1
D
2
S
W
D2SW
Sealed Subminiature Basic Switch
Sealed Subminiature Basic
Switch Conforming to IP67
(Excluding the terminals
on terminal models)
Use of epoxy resin assures stable sealing,
making this switch ideal for places subject to
water spray or excessive dust.
Ideal for automobiles, automatic vending
machines, refrigerators, ice-making equipment,
bath equipment, hot-water supply systems, air
conditioners, and industrial equipments, which
require high environmental resistance.
Models available with UL, CSA, and VDE safety
standard compliance.
RoHS Compliant
Model Number Legend
D2SW-
@@@@@
1. Ratings
3 : 125 VAC 3 A
01 : 30 VDC 0.1 A
2. Actuator
None : Pin plunger
L1 : Hinge lever
L2 : Hinge roller lever
L3 : Simulated roller hinge lever
3. Contact form
None : SPDT
-2 : SPST-NC (Molded lead wire models only)
-3 : SPST-NO (Molded lead wire models only)
4. Terminals
H, HS : Solder terminals
D, DS : Self-clinching PCB terminals
T, TS : Quick-connect terminals (#110)
M, MS : Molded lead wires
Note: UL/CSA approved versions are available.
In this case, HS, DS, TS, MS will be added to the end
of the model number.
UL/CSA approved models have UL approved wiring
(AWG22 UL1015).
Consult your OMRON sales representative for details.
5. Length of the molded lead wire
None : 300 mm
-0 : 1,000 mm
12345
2
D2SW Sealed Subminiature Basic Switch
D
2
S
W
List of Models
Safety Standard Approved Models
Contact Form
Ratings 3 A 0.1 A
Actuator Terminals Contact form
Pin plunger
Solder terminals
SPDT
D2SW-3H D2SW-01H
Quick-connect terminals (#110) D2SW-3T D2SW-01T
PCB terminals D2SW-3D D2SW-01D
Molded lead wire terminals (300 mm)
SPDT D2SW-3M D2SW-01M
SPST-NC D2SW-3-2M D2SW-01-2M
SPST-NO D2SW-3-3M D2SW-01-3M
Molded lead wire terminals (1,000 mm) SPDT D2SW-3M-0 D2SW-01M-0
Hinge lever
Solder terminals
SPDT
D2SW-3L1H D2SW-01L1H
Quick-connect terminals (#110) D2SW-3L1T D2SW-01L1T
PCB terminals D2SW-3L1D D2SW-01L1D
Molded lead wire terminals (300 mm)
SPDT D2SW-3L1M D2SW-01L1M
SPST-NC D2SW-3L1-2M D2SW-01L1-2M
SPST-NO D2SW-3L1-3M D2SW-01L1-3M
Molded lead wire terminals (1,000 mm) SPDT D2SW-3L1M-0 D2SW-01L1M-0
Hinge roller lever
Solder terminals
SPDT
D2SW-3L2H D2SW-01L2H
Quick-connect terminals (#110) D2SW-3L2T D2SW-01L2T
PCB terminals D2SW-3L2D D2SW-01L2D
Molded lead wire terminals (300 mm)
SPDT D2SW-3L2M D2SW-01L2M
SPST-NC D2SW-3L2-2M D2SW-01L2-2M
SPST-NO D2SW-3L2-3M D2SW-01L2-3M
Molded lead wire terminals (1,000 mm) SPDT D2SW-3L2M-0 D2SW-01L2M-0
Simulated roller hinge
lever
Solder terminals
SPDT
D2SW-3L3H D2SW-01L3H
Quick-connect terminals (#110) D2SW-3L3T D2SW-01L3T
PCB terminals D2SW-3L3D D2SW-01L3D
Molded lead wire terminals (300 mm)
SPDT D2SW-3L3M D2SW-01L3M
SPST-NC D2SW-3L3-2M D2SW-01L3-2M
SPST-NO D2SW-3L3-3M D2SW-01L3-3M
Molded lead wire terminals (1,000mm) SPDT D2SW-3L3M-0 D2SW-01L3M-0
Ratings 3 A 0.1 A
Actuator Terminals Contact form
Pin plunger
Solder terminals
SPDT
D2SW-3HS D2SW-01HS
Quick-connect terminals (#110) D2SW-3TS D2SW-01TS
PCB terminals D2SW-3DS D2SW-01DS
Molded lead wire terminals (300 mm) D2SW-3MS D2SW-01MS
Hinge lever
Solder terminals D2SW-3L1HS D2SW-01L1HS
Quick-connect terminals (#110) D2SW-3L1TS D2SW-01L1TS
PCB terminals D2SW-3L1DS D2SW-01L1DS
Molded lead wire terminals (300 mm) D2SW-3L1MS D2SW-01L1MS
Hinge roller lever
Solder terminals D2SW-3L2HS D2SW-01L2HS
Quick-connect terminals (#110) D2SW-3L2TS D2SW-01L2TS
PCB terminals D2SW-3L2DS D2SW-01L2DS
Molded lead wire terminals (300 mm) D2SW-3L2MS D2SW-01L2MS
Simulated roller hinge
lever
Solder terminals D2SW-3L3HS D2SW-01L3HS
Quick-connect terminals (#110) D2SW-3L3TS D2SW-01L3TS
PCB terminals D2SW-3L3DS D2SW-01L3DS
Molded lead wire terminals (300 mm) D2SW-3L3MS D2SW-01L3MS
SPDT SPST-NC (Molded lead wire
models only)
SPST-NO (Molded lead wire
models only)
COM
(Black)
NO
(Blue)
NC
(Red)
COM
(Black)
NC
(Red)
The color in parentheses indicates
the color of the lead wire.
COM
(Black)
NO
(Blue)
Separator (Sold Separately), Terminal Connector (Sold Separately) Refer to "Basic Switch Common Accessories"
3
D2SW Sealed Subminiature Basic Switch
D
2
S
W
Contact Specifications
* Please refer to "Using Micro Loads" in "Precautions" for more information
on the minimum applicable load.
Ratings
Note. The above rating values apply under the following test conditions.
(1) Ambient temperature: 20±2°C
(2) Ambient humidity: 65±5%
(3) Operating frequency: 30 operations/min
Approved Safety Standards
UL (UL1054)/CSA (CSA C22.2 No.55)
The terminal specification for models with UL/CSA safety
standard certification is “HS”, “TS”, “DS” or “MS.”
VDE (EN61058-1)
The models in the List of Models on the previous page are not
certified for VDE standards.
Contact your OMRON representative if you require certified models.
Testing conditions: D2SW-3 3E4 (30,000 operations) T85 (0°C to 85°C)
D2SW-01 5E4 (50,000 operations) T85 (0°C to 85°C)
Characteristics
Note. The data given above are initial values.
*1. The values for dielectric strength shown are for models with a Separator
(refer to "Basic Switch Common Accessories").
*2. For the pin plunger models, the above values apply for use at the free
position and total travel position. For the lever models, they apply at the
total travel position. Close or open circuit of the contact is 1 ms max.
*3. For testing conditions, consult your OMRON sales representative.
Terminals and Shapes (Unit: mm)
Item Model D2SW-3 models D2SW-01 models
Contact
Specification Rivet Crossbar
Material Silver Gold alloy
Gap (standard value) 0.5 mm
Inrush
current
NC 20 A max. 1 A max.
NO 10 A max. 1 A max.
Minimum applicable load
(reference value) * 160 mA at 5 VDC 1 mA at 5 VDC
Model
Item
Rated voltage Resistive load
D2SW-3
models
250 VAC
125 VAC
2 A
3 A
30 VDC 3 A
D2SW-01
models
125 VAC 0.1 A
30 VDC 0.1 A
Rated voltage Model D2SW-3 D2SW-01
125 VAC
250 VAC
3 A
2 A
0.1 A
-
30 VDC 3 A 0.1 A
Rated voltage Model D2SW-3 D2SW-01
125 VAC
250 VAC
-
2 A
0.1 A
-
30 VDC 2 A 0.1 A
Item Model D2SW-3 models D2SW-01 models
Permissible operating speed 0.1 mm to 1 m/s (for pin plunger models)
Permissible
operating
frequency
Mechanical 300 operations/min
Electrical 60 operations/min
Insulation resistance
100 m
Ω
min. (at 500 VDC with insulation tester)
Contact
resistance
(initial value)
For terminal models 30 m
Ω
max. 50 m
Ω
max.
For molded lead wire
models (300mm) 50 m
Ω
max. 70 m
Ω
max.
For molded lead wire
models (1,000mm) 200 m
Ω
max. 250 m
Ω
max.
Dielectric
strength *1
Between terminals of
the same polarity
1,000 VAC 50/60 Hz
for
1 min
600 VAC 50/60 Hz
for
1 min
Between current-carrying
metal parts and ground
1,500 VAC 50/60 Hz for 1 min
Between terminals and
non-current-carrying
metal parts
1,500 VAC 50/60 Hz for 1 min
Vibration
resistance *2 Malfunction 10 to 55 Hz, 1.5 mm double amplitude
Shock
resistance
Destruction 1,000 m/s
2
{approx. 100G} max.
Malfunction *2 300 m/s
2
{approx. 30G} max.
Durability * 3
Mechanical 5,000,000 operations min. (60 operations/min)
Electrical
200,000 operations min.
(30 operations/min)
(125 VAC 3 A)
100,000 operations min.
(30 operations/min)
(250 VAC 2 A)
200,000 operations min.
(30 operations/min)
Degree of
protection
For terminal models
IEC IP67 (excluding the terminals on terminal models)
For molded lead wire
models IEC IP67
Degree of protection against electric
shock Class I
Proof tracking index (PTI) 175
Ambient operating temperature
–40°C to
+
85°C (at ambient humidity of 60% max.)
(with no icing or condensation)
Ambient operating humidity 95% max. (for
+
5°C to
+
35°C)
Weight
Approx. 2 g (for pin plunger models with terminals)
Solder terminals
<PCB Mounting Dimensions (Reference)>
Quick-connect terminals (#110) PCB terminals
2.9
7.3
3.3
±0.1
0.5
6.4
±0.2
R0.8
1.6
3.2
5.15
1.6
1.8
9.5
±0.1
8.5
±0.2
15.5
±0.2
18.7
±0.2
0.55
19.8
±0.2
16.1
±0.2
8.8
±0.2
PCB thickness
t=1.6 mm
3-1.35 dia. to 1.5 holes
0.5
3.9
1.3
6.4±0.2
1.8±0.1
2.9
7.2
3.3±0.1
0.7
0.8
1.2
5.15 9.5±0.1
8.8±0.2
16.1±0.2
1.85
19.8±0.2
4
D2SW Sealed Subminiature Basic Switch
D
2
S
W
Mounting Holes (Unit: mm)
Dimensions (Unit: mm) slash Operating Characteristics
The illustrations and dimensions are for models with solder terminals. Refer to "Terminals and Shapes" of the previous page for models with quick-connect terminals
(#110) and PCB terminals.
(Note. The dimensions not described are the same as those of models with pin plungers.)
The @ is replaced with the code for the terminal that you need. See the "List of Models" for available combinations of models.
Note 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Note 2. The operating characteristics are for operation in the A direction ( ).
9.5
±0.1
2-2.4 dia. mounting holes
or M2.3 screw holes
Models with terminals
7.5
±0.1
1.8 dia.
10.1
2.35
+0.1
dia. holes
-0.05
2.35
+0.1
-0.05
7.7
PT
OP
2.9
0.5
R0.8
1.6
3.2
5.15
1.6
1.8
7.3
3.3
±0.1
9.5
±0.1
8.5
±0.2
2.5
±0.07
dia.
15.5
±0.2
18.7
±0.2
0.55
19.8
±0.2
6.4
±0.2
A
Pin Plunger Models
D2SW-3@
D2SW-01@Operating Force OF Max.
Releasing Force RF Min.
1.77 N {180 gf}
0.29 N {30 gf}
Pretravel PT Max.
Overtravel OT Min.
Movement Differential MD Max.
0.6 mm
0.5 mm
0.1 mm
Operating Position OP 8.4±0.3 mm
Hinge Lever Models
D2SW-3L1@
D2SW-01L1@Operating Force OF Max.
Releasing Force RF Min.
0.59 N {60 gf}
0.06 N {6 gf}
Overtravel OT Min.
Movement Differential MD Max.
1.0 mm
0.8 mm
Free Position FP Max.
Operating Position OP
13.6 mm
8.8±0.8 mm
A
OP
14.5 5.9
3.6
t=0.3*
*Stainless-steel lever
FP
Simulated Roller Hinge Lever Models
D2SW-3L3
@
D2SW-01L3@Operating Force OF Max.
Releasing Force RF Min.
0.59 N {60 gf}
0.06 N {6 gf}
Overtravel OT Min.
Movement Differential MD Max.
1.0 mm
0.8 mm
Free Position FP Max.
Operating Position OP
15.5 mm
10.7±0.8 mm
A
OP
15.8 5.9
3.6
t=0.3* R1.3
*Stainless-steel lever
FP
Hinge Roller Lever Models
D2SW-3L2@
D2SW-01L2@ Operating Force OF Max.
Releasing Force RF Min.
0.59 N {60 gf}
0.06 N {6 gf}
Overtravel OT Min.
Movement Differential MD Max.
1.0 mm
0.8 mm
Free Position FP Max.
Operating Position OP
19.3 mm
14.5±0.8 mm
A
OP
14.5
5.9
4.8x3.2 *2 dia.
t=0.3*1
*1. Stainless-steel lever
*2. Polyacetal resin roller
FP
5
D2SW Sealed Subminiature Basic Switch
D
2
S
W
Pin plunger models are shown as representatives. Dimensions and operation characteristics of other actuator models are the same as those of terminal models.
The illustration and drawing shown is the SPDT model. SPST-NC model and SPST-NO model are omitted in the illustration below.
Note 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Note 2. The operating characteristics are for operation in the A direction ( ).
Models with lead wires
Pin Plunger Models
D2SW-3M
D2SW-3M-0
D2SW-01M
D2SW-01M-0
300 mm type
Dimensions
1,000 mm type
300±10L 1,000±30
7.5
±0.1
1.8 dia.
16.4
2.35
+0.1
dia. holes
-0.05
2.35
+0.1
-0.05
16.9
L
9.5
±0.1
5
21.2
AV0.5f molded lead
wire (red)*
AV0.5f molded lead
wire (blue)*
AV0.5f molded lead
wire (black)*
5.15
0.7
PT
OP
2.9
9.2
6.4
±0.2
A
2.5
±0.07
dia.
* UL/CSA approved models have UL approved wiring
(AWG22 UL1015).
Operating Force OF Max.
Releasing Force RF Min.
1.77 N {180 gf}
0.29 N {30 gf}
Pretravel PT Max.
Overtravel OT Min.
Movement Differential MD Max.
0.6 mm
0.5 mm
0.1 mm
Operating Position OP 8.4±0.3 mm
6
D2SW Sealed Subminiature Basic Switch
D
2
S
W
Precautions
Please refer to "Basic Switches Common Precautions" for correct use.
Degree of Protection
Do not use the Switch underwater.
The Switch was tested and found to meet the conditions
necessary to meet the following standard, however, the test
checks for water intrusion after immersion for a specified time
period, not for switching operation underwater.
JIS C0920:
Degrees of protection provided by enclosures of electrical
apparatus (IP Code)
IEC 60529:
Degrees of protection provided by enclosures (IP Code)
Degree of protection:IP67
(check water intrusion after immersion
for 30 min submerged 1 m underwater)
Protection Against Chemicals
Prevent the Switch from coming into contact with oil or
chemicals.
Otherwise, damage to or deterioration of Switch materials may
result.
Soldering
Connecting to Solder Terminals
When soldering the lead wire to the terminal, first insert the
lead wire conductor through the terminal hole and then
conduct soldering.
Complete the soldering at the iron tip temperature between
350 to 400°C within 5 seconds, and do not apply any external
force for 1 minute after soldering. Soldering at a excessively
high temperature or soldering for more than 5 seconds may
deteriorate the characteristics of the Switch.
Connecting to Quick-connect Terminals
Wire the quick-connect terminals (#110) with receptacles.
Insert the terminals straight into the receptacles. Applying
excessive external force laterally may cause deformation of
terminals and may damage the housings.
Connecting to PCB terminals
When using automatic soldering baths, we recommend
soldering at 260±5°C within 5 seconds. Make sure that the
liquid surface of the solder does not flow over the edge of the
board.
When soldering terminals manually, complete the soldering at
the iron tip temperature between 350 to 400°C within 5
seconds, and do not apply any external force for 1 minute after
soldering. When applying solder, keep the solder away from
the case of the Switch and do not allow solder or flux to flow
into the case.
Mounting
Use M2.3 mounting screw with plane washers or spring washers
to securely mount the Switch. Tighten the screws to a torque of
0.23 to 0.26 N·m {2.3 to 2.7 kgf·cm}.
Operating Body
With the pin plunger models, set the Switch so that the plunger
can be pushed in from directly above. Since the plunger is
covered with a rubber cap, applying a force from lateral
directions may cause damage to the plunger or reduction in the
sealing capability.
Handling
Handle the Switch carefully so as not to break the sealing
rubber.
Using Micro Loads
Using a model for ordinary loads to open or close the contact of
a micro load circuit may result in faulty contact. Use models that
operate in the following range. However, even when using micro
load models within the following operating range, if inrush
current occurs when the contact is opened or closed, it may
increase the contact wear and so decrease durability. Therefore,
insert a contact protection circuit where necessary. The N-level
reference value applies for the minimum applicable load. This
value indicates the malfunction reference level for the reliability
level of 60% (λ60).
(JIS C5003)
The equation, λ60=0.5×10-6/operations indicates that the
estimated malfunction rate is less than operations with
a reliability level of 60%.
Cautions Correct Use
1
2,000,000
30
24
12
5
0
1 10 100 1,000
Current (mA)
0.1
1 mA
Operating
range for
general-load
models
D2SW-3
Operating range for
micro load models
D2SW-01
26 mA0.16 mA
100 mA 160 mA
100 mA
Voltage (V)
7
D2SW Sealed Subminiature Basic Switch
D
2
S
W
Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Cat. No. C097-E1-05
0417(0207)(O)
Note: Do not use this document to operate the Unit.
OMRON Corporation
Electronic and Mechanical Components Company Contact: www.omron.com/ecb