CSM_H7GP_DS_E_4_5
1
Total Counter/Time Counter (DIN 48 x 24)
H7GP
DIN 48 x 24-mm Total Counter/Time Counter
with Easy-to-read Displays and Water and
Oil Resistance Equivalent to IP66
High-visibility, negative transmissive LCD display with 8.5-mm-
high characters and built-in red LED backlight at low power
consumption.
IP66 with oil resistance and NEMA 4 protection achieved by
unifying the front with the case and by using oil-resistant parts
and materials.
Compact (80 mm) body.
Just change a switch setting for either an NPN or PNP input.
Supports both external resetting and manual resetting.
Finger-protection terminal block cover prevents electrical shock
and conforms to VDE0106, Part 100.
Certified for UL and CSA safety standards.
Complies with EMC standards (EN 61326) and CE Marking.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Model Number Structure
Model Number Legend
1. Classification
C: Total counter
T: Time counter
2. Supply Voltage
None: 100 to 240 VAC
D: 12 to 24 VDC
3. Case Color of Front Section
None: Light gray (Munsell 5Y7/1)
B: Black
Ordering Information
List of Models
Total counter
Time counter
1 2 3
H7GP-@@@
Supply voltage 6-digit total counter
Light gray Black
100 to 240 VAC H7GP-C H7GP-CB
12 to 24 VDC H7GP-CD H7GP-CDB
Supply voltage 6-digit time counter
Light gray Black
100 to 240 VAC H7GP-T H7GP-TB
12 to 24 VDC H7GP-TD H7GP-TDB
H7GP
2
Specifications
Ratings
Note: 1. Contains 20% ripple (p-p) max.
2. Only a non-voltage input (NPN transistor) is possible for the key protection input. The key protection input will be a non-voltage input even
if the NPN/PNP input mode is set to PNP. Key protection is used to prohibit operating the Reset Key. The reset input terminals will still be
functional.
Item 6-digit total counter 6-digit time counter
H7GP-C H7GP-CD H7GP-T H7GP-TD
Rated supply voltage 100 to 240 VAC (50/60 Hz) 12 to 24 VDC (see note 1) 100 to 240 VAC (50/60 Hz) 12 to 24 VDC (see note 1)
External power supply 50 mA at 12 VDC --- 50 mA at 12 VDC ---
Operating voltage range 85% to 110% of rated supply voltage
Power consumption 100 to 240 VAC: 6.5 VA max.
12 to 24 VDC: 0.6 W max.
Dimensions 48 x 24 x 80 mm (W x H x D)
Mounting method Flush mounting
External connections Screw terminals
Degree of protection Panel surface: IP66 with oil resistance and NEMA Type 4 (indoors).
Display 7-segment, negative transmissive LCD (with red backlight)
Digits 6 digits (8.5-mm-high characters)
Input mode Up (increment) Accumulative
Max. counting speeds 30 Hz or 5 kHz (selected via DIP switch) ---
Counting range 0 to 999999 ---
Time specification --- 0.1 to 99999.9 h/1 s to 99 h 59 min 59 s
(selected via DIP switch)
Timing accuracy --- ±100 ppm (–10°C to 55°C)
Memory backup EEP-ROM (overwrites: 200,000 times min.) that can store data for 20 years min.
Input Input signals Count, reset, and key protection (see note 2) Start, reset, and key protection (see note 2)
Input method No-voltage input (NPN transistor input) or voltage input (PNP transistor input) (selected via DIP switch)
Count, reset,
start
No-voltage input (NPN transistor input)
Short-circuit (ON) impedance: 1 kΩ max.
Short-circuit (ON) residual voltage:2 VDC max.
Open (OFF) impedance: 100 kΩ min.
Voltage input (PNP transistor input)
Short-circuit (ON) impedance: 1 kΩ max.
ON voltage: 9 to 24 VDC
OFF voltage: 5 VDC max.
Open (OFF) impedance: 100 kΩ min.
Key protection No-voltage input (NPN transistor input)
Short-circuit (ON) impedance: 1 kΩ max.
Short-circuit (ON) residual voltage:0.5 VDC max.
Open (OFF) impedance: 100 kΩ min.
Input re-
sponse
speed
Reset 20 or 1 ms (automatically switched according to counting
speed)
20 ms
Start --- 20 ms
Key protection Approx. 1 s Approx. 1 s
Reset system External and manual resets
H7GP
3
Characteristics
Note: 1. Industrial electromagnetic environment (EN/IEC 61326-1 Table 2)
2. UL508 and CAN/CSA-C22.2 No.14 certification conditions
Power supply 100 to 240VAC types
Ambient temperature 30°C Single mounting
Power supply 12 to 24VDC types
Ambient temperature 40°C Single mounting
Insulation resistance 100 MΩ min. (at 500 VDC)
Dielectric strength 2,000 VAC, 50/60 Hz for 1 min between current-carrying terminal and exposed non-current-carrying metal parts
(AC model)
1,000 VAC, 50/60 Hz for 1 min between current-carrying terminal and exposed non-current-carrying metal parts
(DC model)
2,000 VAC, 50/60 Hz for 1 min between power terminals and control input terminals (AC model)
Impulse withstand voltage 3 kV (between power terminals) (1 kV for 12-to-24-VDC models)
4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) (1.5 kV for 12-to-24-VDC
models)
Noise immunity ±1.5 kV (between AC power terminals), ±480 V (between DC power terminals),
±480 V (between input terminals);
square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise)
Static immunity Display: Malfunction:8 kV
Destruction:15 kV
DIP switch: Malfunction:4 kV
Destruction:8 kV
Vibration resistance Destruction: 10 to 55 Hz with 0.75-mm single amplitude, 2 hours each in three directions
Malfunction: 10 to 55 Hz with 0.5-mm single amplitude, 10 minutes each in three directions
Shock resistance Destruction: 294 m/s2 each in three directions
Malfunction: 196 m/s2 each in three directions
Ambient temperature Operating: –10°C to 55°C (with no icing)
Storage: –25°C to 65°C (with no icing)
Ambient humidity Operating: 35% to 85%
EMC (EMI) EN61326-1 (note 1.)
Emission Enclosure: EN55011 Group 1 class A
Emission AC Mains: EN55011 Group 1 class A
(EMS) EN61326-1 (note 1.)
Immunity ESD: EN61000-4-2: 4 kV contact discharge (level 2)
8 kV air discharge (level 3)
Immunity RF-interference: EN61000-4-3: 10 V/m (Amplitude-modulated, 80 MHz to 1 GHz) (level 3);
10 V/m (Pulse-modulated, 900 MHz ±5 MHz) (level 3)
Immunity Conducted Disturbance: EN61000-4-6: 10 V (0.15 to 80 MHz) (according to EN61000-6-2)
Immunity Burst: EN61000-4-4: 2 kV power-line (level 3);
2 kV I/O signal-line (level 4)
Immunity Surge: EN61000-4-5: 1 kV line to lines (power and output lines) (level 2);
2 kV line to ground (power and output lines) (level 3)
Immunity Voltage Dip/Interruption: EN61000-4-11: 0.5 cycle, 100% (rated voltage)
Approved standards UL508 (note 2), CSA C22.2 No.14 (note 2), conforms to EN61010-1, VDE0106/P100
Case color Rear section: Gray smoke; Front section: 5Y7/1 (light gray) or N1.5 (black)
Weight Approx. 75 g
H7GP
4
Connections
Terminal Arrangement
Note: Non-contact input is also available.
5678
4
321
0 V
12 VDC0 V
5678
4
321
12 VDC0 V
5678
4
321
5678
4
321
0 V
AC Models
H7GP-C H7GP-T
DC Models
H7GP-CD H7GP-TD
Unused
Unused Unused
12 to 24 VDC
PNP mode
NPN mode
100 to 240 VAC
Unused
NPN mode
PNP mode
100 to 240 VAC
Unused
NPN mode
PNP mode
Unused
Unused Unused
12 to 24 VDC
PNP mode
NPN mode
External power supply
12 VDC 50 mA max.
Power
supply
Power
supply
Key protection
input
Reset
input
Count
input
Power
supply
Key protection
input
Reset
input
Count
input
External power supply
12 VDC 50 mA max.
Power
supply
Power
supply
Key protection
input Reset
input
Count
input
Power
supply
Key protection
input
Reset
input
Start
input
H7GP
5
Operation
DIP Switch Settings
Set all DIP switches before mounting the Counter to a control panel.
All switches are set toward the display panel before shipping.
H7GP-C/-CD
H7GP-T/-TD
Note: 1. When the setting has been changed, turned power off and
on to continue. The display will show “0” when the power is
turned back on.
2. The decimal point will flash every second when “99999.9 h”
is set.
Operating Modes
Nomenclature
Switch Item Function
3 (On right side
from front)
Input mode (note
1)
Display side NPN
Terminal side PNP
4 (On left side
from front)
Counting speed
(note 1)
Display side 30 Hz
Terminal side 5 kHz
Switch Item Function
3 (On right side
from front)
Input mode
(note 1)
Display side NPN
Te r m i n a l s i d e P N P
4 (On left side
from front)
Time range
(note 1)
Display side 99999.9h
(note 2)
Terminal side 99 h 59 min
59 s
0 0.0h
999999
Total Counters Time Counters
Reset input
Count input
Display
Start input
Display
Reset input
99999.9 h
(see note)
Note: The count value will return to "0" when "999999" is
exceeded.
The display and output are turned OFF when the power
supply turns OFF, but the count value is stored internally.
Note: Display values are shown for full scale set to 99999.9 h.
The count value will return to "0" when "99999.9" is
exceeded.
The display and output are turned OFF when the power
supply turns OFF, but the count value is stored internally.
1. Reset Key
Resets the count value, but will not operate while
the keys are protected.
2. Key Protection Indicator
Lit while the keys are protected. (Reset Key is
disabled.).
3. NPN/PNP DIP Switch
(Count or start with reset)
When the setting has been changed, turned power
off and on to continue. The display will show "0"
when the power is turned back on. See below for
details.
4. Counting Speed DIP Switch (H7GP-C)
Time Range DIP Switch (H7GP-T)
When the setting has been changed, turned power
off and on to continue. The display will show "0"
when the power is turned back on. Refer to DIP
Switch Setting for details.
4
2
1
3
H7GP
6
Dimensions
Note: All units are in millimeters unless otherwise indicated.
In the interest of product improvement, specifications are subject to change without notice.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Panel Cutouts
With Flush Mounting Bracket
Terminal cover (provided)
Panel
M3.5 terminal screw
H7GP-C
H7GP-T
Y92S-32 rubber
packing (provided)
Y92F-32 flush mounting
adaptor (provided)
Panel cutouts are as shown below
(according to DIN43700).
Note: 1. The mounting panel thickness should
be 1 to 6 mm.
2. Water resistance will be lost if
Counters are mounted side-by-side.
4. When horizontally mounting Counters
side-by-side, leave at least 50 mm
between any two Counters.
3. The terminal screws are M3.5.
(Theeffective thread length is 6 mm.)
22.2 +0.3
0
45 +0.6
0
22.2 +0.3
0
45 +0.6
0
5.0 min.
50 min.
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omrons analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyers request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the users programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2016.7
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2016 All Right Reserved.