Rev. 10.23.12_131
LCM600 Series
2 of 6
Embedded Power for
Business-Critical Continuity
OrderingInformation
Model
Number* Output Nominal Output
Voltage Set Point
Set Point
Tolerance
Adjustment
Range
Current Output Ripple
P/P
Power
Max.
Combined Line/
Load Regulation
Min Max
LCM600L 12V 12V ±0.5% 9.6-14.4V 0A 52A 120mV 600 W 2%
LCM600N 15V 15V ±0.5% 12.0-19.5V 0A 44A 150mV 600 W 2%
LCM600Q 24V 24V ±0.5% 19.2-28.8V 0A 27A 240mV 600 W 2%
LCM600U 36V 36V ±0.5% 28.8-43.2V 0A 16.7A 240mV 600 W 2%
LCM600W 48V 48V ±0.5% 38.4-57.6V 0A 14A 280mV 600 W 2%
*Note:Add“-T”forterminalblockinsteadofIECinput.
Add”-4”For5V,SB
Operatingtemperature: -40°Cto+70°C,linearderatingto50%from50°Cto70°C
Storagetemperature: -40°Cto+85°C
Humidity: 20to90%,non-condensing.Operating.Conformalcoatoptionavailable
Fannoise: <45dBA,80%loadat30°C“-N”LowNoiseOption<35dBA,80%Loadat30°C
Altitude: Operating-15,000feet
Storage-30,000feet
Shock: MIL-STD-810F516.5,ProcedureI,VI.Storage
Vibration: MIL-STD-810F514.5,Cat.4,10.Storage
EnvironmentalSpecifications
Output
Outputrating: Seetable1 85-264Vac
Setpoint: ±0.5% 85-264Vac
Totalregulationrange: Mainoutput±2%
5Vsb±1%
Combinedline/load/transientwhenmeasuredatoutputterminal
Ratedload: 600Wmaximum Deratelinearto50%from50°Cto70°C
Minimumload: Mainoutput@0.0A
5Vsb@0.0A
Nolossofregulation
Outputnoise(PARD): 1%maxp-p
50mVmaxp-p
Mainoutput
5Vsboutput
Measuredwitha0.1µFCeramicand10µFTantalumCapacitoron
anyoutput,20MHz
Outputvoltageovershoot: Noovershoot/undershootoutsidetheregulationbandduringonor
off cycle
Transientresponse: <300µSec 50%loadstep@1A/µs
Steploadvalidbetween10%to100%ofoutputrating
Recoverytimetowithin1%ofsetpointatonsetoftransient
Maxunitsinparallel: Upto10
Shortcircuitprotection: Protected,nodamagetooccur Bounce mode
Remotesense: Compensationupto500mV
Outputisolation: Standard per safety requirements
Forcedloadsharing: Towithin10%ofallsharedoutputs Analogsharingcontrol
Overloadprotection(OCP): 105%to125%
120%to170%
Mainoutput
5Vsboutput
Overvoltageprotection(OVP): 125%to145%
110%to125%
12Voutput
5Vsboutput
Overtempprotection: 10-15°Cabovesafeoperatingarea BothPFCandoutputconvertermonitored
FanFaultProtection: For-Noptiononly.WillshutdownoutputandDC_OK