ISL6118 (R) Data Sheet March 2004 FN9008.2 Dual Power Supply Controller Features The ISL6118 is a dual channel, fully independent overcurrent (OC) fault protection IC for the +2.5V to +5.5V environment. This device features internal current monitoring, accurate current limiting, integrated power switches and current limited delay to latch-off for system protection. * 80m Integrated Power N-Channel MOSFET Switches The ISL6118 current sense and limiting circuitry sets the current limit to a nominal 0.6A, which is well suited for the 3.3V AUX ACPI application. The ISL6118 is the ideal companion chip to the HIP1011D and HIP1011E dual PCI hot plug controllers. Together these and the ISL6118 fully control the four legacy PCI voltages (12V, +3.3V, +5V) and the 3.3V AUX, respectively, for power control of two PCI slots compliant to PCI Bus Power Management Interface Spec Rev 1.1. Designed to be co-located with the HIP1011D on the motherboard, the ISL6118 provides OC fault notification, accurate current limiting and a consistent timed latch-off thus isolating and protecting the voltage bus in the presence of an OC event or short circuit during all PCI Bus Power States as defined by the PCI specification. The 12ms time to latch-off is independent of the adjoining switch's electrical or thermal condition and the OC response time is inversely related to the OC magnitude. * Disabled Output Internally Pulled Low Each ISL6118 incorporates in a single 8-lead SOIC package two 80m N-channel MOSFET power switches for power control. Each switch is driven by a constant current source giving a controlled ramp up of the output voltage. This provides a soft start turn-on eliminating bus voltage drooping caused by inrush current while charging heavy load capacitances. Independent enabling inputs and fault reporting outputs for each channel are compatible with 3V and 5V logic to allow external control and monitoring. The ISL6118 undervoltage (UV) feature prevents turn-on of the outputs unless the correct ENABLE state and VIN > 2.5V are present. During initial turn-on the ISL6118 prevents fault reporting by blanking the fault signal. Rising and falling outputs are current-limited voltage ramps so that both the inrush current and voltage slew rate are limited, independent of load. This reduces supply droop due to surge and eliminates the need for external EMI filters. During operation, once an OC condition is detected the appropriate output is current limited for 12ms to allow transient conditions to pass. If still in current limit after the current limit period has elapsed, the output is latched off and the fault is reported by pulling the corresponding FAULT low. The FAULT signal is latched low until reset by the ENABLE signal being de-asserted at which time the FAULT signal will clear. 1 * Accurate Current Sensing and Limiting * 12ms Fault Delay to Latch-Off, No Thermal Dependency * 2.5V to 5.5V Operating Range * Undervoltage Lockout * Controlled Turn-On Ramp Time * Channel Independent Fault Output Signals * Channel Independent Logic Level Enable High Inputs (ISL6118H) or Enable Low Inputs (ISL6118L) * Pb-Free Package Options Available * Tape & Reel Packing with `-T' Part Number Suffix Applications * ACPI 3.3V AUX Control * Electronic Circuit Limiting and Breaker Ordering Information TEMP. RANGE (C) PART # PKG. PKG. DWG. # ISL6118LIB -40 to 85 8 Ld SOIC M8.15 ISL6118LIBZA (Note) -40 to 85 8 Ld SOIC (Pb-free) M8.15 ISL6118HIB -40 to 85 8 Ld SOIC M8.15 ISL6118HIBZA (Note) -40 to 85 8 Ld SOIC (Pb-free) M8.15 ISL6118EVAL1 ISL6118 Evaluation Platform ISL6AHPEVAL1 ACPI (HIP1011D and ISL6118H) Evaluation Platform NOTE: Intersil Pb-free products employ special Pb-free material sets; molding compounds/die attach materials and 100% matte tin plate termination finish, which is compatible with both SnPb and Pb-free soldering operations. Intersil Pb-free products are MSL classified at Pb-free peak reflow temperatures that meet or exceed the Pb-free requirements of IPC/JEDEC J Std-020B. Pinout ISL6118 (SOIC) TOP VIEW GND 1 8 FAULT_1 VIN 2 7 OUT_1 ENABLE_1 3 6 OUT_2 ENABLE_2 4 5 FAULT_2 CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures. 1-888-INTERSIL or 321-724-7143 | Intersil (and design) is a registered trademark of Intersil Americas Inc. Copyright (c) Intersil Americas Inc. 2004. All Rights Reserved All other trademarks mentioned are the property of their respective owners. ISL6118 Simplified Block Diagram CHANNEL 1 LIKE CHANNEL 2 GND FAULT_1 VIN OUT_1 Q-PUMP POR EN_1 CURRENT AND TEMP. MONITORING, GATE AND OUTPUT CONTROL LOGIC EN_2 OUT_2 FAULT_2 Pin Descriptions PIN NO. DESIGNATOR 1 GND IC Reference 2 VIN VIN provides chip bias voltage. At VIN < 2.5V chip functionality is disabled, FAULT_X latch Chip Bias, Controlled is cleared and floating and OUT is held low. Supply Input, Undervoltage Lock-Out 3, 4 ENABLE_1, 2/ ENABLE_1, 2 5, 8 6, 7 FUNCTION Channel Enable/ Enable not Inputs FAULT OUT_2, 1 Channel 2, 1 Overcurrent Fault not Indicator OUT_2, 1 DESCRIPTION Enables/Disables switch. Channel overcurrent fault-not indicator. FAULT floats and is disabled until VIN > 2.5V. This output is pulled low after the OC timeout period has expired and stays latched until ENABLE is deasserted. Channel 2,1 Controlled Channel voltage output, connect to load to protect. Upon an OC condition OUT is current Supply Output limited to 0.6A. Current limit response time is within 200s. This output will remain in current limit for a determined time before being latched off. 2 ISL6118 Absolute Maximum Ratings Thermal Information Supply Voltage (VIN to GND). . . . . . . . . . . . . . . . . . . . . . . . . . . 6.0V EN, FAULT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.3V to 6V OUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GND-0.3V to VIN +0.3V Output Current . . . . . . . . . . . . . . . . . . . . . . . Short Circuit Protected ESD Rating Human Body Model (Per MIL-STD-883 Method 3015.7) . . . . 3KV Thermal Resistance (Typical, Note 1) JA (C/W) SOIC Package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116 Maximum Junction Temperature . . . . . . . . . . . . . . . . . . . . . . . 150C Maximum Storage Temperature Range . . . . . . . . . . . -65C to 150C Maximum Lead Temperature (Soldering 10s) . . . . . . . . . . . . . 300C (SOIC - Lead Tips Only) Operating Conditions Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . .-40C to 85C Supply Voltage Range (Typical). . . . . . . . . . . . . . . . . . 2.7V to 5.5V CAUTION: Stresses above those listed in "Absolute Maximum Ratings" may cause permanent damage to the device. This is a stress only rating and operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. NOTES: 1. JA is measured with the component mounted on a high effective thermal conductivity test board in free air. See Tech Brief TB379 for details. 2. All voltages are relative to GND, unless otherwise specified. Electrical Specifications Supply Voltages = 3.3V, TA = TJ = -40 to 85C, Unless Otherwise Specified PARAMETER SYMBOL TEST CONDITIONS MIN TYP MAX UNITS VIN = 2.7V, IOUT = 0.4A, TA = TJ = 25C - 90 105 m TA = TJ = 85C - 115 130 m POWER SWITCH ISL6118 On Resistance at 2.7V rDS(ON)_27 VIN = 3.3V, IOUT = 0.4A, TA = TJ = 25C - 80 100 m TA = TJ = 85C - 115 130 m VIN = 5V, IOUT = 0.4A, TA = TJ = 25C - 80 95 m TA = TJ = 85C - 115 130 m VIN = 5V, Switch Disabled, 50A Load - 300 450 mV t_vout_rt RL = 10, CL = 0.1F, 10%-90% - 8 - V/ms Slow VOUT Turn-off Rate t_svout_offt RL = 10, CL = 0.1F, 90%-10% - 8 - V/ms Fast VOUT Turn-off Rate t_fvout_offt RL = 1, CL = 0.1F, 90%-10% - 4 - V/s 0.45 0.6 0.75 A ISL6118 On Resistance at 3.3V rDS(ON)_33 ISL6118 On Resistance at 5.0V rDS(ON)_50 Disabled Output Voltage VOUT_DIS OUT Rising Rate CURRENT CONTROL Current Limit, VIN = 3.3V - 5V Ilim VOUT = 0.8V tsettIlim RL = 3, CL= 0.1F to within 10% of CR - 2 - ms tsettIlim_sev RL < 1, CL= 0.1F to within 10% of CR - 100 - s tOC_loff ISL6118X, TJ = 25C - 12 - ms Fault Output Voltage VFAULT Fault Output Current = 10mA - - 0.4 V ENABLE High Threshold Ven_vih VIN = 5.5V 2.0 - - V ENABLE Low Threshold at 2.7V Ven_vil VIN = 2.7V - - 0.6 V ENABLE Low Threshold at 5.5V Ven_vil VIN = 5.5V - - 0.8 V -0.5 0 0.5 A OC Regulation Settling Time Severe OC Regulation Settling Time Overcurrent Latch-off Time I/O PARAMETERS ENABLE Input Current Ien_i ENABLE = 0V to 5V, VIN = 5V, TJ > 25C Enabled VIN Current IVDD Switches Closed, OUTPUT = OPEN, TJ > 0C - 120 200 A Disabled VIN Current IVDD Switches Open, OUTPUT = OPEN - 1 5 A 1.7 2.25 2.5 V BIAS PARAMETERS VIN Rising, Switch Enabled Undervoltage Lockout Threshold VUVLH UV Hysteresis UVHYS 50 100 - mV Temp_dis - 150 - C Over Temperature Disable 3 ISL6118 Introduction The ISL6118 is a fully independent dual channel overcurrent (OC) fault protection IC for the +2.5V to +5.5V environment. Each ISL6118 incorporates in a single 8-lead SOIC package two 80mW N-channel MOSFET power switches for power control. See Figure 2 for integrated FET on resistance curves. Independent enabling inputs and fault reporting outputs compatible with 3V and 5V logic allow for external control and monitoring. This device features internal current monitoring, accurate current limiting, integrated power switches and current limited timed delay to latch-off for system protection. Key Feature Description and Operation UV Lockout The ISL6118 undervoltage (UVLO) lockout prevents functionality of the device unless the correct ENABLE state and VIN > 2.5V are present. Soft Start A constant 500nA current source ramps up the switch's gate causing a voltage follower effect on the output voltage. This provides a soft start turn-on and eliminates bus voltage drooping caused by inrush current charging heavy load capacitances. Rising and falling outputs are current limited voltage ramps so that both the inrush current and voltage slew rate are limited, independent of load. This reduces supply droop due to surge and also eliminates the need for external EMI filters necessary on other IC products. See Figure 3 for soft start waveforms. Fault Blanking on Start-Up During initial turn-on the ISL6118 prevents nuisance faults from being reported to the system controller by blanking the fault signal for 12ms. This blanking eliminates the need for external RC filters necessary for other vendors' products. Current Regulation The ISL6118 has integrated current sensing on the power MOSFETs that allows for rapid control of OC events. Once an OC condition is detected the ISL6118 goes into its current regulation (CR) control mode. The ISL6118 CR level is set to a nominal 0.6A and is regulated to within 25% over full temperature, bias voltage range and OC magnitude. The speed of this control is proportional to the level of OC. Thus a hard OC is more quickly controlled than a marginal condition. See Figures 4 through 7 for current regulation performance curves and waveforms. thermal or adjacent switch's electrical condition. See Figure 10 for waveforms illustrating independent latch-off. If, after the ISL6118 has latched off, and the fault has asserted and the enable is not deasserted but the OC condition still exists, the ISL6118 (unlike other IC devices) does not send to the controller a continuous string of fault pulses. The ISL6118's single fault signal is sent at the time of latch off. Slow and Fast Shutdown The ISL6118 has two shutdown modes. When disabled with a load current less than the current regulation (CR) level the ISL6118 shuts down in a controlled manner using a 500nA constant current source controlled ramp. When disabled during CR or if the timer has expired the ISL6118 quickly pulls down the output thereby quickly removing the faulted load from the voltage bus. See Figures 8 and 9 for illustrative waveforms of each shutdown mode. Over Temperature Shutdown Although the ISL6118 has a thermal shutdown feature, because of the 12ms timed shutdown this will only be invoked in extremely high ambient temperatures. Active Output Pulldown Another unique ISL6118 feature is the active pull down on the outputs to 300mV above GND when the device is disabled. Figure 1 illustrates the ISL6118 operational waveforms, showing the relationships between the various I/O signals during typical and faulted conditions. It also graphically highlights many of the terms and modes of operation referred to in this data sheet. Using the ISL6118EVAL1 Platform General and Biasing Information The ISL6118EVAL1 platform, Figure 14, allows evaluation of the ISL6118 dual power supply control IC and comparison against a suitably sized PPTC component. The evaluation platform is biased and monitored through numerous test points (TP#). See Table 1 for test point assignments and descriptions. TABLE 1. ISL6118EVAL1 TEST POINT ASSIGNMENTS TP # DESCRIPTION TP1 Eval Board and IC GND TP2 Eval Board +3.3V Bias TP3 Enable Switch 1 Latch-Off Time Delay TP4 Enable Switch 2 The primary function of any OC protection device is to quickly isolate the voltage bus from a faulty load. Unlike other manufacturers' IC products that sense the IC thermal condition to isolate a faulty load, the ISL6118 uses an internal 12ms timer that starts upon OC detection. Once an OC condition is detected, the appropriate output is current limited for 12ms to allow transient conditions to pass before latch-off. The time to latch-off is independent of the device's TP5 Switch 2 Fault TP6 Switch Out 2 TP7 Switch Out 1 TP8 Switch 1 Fault 4 TP9 IC VIN Pin TP10 PPTC Load Side TP11 Invoke Overcurrent ISL6118 Typical Performance Curves RESET BY ENABLE ON ENABLE OFF FAULT LATCH-OFF SET CURRENT REGULATION SETTLING TIME (1.4ms) VOUT 0.6A CURRENT LIMIT OVERCURRENT IOUT 12ms CURRENT REGULATION PERIOD FIGURE 1. OPERATIONAL WAVEFORMS 120 SWITCH ON RESISTANCE (m) 110 ENABLE 100 CL = 100F VIN = 2.7V CL = 0.1F 90 CL = 10F 80 VIN = 5V tPD 70 560s VIN = 3.3V 60 50 40 -40 -30 -20 -10 0 VOUT 10 20 30 40 50 60 70 80 90 100 VOUT VOLTAGE (0.5V/DIV) TEMPERATURE (C) TIME (400s/DIV) FIGURE 3. VOUT SOFT START vs CL and PROP DELAY, Rl = 8 FIGURE 2. SWITCH ON RESISTANCE AT 0.4A 3.1 700 700 -40C -40C 650 600 IOUT (mA) IOUT (mA) 650 25C 25C 600 85C 550 550 85C 500 500 1.25 1.5 1.75 2.0 2.25 VOUT (V) 2.5 2.75 3.0 FIGURE 4. CURRENT REGULATION vs VOUT (VIN = 3.3V) 5 1.3 1.5 2.0 2.5 3.0 VOUT (V) 3.5 4.0 4.5 4.8 FIGURE 5. CURRENT REGULATION vs VOUT (VIN = 5V) ISL6118 Typical Performance Curves (Continued) TIME TO CURRENT REGULATION (ms) OUTPUT CURRENT (1A/DIV) 1.6 CURRENT REGULATED LEVEL 0.6A NOMINAL CURRENT 0.4A 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 1 2 3 TIME (200s/DIV) FIGURE 6. OC TO CR SETTLING TIME WAVEFORMS 4 5 6 7 8 9 10 11 12 FAULT CURRENT (A) FIGURE 7. CR SETTLING TIME vs FAULT CURRENT ENABLE CL= 10F VOUT CL= 100F CL= 10F CL= 100F CL= 0.1F CL= 0.1F VOUT VOUT VOLTAGE (0.5V/DIV) TIME (400s/DIV.) FIGURE 8. SLOW TURN-OFF vs CL, Rl = 8 VOUT VOLTAGE (0.5V/DIV) FIGURE 9. FAST TURN-OFF vs CLOAD ISL6118 OUT 1 VIN ISL6118 OUT 2 VOLTAGE (0.5V/DIV) TIME (4ms/DIV) FIGURE 10. SWITCH FAULT INDEPENDENCE 6 TIME (400s/DIV) ISL6118 Typical Performance Curves (Continued) VIN ISL6118 VOUT 3.29V (0.075) 0.4A HOLD CURRENT PPTC 2.93V (1.1) 0.4A HOLD CURRENT PPTC OUT VVIN 3.32V ISL6118 CR 12ms PERIOD GND VOLTAGE (0.5V/DIV) VOLTAGE (0.5V/DIV) FIGURE 11. ISL6118 vs PPTC INTO 8.2 LOAD ISL6118 OUT TIME (4ms/DIV) FIGURE 12. ISL6118 vs PPTC INTO 3.5 LOAD VIN 0.4A HOLD CURRENT PPTC OUT 2.3V AT 10s 1.5V AT 30s ISL6118 OUT VOLTAGE (0.5V/DIV) TIME (4s/DIV) FIGURE 13. ISL6118 vs PPTC WITH EXTENDED 3.5 LOAD Using the ISL6118EVAL1 Platform Upon proper bias the PPTC, F1, has a nominal 400mA load current passing through it which is the hold current rating for that particular device. Removal of the PPTC is necessary to isolate the ISL6118 as the PPTC load current is common to the ISL6118EVAL1 bias connections. By enabling either or both of the ISL6118H switches by signaling TP3 and/or TP4 high (>2.4V) these switches are also loaded with a nominal 400mA current. Provided test points enable the evaluation of voltage loss across the PPTC (TP9 - TP10) and likewise across the ISL6118 enabled switches (TP9 - TP6 and TP7). Expect to see 100% - 300% greater voltage loss across the PPTC than the ISL6118 (see Figure 11 for ISL6118 vs PPTC voltage loss comparison). An overcurrent (OC) condition can be invoked on both the ISL6118 and the PPTC by driving TP11 to +6V, causing SW1 to close and a nominal 0.94mA load is imposed. This 7 represents a current overload to the ISL6118 and is thus quickly current regulated to the 600mA limit. If the OC duration extends beyond the nominal 12ms of the internal ISL6118 timer then the output is latched off and the fault output is asserted by being pulled low turning on the appropriate FAULT LED. (Please note: the labeling for the FAULT-1 and FAULT-2 is reversed.) The eval board is designed to only invoke a OC condition on channel 2 (TP4) so that a channel to channel isolation evaluation in the presence of a OC condition can be evaluated. The primary function of any OC protection device is to quickly isolate the voltage bus from a faulty load. Unlike the PPTC and other vendor available IC products, the ISL6118 internal timer that starts upon OC detection provides consistent protection that is independent of temperature. Figures 11 through 13 illustrate the comparative efficiency and effectiveness of the ISL6118 vs the PPTC in protecting and isolating a faulty load capable from drooping the system bus in that system. ISL6118 C2 ISL6118EVAL1 R1 R6 D2 C1 R8 D3 C3 FAULT_OUT1 8 1 TP2 (VIN) 2 TP3 3 TP4 4 EN2 FAULT_OUT2 5 VIN OUT1 7 ISL6118 OUT2 6 EN1 R4 TP7 TP6 R2 D4 R7 D1 R9 SW1 C4 R5 TP9 TP10 F1 R3 D5 R10 FIGURE 14. ISL6118EVAL1 SCHEMATIC AND PHOTOGRAPH TABLE 2. ISL6118EVAL1 BOARD COMPONENT LISTING COMPONENT DESIGNATOR DUT1 COMPONENT FUNCTION COMPONENT DESCRIPTION ISL6118 Intersil, ISL6118HIB 3.3V Aux Hot Plug Controller R1 - R3 410mA Nominal Load Resistors YAGEO, 8, 5%, 2W, 8W-2-ND R4 - R5 970mA Current Over Load Resistors YAGEO, 6, 5%, 2W, 6W-2-ND R6 - R10 LED Current Limiting Resistor 470, 0805 Decoupling Capacitor 0.1F, 0805 C2 - C4 Load Capacitor 100F, 16V Electrolytic, Radial lead D1 - D5 Indicating LEDs 0805, SMD LEDs Red F1 PPTC (Polymer Positive Temperature Coefficient) Raychem, Poly Switch, RXE040 or Equivalent SW1(Q1) Current Over Load Invoking Switch Access TP11 Fairchild, ITF86110DK8T, 7.5A, 30V, 0.025, Dual N-channel, Logic Level Power MOSFET C1 8 ISL6118 Implementing Autoreset on the ISL6118H Hot Swap Controllers Description of Operation Abstract In applications where the cost, complexity or requirement for a system controller is avoided and an autonomous power control function is desired, a device that can monitor and protect against excessive current failures is needed. This shows how to implement such an autonomous controller using the ISL6118HIB. This application works only with the `H' version of these devices. The `H' version refers to the enable function being asserted upon a high input. Introduction The ISL6118, ISL6119 and ISL6121 are all 2.5V to 5V power supply controllers, each having a different level of current regulation (CR). The ISL6118 and ISL6119 have 2 independent controllers with CR levels of 0.6A and 1.0A respectively whereas the ISL6121 is a single supply controller with a 2A CR level. Each of these devices features integrated power switch(es) for power control. Each switch is driven by a constant current source giving a controlled ramp up of the output voltage. This provides a soft start turn-on eliminating bus voltage drooping caused by in-rush current while charging heavy load capacitances. The independent enabling inputs and fault reporting outputs for each channel are available and necessary for the autonomous autoreset application. The undervoltage (UV) feature prevents turn-on of the outputs unless the ENABLE pin and VIN are >2.5V. During initial turn-on the ISL6118 prevents fault reporting by blanking the fault signal. Rising and falling outputs are current-limited voltage ramps so that both the inrush current and voltage slew rate are limited, independent of load. This reduces supply droop due to surge and eliminates the need for external EMI filters. During operation, once an OC condition is detected the appropriate output is current limited to the appropriate level for 10ms to allow transient conditions to pass. If still in current limit after the current limit period has elapsed, the output is latched off and the fault is reported by pulling the corresponding FAULT low. The FAULT signal is latched low until reset by the ENABLE signal being deasserted at which time the FAULT signal will clear. It is this described sequence of events that allows for the autoreset function to be implemented in a cost efficient manner requiring the addition of only an RC network per channel to the typical application. Figure 15 illustrates the RC network needed with suggested component values and the configuration of the relevant pins for each autoreset channel. 9 Rpu = 2K VIN ISL6118H FLTn ENABLE C = 0.1F GND FIGURE 15. Initially as voltage is applied to VIN, the pull up resistor (Rpu) provides for pull up to VIN on both the ENABLE pin asserting the output once VIN > 2.5V and on the FLTn pin. Once turned on and an overcurrent (OC) condition occurs the IC provides CR protection for 10ms and then the FLTn pin pulls low through Rpu and also pulling the ENABLE low thus resetting the device fault condition. At this time the Rpu charges the cap and the voltage on the ENABLE/FLTn node rises until the ENABLE > 2.0 and the output is asserted on once again. This automatic reset cycle will continue until the OC fault no longer exists on the output. After several seconds in this mode of operation the IC thermal protection invokes adjusting the timing of the on-off cycle to prevent excessive thermal dissipation in the power switch protecting itself and surrounding circuitry. See Figure 16 for operation waveform. . VIN/FLTn 5V/DIV VOUT 2V/DIV 0V IOUT 1A/DIV 0A 4ms/DIV FIGURE 16. AUTO RESET OPERATION Applications * USB * 2.5V to 5V up to 10W power port protection ISL6118 Small Outline Plastic Packages (SOIC) M8.15 (JEDEC MS-012-AA ISSUE C) N INDEX AREA 0.25(0.010) M H 8 LEAD NARROW BODY SMALL OUTLINE PLASTIC PACKAGE B M E INCHES -B- 1 2 SYMBOL 3 L SEATING PLANE -A- h x 45o A D -C- e A1 B 0.25(0.010) M C C A M B S 1. Symbols are defined in the "MO Series Symbol List" in Section 2.2 of Publication Number 95. MILLIMETERS MIN MAX NOTES A 0.0532 0.0688 1.35 1.75 - 0.0040 0.0098 0.10 0.25 - B 0.013 0.020 0.33 0.51 9 C 0.0075 0.0098 0.19 0.25 - D 0.1890 0.1968 4.80 5.00 3 E 0.1497 0.1574 3.80 4.00 4 0.050 BSC 1.27 BSC - H 0.2284 0.2440 5.80 6.20 - h 0.0099 0.0196 0.25 0.50 5 L 0.016 0.050 0.40 1.27 6 8 0 N NOTES: MAX A1 e 0.10(0.004) MIN 8 0 8 7 8 Rev. 0 12/93 2. Dimensioning and tolerancing per ANSI Y14.5M-1982. 3. Dimension "D" does not include mold flash, protrusions or gate burrs. Mold flash, protrusion and gate burrs shall not exceed 0.15mm (0.006 inch) per side. 4. Dimension "E" does not include interlead flash or protrusions. Interlead flash and protrusions shall not exceed 0.25mm (0.010 inch) per side. 5. The chamfer on the body is optional. If it is not present, a visual index feature must be located within the crosshatched area. 6. "L" is the length of terminal for soldering to a substrate. 7. "N" is the number of terminal positions. 8. Terminal numbers are shown for reference only. 9. The lead width "B", as measured 0.36mm (0.014 inch) or greater above the seating plane, shall not exceed a maximum value of 0.61mm (0.024 inch). 10. Controlling dimension: MILLIMETER. Converted inch dimensions are not necessarily exact. All Intersil U.S. products are manufactured, assembled and tested utilizing ISO9000 quality systems. Intersil Corporation's quality certifications can be viewed at www.intersil.com/design/quality Intersil products are sold by description only. Intersil Corporation reserves the right to make changes in circuit design, software and/or specifications at any time without notice. Accordingly, the reader is cautioned to verify that data sheets are current before placing orders. Information furnished by Intersil is believed to be accurate and reliable. However, no responsibility is assumed by Intersil or its subsidiaries for its use; nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Intersil or its subsidiaries. For information regarding Intersil Corporation and its products, see www.intersil.com 10