VL (V) E2FQ-X@Y1 at 100 VAC ON 100 80 ~ 30 50 VL 200 VAC A ~ 80 40 Residual load voltage 01 3 OFF 10 V ~ 100 VAC ~A 20 Residual load voltage 01 3 5 ON 200 120 VL 40 Residual output voltage 160 V 60 240 100 300 Load current (mA) OFF 5 10 30 50 100 300 Load current (mA) Leakage Current E2FQ-X@Y Leakage current (mA) Leakage current (mA) E2FQ-X@D 1.0 0.8 0.6 2.0 Protective resistance mA ~ V ~ 1.5 Proximity Sensor (OFF) AC power, 50/60Hz 0.4 1.0 0.2 0 10 20 30 40 Power supply voltage (V) 0 50 100 150 200 250 Power supply voltage (V) 4 E2FQ I/O Circuit Diagrams Operation mode Output configuration Model Timing chart Output circuit Brown Sensing object Not present Load Operate E2FQ-X2E1 E2FQ-X5E1 E2FQ-X10E1 NPN (between brown and black leads) Load (between black and blue leads) 4.7 k Proximity Sensor main circuit Reset H Output voltage +V 100 Present Black 2.2 *1 *2 Output Tr L Blue ON Detection indicator (red) OFF 0V *1. 200 mA max. (load current). *2. When a transistor is connected. Brown Load +V NO Present Sensing object DC 2-wire Proximity Sensor main circuit Not present E2FQ-X2D1 E2FQ-X5D1 E2FQ-X10D1 Operate Load Reset Blue ON Detection indicator (red) 0V OFF Note: The load can be connected to either the +V or 0 V side. Brown Sensing object Present AC 2-wire E2FQ-X5Y1 E2FQ-X10Y1 Operate Load Reset Operation indicator (red) Load Proximity Sensor main circuit Not present Blue ON OFF Safety Precautions Refer to Warranty and Limitations of Liability. WARNING This product is not designed or rated for ensuring safety of persons either directly or indirectly. Do not use it for such purposes. Mutual Interference When installing two or more Sensors face-to-face or side-by-side, ensure that the minimum distances given in the following table are maintained. Mutual Interference (Unit: mm) Precautions for Correct Use Do not use this product under ambient conditions that exceed the ratings. Design Influence of Surrounding Metal When mounting the Sensor within a metal panel, ensure that the clearances given in the following table are maintained. Failure to maintain these distances may cause deterioration in the performance of the Sensor. Model A B 30 20 E2FQ-X5@ 50 35 E2FQ-X10@ 100 70 E2FQ-X2@ Item A B Mounting Do not tighten the nut with excessive force. A washer must be used with the nut. l Note: The following torque assume washers are being used. n m d dia. D m l Influence of Surrounding Metal Model Item l E2FQ-X2@ E2FQ-X5@ E2FQ-X10@ d D 0 18 30 0 E2FQ-X2@ E2FQ-X5@ (Unit: mm) 12 Model m n 8 18 20 27 40 45 E2FQ-X10@ Torque 0.98 N*m 2 N*m Miscellaneous Chemical Resistance Refer to Chemical Resistance for details. 5 E2FQ (Unit: mm) Dimensions Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified. E2FQ-X2D1 E2FQ-X2E1 38 21 dia. 38 21 dia. 27 24 17 27 24 17 * Detection indicator (red) Two clamping nuts M12 x 1 M12 x 1 6 Two toothed washers * 6-dia. vinyl-insulated round cable with 3 conductors (Flame resistant, Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m The cable can be extended up to 200 m (separate metal conduit). E2FQ-X5E1 * Detection indicator (red) Two clamping nuts 6 Two toothed washers * 6-dia. vinyl-insulated round cable with 2 conductors (Flame resistant, Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m The cable can be extended up to 200 m (separate metal conduit). E2FQ-X5D1 E2FQ-X5Y1 47 47 29 dia. 24 40 32 29 29 dia. 40 32 29 24 *1 * Indicator (red) *2 Detection indicator (red) M18 x 1 8 M18 x 1 Two clamping nuts 8 Two clamping nuts Two toothed washers *1. 6-dia. vinyl-insulated round cable with 2 conductors (Flameresistant, Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m The cable can be extended up to 200 m (separate metal conduit). *2. D Models: Detection indicator, Y Models: Operation indicator Two toothed washers * 6-dia. vinyl-insulated round cable with 3 conductors (Flame resistant, Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m The cable can be extended up to 200 m (separate metal conduit). E2FQ-X10D1 E2FQ-X10Y1 E2FQ-X10E1 57 57 50 42 dia. 41 36 50 42 dia. 41 36 38 38 *1 * Indicator (red) *2 Detection indicator (red) M30 x 1.5 Two clamping nuts 8 Two toothed washers * 6-dia. vinyl-insulated round cable with 3 conductors (Flame resistant, Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m The cable can be extended up to 200 m (separate metal conduit). M30 x 1.5 8 Two clamping nuts Two toothed washers *1. 6-dia. vinyl-insulated round cable with 2 conductors (Flame-resistant, Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m The cable can be extended up to 200 m (separate metal conduit). *2. D Models: Detection indicator, Y Models: Operation indicator Mounting Hole Dimensions Model F F (mm) E2FQ-X2@ 12.5 +0.5 0 dia. E2FQ-X5@ 18.5 +0.5 0 dia. E2FQ-X10@ 30.5 +0.5 0 dia. 6 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: * Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. * Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. * Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2008.11 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2008 All Right Reserved.