INTEGRATED CIRCUITS DIVISION
www.ixysic.com
DS-PLA140-R08 1
PLA140
Single-Pole Normally Open
OptoMOS® Relay
e3
Pb
Applications
Features
Description
Ordering Information
Parameter Rating Units
Blocking Voltage 400 VP
Load Current 250 mArms / mADC
On-Resistance (max) 8
Pin Configuration
Part Number Description
PLA140 6-Pin DIP (50/Tube)
PLA140S 6-Pin Surface Mount (50/Tube)
PLA140STR 6-Pin Surface Mount (1,000/Reel)
Switching Characteristics of
Normally Open Devices
Low On-Resistance, High Current Handling
Low Drive Power Requirements (TTL/CMOS
Compatible)
3750Vrms Input/Output Isolation
High Reliability
VDE Compatible
FCC Compatible
Arc-Free With No Snubbing Circuits
No EMI/RFI Generation
Machine Insertable, Wave Solderable
Small 6-Pin Package
Surface Mount Tape & Reel Version Available
Telecommunications
Telecomm Switching
Hook Switch
Instrumentation
Multiplexers
Data Acquisition
Electronic Switching
I/O Subsystems
Meters (Watt-Hour, Water, Gas)
Medical Equipment—Patient/Equipment Isolation
Security
Aerospace
Industrial Controls
Automotive
Approvals
UL Certified Component: File E76270
CSA Certified Component: Certificate 1175739
Certified to EN60950
TUV Certificate B 09 07 49410 004
Form-A
I
F
I
LOAD
10%
90%
ton toff
1
3
2
4
5
6
+ Control
– Control
Do Not Use
Load
Do Not Use
Load
AC/DC Configuration
1
3
2
4
5
6
+ Control
– Control
Do Not Use
+ Load
– Load
DC Only Configuration
The PLA140 is a single-pole normally open
(1-Form-A) Solid State Relay that uses optically
coupled MOSFET technology to provide 3750Vrms of
input-to-output isolation.
MOSFET output switches, which use IXYS
Integrated Circuits Division's patented OptoMOS
architecture, are controlled by a highly efficient
GaAIAs infrared LED.
The PLA140’s combination of low on-resistance and
high load current handling makes it suitable for a
variety of industrial applications.
Because Solid State Relays like the PLA140 have no
moving parts, they offer faster, bounce-free switching
in a more compact surface mount or though hole
package than traditional electromechanical relays.
INTEGRATED CIRCUITS DIVISION
www.ixysic.com
2R08
PLA140
Absolute Maximum Ratings @ 25ºC
Electrical Characteristics @ 25ºC
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Parameter Ratings Units
Blocking Voltage 400 VP
Reverse Input Voltage 5 V
Input Control Current 50 mA
Peak (10ms) 1 A
Input Power Dissipation 1150 mW
Total Power Dissipation 2800 mW
Isolation Voltage, Input to Output 3750 Vrms
Operational Temperature -40 to +85 °C
Storage Temperature -40 to +125 °C
1 Derate linearly 1.33 mW / ºC
2 Derate linearly 6.67 mW / ºC
Parameter Conditions Symbol Min Typ Max Units
Output Characteristics
Load Current (Continuous)
AC/DC Configuration IF=5mA IL
- - 250 mArms / mADC
DC Configuration - - 350 mADC
Peak Load Current IF=5mA , t=10ms ILPK - - ±500 mAP
On-Resistance
AC/DC Configuration IF=5mA , IL=250mA RON
- 5.5 8
DC Configuration IF=5mA , IL=350mA - 1.5 3
Off-State Leakage Current VL=400VPILEAK -- 1 µA
Switching Speeds
Turn-On IF=5mA, VL=10V ton - 0.4 3 ms
Turn-Off toff - 0.19 1
Output Capacitance IF=0mA , VL=50V, f=1MHz COUT -18 - pF
Input Characteristics
Input Control Current to Activate IL=250mA IF- 0.46 5 mA
Input Control Current to Deactivate - IF0.2 0.44 - mA
Input Voltage Drop IF=5mA VF0.9 1.2 1.4 V
Reverse Input Current VR=5V IR- - 10 µA
Common Characteristics
Input to Output Capacitance - CI/O -3 - pF
INTEGRATED CIRCUITS DIVISION
PLA140
www.ixysic.com 3
R08
PERFORMANCE DATA*
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application
department.
LED Forward Voltage (V)
1.235 1.240 1.245 1.250 1.255 1.260 1.265
Device Count (N)
0
5
10
15
20
25
30
Typical LED Forward Voltage Drop
(N=50, IF=5mA)
LED Current (mA)
0.28 0.34 0.40 0.46 0.52 0.58 0.64 0.70
Device Count (N)
0
5
10
15
20
Typical IF for Switch Operation
(IL=250mA)
On-Resistance (:)
4.7 4.8 4.9 5.0 5.1 5.2 5.3 5.4
Device Count (N)
0
5
10
15
20
Typical On-Resistance Distribution
(N=50, IF=5mA, IL=250mA)
Turn-On Time (ms)
0.675 0.750 0.825 0.900 0.975 1.050 1.125 1.200
Device Count (N)
0
5
10
15
20
25
Typical Turn-On Time
(N=50, IF=5mA, IL=100mA)
Turn-Off Time (ms)
0.13 0.15 0.17 0.19 0.21 0.23 0.25 0.27
Device Count (N)
0
5
10
15
20
25
Typical Turn-Off Time
(N=50, IF=5mA, IL=100mA)
Blocking Voltage (VP)
442 448 454 460 466 472 478 484
Device Count (N)
0
5
10
15
20
Typical Blocking Voltage Distribution
(N=50, IF=0mA)
Temperature (ºC)
-40 -20 0 20 40 60 80 100
LED Forward Voltage (V)
1.1
1.2
1.3
1.4
1.5
1.6
Typical LED Forward Voltage Drop
vs. Temperature
IF=50mA
IF=20mA
IF=10mA
IF=5mA
LED Current (mA)
0 1020304050
Turn-On Time (ms)
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
Typical Turn-On Time
vs. LED Forward Current
(IL=100mA)
LED Current (mA)
0 1020304050
Turn-Off Time (ms)
0.16
0.18
0.20
0.22
0.24
0.26
Typical Turn-Off Time
vs. LED Forward Current
(IL=100mA)
Temperature (ºC)
-40 -20 0 20 40 60 80 100
LED Current (mA)
0.44
0.46
0.48
0.50
0.52
0.54
0.56
0.58
0.60
Typical IF for Switch Operation
vs. Temperature
(IL=100mA)
Temperature (ºC)
-40 -20 0 20 40 60 80 100
Turn-On Time (ms)
0.5
0.6
0.7
0.8
0.9
1.0
1.1
1.2
1.3
1.4
Typical Turn-On Time vs. Temperature
(IF=5mA, IL=100mA)
Temperature (ºC)
-40 -20 0 20 40 60 80 100
Turn-Off Time (ms)
0.14
0.16
0.18
0.20
0.22
0.24
0.26
Typical Turn-Off Time vs. Temperature
(IF=5mA, IL=100mA)
INTEGRATED CIRCUITS DIVISION
www.ixysic.com
4R08
PLA140
PERFORMANCE DATA*
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifications, please contact our application
department.
Temperature (ºC)
-40 -20 0 20 40 60 80 100
On-Resistance (:)
3
4
5
6
7
8
9
Typical On-Resistance vs. Temperature
AC/DC Configuration
(IF=5mA, IL=100mA)
Load Voltage (V)
-1.5 -1.0 -0.5 0.0 0.5 1.0 1.5
Load Current (A)
-0.3
-0.2
-0.1
0.0
0.1
0.2
0.3
Typical Load Current vs. Load Voltage
AC/DC Configuration
(IF=5mA)
Temperature (ºC)
-40 -20 0 20 40 60 80 100
Load Current (mA)
100
125
150
175
200
225
250
275
Maximum Load Current
vs. Temperature - AC/DC Configuration
(IF=5mA)
Temperature (ºC)
-40 -20 0 20 40 60 80 100
On-Resistance (:)
1.0
1.2
1.4
1.6
1.8
2.0
2.2
2.4
Typical On-Resistance vs. Temperature
DC-Only Configuration
(IF=5mA, IL=100mA)
Load Voltage (V)
0.0 0.1 0.2 0.3 0.4 0.5 0.6
Load Current (A)
0.00
0.05
0.10
0.15
0.20
0.25
0.30
0.35
0.40
Typical Load Current vs. Load Voltage
DC-Only Configuration
(IF=5mA)
Temperature (ºC)
-40 -20 0 20 40 60 80 100
Load Current (mA)
150
175
200
225
250
275
300
325
350
375
Maximum Load Current
vs. Temperature - DC-Only Configuration
(IF=5mA)
Temperature (ºC)
-40 -20 0 20 40 60 80 100
Blocking Voltage (VP)
440
450
460
470
480
490
500
510
Typical Blocking Voltage
vs. Temperature
Temperature (ºC)
-40 -20 0 20 40 60 80 100
Leakage Current (nA)
0
10
20
30
40
50
60
70
80
Typical Leakage vs. Temperature
Measured Across Pins 4&6
(VL=400V)
Time
10Ps 100Ps 1ms 10ms 100ms 1s 10s 100s
Load Current (A)
0.2
0.4
0.6
0.8
1.0
1.2
Energy Rating Curve
INTEGRATED CIRCUITS DIVISION
PLA140
www.ixysic.com 5
R08
Manufacturing Information
Moisture Sensitivity
All plastic encapsulated semiconductor packages are susceptible to moisture ingression. IXYS Integrated
Circuits Division classified all of its plastic encapsulated devices for moisture sensitivity according to
the latest version of the joint industry standard, IPC/JEDEC J-STD-020, in force at the time of product
evaluation. We test all of our products to the maximum conditions set forth in the standard, and guarantee proper
operation of our devices when handled according to the limitations and information in that standard as well as to any
limitations set forth in the information or standards referenced below.
Failure to adhere to the warnings or limitations as established by the listed specifications could result in reduced
product performance, reduction of operable life, and/or reduction of overall reliability.
This product carries a Moisture Sensitivity Level (MSL) rating as shown below, and should be handled according
to the requirements of the latest version of the joint industry standard IPC/JEDEC J-STD-033.
Device Moisture Sensitivity Level (MSL) Rating
PLA140 / PLA140S MSL 1
ESD Sensitivity
This product is ESD Sensitive, and should be handled according to the industry standard JESD-625.
Reflow Profile
This product has a maximum body temperature and time rating as shown below. All other guidelines of J-STD-020
must be observed.
Device Maximum Temperature x Time
PLA140 / PLA140S 250ºC for 30 seconds
Board Wash
IXYS Integrated Circuits Division recommends the use of no-clean flux formulations. However, board washing to
remove flux residue is acceptable. Since IXYS Integrated Circuits Division employs the use of silicone coating as
an optical waveguide in many of its optically isolated products, the use of a short drying bake could be necessary
if a wash is used after solder reflow processes. Chlorine- or Fluorine-based solvents or fluxes should not be used.
Cleaning methods that employ ultrasonic energy should not be used.
e3
Pb
INTEGRATED CIRCUITS DIVISION
www.ixysic.com
6R08
PLA140
MECHANICAL DIMENSIONS
Dimensions
mm
(inches)
PCB Hole Pattern
6.350 ± 0.127
(0.250 ± 0.005)
2.540 ± 0.127
(0.100 ± 0.005)
7.620 ± 0.127
(0.300 ± 0.005)
5.080 ± 0.127
(0.200 ± 0.005)
6 - 0.800 DIA.
(6 - 0.031 DIA.)
0.254 ± 0.0127
(0.010 ± 0.0005)
9.144 ± 0.508
(0.360 ± 0.020)
7.239 TYP
(0.285 TYP)
7.620 ± 0.254
(0.300 ± 0.010)
3.302 ± 0.051
(0.130 ± 0.002) 4.064 TYP
(0.160 TYP)
0.457 ± 0.076
(0.018 ± 0.003)
8.382 ± 0.381
(0.330 ± 0.015) 2.54 ± 0.127
(0.100 ± 0.005)
6.350 ± 0.127
(0.250 ± 0.005)
1.651 ± 0.254
(0.065 ± 0.010)
Pin 1
Dimensions
mm
(inches)
PCB Land Pattern
0.254 ± 0.0127
(0.010 ± 0.0005)
7.620 ± 0.254
(0.300 ± 0.010)
0.635 ± 0.127
(0.025 ± 0.005)
3.302 ± 0.051
(0.130 ± 0.002)
4.445 ± 0.254
(0.175 ± 0.010)
2.54
(0.10)
8.90
(0.3503)
1.65
(0.0649)
0.65
(0.0255)
8.382 ± 0.381
(0.330 ± 0.015) 2.54 ± 0.127
(0.100 ± 0.005)
9.524 ± 0.508
(0.375 ± 0.020) 6.350 ± 0.127
(0.250 ± 0.005)
0.457 ± 0.076
(0.018 ± 0.003)
1.651 ± 0.254
(0.065 ± 0.010)
1.651 ± 0.254
(0.065 ± 0.010)
Pin 1
PLA140
PLA140S
INTEGRATED CIRCUITS DIVISION
For additional information please visit our website at: www.ixysic.com
7
PLA140
IXYS Integrated Circuits Division makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication and reserves the right to make
changes to specifications and product descriptions at any time without notice. Neither circuit patent licenses nor indemnity are expressed or implied. Except as set forth in IXYS Integrated
Circuits Division’s Standard Terms and Conditions of Sale, IXYS Integrated Circuits Division assumes no liability whatsoever, and disclaims any express or implied warranty, relating to
its products including, but not limited to, the implied warranty of merchantability, fitness for a particular purpose, or infringement of any intellectual property right.
The products described in this document are not designed, intended, authorized or warranted for use as components in systems intended for surgical implant into the body, or in other
applications intended to support or sustain life, or where malfunction of IXYS Integrated Circuits Division’s product may result in direct physical harm, injury, or death to a person or severe
property or environmental damage. IXYS Integrated Circuits Division reserves the right to discontinue or make changes to its products at any time without notice.
Specification: DS-PLA140-R08
©Copyright 2012, IXYS Integrated Circuits Division
OptoMOS® is a registered trademark of IXYS Integrated Circuits Division
All rights reserved. Printed in USA.
12/22/2012
NOTES:
1. All dimensions carry tolerances of EIA Standard 481-2
2. The tape complies with all “Notes” for constant dimensions listed on page 5 of EIA-481-2
Dimensions
mm
(inches)
Embossment
Embossed
Carrier
330.2 Dia
(13.00 Dia)
Top Cover
Tape Thickness
0.102 Max
(0.004 Max)
W=16.00
(0.63)
B0 = 10.10
(0.398)
A0 = 10.10
(0.398)
P = 12.00
(0.472)
K1 = 3.80
(0.15)
K0 = 4.90
(0.19)
User Direction of Feed
PLA140STR Tape & Reel
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
IXYS:
PLA140 PLA140L PLA140LS PLA140STR PLA140S PLA140LSTR