Data Sheet ACD-41PQ 1000A Power Quality Clampon with THD Measurement The ACD-41PQ provides a simple and effective way to verify if the electrical system is affected by harmonics. Enhanced troubleshooting capabilities with the Power analysis functions. Increase your ability analyze the data with an optional PC interface kit. TRMS sensing Measurements: Total Harmonics Distortion THD, AC/DC Voltage up to 600V, AC Current up to 1000A, Resistance, Frequency, Temperature ACD-41PQ also measures Active (W), Reactive (VAR) and Apparent (VA) Power with dual-display Power Factor readout No hassle warranty AutoTectTM - Auto Selection of AC Volts, DC Volts or AC Amps Total Harmonic Distortion to 51st harmonic No waiting. Optional PC interface capability No shipping charges. Audible continuity Our commitment to high-quality products and customer service is demonstrated by our industry exclusive "No Hassle" warranty. In the unlikely event that an Amprobe Test Tool requires warranty service, any of our local dealers are authorized to replace it, on the spot. (note: $500 MSLP limit) Auto power off Automatic polarity Low battery indication Peak hold Data hold Large, easy to read LCD display with backlight Accommodates conductors up to 1.77" (45mm) in diameter Carrying case, test leads, batteries (installed), thermocouple and manual included Voltage overload protection for all functions up to 600V AC/DC 600V Amprobe(R) Test Tools www.Amprobe.com ACD-41PQ 1000A Power Quality Clamp-on with THD Measurement Data Sheet Specifications (valid for 23 C 5 C, for less than 70 % relative humidity). Display Voltage functions Power, Ohm & Hz functions ACA clamp-on function Update Rate 6000 counts LCD display(s) 9999 counts LCD display(s) 4000 counts LCD display(s) Power function Voltage, ACA clamp-on, Ohm, Hz & Temperature functions 1 per second nominal 4 per second nominal Polarity Operating Temperature Altitude Storage Temperature Temperature Coefficient Sensing Power Supply Low Battery Power Consumption Jaw opening & Conductor diameter Dimension Weight Safety LVD Automatic 0C to 40C; < 80% RH @ < 31C; decreasing linearly to 50% RH @ 40C Indoor operation, below 2000m. -20C to 60C, < 80% R.H. (with battery removed) nominal 0.15 x (specified accuracy)/ C @ (0C -18C or 28C -40C) True RMS sensing standard 1.5V AAA Size (NEDA 24A or IEC LR03) battery X 2 Below approx. 2.4V Voltage, ACA, Hz & Power functions 10mA typical Ohm & Temperature functions 4mA typical APO Timing Idle for 17 minutes APO Consumption 10A typical EN 61326-1 EMC 45mm max 224 x 78mm x 40mm (8.9 x 3.1 x 1.6 in.) 224 gm approx Meets EN60101-1:2001; EN61010-2-032(2002), Category III- 600 Volts ac & dc; pollution degree : 2 Electrical Specifications AC Voltage Voltage 600.0V CMRR Input Impedance Crest Factor ACV AutoTechTM Threshold DC Voltage Range Accuracy NMRR CMRR Input Impedance DCV AutoTechTM Threshold Range Accuracy 50Hz to 60Hz (0.5% rdg + 5d) 45 to 50Hz, 60 to 500Hz (1.5% rdg + 5d) 500Hz to 3.1kHz (2.5% rdg + 5d) > 60 dB @ DC to 60 Hz, Rs = 1 k 2 M, 30 pF nominal < 2.3 : 1 at full scale; < 4.6 : 1 at half scale 30VAC (40 to 500 Hz) nominal 600.0 V (0.5% rdg + 5d) > 50 dB @ 50/60 Hz >120 dB @ DC, 50/60 Hz, Rs = 1 k 2 M, 30 pF nominal 2.4VDC nominal PEAK-rms HOLD (ACA & ACV only) Response 65ms to 90% rdg Amprobe(R) Test Tools ACD-41PQ 1000A Power Quality Clamp-on with THD Measurement Data Sheet Electrical Specifications (continued) Ohms Range Accuracy Open Circuit Voltage Audible Continuity Tester Audible threshold Response time 000.0 to 999.9 (1.0% rdg + 6d) 0.4VDC typical between 10 and 300 250s ACA Current (Clamp-on) Range 40.00A, 400.0A, 1000A 40.00A, 400.0A 1000A 40.00A, 400.0A 1000A ACA AutoTechTM Threshold Crest Factor 1) 2) Frequency Accuracy 1) 2) 50 Hz / 60 Hz (0.5% rdg + 5d) 45 to 50 Hz, 60 to 500 Hz (2.0% rdg + 5d) 45 to 50 Hz, 60 to 500 Hz (2.5% rdg + 5d) 500 Hz to 3.1 kHz (2.5% rdg + 5d) 500 Hz to 3.1 kHz (3.0% rdg + 5d) 1A AC (40Hz ~ 500Hz only) nominal 40.00A & 400.0A: < 2.5 : 1 at full scale; < 5.0 : 1 at half scale 1000A: < 1.4 : 1 at full scale; < 2.8 : 1 at half scale Induced error from adjacent current-carrying conductor: < 0.06A/A Specified accuracy is from 1% rdg to 100% rdg of range and for measurements made at the jaw center. When the conductor is not positioned at the jaw center, position errors introduced are: Add + 1% rdg to specified accuracy for measurements made WITHIN jaw marking lines (away from jaw opening) Add + 4% rdg to specified accuracy for measurements made BEYOND jaw marking lines (toward jaws opening) Temperature Range -50C to -20C -20C to 300C -58F to -4F Accuracy (2.0% rdg + 6C) (2.0% rdg + 3C) (2.0% rdg + 12F) -4F to 572F (2.0% rdg + 6F) Type-K thermocouple range & accuracy not included Frequency Range Accuracy Range 40A 400A 1000A 600V 5.00 Hz to 500.0 Hz (0.5% rdg +4d Sensitivity (Sine RMS) > 4A > 40A > 400A > 30V THD% rdg-F (Total Harmonic RMS / Fundamental RMS) x 100% Range: 0.0% to 999.9% (Range for Dual Display mode: 0% to 99%) Harmonic Accuracy (Specified accuracy @ ACA fundamental > 5A ; ACV fundamental > 50V) Fundamental (1.5% rdg + 6d) 2nd ~ 3rd (5.0% rdg + 6d) 4th ~ 16th (2.5% rdg + 6d) 17th ~ 46th (3.0% rdg + 6d) 47th ~ 51st (4.5% rdg + 6d) www.Amprobe.com Data Sheet ACD-41PQ 1000A Power Quality Clamp-on with THD Measurement Electrical Specifications (continued) Total Power Factor (PF) Range 0.10 to 0.99 0.10 to 0.99 Accuracy (Specified accuracy @ ACA fundamental > 2A ; ACV fundamental > 50V) F to 21st harmonic 22nd to 51st harmonic 3d 5d Power (VA) Range 0 to 600.0 kVA @ PF = 0.99 to 0.1 Accuracy 1) 2) F to 10th (2.0% rdg + 6d) 11th to 46th (3.5% rdg + 6d) 47th to 51st (5.5% rdg + 6d) Power (kW and kVAR) Range Accuracy 1) 3) 0 to 600.0 kW / kVAR F to 10th 11th to 25th 26th to 46th 47th to 51st @ PF = 0.99 to 0.70 (2.0% rdg + 6d) (3.5% rdg + 6d) (4.5% rdg + 6d) (10% rdg +6d) @ PF = 0.70 to 0.50 (3.0% rdg + 6d) (3.5% rdg + 6d) (4.5% rdg + 6d) (10% rdg +6d) @ PF = 0.50 to 0.30 (4.5% rdg + 6d) (4.5% rdg + 6d) (4.5% rdg + 6d) (10% rdg +6d) @ PF = 0.30 to 0.20 (10% rdg + 6d) (10% rdg + 6d) (10% rdg + 6d) (15% rdg +6d) 1) Specified accuracy is for ACA clamp measurement at the center of jaws. When the conductor is not positioned at the jaw center, position errors introduced are: Add 1% rdg to specified accuracy for ACA measurements made WITHIN jaw marking lines (away from jaw opening) Accuracy is not specified for ACA measurement made BEYOND jaw marking lines (toward jaws opening) 2) Add 1% rdg to specified accuracy @ ACA fundamental < 5A or ACV fundamental < 90V. Accuracy is not specified @ ACA fundamental < 1A or ACV fundamental < 30V 3) Add 1% rdg to specified accuracy @ ACA fundamental < 5A or ACV fundamental < 90V. Accuracy is not specified @ ACA fundamental < 2A or ACV fundamental < 50V OPTIONAL ACCESSORIES PC Interface kit (PC connection cable with software) Amprobe(R) Test Tools website: www.Amprobe.com email: info@amprobe.com Everett, WA 98203 Tel: 877-AMPROBE Amprobe(R) Test Tools PART NUMBER RS-232 KIT2 Amprobe(R) Test Tools Europe Amprobe Test Tools Europe Beha-Amprobe GmbH In den Engematten 14 79286 Glottertal, Germany Tel.: +49 (0) 7684 8009 - 0 (c)2008 Amprobe Test Tools. All rights reserved. 7/2008 3320108 Rev A www.Amprobe.com