Not for new design. Use new F611-F612 Series. MMK RoHS Compliant * Metallized polyester * According to IEC 60384-2, DIN 44122 L TYPICAL APPLICATIONS Bypassing, signal coupling. General purpose for highest reliability. Metallized polyester film capacitor. Radial leads of tinned wire are electrically welded to the contact metal layer on the ends of the capacitor winding. Encapsulation in self-extinguishing material meeting the requirements of UL 94V-0. H 0.5 p Rated voltage U R, VDC Rated voltage U R, VAC 50 30 63 40 100 63 250 160 400 200 630 220 1000 250 Capacitance, F 0.001 -10.0 0.001 -82 0.001 -82 0.001 -39 0.001 -18 0.001 -6.8 0.001 -4.7 Capacitance tolerance 20%, 10% standard, 5%. Category temperature range -55 ... +100C Voltage derating Above +85C DC and AC voltage derating is 1.25%/C. Rated temperature +85C Climatic category IEC 60068-1, 55/100/56 DIN 40040, FME -55 ... +100C (+125C) Average relative humidity 75 % RH = 95% for 30 days per year. RH = 85% for further days limited by average value per year, occasional slight condensation permitted. Od l b TECHNICAL DATA p p d 7.5 0.4 5.0 0.4 10.0 7.5 0.4 0.4 15.0 0.4 10.0 0.4 15.0 0.4 22.5 0.4 22.5 0.4 27.5 0.4 27.5 0.4 37.5 0.5 37.5 0.5 d 0.6 0.5 0.6 0.6 0.8 0.6 0.8 0.8 0.8 0.8 0.8 1.0 1.0 std l max l std I max I 4+1 +1 4 6 -14+1 6 -14+1 6 -14+1 +1 6 -14 +1 4 6 -1 +1 4 20 20 30 20 30 30 30 30 30 30 30 30 30 b b 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.4 0.7 0.7 Z () Damp heat test Test conditions: Test criteria: T = +40C, RH = 93%, t = 56 days. C/C5%, tan 0.005 (1kHz), IR after test 0.5 x IR min. Endurance test Test conditions: Test criteria: T = +100C, U = 1.25 x (0.8 x UR), t = 2000 h. C/C 5%, tan 0.005 (1kHz) tan 0.010 (100kHz) IR after test 0.5 x IR min. 1.0 0.1 0.01 0.1 1.0 01 0.0 ENVIRONMENTAL TEST DATA 10 1 0.0 Approximately 6 nH/cm for the total length of capacitor winding and the leads. Z () 0.1 Self inductance 100 MHz 10 Resonance frequencies MMK 5 22 +400 (200) ppm/C at 1 kHz 1.0 10 Temperature coefficient 0.1 1.0 dU/dt according to article table. For peak to peak voltages lower than rated voltage (UPP < UR), the specified dU/dt can be multiplied by the factor UR/U PP. 01 Operational life > 200 000 h. Failure rate < 3 FIT, T = +40C, U = 0.5 x UR. Failure criteria according to DIN 44122. 0.0 Reliability 0.01 1 Max. 2% after a 2 year storage period at a temperature of +10 ... +40C and a relative humidity of 40...60%. 0.1 0.0 Capacitance drift 1.0 0.1 1.6 x UR VDC for 2s 10 1 Test voltage Maximum pulse steepness: B CONSTRUCTION 10 100 MHz Resonance frequencies MMK7.5 ... 37.5 Digitally signed by Jeannette Calvo DN: c=US, st=FL, l=Fort Lauderdale, o=KEMET Corp., ou=Marketing Communications, cn=Jeannette Calvo, email=jeannettecalvo@kemet.com Date: 2012.12.17 14:09:37 -05'00'