Notice for TAIYO YUDEN products Please read this notice before using the TAIYO YUDEN products. REMINDERS Product information in this catalog is as of October 2011. All of the contents specified herein are subject to change without notice due to technical improvements, etc. Therefore, please check for the latest information carefully before practical application or usage of the Products. Please note that Taiyo Yuden Co., Ltd. shall not be responsible for any defects in products or equipment incorporating such products, which are caused under the conditions other than those specified in this catalog or individual specification. Please contact Taiyo Yuden Co., Ltd. for further details of product specifications as the individual specification is available. Please conduct validation and verification of products in actual condition of mounting and operating environment before commercial shipment of the equipment. All electronic components or functional modules listed in this catalog are developed, designed and intended for use in general electronics equipment.(for AV, office automation, household, office supply, information service, telecommunications, (such as mobile phone or PC) etc.). Before incorporating the components or devices into any equipment in the field such as transportation,( automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network (telephone exchange, base station) etc. which may have direct influence to harm or injure a human body, please contact Taiyo Yuden Co., Ltd. for more detail in advance. Do not incorporate the products into any equipment in fields such as aerospace, aviation, nuclear control, submarine system, military, etc. where higher safety and reliability are especially required. In addition, even electronic components or functional modules that are used for the general electronic equipment, if the equipment or the electric circuit require high safety or reliability function or performances, a sufficient reliability evaluation check for safety shall be performed before commercial shipment and moreover, due consideration to install a protective circuit is strongly recommended at customer's design stage. The contents of this catalog are applicable to the products which are purchased from our sales offices or distributors (so called"TAIYO YUDEN' s official sales channel"). It is only applicable to the products purchased from any of TAIYO YUDEN's official sales channel. Please note that Taiyo Yuden Co., Ltd. shall have no responsibility for any controversies or disputes that may occur in connection with a third party's intellectual property rights and other related rights arising from your usage of products in this catalog. Taiyo Yuden Co., Ltd. grants no license for such rights. Caution for export Certain items in this catalog may require specific procedures for export according to"Foreign Exchange and Foreign Trade Control Law"of Japan,"U.S. Export Administration Regulations", and other applicable regulations. Should you have any question or inquiry on this matter, please contact our sales staff. 12 notice_e-01 RADIAL LEADED INDUCTORS WAVE FEATURES APPLICATIONS The LHL08~LHL16 series radial inductors are encapsulated in a resin housing which adds to the stability of the mounted part on a printed circuit board. Ideal for use as a power choke coil in general household appliances (TVS, PDPTV, LCDTV, DVD, etc) and industrial equipment. Can also be used as a peaking coil in filtering applications. The LHL08/LHL10/LHL13/LHL16 series are for high current applications. For DC/DC converter (LCD TV, PDP TV, CTV, DVD etc.) (LHLC Series) The LHLP10/LHLP12/LHLP16 series are shielded type for high current applications. LHLP10 series is also available in packaging. LHLC08/LHLC10 series which are encapsulated in a resin housing, are radial leaded inductor for high current applications. OPERATING TEMP. 25105Including self-generated heat ORDERING CODE L H L 0 Type LH Radial leaded inductor 8 T B 1 0 Configuration L Standard type Taping available LP Shielded type Bulk LC High current type External dimensions mm max 08 9.0 10 11.0 12 13.0 13 14.0 16 17.0 Blank space K 1 NB TB Packaging Code Bulk (LHL) Ammo packaging (LHL) Nominal Inductance (H) Inductance Tolerances () J 5 K 10 M 20 N 30 example 1R0 150 102 1.0 15 1000 R=Decimal point Internal code Standard product Blank space EXTERNAL DIMENSIONS/STANDARD QUANTITY Type D H2 F d 9.0 max. 0.354 max. 11.0 max. 0.433 max. 14.0 max. 0.551 max. 17.0 max. 0.669 max. 11.0 max. 0.433 max. 13.0 max. 0.512 max. 17.0 max. 0.669 max. 9.5 max. 0.374 max. 14.0 max. 0.551 max. 17.0 max. 0.669 max. 21.0 max. 0.827 max. 11.0 max. 0.433 max. 16.0 max. 0.624 max. 19.0 max. 0.741 max. 5.01.0 0.1970.039 5.01.0 0.1970.039 5.01.0 0.1970.039 5.01.0 0.1970.039 5.01.0 0.1970.039 5.01.0 0.1970.039 5.01.0 0.1970.039 5.01.0 0.1970.039 5.01.0 0.1970.039 7.51.0 0.2950.039 7.51.0 0.2950.039 5.01.0 0.1970.039 5.01.0 0.1970.039 7.51.0 0.2950.039 0.60.05 0.0240.002 0.60.05 0.0240.002 0.80.05 0.0310.002 0.80.05 0.0310.002 0.60.05 0.0240.004 0.60.05 0.0240.004 0.80.05 0.0310.004 Fig. LHL08 LHL10 LHL13 LHL16 LHLP10 LHLP12 LHLP16 Standard Quantity (pcs) Taped Box Bulk 100 1000 50 500 25 500 500 250 500 200 300 200 Unitmminch LH type Type Fig. D H2 F d Standard Quantity (pcs) Taped Bulk LHLC08 9.0max 0.354max 9.5max 5.01.0 0.374max 0.1970.039 5.01.0 0.1970.039 0.60.05 0.0240.002 100 LHLC10 11.0max 0.433max 14.0max 5.01.0 0.551max 0.1970.039 5.01.0 0.1970.039 0.60.05 0.0240.002 50 1000 500 Unitmm inch This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. 112 12 leaded_i02_e-01 AVAILABLE INDUCTANCE RANGE Type Range LHL08 LHL10 LHL13 LHL16 LHLP10 LHLP12 LHLP16 Type Range 1.0 1.0 3.3 10 10 10 47 10 15 100 1.0m 1.0m 10m 10m 33m 1.0m 10 100 1.0m 1.0m 10m 10m 0.013 LHLC10 Imax[A] Rdc max[] max[] InductanceH InductanceH 1.0 LHLC08 0.1 Rdc 0.22 1.0 Imax[A] 5.4 3.3 0.041 2.9 0.034 0.32 1.0 0.18 1.5 2.7 0.35 1.8 0.48 0.11 19.0 0.14 32.0 3.6 33m 0.038 150m 150m PART NUMBERS LHL08 Ordering code LHL081R0N LHL081R5M LHL082R2M LHL082R7M LHL083R3M LHL083R9M LHL084R7M LHL085R6M LHL086R8M LHL088R2M LHL08100K LHL08120K LHL08150K LHL08180K LHL08220K LHL08270K LHL08330K LHL08390K LHL08470K LHL08560K LHL08680K LHL08820K LHL08101K LHL08121K LHL08151K LHL08181K LHL08221K LHL08271K LHL08331K LHL08391K LHL08471K LHL08561K LHL08681K LHL08821K LHL08102J LHL08122J LHL08152J LHL08182J LHL08222J LHL08272J LHL08332J LHL08392J LHL08472J LHL08562J LHL08682J LHL08822J LHL08103J LHL08123J LHL08153J LHL08183J LHL08223J LHL08273J LHL08333J EHS (Environmental Hazardous Substances) RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS Inductance [H] Inductance Tolerance 1.0 1.5 2.2 2.7 3.3 3.9 4.7 5.6 6.8 8.2 10 12 15 18 22 27 33 39 47 56 68 82 100 120 150 180 220 270 330 390 470 560 680 820 1000 1200 1500 1800 2200 2700 3300 3900 4700 5600 6800 8200 10000 12000 15000 18000 22000 27000 33000 30 20 Q min. 40 65 50 40 35 10 25 20 35 25 20 25 30 55 45 55 5 65 60 Self-resonant frequency MHz(min.) 76 65 56 48 41 33 30 23 21 19 17 16 13 12 11 10 8.8 8.4 8.2 7.9 7.0 6.5 5.7 5.2 4.7 4.2 3.7 3.5 3.2 2.9 2.4 2.2 2.0 1.6 1.5 1.4 1.3 1.2 1.1 1.0 0.85 0.78 0.68 0.62 0.61 0.60 0.48 0.44 0.35 0.30 0.28 0.25 0.23 DC Resistance [] (max.) Rated current A(max.) 0.013 0.014 0.017 0.019 0.021 0.024 0.025 0.028 0.030 0.034 0.041 0.044 0.053 0.060 0.068 0.091 0.10 0.12 0.15 0.17 0.20 0.22 0.32 0.36 0.41 0.66 0.73 0.85 0.97 1.1 1.3 1.5 1.8 2.3 2.7 3.2 4.1 4.8 5.6 7.5 8.5 9.7 14 16 18 20 32 36 62 72 82 90 100 4.7 4.4 4.1 3.5 3.2 3.1 3.0 2.9 2.8 2.5 2.4 2.3 2.0 1.9 1.8 1.5 1.4 1.3 1.2 1.1 1.0 0.90 0.79 0.70 0.64 0.60 0.53 0.51 0.44 0.41 0.38 0.35 0.32 0.30 0.25 0.22 0.20 0.19 0.16 0.15 0.14 0.11 0.10 0.093 0.092 0.084 0.070 0.064 0.051 0.048 0.044 0.042 0.040 Measuring frequency MHz 7.96 LEADED INDUCTORS INDUCTORS 240.0 100m 100m 2.52 0.796 0.252 L:1kHz Q:0.0796 Please specify the packaging code. (TB: Taping, NB: Bulk) This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. leaded_i02_e-01 12 113 PART NUMBERS LHL10 Ordering code LHL103R3M LHL103R9M LHL104R7M LHL105R6M LHL106R8M LHL108R2M LHL10100K LHL10120K LHL10150K LHL10180K LHL10220K LHL10270K LHL10330K LHL10390K LHL10470K LHL10560K LHL10680K LHL10820K LHL103R3M LHL103R9M LHL104R7M LHL105R6M LHL106R8M LHL108R2M LHL10100K LHL10120K LHL10150K LHL10180K LHL10220K LHL10270K LHL10330K LHL10390K LHL10470K LHL10560K LHL10680K LHL10820K LHL10101K LHL10121K LHL10151K LHL10181K LHL10221K LHL10271K LHL10331K LHL10391K LHL10471K LHL10561K LHL10681K LHL10821K LHL10102J LHL10122J LHL10152J LHL10182J LHL10222J LHL10272J LHL10332J LHL10392J LHL10472J LHL10562J LHL10682J LHL10822J LHL10103J LHL10123J LHL10153J LHL10183J LHL10223J LHL10273J LHL10333J LHL10393J LHL10473J LHL10563J LHL10683J LHL10823J LHL10104J LHL10124J LHL10154J EHS (Environmental Hazardous Substances) RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS Inductance [H] 3.3 3.9 4.7 5.6 6.8 8.2 10 12 15 18 22 27 33 39 47 56 68 82 3.3 3.9 4.7 5.6 6.8 8.2 10 12 15 18 22 27 33 39 47 56 68 82 100 120 150 180 220 270 330 390 470 560 680 820 1000 1200 1500 1800 2200 2700 3300 3900 4700 5600 6800 8200 10000 12000 15000 18000 22000 27000 33000 39000 47000 56000 68000 82000 100000 120000 150000 Inductance Tolerance 20 Q min. Self-resonant frequency MHz(min.) DC Resistance [] (max.) Rated current A(max.) 46 40 38 34 30 24 19 16 12 9.2 8.6 7.1 6.8 6.7 6.2 5.2 4.9 4.7 46 40 38 34 30 24 19 16 12 9.2 8.6 7.1 6.8 6.7 6.2 5.2 4.9 4.7 3.8 3.2 2.9 2.6 2.3 2.1 2.0 1.8 1.7 1.5 1.4 1.3 1.2 0.87 0.83 0.75 0.70 0.67 0.56 0.54 0.49 0.41 0.38 0.36 0.29 0.27 0.24 0.21 0.20 0.15 0.14 0.13 0.12 0.10 0.095 0.088 0.085 0.070 0.069 0.019 0.022 0.024 0.025 0.028 0.031 0.034 0.038 0.042 0.046 0.061 0.069 0.078 0.085 0.093 0.10 0.12 0.13 0.019 0.022 0.024 0.025 0.028 0.031 0.034 0.038 0.042 0.046 0.061 0.069 0.078 0.085 0.093 0.10 0.12 0.13 0.18 0.25 0.29 0.40 0.44 0.50 0.56 0.62 0.84 0.93 1.0 1.4 1.8 2.3 2.7 3.0 3.9 4.3 5.8 6.4 7.1 9.0 10 12 19 21 34 38 43 67 76 84 96 170 200 210 240 260 300 4.2 4.1 4.0 3.8 3.4 3.3 3.2 2.8 2.6 2.4 2.1 2.0 1.9 1.8 1.7 1.6 1.5 1.4 4.2 4.1 4.0 3.8 3.4 3.3 3.2 2.8 2.6 2.4 2.1 2.0 1.9 1.8 1.7 1.6 1.5 1.4 1.2 1.0 0.95 0.80 0.75 0.70 0.68 0.63 0.57 0.52 0.48 0.42 0.41 0.33 0.30 0.29 0.25 0.24 0.21 0.20 0.19 0.17 0.16 0.15 0.12 0.11 0.090 0.081 0.075 0.060 0.056 0.053 0.050 0.036 0.035 0.033 0.031 0.030 0.028 50 90 10 60 50 40 20 50 90 10 60 50 40 40 10 30 50 5 60 40 30 Measuring frequency MHz 7.96 2.52 7.96 2.52 0.796 0.252 L:1kHz Q:0.0796 L:1kHz Q:0.0252 Please specify the packaging code. (TB: Taping, NB: Bulk) This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. 114 12 leaded_i02_e-01 PART NUMBERS LHL13 LHL13103J RoHS Inductance [H] 10 15 22 33 47 68 100 150 220 330 470 680 1000 1500 2200 3300 4700 6800 Inductance Tolerance 30 Self-resonant frequency MHz(min.) 19 12 7.6 6.9 5.6 4.4 3.3 2.6 2.2 1.8 1.5 1.2 1.0 0.83 0.70 0.60 0.43 0.38 70 0.30 Q min. 140 100 70 10 50 40 30 40 5 10000 Measuring frequency MHz DC Resistance [] (max.) Rated current A(max.) 0.023 0.028 0.035 0.043 0.052 0.070 0.12 0.19 0.23 0.35 0.43 0.61 1.2 1.8 2.2 3.4 4.7 5.6 4.5 4.0 3.4 3.2 2.8 2.4 2.0 1.5 1.3 1.1 0.90 0.80 0.60 0.45 0.40 0.33 0.28 0.25 10 0.19 L:1kHz Q:0.0796MHz DC Resistance [] (max.) Rated current A(max.) Measuring frequency MHz 0.046 0.054 0.077 0.11 0.15 0.21 0.28 0.35 0.74 0.93 1.4 2.2 2.6 3.9 3.7 3.3 2.9 2.4 2.0 1.5 1.3 1.1 0.86 0.75 0.60 0.50 0.40 0.33 7.3 0.25 2.52 0.796 0.252 Please specify the packaging code. (TB: Taping, NB: Bulk) LHL16 LHL16470K LHL16680K LHL16101K LHL16151K LHL16221K LHL16331K LHL16471K LHL16681K LHL16102J LHL16152J LHL16222J LHL16332J LHL16472J LHL16682J EHS (Environmental Hazardous Substances) RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS LHL16103J RoHS Ordering code Inductance [H] 47 68 100 150 220 330 470 680 1000 1500 2200 3300 4700 6800 Inductance Tolerance Self-resonant frequency MHz(min.) 4.5 3.9 2.7 2.3 1.9 1.6 1.4 1.2 0.84 0.69 0.56 0.49 0.41 0.35 Q min. 70 10 60 40 30 20 5 10000 70 0.26 2.52 0.796 LEADED INDUCTORS INDUCTORS LHL13100K LHL13150K LHL13220K LHL13330K LHL13470K LHL13680K LHL13101K LHL13151K LHL13221K LHL13331K LHL13471K LHL13681K LHL13102J LHL13152J LHL13222J LHL13332J LHL13472J LHL13682J EHS (Environmental Hazardous Substances) RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS Ordering code 0.252 L:1KHz Q:0.0796MHz Please specify the packaging code. (TB: Taping, NB: Bulk) LHLP10 Ordering code LHLP10100M LHLP10150M LHLP10220M LHLP10330M LHLP10470M LHLP10680M LHLP10101K LHLP10151K LHLP10221K LHLP10331K LHLP10471K LHLP10681K LHLP10102K EHS (Environmental Nominal Inductance Hazardous [H] Substances) RoHS 10 RoHS 15 RoHS 22 RoHS 33 RoHS 47 RoHS 68 RoHS 100 RoHS 150 RoHS 220 RoHS 330 RoHS 470 RoHS 680 RoHS 1000 L Measuring frequency 2.52 0.796 Inductance Tolerance 20 10 0.252 DC Resistance [] (max.) Rated current A(max.) 0.038 0.049 0.075 0.094 0.15 0.23 0.30 0.47 0.70 0.88 1.3 1.9 3.2 2.5 2.2 1.9 1.7 1.3 1.0 0.90 0.78 0.63 0.58 0.46 0.38 0.30 DC Resistance [] (max.) Rated current A(max.) 0.035 0.050 0.070 0.081 0.12 0.16 0.24 0.38 0.46 0.69 1.1 1.8 3.3 2.7 2.4 2.1 1.7 1.6 1.3 0.95 0.89 0.74 0.58 0.46 Please specify the packaging code. (TB: Taping, NB: Bulk) LHLP12NB Ordering code LHLP12NB150M LHLP12NB220M LHLP12NB330M LHLP12NB470M LHLP12NB680M LHLP12NB101K LHLP12NB151K LHLP12NB221K LHLP12NB331K LHLP12NB471K LHLP12NB681K LHLP12NB102K EHS (Environmental Nominal Inductance Hazardous [H] Substances) RoHS 15 RoHS 22 RoHS 33 RoHS 47 RoHS 68 RoHS 100 RoHS 150 RoHS 220 RoHS 330 RoHS 470 RoHS 680 RoHS 1000 L Measuring frequency 2.52 0.796 0.252 Inductance Tolerance 20 10 This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. leaded_i02_e-01 12 115 PART NUMBERS LHLP16NB Ordering code LHLP16NB100M LHLP16NB150M LHLP16NB220M LHLP16NB330M LHLP16NB470K LHLP16NB680K LHLP16NB101K LHLP16NB151K LHLP16NB221K LHLP16NB331K LHLP16NB471K LHLP16NB681K LHLP16NB102K EHS (Environmental Nominal Inductance Hazardous [H] Substances) RoHS 10 RoHS 15 RoHS 22 RoHS 33 RoHS 47 RoHS 68 RoHS 100 RoHS 150 RoHS 220 RoHS 330 RoHS 470 RoHS 680 RoHS 1000 L Measuring frequency Inductance Tolerance DC Resistance [] (max.) Rated current A(max.) 0.019 0.025 0.027 0.035 0.045 0.062 0.091 0.14 0.20 0.31 0.47 0.58 0.94 5.2 5.1 4.6 4.0 3.4 3.1 2.3 1.9 1.5 1.3 1.0 0.98 0.74 20 1kHz 10 LHLC08 Ordering code LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LC081R0N LC081R5M LC082R2M LC082R7M LC083R3M LC083R9M LC084R7M LC085R6M LC086R8M LC088R2M LC08100K LC08120K LC08150K LC08180K LC08220K LC08270K LC08330K LC08390K LC08470K LC08560K LC08680K LC08820K LC08101K LC08121K LC08151K LC08181K LC08221K LC08271K LC08331K LC08391K LC08471K LC08561K LC08681K LC08821K LC08102J LC08122J LC08152J LC08182J LC08222J LC08272J LC08332J LC08392J LC08472J LC08562J LC08682J LC08822J LC08103J LC08123J LC08153J LC08183J LC08223J LC08273J LC08333J EHS (Environmental Hazardous Substances) RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS Inductance [H] Inductance Tolerance 1.0 1.5 2.2 2.7 3.3 3.9 4.7 5.6 6.8 8.2 10 12 15 18 22 27 33 39 47 56 68 82 100 120 150 180 220 270 330 390 470 560 680 820 1000 1200 1500 1800 2200 2700 3300 3900 4700 5600 6800 8200 10000 12000 15000 18000 22000 27000 33000 30 20 Q (min.) Self-resonant frequency MHz(min.) DC Resistance [] (max.) Rated current A (max.) 76 65 56 48 41 33 30 23 21 19 17 16 13 12 11 10 8.8 8.4 8.2 7.9 7.0 6.5 5.7 5.2 4.7 4.2 3.7 3.5 3.2 2.9 2.4 2.2 2.0 1.6 1.5 1.4 1.3 1.2 1.1 1.0 0.85 0.78 0.68 0.62 0.61 0.60 0.48 0.44 0.35 0.30 0.28 0.25 0.23 0.013 0.014 0.017 0.019 0.021 0.024 0.025 0.028 0.030 0.034 0.041 0.044 0.053 0.060 0.068 0.091 0.10 0.12 0.15 0.17 0.20 0.22 0.32 0.36 0.41 0.66 0.73 0.85 0.97 1.1 1.3 1.5 1.8 2.3 2.7 3.2 4.1 4.8 5.6 7.5 8.5 9.7 14 16 18 20 32 36 62 72 82 90 100 5.4 5.2 4.8 4.2 3.8 3.7 3.6 3.5 3.4 3.0 2.9 2.8 2.6 2.4 2.3 2.0 1.9 1.7 1.5 1.4 1.3 1.2 1.0 0.96 0.88 0.71 0.66 0.63 0.59 0.55 0.49 0.47 0.44 0.38 0.35 0.31 0.29 0.26 0.23 0.21 0.19 0.18 0.16 0.15 0.14 0.13 0.11 0.084 0.068 0.066 0.057 0.054 0.053 40 65 10 50 50 40 35 25 10 20 35 25 20 25 30 55 45 55 5 65 60 Measuring frequency MHz 7.96 2.52 2.52 0.796 0.252 L:1kHz Q:0.0796 Please specify the packaging code. (TB: Taping, NB: Bulk) This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. 116 12 leaded_i02_e-01 PART NUMBERS LHLC10 Ordering code LC103R3M LC103R9M LC104R7M LC105R6M LC106R8M LC108R2M LC10100K LC10120K LC10150K LC10180K LC10220K LC10270K LC10330K LC10390K LC10470K LC10560K LC10680K LC10820K LC10101K LC10121K LC10151K LC10181K LC10221K LC10271K LC10331K LC10391K LC10471K LC10561K LC10681K LC10821K LC10102J LC10122J LC10152J LC10182J LC10222J LC10272J LC10332J LC10392J LC10472J LC10562J LC10682J LC10822J LC10103J LC10123J LC10153J LC10183J LC10223J LC10273J LC10333J LC10393J LC10473J LC10563J LC10683J LC10823J LC10104J LC10124J LC10154J Inductance [H] 3.3 3.9 4.7 5.6 6.8 8.2 10 12 15 18 22 27 33 39 47 56 68 82 100 120 150 180 220 270 330 390 470 560 680 820 1000 1200 1500 1800 2200 2700 3300 3900 4700 5600 6800 8200 10000 12000 15000 18000 22000 27000 33000 39000 47000 56000 68000 82000 100000 120000 150000 Inductance Tolerance 20 Q (min.) Self-resonant frequency MHz(min.) DC Resistance [] (max.) Rated current A (max.) 46 40 38 34 30 24 19 16 12 9.2 8.6 7.1 6.8 6.7 6.2 5.2 4.6 4.7 3.8 3.2 2.9 2.6 2.3 2.1 2.0 1.8 1.7 1.5 1.4 1.3 1.2 0.87 0.83 0.75 0.70 0.67 0.56 0.54 0.49 0.41 0.38 0.36 0.29 0.27 0.24 0.21 0.20 0.15 0.14 0.13 0.12 0.10 0.095 0.088 0.085 0.070 0.069 0.019 0.022 0.024 0.025 0.028 0.031 0.034 0.038 0.042 0.046 0.061 0.069 0.078 0.085 0.093 0.10 0.12 0.13 0.18 0.25 0.29 0.40 0.44 0.50 0.56 0.62 0.84 0.93 1.0 1.4 1.8 2.3 2.7 3.0 3.9 4.3 5.8 6.4 7.1 9.0 10 12 19 21 34 38 43 67 76 84 96 170 200 210 240 260 300 5.0 4.8 4.7 4.5 4.1 3.9 3.6 3.4 3.2 3.0 2.8 2.7 2.6 2.4 2.3 2.1 2.0 1.8 1.5 1.3 1.2 1.0 0.97 0.90 0.86 0.75 0.65 0.61 0.57 0.50 0.48 0.40 0.37 0.36 0.32 0.30 0.26 0.25 0.24 0.21 0.20 0.18 0.14 0.13 0.11 0.10 0.095 0.076 0.068 0.065 0.061 0.045 0.043 0.041 0.038 0.037 0.035 50 90 60 10 50 40 10 30 50 5 60 40 30 Measuring frequency MHz 7.96 2.52 0.796 LEADED INDUCTORS INDUCTORS LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH LH EHS (Environmental Hazardous Substances) RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS RoHS 0.252 L:1kHz Q:0.0796 L:1kHz Q:0.0252 Please specify the packaging code. (TB: Taping, NB: Bulk) This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. leaded_i02_e-01 12 117 ELECTRICAL CHARACTERISTICS DC Bias characteristics LHL08 LHL10 LHL13 LHL16 LHLP10 LHLP12 LHLP16 This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. 118 12 leaded_i02_e-01 ELECTRICAL CHARACTERISTICS DC Bias characteristics Measured by HP4284A LHLC08 100000 333 223 10000 LHLC10 1000000 100000 103 154J 104J 473J 472 223J 222 1000 10000 102 103J 472J 471 222J 221 100 1000 101 102J 471K 470K 221K 220 100 100 101K 470K 4R7 220K 2R2 1 10 100K 1R0 3R3M 0.1 0.01 0.1 1 10 1 0.01 0.1 1 10 Temperature characteristics LEADED INDUCTORS INDUCTORS 10 Q-vs-Frequency characteristics This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. leaded_i02_e-01 12 119 PACKAGING Minimum Quantity Type (EIA) LHL08 Box 500 500 300 200 LHL 08 LHL 10 LHL 13 LHL 16 LHLP10 LHLP12NB LHLP16NB LHLC08 LHLC10 Standard quantity (pcs) Bulk 100 50 25 100 50 Taped 1000 500 500 250 200 1000 500 Bulk dimensions LHL0816 Dimensions F d LHL08 9.0 0.354 9.5 5.01.0 5.01.0 0.60.05 0.374 0.1970.0390.1970.0390.0240.002 LHL10 11.0 0.433 14.0 5.01.0 5.01.0 0.60.05 0.551 0.1970.0390.1970.0390.0240.002 LHL13 14.0 0.551 17.0 7.51.0 5.01.0 0.80.05 0.669 0.2950.0390.1970.0390.0310.002 LHL16 17.0 21.0 7.51.0 5.01.0 0.80.05 0.669 0.827 0.2950.0390.1970.0390.0310.002 Unitmm inch *Measured at the base of the leads. LHLP1016 LHL16 P0 12.70.31 12.70.31 15.00.31 15.00.31 0.5000.012 0.5000.012 0.5910.012 0.5910.012 P1 3.850.7 3.850.7 3.750.7 3.750.7 0.1520.028 0.1520.028 0.1480.028 0.1480.028 P2 6.351.3 6.351.3 7.501.3 7.501.3 0.2500.051 0.2500.051 0.2950.051 0.2950.051 F 5.00.8 0.2 0.1970.031 0.008 5.00.8 0.2 0.1970.031 0.008 7.500.8 7.500.5 0.2 0.2950.020 0.2950.031 0.008 h 0.02.0 0.00.079 0.02.0 0.00.079 0.02.0 0.00.079 0.02.0 0.00.079 W 18.01.0 0.5 0.7090.039 0.020 18.01.0 0.5 0.7090.039 0.020 18.01.0 0.5 0.7090.039 0.020 18.01.0 0.5 0.7090.039 0.020 W0 12.5 min 0.492 min 12.5 min 0.492 min 12.5 min 0.492 min 12.5 min 0.492 min 9.00.5 9.00.5 9.00.5 9.00.5 0.3540.020 0.3540.020 0.3540.020 0.3540.020 3.0 max2 0.118 max W2 D max Hmax 2 LHL13 P W1 Type LHL10 12.71.0 12.71.0 15.01.0 30.01.0 0.5000.039 0.5000.039 0.5910.039 1.180.039 3.0 max2 0.118 max 3.0 max2 0.118 max 3.0 max2 0.118 max D0 4.00.2 4.00.2 4.00.2 4.00.2 0.1580.0080.1580.0080.1580.0080.1580.008 d 0.60.05 0.60.05 0.80.05 0.80.05 0.0240.002 0.0240.0020.0310.0020.0310.002 t 0.60.3 0.60.3 0.60.3 0.60.3 0.0240.012 0.0240.012 0.0240.012 0.0240.012 D1 1.8 0.071 1.8 0.071 1.8 0.071 P3 6.35 0.25 6.35 0.25 7.50 0.25 inch Unitmm 1 Accumulated error for 20 pitches is 1mm. 2 Bonding tape must not protrude from the base tape. LHLP10TB Type Dimensions F D max Hmax 2 d LHLP10 11.0 11.0 5.01.0 5.01.0 0.60.05 0.433 0.433 0.1970.0390.1970.0390.0240.004 LHLP12 13.0 0.512 16.0 5.01.0 5.01.0 0.60.05 0.624 0.1970.0390.1970.0390.0240.004 LHLP16 17.0 0.669 19.0 7.51.0 5.01.0 0.80.05 0.741 0.2950.0390.1970.0390.0310.004 Unitmm inch *Measured at the base of the leads. Type LHL0816 Symbol Dimensions Symbol Dimensions D 11.0 max 0.433 max W 18.01.0 0.5 0.7090.039 0.020 H1 32.0 max 1.26 max W0 12.5 min 0.492 min H 18.02.0 0.0 0.7090.079 0.000 W1 9.00.5 0.3540.020 H2 11.0 max 0.433 max W2 3.0 max2 0.118 max P 12.71.0 0.5000.039 D0 4.00.2 0.1580.008 P0 12.70.31 0.5000.012 d 0.60.05 0.0240.002 P1 3.850.7 0.1520.028 t 0.60.3 0.0240.012 P2 6.351.3 0.2500.051 D1 1.8 0.071 F 5.00.8 0.2 0.1970.031 0.008 P3 6.35 0.25 h 0.02.0 0.00.079 LHLP10 LHL08 D LHL10 LHL13 LHL16 9.0 max 11.0 max 14.0 max 17.0 max 0.354 max 0.433 max 0.551 max 0.669 max H1 30.5 max 1.20 max 34.0 max 1.34 max 37.0 max 1.46 max 41.0 max 1.61 max H 18.02.0 0.0 0.7090.079 0.000 18.02.0 0.0 0.7090.079 0.000 18.02.0 0.0 0.7090.079 0.000 18.02.0 0.0 0.7090.079 0.000 H2 9.5 max 0.374 max 14.0 max 0.551 max 17.0 max 0.669 max 21.0 max 0.827 max Unitmm inch 1 Accumulated error for 20 pitches is 1mm. 2 Bonding tape must not protrude from the base tape. This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. leaded_i02_pack-P1 12 leaded_i02_pack_e-01 PACKAGING LHLC08, LHLC10 Dimensions D H2 (max) F d (max) 9.0 9.5 5.01.0 5.01.0 0.60.05 LHLC08 0.354 0.374 0.1970.0390.1970.0390.0240.002 11.0 14.0 5.01.0 5.01.0 0.60.05 LHLC10 0.433 0.551 0.1970.0390.1970.0390.0240.002 Type *Measured at the base of the leads. Unitmm inch LHLC08 LHLC10 D 9.0max (0.354max 11.0max 0433max H1 30.5max 1.20max 34.0max 1.34max H 18.00.0 0.7090.079 0.000 18.00.0 0.7090.079 0.000 H2 9.5max 0.374max 14.0max 0.551max P 12.71.0 0.5000.039 12.71.0 0.5000.039 P0 12.70.31 0.5000.012 12.70.31 0.5000.012 P1 3.850.7 0.1520.028 3.850.7 0.1520.028 P2 6.351.3 0.2500.051 6.351.3 0.2500.051 F 5.00.2 0.1970.031 0.008 5.00.2 0.1970.031 0.008 h 0.02.0 0.00.079 0.02.0 0.00.079 W 0.7090.039 0.020 0.7090.020 W0 12.5min 0.492min 12.5min 0.492min W1 9.00.5 0.3540.020 9.00.5 0.3540.020 W2 3.0max2 0.118max 3.0max2 0.118max D0 4.00.2 0.1580.008 4.00.2 0.1580.008 d 0.60.05 0.0240.002 0.60.05 0.0240.002 t 0.60.3 0.0240.012 0.60.3 0.0240.012 D1 1.8 0.071 1.8 0.071 P3 6.35 0.25 6.35 0.25 2.0 0.8 18.01.0 0.5 1 Accumulated error for 20 pitches is 1mm. 2 Bonding tape must not protrude from the base tape. 2.0 0.8 18.01.0 0.5 0.039 Unitmm inch This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. leaded_i02_pack-P2 12 leaded_i02_pack_e-01 RELIABILITY DATA 1. Operating temperature Range LA Type CAL45 Type 25105 LHL FBA/FBR 2585 FL05 Type 25105 FL06BT Type Test Method and Remarks LACAFL : Including self-generated heat LHL : Including self-generated heat 2. Storage temperature Range LA Type CAL45 Type LHL FBA/FBR FL05 Type FL06BT Type 4085 3. Rated current LA Type CAL45 Type LHL Within the specified tolerance FBA/FBR FL05 Type FL06BT Type Test Method and Remarks : The maximum DC value having inductance within 10% and temperature incease within 40 (LA:20) by the application of DC bias. LA, CA LHL : The maximum DC value having inductance decrease within 10% (LHLC08, LHLC10within 30%) and temperature increase within the following specified temperature by the application of DC bias. Reference temperature : 25 (LHL08, LHL10, LHL13) : 30 (LHL16, LHLP) : 40 (LHLC08, LHLC10) FB : No disconnection or appearance abnormality by continuous current application for 30 min. Change after the application shall be within 20% of the initial value. This is not guaranteed for electrial characteristics during current application. FL : The maximum DC value having temperature rise within specified value. 4. Impedance LA Type CAL45 Type LHL FBA/FBR FL05 Type FL06BT Type Test Method and Remarks : Measuring equipment FB Measuring frequency FL06BT : Measuring equipment Measuring frequency Within the specified tolerance Refer to individual specification : : : : Impedance analyzer (HP4191A) or its equivalent Specified frequency 4291A (HP) or its equivalent Specified frequency 5. Inductance LA Type CAL45 Type Within the specified tolerance LHL FBA/FBR Within the specified tolerance FL05 Type FL06BT Type Test Method and Remarks : Measuring equipment : LCR meter (HP4285A + HP42851A or its equivalent) LA, CA Measuring frequency : Specified frequency LHL : Measuring equipment : LCR meter (HP4285AHP42851A or its equivalent) LCR meter (HP4263A) or its equivalent (at 1kHz) Measuring frequency : Specified frequency FL05R : Measuring equipment : HP4262A or its equivalent Measuring frequency : 1kHz 6. Q LA Type Within the specified tolerance CAL45 Type LHL FBA/FBR FL05 Type FL06BT Type Test Method and Remarks LA : Measuring equipment : LCR meter (HP4285A + HP42851A or its equivalent) Measuring frequency : Specified frequency LHL (except LHLP) : Measuring equipment : LCR meter (HP4285AHP42851A or its equivalent) LCR meter (HP4263A) or its equivalent (at 1kHz) Measuring frequency : Specified frequency This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. le0104fi01_reli-RP1 12 le0104fi01_reli_e-01 RELIABILITY DATA 7. DC Resisitance LA Type CAL45 Type LHL Within the specified tolerance FBA/FBR FL05 Type FL06BT Type Test Method and Remarks LA, CA : Measuring equipment : low ohmmeter (A&D AD5812 or its equivalent) LHLFBFL : Measuring equipment : DC ohmmeter 8. Self resonance frequency LA Type Within the specified tolerance CAL45 Type LHL FBA/FBR FL05 Type FL06BT Type Test Method and Remarks LA : Measuring equipment : Network analyzer (Anritsu MS620J or its equivalent) LHL (except LHLP) : Measuring equipment : (HP4191A, 4192A) its equivalent 9. Temperature characteristic LA Type L/L : Within 5% CAL45 Type L/L : Within 7% (except LHLP16 : Within 20%) LHL FBA/FBR FL05 Type FL06BT Type Test Method and Remarks LA : Change of maximum inductance deviation in step 1 to 5 Step 1 2 3 4 5 Temperature () 20 25 (Minimum operating temperature) 20 (Standard temperature) 85 (Maximum operating temperature) 20 LHL : Change of maximum inductance deviation in step 1 to 5 Temperature at step 1 : 20 Temperature at step 2 : Minimum operating temperature Temperature at step 3 : 20 (Standard temperature) Temperature at step 4 : Maximum operating temperature Temperature at step 5 : 20 10. Tensile strength test LA Type CAL45 Type No abnormality such as cut lead, or looseness. LHL FBA/FBR No abnormality such as cut lead, or looseness. FL05 Type No abnormality such as cut lead, or looseness. FL06BT Type Test Method and Remarks : Apply the stated tensile force progressively in the direction to draw terminal. LA force (N) 25 CA duration (s) 5 : Apply the stated tensile force progressively in the direction to draw terminal. force (N) 10 duration (s) 10 LHL : Apply the stated tensile force progressively in the direction to draw terminal. Nominal wire diameter tensile d (mm) force (N) duration (s) 0.3d0.5 5 0.5d0.8 10 305 0.8d1.2 25 FBA/FBR : The body of a component shall be fixed and a tensile force of 201N shall be applied to the lead wire in the axial diretion of the component during 101 seconds. FL05R : Fix the body of a component in the direction to draw terminal,and gradually apply the tensile force of 4.9N. 11. Over current LA Type CAL45 Type LHL No emission of smoke no firing. There shall be no scorch or short of wire. LHLC08,LHLC10 : There shall be no firing. FBA/FBR FL05 Type FL06BT Type Test Method and Remarks LHL/LACAL45 Type Measuring current Duration Number of measuring : Rated currentx2 : 5 min. : one time This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. le0104fi01_reli_e-01 12 le0104fi01_reli-RP2 RELIABILITY DATA 12. Terminal strength : bending LA Type CAL45 Type No abnormality such as cut lead, or looseness. LHL FBA/FBR FL05 Type FL06BT Type Test Method and Remarks LA, CA : Suspend a weight of specified mass at the end of the terminals and incline the body through the angle of 90 degrees and return it to the initial position. This operation is done over a period of 2-3 sec. Then second bend in the opposite direction shall be made. Number of bends : Two times. Nominal wire diameter tensile Bending force Mass reference weight d (mm) (N) (kg) 0.3d0.5 2.5 0.25 0.5d0.8 5 0.50 LHFB : Suspend a weight of specified mass at the end of the terminals and incline the body through the angle of 90 degrees and return it to the initial position. This operation is done over a period of 2-3 sec. Then second bend in the opposite direction shall be made. Number of bends : Two times. Nominal wire diameter tensile Bending force Mass reference weight d (mm) (N) (kg) 0.3d0.5 2.5 0.25 0.5d0.8 5 0.5 0.8d1.2 10 1.0 13. Insulation resisitance : between the terminals and body LA Type CAL45 Type 100M min. LHL FBA/FBR FL05 Type FL06BT Type Test Method and Remarks LHL : Applied voltage : 500 VDC Duration : 60 sec. 14. Insulation resistance : between terminals and core LA Type CAL45 Type LHL FBA/FBR 1M min. (Other than materail code MA) FL05 Type FL06BT Type Test Method and Remarks FBAFBR : Applied voltage : 100 VDC Duration : 605 sec. 15. Withstanding : between the terminals and body LA Type CAL45 Type No abnormality such as insulation damage LHL FBA/FBR FL05 Type FL06BT Type Test Method and Remarks LHL : Accoding to JIS C5102. 7. 1. 3 (C) Metal global method Applied voltage : 500 VDC Duration : 60 sec. 16. DC bias characteristic LA Type L/L : Within 10% CAL45 Type LHL FBA/FBR FL05 Type FL06BT Type Test Method and Remarks LA, CA : Measure inductance with appliation of rated current using LCR meter to compare it with the initial value. 17. Body strength LA Type No abnormality as damage. CAL45 Type LHL FBA/FBR No abnormality such as cracks on body. FL05 Type FL06BT Type Test Method and Remarks : Applied force : 30N LA Duration : 10 sec. Speed : Shall attain to specified force in 2 sec. CAL45 : Applied force : 50N Duration : 10 sec. Speed : Shall attain to specified force in 2 sec. FBA : Applied force : 503N Duration : 301 sec. This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. le0104fi01_reli-RP3 12 le0104fi01_reli_e-01 RELIABILITY DATA 18. Resisitance to vibration LA Type CAL45 Type LHL FBA/FBR FL05 Type FL06BT Type Test Method and Remarks : Directions LA, CA Frequency range Amplitude Mounting method Recovery : : : : : 2 hrs each in X, Y and Z directions total : 6hrs. 10 to 55 to 10Hz (1min.) 1.5mm Soldering onto printed board. At least 1hr of recovery under the standard condition after the test, followed by the measurement within 2hrs. LHLFB Directions Frequency range Amplitude Mounting method : : : : 2 hrs each in X, Y and Z directions total : 6hrs. 10 to 55 to 10Hz (1min.) 1.5mm (But don't exceed acceleration 196m/s2 (two power)) Soldering onto printed board. L/L : Within 5% Q : 30min L/L : Within 5% L/L : Within 5% Q change : Within 30% (LHLP : only L/L) Appearance : No abnomality Impedance change : Within 20% Appearance : No abnomality 19. Resistance to shock LA Type No significant abnormality in appearance CAL45 Type LHL FBA/FBR FL05 Type FL06BT Type Test Method and Remarks : Drop test LA, CA Impact material : concrete or vinyl tile Height : 1m Total number of drops : 10 times 20. Solderability LA Type At least 75 of terminal electrode is covered by new solder. CAL45 Type LHL At least 75 of terminal electrode is covered by new solder. FBA/FBR At least 90 of terminal electrode is covered by new solder. FL05 Type At least 75 of terminal electrode is covered by new solder. FL06BT Type Test Method and Remarks : Solder temperature : 2305 LA, CA Duration : 20.5 sec. LHL : Solder temperature : 2355 : 20.5 sec. Duration Immersion depth : Up to 1.5mm from bottom of case. FB : Solder temperature : 2305 Duration : 31 sec. Immersion depth : Up to 1.5mm from terminal root. FL05R : Solder temperature : 2305 Duration : 20.5 sec. Immersion depth : Up to 2 to 2.5mm from terminal root. FL06BT : Solder temperature : 2305 Duration : 31 sec. Immersion depth : Up to 0.5 to 1.0mm from terminal root. 21. Resisitance to soldering heat LA Type CAL45 Type LHL FBA/FBR FL05 Type FL06BT Type Test Method and Remarks : Solder temperature LA, CA Duration Immersed conditions Recovery LHL : Solder bath method Manual soldering Caution Recovery FB : Solder bath method Recovery FL : Solder condition Immersion depth Recovery No significant abnormality in appearance L/L : Within 5% No significant abnormality in appearance No significant abnormality in appearance Refer to individual specification No significant abnormality in appearance : : : : Inductance change : Within 5% Impedance change : Within 20% Q change : Within 30%(LHLP : only L/L) Impedance change : Within 20% (CA) 2705, (LA) 2605 50.5 sec. One time Inserted into substrate with t=1.6mm At least 1hr of recovery under the standard condition after the test, followed by the measurement within 2hrs. : Solder temperature : 2605 Duration : 101 sec. Up to 1.5mm from the bottom of case. : Solder temperature : 35010 (At the tip of soldering iron) Duration : 51 sec. Up to 1.5mm from the bottom of case. : No excessive pressing shall be applied to terminals. : 4 to 24hrs of recovery under the standard condition after the test. : Condition 1 : Solder temperature : 2605 Duration : 101 sec. Immersion depth : Up to 1.5mm from the terminal root. Condition 2 : Solder temperature : 3505 Duration : 31 sec. Immersion depth : Up to 1.5mm from the terminal root. : 3hrs of recovery under the standard condition after the test. 101 sec. : 2605 : Up to 0.5 to 1.0mm from the terminal root. : 3hrs of recovery under the standard condition after the test. This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. le0104fi01_reli_e-01 12 le0104fi01_reli-RP4 RELIABILITY DATA 22. Resisitance to solvent LA Type Please avoid the ultrasonic cleaning of this product. CAL45 Type LHL Impedance change : Within 20% FBA/FBR No significant abnormality in appearance FL05 Type FL06BT Type Test Method and Remarks FB : Solvent temperature : 2025 Duration : 305 sec. Solvent type : Acetone Recovery : 3hrs of recovery under the standard condition after the test. 23. Thermal shock LA Type CAL45 Type LHL FBA/FBR FL05 Type FL06BT Type Test Method and Remarks : Conditions for 1cycle LA, CA L/L : Within 10% Q : 30min L/L : Within 10% Appearance : No abnormality Appearance : No abnormality Refer to individual specification Appearance : No abnormality Step Temperature () 1 250 3 303 2 Room temperature Within 3 Inductance change : Within 10% Impedance change : Within 20% Q change : Within 30% (LHLPonly L/L) Impedance change : Within 20% Duration (min.) 3 852 0 303 4 Room temperature Within 3 Number of cycles : 5 cycles Recovery : At least 1hr of recovery under the standard condition after the removal from test chamber, followed by the measurement within 2hrs. LHLFB : Accoding to JIS C0025 Conditions for 1 cycle Step Temperature () 1 Minimum operating temperature0 3 2 Room temperature 3 Minimum operating temperature2 0 4 Room temperature Number of cycles : : Recovery : : FL Duration (min.) 303 Within 3 303 Within 3 10 cyclesLHL 5 cycles (FBA, FBR) 4 to 24hrs of recovery under the standard condition after the removal from the test chamber.LHL 3hrs of recovery under the standard condition after the removal from the test chamber. (FBA, FBR) : Accoding to JIS C0025 Conditions for 1 cycle Step Temperature () 1 250 3 Duration (min.) 303 2 Room temperature Within 3 3 852 0 303 4 Room temperature Within 3 Number of cycles : 10 cycles Recovery : 1 to 2hrs of recovery under the standard condition after the removal from the test chamber. 24. Damp heat LA Type L/L : Within 10% Q : 30min CAL45 Type L/L : Within 10% LHL Impedance changeWithin 20% FBA/FBR AppearanceNo abnormality FL05 Type FL06BT Type Test Method and Remarks LA, CA : Temperature : 402 Humidity : 9095%RH Duration : 1000 hrs Recovery : At least 1hr of recovery under the standard removal from test chamber, followed by the measurement within 2hrs. FB : Temperature Humidity Duration Recovery : : : : 602 9095%RH 1000 hrs 1 to 2hrs of recovery under the standard condition after the removal from the test chamber. This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. le0104fi01_reli-RP5 12 le0104fi01_reli_e-01 RELIABILITY DATA 25. Loading under damp heat LA Type CAL45 Type LHL FBA/FBR FL05 Type FL06BT Type Test Method and Remarks : Temperature LA, CA : Humidity : Duration : Applied current : Recovery : L/L : Within 10% Q : 30min L/L : Within 10% Appearance : No abnormality Imductance change : Within 10% Refer to individual specification Appearance : No abnormality Impedance change : Within 20% Q change : Within 30% (LHLP : only L/L) 402 9095%RH 1000 hrs Rated current At least 1hr of recovery under the standard removal from test chamber, followed by the measurement within 2hrs. LHL : Temperature Humidity Duration Applied current Recovery : : : : : 402 9095%RH 100024 hrs Rated current 1 to 2hrs of recovery under the standard condition after the removal from the test chamber. FL : : : : : 603 9095%RH 500 (12, 0) hrs Rated current 1 to 2hrs of recovery under the standard condition after the removal from the test chamber. : Temperature Humidity Duration Applied current Recovery 26. Loading at high temperature LA Type L/L : Within 10% Q : 30min CAL45 Type L/L : Within 10% LHL FBA/FBR FL05 Type FL06BT Type Test Method and Remarks : Temperature LA, CA : 852 Duration : 1000 hrs Applied current : Rated current Recovery : At least 1hr of recovery under the standard removal from test chamber, followed by the measurement within 2hrs. 27. Low temperature life test LA Type L/L : Within 10% Q : 30min CAL45 Type L/L : Within 10% Inductance change : Within 10% Q change : Within 30% (LHLP : only L/L) LHL Appearance : No abnormality FBA/FBR Refer to individual specification FL05 Type Impedance change : Within 20% FL06BT Type Appearance : No abnormality Test Method and Remarks : Temperature : 252 LA, CA Duration : 1000 hrs Recovery : At least 1hr of recovery under the standard removal from test chamber, followed by the measurement within 2hrs. LHL : Temperature : 403 Duration : 100024 hrs Recovery : 1 to 2hrs of recovery under the standard condition after the removal from the test chamber. FL : Temperature : 403 Duration : 500 (12, 0) hrs Recovery : 1 to 2hrs of recovery under the standard condition after the removal from the test chamber. 28. High temperature life test LA Type CAL45 Type Inductance change : Within 10% Q change : Within 30% (LHLP : only L/L) Appearance : No abnormality LHL FBA/FBR Refer to individual specification FL05 Type Impedance change : Within 20% FL06BT Type Appearance : No abnormality Test Method and Remarks LHL : Temperature : 1053 Duration : 100024 hrs Recovery : 1 to 2hrs of recovery under the standard condition after the removal from the test chamber. FL : Temperature : 853 Duration : 500 (12, 0) hrs Recovery : 1 to 2hrs of recovery under the standard condition after the removal from the test chamber. This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. le0104fi01_reli_e-01 12 le0104fi01_reli-RP6 PRECAUTIONS CAL Type, LH Type, FB Type, FL Type, LA Type 1. Circuit Design Operating environment 1. The products described in this specification are intended for use in general electronic equipment,(office supply equipment, telecommunications systems, measuring equipment, and household equipment). They are not intended for use in mission-critical equipment or systems requiring special quality and high Precautions reliability (traffic systems, safety equipment, aerospace systems, nuclear control systems and medical equipment including life-support systems,) where product failure might result in loss of life, injury or damage. For such uses, contact TAIYO YUDEN Sales Department in advance. 2. PCB Design Design 1. Please design insertion pitches as matching to that of leads of the component on PCBs. Technical Design 1. When Inductors are mounted onto a PC board, hole dimensions on the board should match the lead pitch of the component, if not, it will cause breakage of considerations the terminals or cracking of terminal roots covered with resin as excess stress travels through the terminal legs. Precautions 3. Considerations for automatic placement Adjustment of mounting machine 1. Excessive impact load should not be imposed on the products when mounting onto the PC boards. Precautions 2. Mounting and soldering conditions should be checked beforehand. Technical Adjustment of mounting machine consider1. When installing products, care should be taken not to apply distortion stress as it may deform the products. ations 4. Soldering Wave soldering 1. Please refer to the specifications in the catalog for a wave soldering. 2. Do not immerse the entire inductor in the flux during the soldering operation. Lead free soldering 1. When using products with lead free soldering, we request to use them after confirming adhesion, temperature of resistance to soldering heat, soldering etc sufficiently. Recommended conditions for using a soldering iron: Precautions Put the soldering iron on the land-pattern. Soldering iron's temperature - Below 350 Duration - 3 seconds or less The soldering iron should not directly touch the inductor. Reflow soldering 1. As for reflow soldering, please contact our sales staff. Technical Lead free soldering 1. If products are used beyond the range of the recommended conditions, heat stresses may deform the products, and consequently degrade the reliability of considerations the products. 5. Cleaning Precautions Technical considerations Cleaning conditions 1. CAL type, LH type, LA Type Please do not do cleaning by a supersonic wave. Cleaning conditions 1. CAL type, LH type, LA Type If washing by supersonic waves, supersonic waves may deform products. 6. Handling Handling 1. Keep the inductors away from all magnets and magnetic objects. Mechanical considerations 1. Please do not give the inductors any excessive mechanical shocks. 2. LH type Precautions If inductors are dropped onto the floor or a hard surface they should not be used. Packing 1. Please do not give the inductors any excessive mechanical shocks. In loading, please pay attention to handling indication mentioned in a packing box (a loading direction / number of maximum loading / fragile item). Handling 1. There is a case that a characteristic varies with magnetic influence. Mechanical considerations Technical 1. There is a case to be damaged by a mechanical shock. consider2. LH type ations There is a case to be broken by a fall. Packing 1. There is a case that a lead wire could be deformed by a fall or an excessive shock. 7. Storage conditions Storage 1. To maintain the solderability of terminal electrodes and to keep the packing material in good condition, temperature and humidity in the storage area should be controlled. Recommended conditions Ambient temperature 040 Precautions Humidity Below 70% RH The ambient temperature must be kept below 30. Even under ideal storage conditions, solderability of products electrodes may decrease as time passes. For this reason, inductors should be used within one year from the time of delivery. In case of storage over 6 months, solderability shall be checked before actual usage. Technical Storage 1. Under a high temperature and humidity environment, problems such as reduced solderability caused by oxidation of terminal electrodes and deterioration of considerations taping/packaging materials may take place. This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification. For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs. le0104fi01_reli-RP7 12 le0104fi01_reli_e-01