NEMIC-LAMBDA
JWS 100
A159-01-01A
MODEL
ITEMS
1 Nominal Output Voltage V
2 Maximum Output Current A
3 Maximum Output Power W
4 Efficiency (Typ) (*1) %
5 Input Voltage Range (*2) -
6
Input Current (100/200VAC)(Typ) (*1)
A
7 Inrush Current(Typ) -
8 PFHC -
9
Power Factor (100/200VAC)(Typ) (*1)
-
10 Output Voltage Range V
11 Maximum Ripple & Noise 0 ~ +60°C mV
(*3) -10 ~ 0°C mV
12
Maximum Line Regulation
(*4) mV
13
Maximum Load Regulation
(*5) mV
14 Temperature Coefficient -
15 Over Current Protection (*6) A
16 Over Voltage Protection (*7) V
17 Hold-up Time (Typ) (*8) -
18 Leakage Current (*9) -
19 Remote Sensing -
20 Parallel Operation -
21 Series Operation -
22 Operating Temperature (*10) -
23 Operating Humidity -
24 Storage Temperature -
25 Storage Humidity -
26 Cooling -
27 Withstand Voltage -
28 Isolation Resistance -
29 Vibration -
30 Shock (In package) -
31 Safety (*11) -
32 Conducted Emission -
33 Radiated Emission -
34 Weight(Typ.) g
35 Size (W x H x D) mm
*Read instruction manual carefully, before using the power supply unit.
=NOTES=
*1. At 100/200VAC, Ta=25°C and maximum output power.
*2. For cases where conformance to various safety specs (UL, CSA, EN) are required,
input voltage range will be 100 ~ 240VAC(50/60Hz).
*3. Measure with EIAJ RC-9131 probe, Bandwise of scope :100MHz.
*4. 85 ~ 265VAC , constant load.
*5. No load-Full load, constant input voltage.
*6. Constant current limit with automatic recovery.
*7. OVP circuit will shut down output, manual reset (Line recycle).
*8. At 100/200VAC nominal output voltage and maximum output current.
*9. Measured by the each measuring method of UL,CSA,EN and DENTORI(at 60Hz).
*10.
Ratings - Derating at standard mounting.
- Load (%) is percent of maximum output power or maximum output current, whichever is greater.
- As for other mountings, refer to derating curve (A159-01-02_).
*11.
As for DENTORI, built to meet at 100VAC.
SPECIFICATIONS
50 x 92 x 188 ( Refer to Outline Drawing )
Built to meet DENTORI.
650
At no operating, 10 ~ 55Hz (Sweep for 1min)
19.6m/s
2
Constant, X,Y,Z 1hour each.
Less than 196.1m/s
2
Approved by UL1950, CSA950, EN60950,VDE0160.
Convection Cooling
Input - FG : 2kVAC (20mA), Input - Output : 3kVAC (20mA)
Output - FG : 500VAC (100mA) for 1min
More than 100M
at 25°C and 70%RH Output - FG … 500VDC
-10 ~+60°C ( -10 ~+50°C:100%, +60°C:60%)
30 ~ 90%RH (No dewdrop)
-30 ~ +85°C
10 ~ 95%RH (No dewdrop)
0.75mA MAX, 0.2mA(Typ) at 100VAC / 0.44mA(Typ) at 230VAC
Possible
-
Possible
27.6~32.4
2.2 ~
55.2~64.8
20ms
Less than 0.02%/°C
21 ~
3.79~4.95
21 ~
5.75~6.75
8.92 ~
13.8~16.2
7.35 ~
17.3~20.3
4.72 ~
180
96
150
43.2~52.8
200
240
192
240
180
48
96
13.5~16.5
150
180
60
120
160
20
40
4.5~5.5
120
160
20
40
Built to meet EN61000-3-2
0.99/0.95
2.85~3.63
120
10.8~13.2
150
21.6~26.4
150
85 ~ 265VAC (47 ~ 63Hz) or 120 ~ 330VDC
1.0/0.5
1.4/0.7
14A at 100VAC, 28A at 200VAC, Ta=25°C, Cold Start
4.5
108
79
JWS100
-48
48
2.1
100.8
79
8.5
102
76
JWS100
-15
15
7
105
77
20
66
67
JWS100
-5
5
20
100
75
JWS100
-3
3.3
JWS100
-12
12
JWS100
-24
24
NEMIC-LAMBDA
JWS 100
A159-01-02
Ta(°C)
MOUNTING A
MOUNTING B
MOUNTING C
-10 ~+40
100
100
100
45
100
80
80
50
100
60
60
55
80
-
-
60
60
-
-
OUTPUT DERATING
LOAD(%)
MOUNTING B
MOUNTING C
DON'T USE
OUTPUT DERATING CURVE
0
20
40
60
80
100
-10 0 10 20 30 40 50 60
Ta(°C)
LOAD(%)
MOUNTING A
MOUNTING B,C
MOUNTING A
(STANDARD MOUNTING)
DON'T USE
NEMIC-LAMBDA
JWS 100
A159-01-03A
MODEL
ITEMS
1
Nominal Output Voltage
V
2 Maximum Output Current A
3 Maximum Output Power W
4 Efficiency (Typ) (*1) %
5
Input Voltage Range
(*2)
-
6
Input Current (100/200VAC)(Typ) (*1)
A
7 Inrush Current(Typ) -
8 PFHC -
9
Power Factor (100/200VAC)(Typ) (*1)
-
10
Output Voltage Range
V
11 Maximum Ripple & Noise 0 ~ +60°C mV
(*3) -10 ~ 0°C mV
12
Maximum Line Regulation
(*4)
mV
13
Maximum Load Regulation
(*5)
mV
14 Temperature Coefficient -
15 Over Current Protection (*6) A
16
Over Voltage Protection
(*7)
V
17 Hold-up Time (Typ) (*8) -
18
Leakage Current
(*9)
-
19
Remote Sensing
-
20 Parallel Operation -
21 Series Operation -
22
Operating Temperature
(*10)
-
23
Operating Humidity
-
24
Storage Temperature
-
25
Storage Humidity
-
26
Cooling
-
27
Withstand Voltage
-
28 Isolation Resistance -
29
Vibration
-
30
Shock (In package)
-
31 Safety (*11) -
32 Conducted Emission -
33 Radiated Emission -
34
Weight(Typ.)
g
35 Size (W x H x D) mm
*Read instruction manual carefully, before using the power supply unit.
=NOTES=
*1. At 100/200VAC, Ta=25°C and maximum output power.
*2. For cases where conformance to various safety specs (UL, CSA, EN) are required,
input voltage range will be 100 ~ 240VAC(50/60Hz).
*3. Measure with EIAJ RC-9131 probe, Bandwise of scope :100MHz.
*4. 85 ~ 265VAC , constant load.
*5.
No load-Full load, constant input voltage.
*6. Constant current limit with automatic recovery.
*7. OVP circuit will shut down output, manual reset (Line recycle).
*8.
At 100/200VAC nominal output voltage and maximum output current.
*9.
Measured by the each measuring method of UL,CSA,EN and DENTORI(at 60Hz).
*10.
Ratings - Derating at standard mounting.
- Load (%) is percent of maximum output power or maximum output current, whichever is greater.
- As for other mountings, refer to derating curve (A159-01-02_).
*11.
As for DENTORI, built to meet at 100VAC.
SPECIFICATIONS
JWS100
-9
9
11.2
100.8
75
85 ~ 265VAC (47 ~ 63Hz) or 120 ~ 330VDC
1.4/0.7
14A at 100VAC, 28A at 200VAC, Ta=25°C, Cold Start
Built to meet EN61000-3-2
0.99/0.95
8.1~9.9
150
180
36
72
Less than 0.02%/°C
11.8 ~
10.4~12.2
20ms
0.75mA MAX, 0.2mA(Typ) at 100VAC / 0.44mA(Typ) at 230VAC
Possible
-
Possible
-10 ~+60°C ( -10 ~+50°C:100%, +60°C:60%)
30 ~ 90%RH (No dewdrop)
-30 ~ +85°C
10 ~ 95%RH (No dewdrop)
Convection Cooling
Input - FG : 2kVAC (20mA), Input - Output : 3kVAC (20mA)
Output - FG : 500VAC (100mA) for 1min
More than 100M
at 25°C and 70%RH Output - FG ... 500VDC
At no operating, 10 ~ 55Hz (Sweep for 1min)
19.6m/s
2
Constant, X,Y,Z 1hour each.
Less than 196.1m/s
2
Approved by UL1950, CSA950, EN60950,VDE0160.
50 x 92 x 188 ( Refer to Outline Drawing )
Built to meet DENTORI.
650