COMMUNICATIONS COMPONENTS Fused Coupler, Near Infrared Key Features * 700 to 1150 nm operation * Available in any coupling ratio * All fiber -- no lens alignment * No unwanted reflections * Low light loss * High power handling Applications * Fiber lasers * Sensors * Avionics * Biomedical equipment * Research NORTH AMERICA : 800 498-JDSU (5378) The JDSU near infrared fused coupler splits or combines light at any selected wavelength from 700 to 1150 nm. Designed for applications in fiber laser, sensor and avionics applications, the coupler utilizes low loss fused fiber technology. No light leaves the fiber and therefore no alignment is required; and there are no unwanted reflections. Furthermore the output fiber pigtails may be directly integrated into beam delivery systems. WORLDWIDE : +800 5378-JDSU WEBSITE : www.jdsu.com FUSED COUPLER, NEAR INFRARED 2 Configuration 1x2 P2 (Blue) SIGNAL (Input) P1 (Red) COMMON (Input) P3 (Red) TAP (Output) 2x2 P1 (Red) COMMON (Input) P2 (Blue) SIGNAL (Input) P4 (Blue) P3 (Red) TAP (Output) Insertion Loss Coupling Ratio Grade Available Housing Option Signal Path Insertion Loss1, 2 (Maximum) Tap Path Insertion Loss1, 2 (Maximum) 10% 10% 20% 20% 30% 30% 40% 40% 50% 50% A B A B A B A B A B 3, 4, 5, 6 3, 4, 5, 6 3, 4, 5, 6 3, 4, 5, 6 3, 4, 5, 6 3, 4, 5, 6 3, 4, 5, 6 3, 4, 5, 6 3, 4, 5, 6 3, 4, 5, 6 0.9 dB 1.1 dB 1.5 dB 1.7 dB 2.2 dB 2.4 dB 3.0 dB 3.2 dB 3.8 dB 4.0 dB 12.2 dB 12.4 dB 8.4 dB 8.6 dB 6.4 dB 6.5 dB 4.9 dB 5.1 dB 3.8 dB 4.0 dB 1. Insertion loss at operating wavelength range (not including PDL, TDL or connector losses). 2. In 2x2 couplers with a coupling ratio of 20% or lower, insertion loss is not specified for launch through second input port (P4). FUSED COUPLER, NEAR INFRARED 3 Housing Option Housing Code Description 1x2, 2x2 Dimensions (mm) Pigtail 3 4 5 6 Regular O 0.9 mm slim O 0.9 mm semi-ruggedized O 3.0 mm fully ruggedized 3.0 (O) x 50 (L) 3.0 (O) x 60 (L) 5.0 (O) x 75 (L) 80 (L) x 10 (W) x 8 (H) Primary-coated fiber O 0.9 mm loose-tube O 0.9 mm loose-tube O 3.0 mm fan-out sleeving Specifications Parameter Operating wavelength range1 Excess loss Return loss/Directivity Pigtail tensile load Optical power handling Operating temperature range2 Storage temperature range Fiber type Grade A Typical Minimum Maximum Maximum Grade B Any wavelength within the 700 to 1150 nm range 0.30 dB 0.50 dB 50 dB 5N 4W -40 to 75 C -40 to 85 C Speciality fiber 1. Any specific wavelength point from within the range 633 to 850 nm may be selected. For wavelengths outside of this range, contact JDSU with specific requirements. 2. For connectorised component, operating temperature range is -5 to 75 C. FUSED COUPLER, NEAR INFRARED 4 Ordering Information For more information on this or other products and their availability, please contact your local JDSU account manager or JDSU directly at 1-800-498-JDSU (5378) in North America and +800-5378-JDSU worldwide or via e-mail at customer.service@jdsu.com. Sample: FFS-060K31A10 (Fused Fiber Speciality Coupler, 1060 nm, 50/50 coupling ratio, regular housing, 1x2, A grade, 1 m pigtails, no connectors) FFSCode 7 8 9 0 1 Wavelength (First Digit) 7xx nm 8xx nm 9xx nm 10xx nm 11xx nm Code Wavelength (Second and Third Digit) Examples: 33 x33 nm 32 x32 nm 57 x57 nm Code A C E H K Coupling Ratio1 10% 20% 30% 40% 50% Code 3 4 5 Housing2 Regular O 0.9 mm slim O 0.9 mm semi-ruggedised O 3.0mm fully ruggedised 6 Code 1 2 Configuration 1x2 2x2 Code A B Grade Grade A Grade B Code Pigtail Length3 (Minimum) 0.5 meter 1 meter 0 1 Code 0 1 3 5 9 A B Connectors2, 4 None FC/PC FC/APC SC/APC FC/UPC SC/UPC LC5 1. Other coupling ratio are available. Please contact JDSU for ordering codes of coupling ratios not listed. 2. Connectors may be fitted to housing types 4, 5 and 6. For connectorisation of housing type 3, please contact JDSU sales office. 3. Minimum pigtail length. Other pigtail lengths are available on request. When the pigtail has been modified to include a connector, pigtail length measurment includes the connector end face. 4. Excess Loss in specification table does not include connector losses. 5. LC connector is not available for housing code 6, fully ruggedised housing. LC is a registered trademark of Lucent Technologies. NORTH AMERICA : 800 498-JDSU (5378) WORLDWIDE : +800 5378-JDSU WEBSITE : www.jdsu.com Product specifications and descriptions in this document subject to change without notice. (c) 2007 JDS Uniphase Corporation 21025845 Rev. 003 10/05 FFSNI.DS.CC.AE March 2007