ELECTRICAL CHARACTERISTICS (TA= 0 to 70°C unless otherwise specified.)
Parameter Test Conditions Symbol Device Min Typ** Max Unit
EMITTER TA=25°C) VFAll 1.0 1.27 1.7
Input Forward Voltage (IF= 1.6 mA) 1.75 V
Input Reverse Breakdown Voltage (TA= 25°C, IR= 10 µA) BVRAll 5.0 20
Temperature coefficient of forward voltage (IF= 1.6 mA) (VF/TA) All -1.8 mV/°C
DETECTOR (IF= 0 mA, VO= VCC = 18 V) IOH
HCPL-0701 0.01 100 µA
Logic high output current (IF= 0 mA, VO= VCC = 7 V) HCPL-0700 0.01 250
Logic low supply (IF= 1.6 mA, VO= Open) ICCL
HCPL-0700 0.4 1.5 mA
(VCC = 18 V) HCPL-0701
Logic high supply (IF= 0 mA, VO= Open) ICCH
HCPL-0700 0.05 10 µA
(VCC = 18 V) HCPL-0701
INDIVIDUAL COMPONENT CHARACTERISTICS
Parameter Test Conditions Symbol Device Min Typ** Max Unit
COUPLED (IF= 0.5 mA, VO= 0.4 V, VCC = 4.5 V) HCPL-0701 400 2000 5000
Current transfer ratio (IF= 1.6 mA, VO= 0.4 V, VCC = 4.5 V) CTR HCPL-0701 500 1300 2600 %
(Notes 1,2) (IF= 1.6 mA, VO= 0.4 V, VCC = 4.5 V) HCPL-0700 300 1300 2600
(IF= 0.5 mA, IO= 2 mA, VCC = 4.5 V) 0.05 0.4
Logic low output voltage (IF= 1.6 mA, IO= 8 mA, VCC = 4.5 V) HCPL-0701 0.10 0.4
output voltage (IF= 5 mA, IO= 15 mA, VCC = 4.5 V) VOL 0.13 0.4 V
(Note 2) (IF= 12 mA, IO= 24 mA, VCC = 4.5 V) 0.20 0.4
(IF= 1.6 mA, IO= 4.8 mA, VCC = 4.5 V) HCPL-0700 0.08 0.4
TRANSFER CHARACTERISTICS (TA= 0 to 70°C Unless otherwise specified)
** All typicals at TA= 25°C
SINGLE-CHANNEL
HCPL-0700
HCPL-0701
Characteristics Test Conditions Symbol Min Typ** Max Unit
(Relative humidity = 45%)
Input-output (TA = 25°C, t = 5 s) II-O 1.0 µA
insulation leakage current (VI-O = 3000 VDC)
(Note 4)
Withstand insulation test voltage (RH 650%, TA = 25°C) VISO 2500 VRMS
(Note 4, 5) ( t = 1 min.)
Resistance (input to output) (Note 4) (VI-O = 500 VDC) RI-O 1012 1
ISOLATION CHARACTERISTICS (TA= 0 to 70°C Unless otherwise specified)
www.fairchildsemi.com 2 OF 9 3/5/01 DS300394
LOW INPUT CURRENT
HIGH GAIN SPLIT
DARLINGTON OPTOCOUPLERS