Long-barrel Inductive Proximity Sensor E2E2 CSM_E2E2_DS_E_2_2 Proximity Sensor with a Long Screw Length * Increased tightening strength. Cable protectors provided as a standard feature. * Increased indicator visibility. A milled section for wrench grip on all models. Be sure to read Safety Precautions on page 9. Ordering Information Sensors DC 2-Wire Models Appearance Shielded Unshielded Sensing distance M12 M18 M30 M12 M18 M30 3 mm 7 mm 10 mm 8 mm 14 mm 20 mm Model Operation mode NO E2E2-X3D1 2M * E2E2-X7D1 2M * E2E2-X10D1 2M * E2E2-X8MD1 2M * E2E2-X14MD1 2M * E2E2-X20MD1 2M * NC E2E2-X3D2 2M E2E2-X7D2 2M E2E2-X10D2 2M E2E2-X8MD2 2M E2E2-X14MD2 2M E2E2-X20MD2 2M * Models with different frequencies are also available. The model numbers are E2E2-X@D15 (example: E2E2-X3D15). DC 3-Wire Models Appearance Shielded Unshielded Sensing distance M12 M18 M30 M12 M18 M30 2 mm 5 mm 10 mm 5 mm 10 mm 18 mm Model Operation mode NO E2E2-X2C1 2M E2E2-X5C1 2M E2E2-X10C1 2M E2E2-X5MC1 2M E2E2-X10MC1 2M E2E2-X18MC1 2M NC E2E2-X2C2 2M E2E2-X5C2 2M E2E2-X10C2 2M E2E2-X5MC2 2M E2E2-X10MC2 2M E2E2-X18MC2 2M AC 2-Wire Models Appearance Shielded Unshielded Sensing distance M12 M18 M30 M12 M18 M30 2 mm 5 mm 10 mm 5 mm 10 mm 18 mm Model Operation mode NO E2E2-X2Y1 2M E2E2-X5Y1 2M E2E2-X10Y1 2M E2E2-X5MY1 2M E2E2-X10MY1 2M E2E2-X18MY1 2M NC E2E2-X2Y2 2M E2E2-X5Y2 2M E2E2-X10Y2 2M E2E2-X5MY2 2M E2E2-X10MY2 2M E2E2-X18MY2 2M 1 E2E2 Accessories (Order Separately) Mounting Brackets Protective Covers Sputter Protective Covers Ratings and Specifications E2E2-X@D@ DC 2-Wire Models Size Shielding Item Model Sensing distance M12 Shielded E2E2-X3D@ M18 Unshielded E2E2-X8MD@ Shielded E2E2-X7D@ M30 Unshielded E2E2-X14MD@ Shielded E2E2-X10D@ Unshielded E2E2-X20MD@ 3 mm10% 8 mm10% 7 mm10% 14 mm10% 10 mm10% 20 mm10% Set distance *1 0 to 2.4 mm 0 to 6.4 mm 0 to 5.6 mm 0 to 11.2 mm 0 to 8 mm 0 to 16 mm Differential travel 10% max. of sensing distance Sensing object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 5.) Standard sensing object Iron, Iron, Iron, Iron, Iron, Iron, 12 x 12 x 1 mm 30 x 30 x 1 mm 18 x 18 x 1 mm 30 x 30 x 1 mm 30 x 30 x 1 mm 54 x 54 x 1 mm Response frequency *2 1 kHz Power supply voltage (operating voltage range) 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. Leakage current 0.8 mA max. Control output Switching capacity 800 Hz 500 Hz 400 Hz 100 Hz 3 to 100 mA Residual voltage 3 V max. (Load current: 100 mA, Cable length: 2 m) Indicators D1 Models: Operation indicator (red) and setting indicator (green) D2 Models: Operation indicator (red) Operation mode (with sensing object approaching) D1 Models: NO Refer to the timing charts under I/O Circuit Diagrams on page 8 for details. D2 Models: NC Protection circuits Surge absorber, Load short-circuit protection Ambient temperature Operating/Storage: -25 to 70C (with no icing or condensation) Ambient humidity Operating/Storage: 35% to 95% (with no condensation) Temperature influence 10% max. of sensing distance at 23C in the temperature range of -25 to 70C Voltage influence 1% max. of sensing distance at rated voltage in the rated voltage 15% range Insulation resistance 50 M min. (at 500 VDC) between current-carrying parts and case Dielectric strength 1000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case Vibration resistance (destruction) 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions Shock resistance (destruction) 1,000 m/s2 10 times each in X, Y, and Z directions Degree of protection IEC IP67, in-house standard for oil resistance Connection method Pre-wired Models (Standard cable length: 2 m) Weight (packed state) Approx. 65 g Case Materials Approx. 150 g Approx. 210 g Brass Sensing surface PBT Clamping nuts Nickel-plated brass Toothed washer Zinc-plated iron Accessories Instruction sheet *1. Use the E2E2 within the range in which the setting indicator (green LED) is ON (except D2 Models). *2. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance. 2 E2E2 E2E2-X@C@ DC 3-Wire Models Size Shielding Item Model M12 M18 M30 Shielded Unshielded Shielded Unshielded Shielded Unshielded E2E2-X2C@ E2E2-X5MC@ E2E2-X5C@ E2E2-X10MC@ E2E2-X10C@ E2E2-X18MC@ Sensing distance 2 mm10% 5 mm10% 5 mm10% 10 mm10% 10 mm10% 18 mm10% Set distance 0 to 1.6 mm 0 to 4 mm 0 to 4 mm 0 to 8 mm 0 to 8 mm 0 to 14 mm Differential travel 10% max. of sensing distance Sensing object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 5.) Standard sensing object Iron, Iron, Iron, Iron, Iron, Iron, 12 x 12 x 1 mm 15 x 15 x 1 mm 18 x 18 x 1 mm 30 x 30 x 1 mm 30 x 30 x 1 mm 54 x 54 x 1 mm Response frequency *1 1.5 kHz Power supply voltage (operating voltage range) *2 12 to 24 VDC (10 to 55 VDC), ripple (p-p): 10% max. Leakage current 13 mA max. Control output Load current 400 Hz 600 Hz 200 Hz 400 Hz 100 Hz NPN open-collector output, 200 mA max. (55 VDC max.) Residual voltage 2 V max. (Load current: 200 mA, Cable length: 2 m) Indicators Operation indicator (red) Operation mode (with sensing object approaching) C1 Models: NO Refer to the timing charts under I/O Circuit Diagrams on page 8 for details. C2 Models: NC Protection circuits Reverse polarity protection, Surge absorber, Load short-circuit protection Ambient temperature Operating/Storage: -40 to 85C (with no icing or condensation) Ambient humidity Operating/Storage: 35% to 95% (with no condensation) Temperature influence 15% max. of sensing distance at 23C in the temperature range of -40 to 85C 10% max. of sensing distance at 23C in the temperature range of -25 to 70C Voltage influence 1% max. of sensing distance at rated voltage in the rated voltage 15% range Insulation resistance 50 M min. (at 500 VDC) between current-carrying parts and case Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between current carry parts and case Vibration resistance (destruction) 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions Shock resistance (destruction) 1,000 m/s2 10 times each in X, Y, and Z directions Degree of protection IEC IP67, in-house standard for oil resistance Connection method Pre-wired Models (Standard cable length: 2 m) and Connector Models Weight (packed state) Approx. 75 g Case Materials Approx. 160 g Approx. 220 g Brass Sensing surface PBT Clamping nuts Nickel-plated brass Toothed washer Zinc-plated iron Accessories Instruction sheet *1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance. *2. A full-wave rectification power supply of 24 VDC 20% (average value) can be used. 3 E2E2 E2E2-X@Y@ AC 2-Wire Models Size Shielding Item Model M12 M18 M30 Shielded Unshielded Shielded Unshielded Shielded Unshielded E2E2-X2Y@ E2E2-X5MY@ E2E2-X5Y@ E2E2-X10MY@ E2E2-X10Y@ E2E2-X18MY@ Sensing distance 2 mm10% 5 mm10% 5 mm10% 10 mm10% 10 mm10% 18 mm10% Set distance 0 to 1.6 mm 0 to 4 mm 0 to 4 mm 0 to 8 mm 0 to 8 mm 0 to 14 mm Differential travel 10% max. of sensing distance Sensing object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 5.) Standard sensing object Iron, Iron, Iron, Iron, Iron, Iron, 12 x 12 x 1 mm 15 x 15 x 1 mm 18 x 18 x 1 mm 30 x 30 x 1 mm 30 x 30 x 1 mm 54 x 54 x 1 mm Response frequency 25 Hz Power supply voltage (operating voltage range) *1 24 to 240 VAC (20 to 264 VAC), 50/60 Hz Leakage current 1.7 mA max. Control output Load current *2 5 to 200 mA 5 to 300 mA Residual voltage Refer to Engineering Data on page 5. Indicators Operation indicator (red) Operation mode (with sensing object approaching) Y1 Models: NO Refer to the timing charts under I/O Circuit Diagrams on page 8 for details. Y2 Models: NC Ambient temperature *1, 2 Operating/Storage: -40 to 85C (with no icing or condensation) Ambient humidity Operating/Storage: 35% to 95% (with no condensation) Temperature influence 15% max. of sensing distance at 23C in the temperature range of -40 to 85C, 10% max. of sensing distance at 23C in the temperature range of -25 to 70C Voltage influence 1% max. of sensing distance at rated voltage in the rated voltage 15% range Insulation resistance 50 M min. (at 500 VDC) between current-carrying parts and case Dielectric strength 4,000 VAC, 50/60 Hz for 1 minute between current carry parts and case Vibration resistance (destruction) 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions Shock resistance (destruction) 1,000 m/s2 10 times each in X, Y, and Z directions Degree of protection IEC IP67, in-house standard for oil resistance Connection method Pre-wired Models (Standard cable length: 2 m) and Connector Models Weight (packed state) Approx. 65 g Case Materials Approx. 150 g Approx. 210 g Brass Sensing surface PBT Clamping nuts Toothed washer Accessories Nickel-plated brass Zinc-plated iron Instruction sheet *1. When supplying 24 VAC to any of the above models, make sure that the operating ambient temperature range is at least -25C to 85C. *2. When using an M18 or M30 Connector Model at an ambient temperature between 70 and 85C, make sure that the Sensor has a control output (load current) of 5 to 200 mA max. 4 E2E2 Engineering Data (Typical) E2E2-X@C@/-X@Y@ 12 Distance X (mm) Distance X (mm) Sensing Area Shielded Models E2E2-X@D@ E2E2-X10 10 8 12 E2E2-X10 10 Y 8 X E2E2-X7 6 6 E2E2-X5 4 4 Y E2E2 -X2 E2E2-X3 X 2 0 -20 2 -15 -10 -5 0 5 10 15 0 -15 20 -10 -5 0 5 Distance Y (mm) 25 20 30 Y X 25 20 E2E2 -X20M 15 E2E2-X18M 15 E2E2 -X14M 10 X E2E2-X10M 10 E2E2 -X8M Y E2E2-X5M 5 0 -30 5 -20 -10 0 10 20 0 -30 30 -20 -10 0 10 Distance Y (mm) Leakage Current E2E2-X@D@ 20 30 Distance Y (mm) Residual Output Voltage E2E2-X@D@ 1.0 0.8 0.6 Residual output voltage (V) E2E2-X@Y@ Leakage current (mA) Leakage current (mA) 15 E2E2-X@MC@/-X@MY@ 30 Distance X (mm) Distance X (mm) Unshielded Models E2E2-X@MD@ 10 Distance Y (mm) 1.4 1.2 1.0 0.8 0.4 0.6 6 5 4 3 Protective resistance 0.4 mA 0.2 0.2 0 5 10 15 20 25 30 Power supply voltage (V) 0 2 AC power V Proximity Sensor (OFF) 50 100 150 200 250 300 Power supply voltage (V) 1 3 5 10 30 50 100 Load current (mA) 5 E2E2 30 E2E2-X@Y@ 25 20 at 100 VAC 120 Residual output voltage 100 ON 80 Residual output voltage 60 15 VL 30 50 OFF 300 500 100 0 40 Residual load voltage 1 3 5 10 30 50 100 t = 1 mm 3 Iron 0 1 3 5 10 30 50 8 @d X 7 OFF 300 500 100 Load current (mA) E2E2-X10D@ t = 1 mm Distance X (mm) X 3.5 Distance (mm) Distance X (mm) Influence of Sensing Object Size and Material E2E2-X3D@ E2E2-X7D@ @d Residual load voltage OFF 300 500 Load current (mA) Load current (mA) 4 200 VAC 80 20 Residual load voltage 10 VL A 24 VAC 5 5 160 120 40 A 3 ON 100 VAC A 1 Residual output voltage 200 V VL V 0 at 200 VAC 240 V ON 10 E2E2-X@Y@ Load voltage VL (V) at 24 VAC Load voltage VL (V) Load voltage VL (V) E2E2-X@Y@ Iron 6 12 @d X t = 1 mm Iron 10 8 2.5 5 Stainless steel (SUS304) 2 Stainless steel (SUS304) 4 6 Stainless steel (SUS304) 4 Brass Aluminum Copper Brass 1.5 Brass 3 Aluminum Copper 1 Aluminum Copper 2 2 0.5 5 10 15 20 25 30 35 40 0 10 20 Side length of sensing object d (mm) 12 @d X 40 t = 1 mm 10 8 0 50 E2E2-X14MD@ Distance X (mm) Distance X (mm) E2E2-X8MD@ 30 10 20 25 @d X 30 40 50 70 E2E2-X20MD@ t = 1 mm 20 25 @d X t = 1 mm 20 Iron Iron 15 15 Iron 6 Stainless steel (SUS304) 10 Brass Aluminum Copper 2 10 20 30 40 50 60 Brass Aluminum Copper 5 70 Side length of sensing object d (mm) 0 Stainless steel (SUS304) Stainless steel (SUS304) 4 0 60 Side length of sensing object d (mm) Side length of sensing object d (mm) Distance X (mm) 0 1 10 20 30 40 50 60 10 Brass Aluminum Copper 5 70 Side length of sensing object d (mm) 0 10 20 30 40 50 60 70 80 90 100 Side length of sensing object d (mm) 6 E2E2 @d X E2E2-X5C@/-X5Y@ t = 1 mm Iron 2 7 @d t = 1 mm X 6 E2E2-X10C@/-X10Y@ Distance X (mm) 2.5 Distance X (mm) Distance X (mm) E2E2-X2C@/-X2Y@ Iron 5 12 @d X t = 1 mm Iron 10 8 Stainless steel (SUS304) Stainless steel (SUS304) 1.5 4 Stainless steel (SUS304) 6 3 1 Brass Brass Brass Aluminum Aluminum Aluminum 0.5 4 2 2 1 5 10 15 20 0 25 10 7 6 @d X 30 40 50 E2E2-X10MC@/-X10MY@ Distance X (mm) Distance X (mm) E2E2-X5MC@/-X5MY@ 20 t = 1 mm Iron 5 0 10 20 Side length of sensing object d (mm) Side length of sensing object d (mm) 12 @d X 30 40 50 60 Side length of sensing object d (mm) E2E2-X18MC@/-X18MY@ t = 1 mm Iron 10 Distance X (mm) 0 25 @d X t = 1 mm 20 Iron 8 15 4 Stainless steel (SUS304) Stainless steel (SUS304) Stainless steel (SUS304) 6 3 10 2 Aluminum Aluminum 2 1 0 10 20 30 40 50 Side length of sensing object d (mm) 0 Brass Brass 4 Brass 10 20 30 40 50 60 Side length of sensing object d (mm) Aluminum 5 0 20 40 60 80 100 Side length of sensing object d (mm) 7 E2E2 I/O Circuit Diagrams DC 2-Wire Models Operation mode Model Timing Charts Non-sensing area Output circuit Unstable Set position sensing Stable sensing area area Proximity Sensor NO E2E2-X3D1 E2E2-X7D1 E2E2-X10D1 E2E2-X8MD1 E2E2-X14MD1 E2E2-X20MD1 Sensing object (%) 100 80 Rated sensing distance 0 ON Setting indicator OFF (green) ON Operation OFF indicator (red) ON Control output OFF Non-sensing area Brown Load +V Proximity Sensor main circuit Blue Stable sensing area 0V Proximity Sensor NC E2E2-X3D2 E2E2-X7D2 E2E2-X10D2 E2E2-X8MD2 E2E2-X14MD2 E2E2-X20MD2 Sensing object (%) Note: The load can be connected to either the +V or 0 V side. 100 0 Rated sensing distance ON Operation OFF indicator (red) ON Control output OFF DC 3-Wire Models Operation mode NO NC Model E2E2-X2C1 E2E2-X5C1 E2E2-X10C1 E2E2-X5MC1 E2E2-X10MC1 E2E2-X18MC1 E2E2-X2C2 E2E2-X5C2 E2E2-X10C2 E2E2-X5MC2 E2E2-X10MC2 E2E2-X18MC2 Timing Charts Sensing object Present Not present Operation indicator (red) OFF Present Not present Operation indicator (red) Control output Brown ON +V 100 OFF Load ON Control output Sensing object Output circuit Proximity Sensor main circuit Black Blue 0V ON OFF ON OFF 8 E2E2 AC 2-Wire Models Operation mode NO NC Model Timing Charts E2E2-X2Y1 E2E2-X5Y1 E2E2-X10Y1 E2E2-X5MY1 E2E2-X10MY1 E2E2-X18MY1 E2E2-X2Y2 E2E2-X5Y2 E2E2-X10Y2 E2E2-X5MY2 E2E2-X10MY2 E2E2-X18MY2 Sensing object Present Not present ON Operation indicator (red) Brown OFF Load ON Control output Sensing object Output circuit Proximity Sensor main circuit OFF Present Not present Operation indicator (red) Control output Blue ON OFF ON OFF Safety Precautions WARNING This product is not designed or rated for ensuring safety of persons either directly or indirectly. Do not use it for such purposes. Precautions for Correct Use Do not use this product under ambient conditions that exceed the ratings. Design Influence of Surrounding Metal When mounting the Sensor within a metal panel, ensure that the clearances given in the following table are maintained. l n m d dia. m D l (Unit: mm) Model Item Shielded DC 2-Wire Models E2E2-X@D@ Unshielded Shielded DC 3-Wire Models E2E2-X@C@ AC 2-Wire Models E2E2-X@Y@ Unshielded l d D m n l d D m n l d D m n l d D m n M12 0 12 0 8 18 15 40 15 20 40 0 12 0 8 18 15 40 15 20 36 M18 0 18 0 20 27 22 70 22 40 70 0 18 0 20 27 22 55 22 40 54 M30 0 30 0 40 45 30 90 30 70 90 0 30 0 40 45 30 90 30 70 90 9 E2E2 Mutual Interference When installing Sensors face-to-face or side-by-side, ensure that the minimum distances given in the following table are maintained. B Size A Mutual Interference (Unit: mm) Model Item M12 30 (20) M18 50 (30) M30 100 (50) B 20 (12) 35 (18) 70 (35) A 120 (60) 200 (100) 300 (100) B 100 (50) 110 (60) 200 (100) A B A B 30 20 120 100 50 35 200 110 100 70 300 200 A Shielded DC 2-Wire Models E2E2-X@D@ Unshielded DC 3-Wire Models E2E2-X@C@ AC 2-Wire Models E2E2-X@Y@ Relationship between Sizes and Models Shielded Unshielded Note: Values in parentheses apply to Sensors operating at different frequencies. Model E2E2-X3D@ Shielded E2E2-X2C@ E2E2-X2Y@ M12 E2E2-X8MD@ Unshielded E2E2-X5MC@ E2E2-X5MY@ E2E2-X7D@ Shielded E2E2-X5C@ E2E2-X5Y@ M18 E2E2-X14MD@ Unshielded E2E2-X10MC@ E2E2-X10MY@ E2E2-X10D@ Shielded E2E2-X10C@ E2E2-X10Y@ M30 E2E2-X20MD@ Unshielded E2E2-X18MC@ E2E2-X18MY@ Mounting Tightening Torque Do not tighten the nut with excessive force. A washer must be used with the nut. The following strengths assume washers are being used. Model Torque M12 M18 M30 30 N*m 70 N*m 180 N*m 10 E2E2 (Unit: mm) Dimensions Unless otherwise specified, the tolerance class IT16 is used for dimensions in this data sheet. Shielded Unshielded E2E2-X3D@/E2E2-X2C@/E2E2-X2Y@ 60 21 dia. 17 E2E2-X8MD@/E2E2-X5MC@/E2E2-X5MY@ 9 60 21 dia. 17 55 4 10 9 55 7 10 4 9 dia. *1 *1 Indicators *2 M12 x 1 Two clamping nuts Toothed washer *1. 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.3 mm), Standard length: 2 m 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.3 mm), Standard length: 2 m The cable can be extended to up to 200 m (Separate metal conduit.) *2. D Models: Operation indicator (red) and setting indicator (green), C/Y Models: Operation indicator (red) *1. 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.3 mm), Standard length: 2 m 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.3 mm), Standard length: 2 m The cable can be extended to up to 200 m (Separate metal conduit.) *2. D Models: Operation indicator (red) and setting indicator (green), C/Y Models: Operation indicator (red) E2E2-X7D@/E2E2-X5C@/E2E2-X5Y@ E2E2-X14MD@/E2E2-X10MC@/E2E2-X10MY@ 65 29 dia. 24 Indicators *2 M12 x 1 Two clamping nuts Toothed washer 65 12 29 dia. 24 60 4 10 12 60 10 4 10 14.8 dia. *1 *1 Indicators *2 M18 x 1 Two clamping nuts Toothed washer E2E2-X10D@/E2E2-X10C@/E2E2-X10Y@ 42 dia. 36 5 Two clamping nuts Toothed washer *1. 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m 6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m The cable can be extended to up to 200 m (Separate metal conduit.) *2. D Models: Operation indicator (red) and setting indicator (green), C/Y Models: Operation indicator (red) *1. 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m 6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m The cable can be extended to up to 200 m (Separate metal conduit.) *2. D Models: Operation indicator (red) and setting indicator (green), C/Y Models: Operation indicator (red) 70 65 Indicators *2 M18 x 1 E2E2-X20MD@/E2E2-X18MC@/E2E2-X18MY@ 70 12 42 dia. 36 10 12 65 13 5 10 26.8 dia. *1 *1 Indicators *2 M30 x 1.5 Indicators *2 M30 x 1.5 Two clamping nuts Toothed washer Two clamping nuts Toothed washer *1. 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m 6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m The cable can be extended to up to 200 m (Separate metal conduit.) *2. D Models: Operation indicator (red) and setting indicator (green), C/Y Models: Operation indicator (red) *1. 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m 6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m The cable can be extended to up to 200 m (Separate metal conduit.) *2. D Models: Operation indicator (red) and setting indicator (green), C/Y Models: Operation indicator (red) Mounting Hole Dimensions Dimension F (mm) M12 M18 +0.5 12.5 0 +0.5 18.5 0 dia. M30 dia. 30.5 +0.5 0 dia. F Note 1. Two clamping nuts and one toothed washer are provided with each Sensors. 2. The model number is laser-marked on the cable section and milled section. In the interest of product improvement, specifications are subject to change without notice. 11 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: * Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. * Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. * Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2009.1 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2009 All Right Reserved.