KBP2005 thru KBP210 Glass Passivated Bridge Rectifiers REVERSE VOLTAGE 50 to 1000 VOLTS FORWARD CURRENT 2.0 AMPERES P b Lead(Pb)-Free Features: * Surge overload rating - 60 amperes peak * Ideal for printed circuit board * High case dielectric strength * Reliable low cost construction utilizing molded plastic technique * Plastic package used has Underwriters Laboratory Flammability Classification 94V-0 * High temperature soldering guaranteed: 260C/10 seconds at 5lbs. (2.3kg) tension KBP Mechanical Data: * Case: Molded plastic body over passivated junctions * Terminals: Plated lead solderable per MIL-STD-202, method 208 * Polarity: Polarity symbols marked on body * Weight: 0.06 ounce, 1.7 grams KBP Outline Dimensions K KBP A Dim B J H C G M L WEITRON http://www.weitron.com.tw Max 14.22 15.24 10.67 11.68 11.68 12.70 15.24 12.70 3.56 4.06 1.52 0.71 0.84 o 3.18 X 45 K CHAMFER L 4.57 5.08 M 2.16 2.67 All Dimensions in mm A B C D E G H J E D Min 1/3 20-Feb-06 KBP2005 thru KBP210 Maximum Rating Characteristic Symbol KBP2005 KBP201 KBP202 KBP204 KBP206 KBP208 KBP210 Uuits Maximum repetitive peak reverse voltage VRRM 50 100 200 400 600 800 1000 V Maximum RMS voltage VRMS 35 70 140 280 420 560 700 V Maximum DC blocking voltage VDC 50 100 200 400 600 800 1000 V Maximum average forward rectified current 0.375" (9.5mm) lead length at TA=50C IAV 2.0 A Peak forward surge current 8.3mS single half sine-wave super imposed on rated load (MIL-STD-750D 4066 method) IFSM 60 A TJ -50 to +150 C TSTG -50 to +150 C Operating junction temperature range Storage temperature range Electrical Characteristic Characteristic Symbol KBP2005 KBP201 KBP202 KBP204 KBP206 KBP208 KBP210 Uuits Maximum Forward Voltage Drop per Bridge Element at 1.0A Peak VF 1.1 V Maximum Instantaneous Reverse Current Rated DC Voltage, TA=25C TA=100C IR 10.0 A WEITRON http://www.weitron.com.tw 1000 2/3 20-Feb-06 KBP2005 thru KBP210 Ratings and Characteristics Curves 10 INSTANTANEOUS FORWARD CURRENT(A) AVERAGE FORWARD CURRENT(A) 2.0 1.5 1.0 SINGLE PHASE HALF WAVE 60Hz RESISTIVE OR INDUCTIVE LOAD 0.5 0 0 25 50 75 100 125 150 AMBIENT TEMPERATURE (C) 1.0 TJ = 25C PULSE WIDTH = 300s 1 % DUTY CYCLE 0.1 0.01 0.4 Fig.1 Typical Forward Current Derating Curve 0.6 0.8 1.0 1.2 1.4 INSTANTANEOUS FORWARD VOLTAGE (V) 10 PEAK FORWARD SURGE CURRENT(A) INSTANTANEOUS REVERSE CURRENT(mA) Fig.4 Typical Instantaneous Forward Per Bridge Element 1.0 TJ = 25C 0.1 0.01 0 20 40 60 80 100 120 140 TJ = 25C 30 15 0 1 10 100 Fig.2 Maximum Non-repetitive Peak Forward Surge Current Per Bridge Element Fig.3 Typical Reverse Characteristics http://www.weitron.com.tw 45 NUMBER OF CYCLES AT 60Hz PERCENT OF RATED PEAK REVERSE VOLTS (%) WEITRON 60 3/3 20-Feb-06