65 Watt Medical Desktop Power Supply | Elpac MWA065 -- ICCNexergy Page 1 of 4 MWA065 Series 65 Watt Medical Desktop Power Supply * * * * * * High Efficiency: Level V High Power Density 4.9W/in3 Lifetime Expectation >5 years Hold-up Time >25ms at full load EISA, CEC Compliant Medical Approval - EN60601-1 Class I Elpac Part Number Output Voltage Output Current Peak MWA065009A-11A 9.0V 8.0A 9.6A 5% 85% MWA065012A-11A 12.0V 6.0A 7.2A 5% 88% MWA065015A-11A 15.0V 4.8A 5.7A 5% 89% MWA065024A-11A 24.0V 3.0A 3.6A 5% 91% Current Total 1 Regulation Typical 2 Efficiency3 Notes 1 Maximum peak load (86W) lasting 500ms with a maximum 10% duty cycle. 2 Includes initial setting, line regulation, load regulation, and thermal drift. 3 Typical at 115VAC, full load (including output cable). Input Input Voltage 85 - 264VAC 100 - 240VAC Nominal Input Frequency 47 - 63Hz Input Current <1.5A rms Inrush Current <37A at 230VAC cold start Zero Load Power Consumption <0.5W Earth Leakage Current (Typical) <80A @ 132VAC @ 60Hz <100A @ 264VAC @ 60Hz Patient Leakage Current <40A @ 132VAC @ 60Hz <50A @ 264VAC @ 60Hz Output Output Voltage See Table Total Regulation +/-5% http://iccnexergy.com/elpac/medical-power-supplies/external/mwa065/ 1/19/2012 65 Watt Medical Desktop Power Supply | Elpac MWA065 -- ICCNexergy Minimum Load No minimum load required Start-Up Delay <750ms Hold-Up Time >25ms at any input voltage Ripple & Noise <1% pk-pk * Over Voltage Protection 110-135% Over Temperature Protection Active - Recoverable; plus Passive - Non Recoverable Over Current Protetion 120 - 180% Short Circuit Protection shutdown, auto-restart (hiccup mode) Page 2 of 4 Notes * Ripple and noise measured with 20MHz bandwidth; 10F tantalum capacitor in parallel with a 0.1F ceramic capacitor. General Efficiency Avg Efficiency 88.2% @ 115VAC; 89.7% @ 230VAC MTBF min. 200,000 hours demonstrated Size 5.02" (127.6mm) x 2.20" (55.9mm) x 1.37" (34.8mm) Weight 1.3 lbs (.59 kg) Power Density 4.9W/in3 Environmental Operating Temperature 0 - 60C (Full load to 40C, derate linearly to 50% load at 60C) Storage Temperature -40C to +85C Relative Humidity 5-95%, non-condensing Cooling Natural Convection Vibration All units production tested to 19.6m/s2 EMC & Safety Emissions FCC class B, CISPR11 class B EN61000-3-2, -3 Immunity EN61000-4-2, -3, -4, -5, -6, -8, -11 Certified by TUV to the following: cTUVus UL 60601-1 CAN/CSA-22.2 No.601.1-M90 CB per IEC60601-1 CE marked to LVD http://iccnexergy.com/elpac/medical-power-supplies/external/mwa065/ 1/19/2012 65 Watt Medical Desktop Power Supply | Elpac MWA065 -- ICCNexergy Page 3 of 4 Input Configuration Standard Input Cable Not Provided Connection on Power Supply Body IEC 320 C14 Receptacle Output Configuration (12V, 18V, 24V) Standard Output Cable 6 ft. Cord Size 2x16awg Connector (PSU side) Switchcraft DIN-5, P/N 05GM5MX (male pins) Mating Connector Switchcraft 57GB5FX or equivalent Output Configuration (9V) Standard Output Cable 4 ft. Cord Size 2x16awg Connector (PSU side) Switchcraft DIN-5, P/N 05GM5MX (male pins) Mating Connector Switchcraft 57GB5FX (5 pin) or equivalent Output Pin Assignments Pin 1 Return Pin 2 Return Pin 3 +V1 Pin 4 Return Pin 5 +V1 http://iccnexergy.com/elpac/medical-power-supplies/external/mwa065/ 1/19/2012 65 Watt Medical Desktop Power Supply | Elpac MWA065 -- ICCNexergy Page 4 of 4 MWA065 | ICCNEXERGY | (c) 2011 | http://iccnexergy.com/elpac/medical-power-supplies/external/mwa065/ 1/19/2012